Y. Hatsukade
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Y. Hatsukade has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
S. Tanaka
Toyohashi University of Technology, 1-1 Hibarigaoka, Tempaku-cho, Toyohashi, Aichi 441-8580, Japan
4 shared publicationsS Tanaka
Toyohashi University of Technology, 1-1 Hibarigaoka, Tempaku-cho, Toyohashi, Aichi 441-8580, Japan
2 shared publicationsA Miyazaki
Toyohashi University of Technology, 1-1 Hibarigaoka, Tempaku-cho, Toyohashi, Aichi 441-8580, Japan
1 shared publicationA. Ishiyama
Waseda University, 3-4-1 Ohkubo, Shinjuku, Tokyo 169-8555, Japan
1 shared publicationA. Miyazaki
Department of Ecological Engineering, Toyohashi University of Technology, 1-1 Hibarigaoka, Tempaku-cho, Toyohashi, Aichi 441-8580, Japan
1 shared publicationA. Suzuki
Shikoku Electric Power Co. Inc., 2-5 Marunouchio, Takakmatsu, Kagawa 760-8573, Japan
1 shared publication
Latest Publications
- 1 November 2010
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 470 (20) , 1524-1528
Evaluation of joint interface of friction stir welding between dissimilar metals using HTS-SQUID gradiometer
- 1 November 2010
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 470 (20) , 1524-1528
Evaluation of joint interface of friction stir welding between dissimilar metals using HTS-SQUID gradiometer
- 1 June 2010
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 234 (4) , 042012
Robot-arm-based NDE of hydrogen fuel tank using a 3D-movable HTS-SQUID gradiometer
In this study, we constructed a robot-arm-based SQUID-NDE system utilizing a novel HTS-SQUID gradiometer with ramp-edge Josephson junctions for hydrogen fuel tank inspection, and developed an automatic 3D-scanning program. A cylindrical hydrogen fuel tank with a double-layer structure, in which a 3mm-thick Al liner was reinforced by a 3mm-thick carbon-fibre reinforced plastic (CFRP) cover, was prepared. The tank had a 10-mm-long through crack in the Al liner made by pressure cycle test. To inspect the tank using the SQUID-NDE system, we adopted a low-frequency eddy current technique that enables to excite deep part in the Al liner. By applying an excitation field of 7.5 μT at 0.4 to 10 kHz to the tank from a double-D coil, the tank was scanned by the system while moving the HTS-SQUID gradiometer along curved surface of the tank in magnetically unshielded environment. Magnetic responses from the deep-lying crack in the tank were successfully detected by the system.
- 1 June 2010
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 234 (4) , 042012
Robot-arm-based NDE of hydrogen fuel tank using a 3D-movable HTS-SQUID gradiometer
In this study, we constructed a robot-arm-based SQUID-NDE system utilizing a novel HTS-SQUID gradiometer with ramp-edge Josephson junctions for hydrogen fuel tank inspection, and developed an automatic 3D-scanning program. A cylindrical hydrogen fuel tank with a double-layer structure, in which a 3mm-thick Al liner was reinforced by a 3mm-thick carbon-fibre reinforced plastic (CFRP) cover, was prepared. The tank had a 10-mm-long through crack in the Al liner made by pressure cycle test. To inspect the tank using the SQUID-NDE system, we adopted a low-frequency eddy current technique that enables to excite deep part in the Al liner. By applying an excitation field of 7.5 μT at 0.4 to 10 kHz to the tank from a double-D coil, the tank was scanned by the system while moving the HTS-SQUID gradiometer along curved surface of the tank in magnetically unshielded environment. Magnetic responses from the deep-lying crack in the tank were successfully detected by the system.
- 14 October 2008
- Published by Elsevier in NDT & E International
- Vol. 42 (3) , 170-173
Study of inspection of wire breakage in aluminum transmission line using SQUID
- 14 October 2008
- Published by Elsevier in NDT & E International
- Vol. 42 (3) , 170-173
Study of inspection of wire breakage in aluminum transmission line using SQUID
- 15 September 2008
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 468 (15-20) , 1932-1935
Mobile HTS-SQUID NDE system with robot arm and active shielding using fluxgate
- 15 September 2008
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 468 (15-20) , 1932-1935
Mobile HTS-SQUID NDE system with robot arm and active shielding using fluxgate
- 1 February 2008
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 97 (1) , 012103
SQUID-NDE of wire breakage in aluminium transmission line
SQUID-NDE technique was applied to detection of wire breakage in aluminium transmission line, and aluminium clamp composed of compressed conductor joint. Hard aluminium transmission lines twisted from 19 aluminium wires with or without a wire breakage were prepared. While applying ac current of 2.6 mA at 200 Hz to the line, distributions of magnetic field gradient above the transmission lines were measured by a SQUID-NDE system using a HTS SQUID gradiometer. A periodic pattern was detected along the locus of broken wire in the distribution of the field gradient generated from the line with wire breakage, while such pattern was not observed in the normal line without wire breakage. Numerical simulation of distribution of field gradient from the aluminium transmission line was also carried out to compare it with the experimental results.
- 1 February 2008
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 97 (1) , 012103
SQUID-NDE of wire breakage in aluminium transmission line
SQUID-NDE technique was applied to detection of wire breakage in aluminium transmission line, and aluminium clamp composed of compressed conductor joint. Hard aluminium transmission lines twisted from 19 aluminium wires with or without a wire breakage were prepared. While applying ac current of 2.6 mA at 200 Hz to the line, distributions of magnetic field gradient above the transmission lines were measured by a SQUID-NDE system using a HTS SQUID gradiometer. A periodic pattern was detected along the locus of broken wire in the distribution of the field gradient generated from the line with wire breakage, while such pattern was not observed in the normal line without wire breakage. Numerical simulation of distribution of field gradient from the aluminium transmission line was also carried out to compare it with the experimental results.
- 1 June 2004
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 412-414, 1484-1490
Detection of deep-lying defects in carbon fiber composites using SQUID-NDE system cooled by a cryocooler
- 1 June 2004
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 412-414, 1484-1490
Detection of deep-lying defects in carbon fiber composites using SQUID-NDE system cooled by a cryocooler