Isil Akmehmet Balcioglu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Isil Akmehmet Balcioglu has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Nalan Bilgin Oncu
Bogazici Univ, Inst Environm Sci, TR-34342 Istanbul, Turkey
4 shared publications C. Kıvılcımdan
Department of Environmental Engineering, Middle East Technical University, 06531 Ankara, Turkey
2 shared publicationsE. Tarlan
Faculty of Engineering and Architecture, Department of Environmental Engineering, Selçuk University, 42075 Kampus-Konya, Turkey
2 shared publicationsIdil Arslan
Boğaziçi University, Institute of Environmental Sciences, 80815 Bebek, Istanbul, Turkey
2 shared publicationsMerih Ötker
Boğaziçi University Institute of Environmental Sciences , Bebek, Istanbul, Turkey
2 shared publicationsC. Saraç
Boğaziçi University, Institute of Environmental Sciences , Bebek, Istanbul, Turkey
1 shared publication
Latest Publications
- 10 May 2021
- Published by Springer Nature
- p. 347-359
Cleanup and Pollution with Nanoparticles: Environmental Dilemma
- 10 May 2021
- Published by Springer Nature
- p. 347-359
Cleanup and Pollution with Nanoparticles: Environmental Dilemma
- 21 October 2016
- Published by Wiley in Journal of Chemical Technology & Biotechnology
- Vol. 92 (6) , 1192-1202
Beneficial effects of treating waste secondary sludge with thermally activated persulfate
BACKGROUND: The presence of numerous emerging contaminants including antimicrobials in waste activated sludge requires an effective treatment to reduce the risk of their dispersion in the environment in the case of land application. The potential ability of activated persulfate oxidation for organic contaminant destruction and sludge dewatering was subjected to detailed study to show the benefits of this process on sludge treatment.RESULTS: Treatment of secondary waste sludge with persulfate thermally activated by microwave heating (S2O82−/MW), conventional heating (S2O82−/heat) and simultaneous conventional heating and ferrous iron (S2O82−/heat/Fe2+) were evaluated comparatively for both antimicrobial degradation and variation of sludge properties. Regardless of the activation type used in persulfate treatment, high degradations of model antimicrobials and shortened capillary suction time used to evaluate sludge dewaterability were obtained, with high destruction of tightly and loosely bound fractions of the extracellular polymeric substances.CONCLUSION: While S2O82−/MW treatment required shorter treatment period at 140 °C S2O82−/heat/Fe2+ treatment with a two‐fold lower dose of oxidant at 75 °C provided several other advantages including the minimization of adsorbable organic halogen species in the liquid phase of the sludge, enhancement of the overall metal solubilization, and precipitation of solubilized phosphorus. © 2016 Society of Chemical Industry
- 21 October 2016
- Published by Wiley in Journal of Chemical Technology & Biotechnology
- Vol. 92 (6) , 1192-1202
Beneficial effects of treating waste secondary sludge with thermally activated persulfate
BACKGROUND: The presence of numerous emerging contaminants including antimicrobials in waste activated sludge requires an effective treatment to reduce the risk of their dispersion in the environment in the case of land application. The potential ability of activated persulfate oxidation for organic contaminant destruction and sludge dewatering was subjected to detailed study to show the benefits of this process on sludge treatment.RESULTS: Treatment of secondary waste sludge with persulfate thermally activated by microwave heating (S2O82−/MW), conventional heating (S2O82−/heat) and simultaneous conventional heating and ferrous iron (S2O82−/heat/Fe2+) were evaluated comparatively for both antimicrobial degradation and variation of sludge properties. Regardless of the activation type used in persulfate treatment, high degradations of model antimicrobials and shortened capillary suction time used to evaluate sludge dewaterability were obtained, with high destruction of tightly and loosely bound fractions of the extracellular polymeric substances.CONCLUSION: While S2O82−/MW treatment required shorter treatment period at 140 °C S2O82−/heat/Fe2+ treatment with a two‐fold lower dose of oxidant at 75 °C provided several other advantages including the minimization of adsorbable organic halogen species in the liquid phase of the sludge, enhancement of the overall metal solubilization, and precipitation of solubilized phosphorus. © 2016 Society of Chemical Industry
- 1 October 2013
- Published by Elsevier in Bioresource Technology
- Vol. 146, 126-134
Microwave-assisted chemical oxidation of biological waste sludge: Simultaneous micropollutant degradation and sludge solubilization
- 1 October 2013
- Published by Elsevier in Bioresource Technology
- Vol. 146, 126-134
Microwave-assisted chemical oxidation of biological waste sludge: Simultaneous micropollutant degradation and sludge solubilization
- 27 March 2013
- Published by Taylor & Francis in Ozone: Science & Engineering
- Vol. 35 (2) , 73-85
Antimicrobial Contamination Removal from Environmentally Relevant Matrices: A Literature Review and a Comparison of Three Processes for Drinking Water Treatment
The effectiveness of conventional water treatment technology in preventing the dissemination of antimicrobial contamination has been questioned due to significant rates of antibiotic resistance elements found both in solid wastes and in effluents. This implies that preventive efforts must cover both solid waste quality and effluent quality monitoring. This article presents a review of the occurrence data for a number of antibiotics and antibiotic resistance carriers along with the effectiveness of conventional and advanced technologies in the removal of antimicrobial contamination from various matrices. Although the current literature suggests that the advanced oxidation processes are more promising, cost viable oxidant doses may not be sufficient to reach targeted removal efficiencies especially in biosolids and manure. As a result, antimicrobial contamination can inevitably reach natural waters and contaminate drinking water sources. In this context, a comparison of the effectiveness of three oxidation processes on the removal of a resistance carrier bacterial plasmid DNA was studied. The relative effectiveness of ozonation or heterogeneous photocatalysis over conventional chlorination was demonstrated.
- 27 March 2013
- Published by Taylor & Francis in Ozone: Science & Engineering
- Vol. 35 (2) , 73-85
Antimicrobial Contamination Removal from Environmentally Relevant Matrices: A Literature Review and a Comparison of Three Processes for Drinking Water Treatment
The effectiveness of conventional water treatment technology in preventing the dissemination of antimicrobial contamination has been questioned due to significant rates of antibiotic resistance elements found both in solid wastes and in effluents. This implies that preventive efforts must cover both solid waste quality and effluent quality monitoring. This article presents a review of the occurrence data for a number of antibiotics and antibiotic resistance carriers along with the effectiveness of conventional and advanced technologies in the removal of antimicrobial contamination from various matrices. Although the current literature suggests that the advanced oxidation processes are more promising, cost viable oxidant doses may not be sufficient to reach targeted removal efficiencies especially in biosolids and manure. As a result, antimicrobial contamination can inevitably reach natural waters and contaminate drinking water sources. In this context, a comparison of the effectiveness of three oxidation processes on the removal of a resistance carrier bacterial plasmid DNA was studied. The relative effectiveness of ozonation or heterogeneous photocatalysis over conventional chlorination was demonstrated.
- 1 January 2013
- Published by Sycamore Global Publications in Journal of Advanced Oxidation Technologies
- Vol. 16 (1) , 107-116
Degradation of Ciprofloxacin and Oxytetracycline Antibiotics in Waste Sewage Sludge by Ozonation
Efficiency of ozonation process for simultaneous degradation of two antibiotics, ciprofloxacin (CIP) and oxytetracycline (OTC), at high and low concentrations of them was investigated in artificially contaminated waste activated sludge (WAS). The desorption of the antibiotics, which was provided either by Mg
- 1 January 2013
- Published by Sycamore Global Publications in Journal of Advanced Oxidation Technologies
- Vol. 16 (1) , 107-116
Degradation of Ciprofloxacin and Oxytetracycline Antibiotics in Waste Sewage Sludge by Ozonation
Efficiency of ozonation process for simultaneous degradation of two antibiotics, ciprofloxacin (CIP) and oxytetracycline (OTC), at high and low concentrations of them was investigated in artificially contaminated waste activated sludge (WAS). The desorption of the antibiotics, which was provided either by Mg
- 1 January 2011
- Published by Sycamore Global Publications in Journal of Advanced Oxidation Technologies
- Vol. 14 (2) , 196-203
Comparison of the Effectiveness of Chlorine, Ozone, and Photocatalytic Disinfection in Reducing the Risk of Antibiotic Resistance Pollution
Effectiveness of conventional chlorine and ozone disinfection on reduction of antibiotic resistance was compared with less commonly applied heterogeneous photocatalytic process. For this purpose plasmid DNA isolated from a multi-resistant Escherichia coli (E. coli) HB101 was treated in two different concentrations with the three oxidation processes. Oxidative damage on the plasmid DNA was analyzed with gel electrophoresis by comparing the extent of conformational changes in the DNA structure. The effectiveness of the applied oxidant in reducing the risk of resistance transfer was also evaluated by comparing the ability of treated plasmid DNA to transform competent cells. Chlorine did not affect plasmid DNA structure at the studied doses, while ozone and photocatalytic treatment resulted in conformational changes and the damage increased with increasing oxidant doses. Transformation experiments confirmed a similar trend. Chlorine did not affect the transformability and the cell counts of competent cells transformed with chlorine treated plasmid DNA were similar to those transformed by non-treated plasmid DNA in the control experiments.
- 1 January 2011
- Published by Sycamore Global Publications in Journal of Advanced Oxidation Technologies
- Vol. 14 (2) , 196-203
Comparison of the Effectiveness of Chlorine, Ozone, and Photocatalytic Disinfection in Reducing the Risk of Antibiotic Resistance Pollution
Effectiveness of conventional chlorine and ozone disinfection on reduction of antibiotic resistance was compared with less commonly applied heterogeneous photocatalytic process. For this purpose plasmid DNA isolated from a multi-resistant Escherichia coli (E. coli) HB101 was treated in two different concentrations with the three oxidation processes. Oxidative damage on the plasmid DNA was analyzed with gel electrophoresis by comparing the extent of conformational changes in the DNA structure. The effectiveness of the applied oxidant in reducing the risk of resistance transfer was also evaluated by comparing the ability of treated plasmid DNA to transform competent cells. Chlorine did not affect plasmid DNA structure at the studied doses, while ozone and photocatalytic treatment resulted in conformational changes and the damage increased with increasing oxidant doses. Transformation experiments confirmed a similar trend. Chlorine did not affect the transformability and the cell counts of competent cells transformed with chlorine treated plasmid DNA were similar to those transformed by non-treated plasmid DNA in the control experiments.
- 1 January 2009
- Published by Sycamore Global Publications in Journal of Advanced Oxidation Technologies
- Vol. 12 (1) , 134-143
Effects of Inorganic Anions and Humic Acid on the Photocatalytic and Ozone Oxidation of Oxytetracycline in Aqueous Solution
- 1 January 2009
- Published by Sycamore Global Publications in Journal of Advanced Oxidation Technologies
- Vol. 12 (1) , 134-143
Effects of Inorganic Anions and Humic Acid on the Photocatalytic and Ozone Oxidation of Oxytetracycline in Aqueous Solution
- 24 July 2008
- Published by Taylor & Francis in Ozone: Science & Engineering
- Vol. 30 (4) , 290-299
Ozonation of Animal Wastes Containing Oxytetracycline
The efficiency of ozonation on the degradation of oxytetracycline, a veterinary antibiotic, has been investigated in both cow manure and synthetic animal feeding operation wastewater at varying experimental conditions. With a rapid degradation of antibiotic in synthetic wastewater, ozonation improved its biodegradability and eliminated bacterial toxicity caused by oxytetracycline. The degradation rate of oxytetracycline depended on pH and applied ozone dose, but not initial antibiotic concentration in wastewater. In the case of manure treatment, ozonation efficiency in terms of oxytetracycline degradation was negatively affected by moisture and antibiotic content of manure. The degradation rate of oxytetracycline in manure slowed down upon the extension of treatment time since ozone could not react with strongly adsorbed antibiotic on manure. Increase in humic and fulvic acid carbon and mineral nitrogen content was an indicator for the improvement of fertilizing value of manure by ozonation.
- 24 July 2008
- Published by Taylor & Francis in Ozone: Science & Engineering
- Vol. 30 (4) , 290-299
Ozonation of Animal Wastes Containing Oxytetracycline
The efficiency of ozonation on the degradation of oxytetracycline, a veterinary antibiotic, has been investigated in both cow manure and synthetic animal feeding operation wastewater at varying experimental conditions. With a rapid degradation of antibiotic in synthetic wastewater, ozonation improved its biodegradability and eliminated bacterial toxicity caused by oxytetracycline. The degradation rate of oxytetracycline depended on pH and applied ozone dose, but not initial antibiotic concentration in wastewater. In the case of manure treatment, ozonation efficiency in terms of oxytetracycline degradation was negatively affected by moisture and antibiotic content of manure. The degradation rate of oxytetracycline in manure slowed down upon the extension of treatment time since ozone could not react with strongly adsorbed antibiotic on manure. Increase in humic and fulvic acid carbon and mineral nitrogen content was an indicator for the improvement of fertilizing value of manure by ozonation.
- 1 January 2008
- Published by Sycamore Global Publications in Journal of Advanced Oxidation Technologies
- Vol. 11 (3)
Homogeneous and Heterogeneous Catalytic Ozonation of Pulp Bleaching Effluent
Catalytic ozonation is a promising treatment method for both water and wastewater. In this study, in order to increase the biodegradability of bleaching wastewater from an integrated pulp- and -paper production plant, granulated activated carbon-(GAC), iron-(Fe
- 1 January 2008
- Published by Sycamore Global Publications in Journal of Advanced Oxidation Technologies
- Vol. 11 (3)
Homogeneous and Heterogeneous Catalytic Ozonation of Pulp Bleaching Effluent
Catalytic ozonation is a promising treatment method for both water and wastewater. In this study, in order to increase the biodegradability of bleaching wastewater from an integrated pulp- and -paper production plant, granulated activated carbon-(GAC), iron-(Fe
- 1 December 2007
- Published by Elsevier in Journal of Environmental Management
- Vol. 85 (4) , 918-926
Merits of ozonation and catalytic ozonation pre-treatment in the algal treatment of pulp and paper mill effluents
- 1 December 2007
- Published by Elsevier in Journal of Environmental Management
- Vol. 85 (4) , 918-926
Merits of ozonation and catalytic ozonation pre-treatment in the algal treatment of pulp and paper mill effluents