Bai-Chuang Shyu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Bai-Chuang Shyu has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Chen Chang
Institute of Biomedical Sciences, Academia Sinica, Taipei 115, Taiwan, ROC
2 shared publications- Chun-Yu Lin
Department of Psychology, National Cheng Kung University
2 shared publications - Jyh-Jang Sun
NERF, Kapeldreef 75, 3001 Leuven, Belgium; imec, Remisebosweg 1, 3001 Leuven, Belgium
2 shared publications Jen-Chuang Kung
Institute of Biomedical Sciences, Academia Sinica, Taipei 115, Taiwan, ROC
1 shared publicationRuey-Jane Fan
Institute of Biomedical Sciences, Academia Sinica, Taipei 115, Taiwan, ROC
1 shared publication- Sergiy Sylantyev
Rowett Institute, University of Aberdeen, Aberdeen, UK
1 shared publication
Latest Publications
- 15 August 2004
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 137 (1) , 123-131
A method for direct thalamic stimulation in fMRI studies using a glass-coated carbon fiber electrode
- 15 August 2004
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 137 (1) , 123-131
A method for direct thalamic stimulation in fMRI studies using a glass-coated carbon fiber electrode
- Open Access
- 28 June 2004
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 52 (1) , 47-55
BOLD response to direct thalamic stimulation reveals a functional connection between the medial thalamus and the anterior cingulate cortex in the rat
Recent functional neuroimaging studies in humans and rodents have shown that the anterior cingulate cortex (ACC) is activated by painful stimuli, and plays an important role in the affective aspect of pain sensation. The aim of the present study was to develop a suitable stimulation method for direct activation of the brain in fMRI studies and to investigate the functional connectivity in the thalamo‐cingulate pathway. In the first part of the study, tungsten, stainless steel, or glass‐coated carbon fiber microelectrodes were implanted in the left medial thalamus (MT) of anesthetized rats, and T2*‐weighted gradient‐echo (GE) images were obtained in the sagittal plane on a 4.7 T system (Biospec BMT 47/40). Only the images obtained with the carbon fiber electrode were acceptable without a reduction of the signal‐to‐noise ratio (SNR) and image distortion. In the second part of the study, a series of two‐slice GE images were acquired during electrical stimulation of the MT with the use of a carbon fiber electrode. A cross‐correlation analysis showed that the signal intensities of activated areas in the ipsilateral ACC were significantly increased by about 4.5% during MT stimulation. Functional activation, as assessed by the distribution of c‐Fos immunoreactivity, showed strong c‐Fos expression in neurons in the ipsilateral ACC. The present study shows that glass‐coated carbon fiber electrodes are suitable for fMRI studies and can be used to investigate functional thalamocortical activation. Magn Reson Med 52:47–55, 2004.
- 28 June 2004
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 52 (1) , 47-55
Open AccessBOLD response to direct thalamic stimulation reveals a functional connection between the medial thalamus and the anterior cingulate cortex in the rat
Recent functional neuroimaging studies in humans and rodents have shown that the anterior cingulate cortex (ACC) is activated by painful stimuli, and plays an important role in the affective aspect of pain sensation. The aim of the present study was to develop a suitable stimulation method for direct activation of the brain in fMRI studies and to investigate the functional connectivity in the thalamo‐cingulate pathway. In the first part of the study, tungsten, stainless steel, or glass‐coated carbon fiber microelectrodes were implanted in the left medial thalamus (MT) of anesthetized rats, and T2*‐weighted gradient‐echo (GE) images were obtained in the sagittal plane on a 4.7 T system (Biospec BMT 47/40). Only the images obtained with the carbon fiber electrode were acceptable without a reduction of the signal‐to‐noise ratio (SNR) and image distortion. In the second part of the study, a series of two‐slice GE images were acquired during electrical stimulation of the MT with the use of a carbon fiber electrode. A cross‐correlation analysis showed that the signal intensities of activated areas in the ipsilateral ACC were significantly increased by about 4.5% during MT stimulation. Functional activation, as assessed by the distribution of c‐Fos immunoreactivity, showed strong c‐Fos expression in neurons in the ipsilateral ACC. The present study shows that glass‐coated carbon fiber electrodes are suitable for fMRI studies and can be used to investigate functional thalamocortical activation. Magn Reson Med 52:47–55, 2004.
- 25 June 2003
- Published by Elsevier in Brain Research Protocols
- Vol. 12 (1) , 1-9
A quantitative method for assessing of the affective component of the pain: conditioned response associated with CO2 laser-induced nocifensive reaction
- 25 June 2003
- Published by Elsevier in Brain Research Protocols
- Vol. 12 (1) , 1-9
A quantitative method for assessing of the affective component of the pain: conditioned response associated with CO2 laser-induced nocifensive reaction
- Open Access
- 1 August 1997
- Published by Oxford University Press (OUP) in Physical Therapy
- Vol. 77 (8) , 839-847
The Suppressive Effect of Electrical Stimulation on Nociceptive Responses in the Rat
Background and Purpose. The aim of this investigation was to study the effect of electrical stimulation on nociceptive responses within the lumbar levels of the rat spinal cord. Methods. A single high-energy thermal pulse produced by a surgical laser stimulator (5 W, 30 milliseconds) was applied on the plantar surface of the hind paws of male Sprague-Dawley rats. The spinal cord field potential evoked by the laser pulse was used as an indicator of thermosensitve nociceptive responses. Low-intensity single stimulation, high-intensity single stimulation, low-intensity train stimulation, and high-intensity train stimulation were applied on the common peroneal nerve with protected cuff electrodes in different trials. Results. Neither low-intensity nor high-intensity single stimulation suppressed field potentials. In contrast, low-intensity train stimulation elicited partial inhibition of field potentials. Furthermore, high-intensity train stimulation elicited biphasic inhibition at a wider range of intervals lasting for 20 seconds. Conclusion and Discussion. The results demonstrate that two modes of train electrical stimulation can produce two patterns of fast-onset (within milliseconds), short-duration (within 20 seconds) inhibition of field potentials in the spinal cord. These results provide evidence that noxious heat-related impulses are modulated by the presence of specific electrical stimulation. The clinical application of transcutaneous electrical nerve stimulation to block pain is supported.
- 1 August 1997
- Published by Oxford University Press (OUP) in Physical Therapy
- Vol. 77 (8) , 839-847
Open AccessThe Suppressive Effect of Electrical Stimulation on Nociceptive Responses in the Rat
Background and Purpose. The aim of this investigation was to study the effect of electrical stimulation on nociceptive responses within the lumbar levels of the rat spinal cord. Methods. A single high-energy thermal pulse produced by a surgical laser stimulator (5 W, 30 milliseconds) was applied on the plantar surface of the hind paws of male Sprague-Dawley rats. The spinal cord field potential evoked by the laser pulse was used as an indicator of thermosensitve nociceptive responses. Low-intensity single stimulation, high-intensity single stimulation, low-intensity train stimulation, and high-intensity train stimulation were applied on the common peroneal nerve with protected cuff electrodes in different trials. Results. Neither low-intensity nor high-intensity single stimulation suppressed field potentials. In contrast, low-intensity train stimulation elicited partial inhibition of field potentials. Furthermore, high-intensity train stimulation elicited biphasic inhibition at a wider range of intervals lasting for 20 seconds. Conclusion and Discussion. The results demonstrate that two modes of train electrical stimulation can produce two patterns of fast-onset (within milliseconds), short-duration (within 20 seconds) inhibition of field potentials in the spinal cord. These results provide evidence that noxious heat-related impulses are modulated by the presence of specific electrical stimulation. The clinical application of transcutaneous electrical nerve stimulation to block pain is supported.