Youssef Ibrahim Moharram
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Youssef Ibrahim Moharram has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Ibrahim S. El-Hallag
3 shared publicationsAbeer A. A. Khamis
Biochemistry Division, Department of Chemistry, Faculty of Science, Tanta University, Tanta, Egypt
2 shared publicationsAhmed R. Tartour
Central Metallurgical Research and Development Institute, Helwan, EGYPT
2 shared publicationsAmira M. Hassanein
Analytical and Electrochemistry Research Unit, Department of Chemistry, Faculty of Science, Tanta University, Tanta, Egypt
2 shared publicationsMohammed E. Sadek
Applied Organic Chemistry, Department of Chemistry, Faculty of Science, Tanta University, Tanta, Egypt
2 shared publications- Moustafa M. S. Sanad
Central Metallurgical Research & Development Institute, Cairo, Egypt
2 shared publications
Latest Publications
- 13 December 2024
- Published by Elsevier in Surfaces and Interfaces
- Vol. 56
Emerging of SnO2-V2O5-Cu nanocomposite as effective electrode materials for supercabatteries and HER in alkaline medium
- 13 December 2024
- Published by Elsevier in Surfaces and Interfaces
- Vol. 56
Emerging of SnO2-V2O5-Cu nanocomposite as effective electrode materials for supercabatteries and HER in alkaline medium
- Open Access
- 12 July 2024
- Published by Springer Nature in Journal of Applied Electrochemistry
- Vol. 54 (12) , 2855-2870
Electro-generating Cu2+ ions based on electrochemically modified CPE for the determination of malathion pesticide using valid SW-ASV method
This work investigates the validation of the SW-ASV method for the determination of malathion organophosphorus pesticide based on an electrochemically modified (CPE) carbon paste electrode with copper metal. The surface of the modified CPE was constructed by electrodepositing the copper layer at the accumulation step in 1-mM CuSO4.5H2O, PBS at pH 6.6, E accumulation: − 0.8 V, and Taccumulation 240 s. The determining step was performed by adding different concentrations of malathion pesticide and applying the potential toward more positive potential at (− 0.8–+ 1.4 V) to enhance the oxidation of Cu0 metal. It was noticed that the malathion concentration gradient enhances the oxidation peak current of copper at + 0.03 V gradually. SW-ASV method validation was performed at a linearity range confined in (1–10 µM). An analytical curve was constructed and R2 was equal to 0.99995 with good fitted linear relationship. LOD and LOQ were calculated to be 0.0247 and 0.08236 µM, respectively. ANOVA for two sets of measurements using the standard gas chromatographic method and the suggested SW-ASV method was demonstrated via the calculations of F-value and t-value. F and t-values were calculated to be 1.698 and 0.289, respectively, which did not exceed the tabulated F and t-values resulting in the great similarity of results and ensuring the reliability of the suggested test method. This valid SW-ASV method was used to perform the routine analysis of the 95% technical grade and the pesticide formulation 57% emulsion concentrate of the malathion. Valid results were achieved with satisfactory limits of accuracy and precision. Graphical abstract
- 12 July 2024
- Published by Springer Nature in Journal of Applied Electrochemistry
- Vol. 54 (12) , 2855-2870
Open AccessElectro-generating Cu2+ ions based on electrochemically modified CPE for the determination of malathion pesticide using valid SW-ASV method
This work investigates the validation of the SW-ASV method for the determination of malathion organophosphorus pesticide based on an electrochemically modified (CPE) carbon paste electrode with copper metal. The surface of the modified CPE was constructed by electrodepositing the copper layer at the accumulation step in 1-mM CuSO4.5H2O, PBS at pH 6.6, E accumulation: − 0.8 V, and Taccumulation 240 s. The determining step was performed by adding different concentrations of malathion pesticide and applying the potential toward more positive potential at (− 0.8–+ 1.4 V) to enhance the oxidation of Cu0 metal. It was noticed that the malathion concentration gradient enhances the oxidation peak current of copper at + 0.03 V gradually. SW-ASV method validation was performed at a linearity range confined in (1–10 µM). An analytical curve was constructed and R2 was equal to 0.99995 with good fitted linear relationship. LOD and LOQ were calculated to be 0.0247 and 0.08236 µM, respectively. ANOVA for two sets of measurements using the standard gas chromatographic method and the suggested SW-ASV method was demonstrated via the calculations of F-value and t-value. F and t-values were calculated to be 1.698 and 0.289, respectively, which did not exceed the tabulated F and t-values resulting in the great similarity of results and ensuring the reliability of the suggested test method. This valid SW-ASV method was used to perform the routine analysis of the 95% technical grade and the pesticide formulation 57% emulsion concentrate of the malathion. Valid results were achieved with satisfactory limits of accuracy and precision. Graphical abstract
- Open Access
- 26 February 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-16
Novel mixed heterovalent (Mo/Co)Ox-zerovalent Cu system as bi-functional electrocatalyst for overall water splitting
A novel hybrid ternary metallic electrocatalyst of amorphous Mo/Co oxides and crystallized Cu metal was deposited over Ni foam using a one-pot, simple, and scalable solvothermal technique. The chemical structure of the prepared ternary electrocatalyst was systematically characterized and confirmed via XRD, FTIR, EDS, and XPS analysis techniques. FESEM images of (Mo/Co)Ox–Cu@NF display the formation of 3D hierarchical structure with a particle size range of 3–5 µm. The developed (Mo/Co)Ox–Cu@NF ternary electrocatalyst exhibits the maximum activity with 188 mV and 410 mV overpotentials at 50 mA cm−2 for hydrogen evolution reaction (HER) and oxygen evolution reaction (OER), respectively. Electrochemical impedance spectroscopy (EIS) results for the (Mo/Co)Ox–Cu@NF sample demonstrate the minimum charge transfer resistance (Rct) and maximum constant phase element (CPE) values. A two-electrode cell based on the ternary electrocatalyst just needs a voltage of about 1.86 V at 50 mA cm−2 for overall water splitting (OWS). The electrocatalyst shows satisfactory durability during the OWS for 24 h at 10 mA cm−2 with an increase of only 33 mV in the cell potential.
- 26 February 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-16
Open AccessNovel mixed heterovalent (Mo/Co)Ox-zerovalent Cu system as bi-functional electrocatalyst for overall water splitting
A novel hybrid ternary metallic electrocatalyst of amorphous Mo/Co oxides and crystallized Cu metal was deposited over Ni foam using a one-pot, simple, and scalable solvothermal technique. The chemical structure of the prepared ternary electrocatalyst was systematically characterized and confirmed via XRD, FTIR, EDS, and XPS analysis techniques. FESEM images of (Mo/Co)Ox–Cu@NF display the formation of 3D hierarchical structure with a particle size range of 3–5 µm. The developed (Mo/Co)Ox–Cu@NF ternary electrocatalyst exhibits the maximum activity with 188 mV and 410 mV overpotentials at 50 mA cm−2 for hydrogen evolution reaction (HER) and oxygen evolution reaction (OER), respectively. Electrochemical impedance spectroscopy (EIS) results for the (Mo/Co)Ox–Cu@NF sample demonstrate the minimum charge transfer resistance (Rct) and maximum constant phase element (CPE) values. A two-electrode cell based on the ternary electrocatalyst just needs a voltage of about 1.86 V at 50 mA cm−2 for overall water splitting (OWS). The electrocatalyst shows satisfactory durability during the OWS for 24 h at 10 mA cm−2 with an increase of only 33 mV in the cell potential.
- Open Access
- 20 December 2023
- Published by Springer Nature in Research Square
Electro Generating Cu+2 Ions Based on Electrochemically Modified CPE for The Determination of Malathion Pesticide using Valid SW-ASV Method
This work investigates the validation of SW-ASV method for the determination of malathion organophosphorus pesticide based on electrochemically modified CPE with copper metal. The surface of the modified CPE was constructed by electrodepositing copper layer at the accumulation step in 1mM CuSO4.5H2O, PBS at pH 6.6, E accumulation: -0.8 V, and T accumulation 240 s. The determining step was performed by adding different concentrations of malathion pesticide and applied the potential towards more positive potential at (-0.8 - +1.4 V) to enhance the oxidation of Cu0 metal. It was noticed that the malathion concentrations gradient enhances the oxidation peak current of copper at + 0.03V gradually. This was the paradigm for developing SW-ASV method and investigation of the method validation. SW-ASV method validation was performed in PBS at pH 6.6, potential window (-0.8 - +1.4 V), E accumulation: -0.8 V, T accumulation 240 s, and linearity range of malathion concentrations confined in (0–10µM). The calibration curve was constructed and R2 was equal to 0.99995 with good fitted linear relationship. LOD and LOQ were calculated to be 0.0247, and 0.08236 µM respectively. the raggedness of the test method was verified towards the deliberate variations for the CuSO4.5H2O concentration which closely varied to be (0.9, 1, and 1.1 mM) in accumulation step. Insignificant differences were observed between taken and measured concentration values of malathion. ANOVA for two sets of measurements using the standard GLC method and the suggested SW-ASV electroanalytical method was demonstrated via the calculations of F-value and t-value. F and t- values were calculated to be 1.698 and 0.289 respectively which not exceeded the tabulated F and t- values at degree of freedom equal to 4, resulting in the great similarity of results and ensuring the reliability of the suggested test method. The suggested SW-ASV method was used to perform the quality control routine analysis of the technical grade (95% - TC) and the pesticide formulation (57% - EC) of the malathion. Valid results were achieved with satisfactory limits of accuracy and precision.
- 20 December 2023
- Published by Springer Nature in Research Square
Open AccessElectro Generating Cu+2 Ions Based on Electrochemically Modified CPE for The Determination of Malathion Pesticide using Valid SW-ASV Method
This work investigates the validation of SW-ASV method for the determination of malathion organophosphorus pesticide based on electrochemically modified CPE with copper metal. The surface of the modified CPE was constructed by electrodepositing copper layer at the accumulation step in 1mM CuSO4.5H2O, PBS at pH 6.6, E accumulation: -0.8 V, and T accumulation 240 s. The determining step was performed by adding different concentrations of malathion pesticide and applied the potential towards more positive potential at (-0.8 - +1.4 V) to enhance the oxidation of Cu0 metal. It was noticed that the malathion concentrations gradient enhances the oxidation peak current of copper at + 0.03V gradually. This was the paradigm for developing SW-ASV method and investigation of the method validation. SW-ASV method validation was performed in PBS at pH 6.6, potential window (-0.8 - +1.4 V), E accumulation: -0.8 V, T accumulation 240 s, and linearity range of malathion concentrations confined in (0–10µM). The calibration curve was constructed and R2 was equal to 0.99995 with good fitted linear relationship. LOD and LOQ were calculated to be 0.0247, and 0.08236 µM respectively. the raggedness of the test method was verified towards the deliberate variations for the CuSO4.5H2O concentration which closely varied to be (0.9, 1, and 1.1 mM) in accumulation step. Insignificant differences were observed between taken and measured concentration values of malathion. ANOVA for two sets of measurements using the standard GLC method and the suggested SW-ASV electroanalytical method was demonstrated via the calculations of F-value and t-value. F and t- values were calculated to be 1.698 and 0.289 respectively which not exceeded the tabulated F and t- values at degree of freedom equal to 4, resulting in the great similarity of results and ensuring the reliability of the suggested test method. The suggested SW-ASV method was used to perform the quality control routine analysis of the technical grade (95% - TC) and the pesticide formulation (57% - EC) of the malathion. Valid results were achieved with satisfactory limits of accuracy and precision.
- Open Access
- 17 March 2023
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 20 (7) , 1503-1522
Voltammetric quantitative analysis of vildagliptin in bulk form and spiked human serum at a modified electrode
The electrochemical behavior of Vildagliptin (VILD) was studied using the cyclic voltammetric technique in an aqueous Britton–Robinson (BR) universal buffer solution of various pH levels between 4.0 and 10 at a 5% calcium-montmorillonite clay modified with carbon paste electrode surface (5% Ca-MMT/CPE). The results exhibited an irreversible anodic peak at about 1.238 V versus Ag/AgCl, KCl (3 mol L−1). The anodic peak was found to be diffusion–adsorption controlled. The possible reaction mechanism is estimated taking into consideration of the calculated electrons and protons number transferred on the electrode/electrolyte interface using the cyclic voltammetric technique. VILD was found to adsorb onto the surface of 5% Ca-MMT/CPE in a monolayer surface coverage of 3.0 × 10−12 mol cm−2. A validated square wave voltammetry (SWV) technique for VILD determination was performed. The calibration curve of VILD onto the 5% Ca-MMT/CPE surface was linear in the concentration range of 1.0–110 nmol L−1 with the mean limits of detection and quantification was 0.285 and 0.950 nmol L−1, respectively, in the bulk form. The proposed procedure for the assay of VILD in bulk form, dosage form, and spiked human serum has the advantage of being simple, rapid, sensitive, and inexpensive compared to other analytical methods. The described method showed an excellent performance for the trace determination of VILD in its formulation without interference from excipients. Graphical abstract
- 17 March 2023
- Published by Springer Nature in Journal of the Iranian Chemical Society
- Vol. 20 (7) , 1503-1522
Open AccessVoltammetric quantitative analysis of vildagliptin in bulk form and spiked human serum at a modified electrode
The electrochemical behavior of Vildagliptin (VILD) was studied using the cyclic voltammetric technique in an aqueous Britton–Robinson (BR) universal buffer solution of various pH levels between 4.0 and 10 at a 5% calcium-montmorillonite clay modified with carbon paste electrode surface (5% Ca-MMT/CPE). The results exhibited an irreversible anodic peak at about 1.238 V versus Ag/AgCl, KCl (3 mol L−1). The anodic peak was found to be diffusion–adsorption controlled. The possible reaction mechanism is estimated taking into consideration of the calculated electrons and protons number transferred on the electrode/electrolyte interface using the cyclic voltammetric technique. VILD was found to adsorb onto the surface of 5% Ca-MMT/CPE in a monolayer surface coverage of 3.0 × 10−12 mol cm−2. A validated square wave voltammetry (SWV) technique for VILD determination was performed. The calibration curve of VILD onto the 5% Ca-MMT/CPE surface was linear in the concentration range of 1.0–110 nmol L−1 with the mean limits of detection and quantification was 0.285 and 0.950 nmol L−1, respectively, in the bulk form. The proposed procedure for the assay of VILD in bulk form, dosage form, and spiked human serum has the advantage of being simple, rapid, sensitive, and inexpensive compared to other analytical methods. The described method showed an excellent performance for the trace determination of VILD in its formulation without interference from excipients. Graphical abstract
- 2 July 2022
- Published by Springer Nature in Journal of Applied Electrochemistry
- Vol. 52 (10) , 1491-1511
Voltammetric assay of vildagliptin drug as vildagliptin-Cu2+ complex and its biological applications
- 2 July 2022
- Published by Springer Nature in Journal of Applied Electrochemistry
- Vol. 52 (10) , 1491-1511
Voltammetric assay of vildagliptin drug as vildagliptin-Cu2+ complex and its biological applications
- 1 June 2021
- Published by Pleiades Publishing Ltd in Russian Journal of Electrochemistry
- Vol. 57 (6) , 644-653
Quantitative Evaluation of Generic Glyphosate Using Carbon Paste Electrode Electrochemically Modified with Copper Ions
Generic products are not identical to their branded equivalents. They are typically off-patent. Therefore, this paper suggests a selective, reliable, and accurate electrochemical method for quantifying the original and generic glyphosate from Monsanto Roundup®—USA and Rotam Agrochemicals—Hong Kong. The reliability of the suggested electroanalytical method was assured. An electrochemically modified carbon paste electrode was used as a working electrode. This working electrode was constructed by depositing a copper layer electrochemically using chronoamperometry under continuous stirring. The copper deposition was conducted for 180 s at the potential of –0.8 V from an aqueous solution of copper sulphate pentahydrate at pH 6.5. Adjust by adding phosphate buffer. Cyclic voltammograms for electrochemically modified CPE versus Ag/AgCl were recorded between (–0.8…–1.4 V) at a scan rate of 0.1 V s–1 in solutions with and without glyphosate. The results showed an enhancing in the oxidation peak current of the copper previously deposited on CPE by the addition of glyphosate. This enhancing in copper oxidation peak may be attributed to glyphosate adsorption on the surface of the electrode and formation of a complex. SW-ASV method was used as an efficient electroanalytical technique for glyphosate quantification. The operating parameters such as accumulation potential and accumulation time were optimized to give maximum oxidation peak current of copper. Calibration curves were constructed in a concentration range (2 × 10–6–2 × 10–4 mol L–1) for generic, original and standard glyphosate. Calibration curve method was adopted in a comparison. It was observed that there are very minor differences in the slopes of generic, original, and standard glyphosate (0.2982–0.2993–0.2957 μA/μM) respectively.
- 1 June 2021
- Published by Pleiades Publishing Ltd in Russian Journal of Electrochemistry
- Vol. 57 (6) , 644-653
Quantitative Evaluation of Generic Glyphosate Using Carbon Paste Electrode Electrochemically Modified with Copper Ions
Generic products are not identical to their branded equivalents. They are typically off-patent. Therefore, this paper suggests a selective, reliable, and accurate electrochemical method for quantifying the original and generic glyphosate from Monsanto Roundup®—USA and Rotam Agrochemicals—Hong Kong. The reliability of the suggested electroanalytical method was assured. An electrochemically modified carbon paste electrode was used as a working electrode. This working electrode was constructed by depositing a copper layer electrochemically using chronoamperometry under continuous stirring. The copper deposition was conducted for 180 s at the potential of –0.8 V from an aqueous solution of copper sulphate pentahydrate at pH 6.5. Adjust by adding phosphate buffer. Cyclic voltammograms for electrochemically modified CPE versus Ag/AgCl were recorded between (–0.8…–1.4 V) at a scan rate of 0.1 V s–1 in solutions with and without glyphosate. The results showed an enhancing in the oxidation peak current of the copper previously deposited on CPE by the addition of glyphosate. This enhancing in copper oxidation peak may be attributed to glyphosate adsorption on the surface of the electrode and formation of a complex. SW-ASV method was used as an efficient electroanalytical technique for glyphosate quantification. The operating parameters such as accumulation potential and accumulation time were optimized to give maximum oxidation peak current of copper. Calibration curves were constructed in a concentration range (2 × 10–6–2 × 10–4 mol L–1) for generic, original and standard glyphosate. Calibration curve method was adopted in a comparison. It was observed that there are very minor differences in the slopes of generic, original, and standard glyphosate (0.2982–0.2993–0.2957 μA/μM) respectively.
- Open Access
- 31 August 2020
- Published by The Korean Electrochemical Society - English Journal in Journal of Electrochemical Science and Technology
- Vol. 11 (3) , 291-309
Factors Affecting Nucleation and Growth of Chromium Electrodeposited from Cr3+ Electrolytes Based on Deep Eutectic Solvents
- 31 August 2020
- Published by The Korean Electrochemical Society - English Journal in Journal of Electrochemical Science and Technology
- Vol. 11 (3) , 291-309
Open AccessFactors Affecting Nucleation and Growth of Chromium Electrodeposited from Cr3+ Electrolytes Based on Deep Eutectic Solvents
- 6 September 2006
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 43 (2) , 499-505
Voltammetry and quantification of the contraceptive drug norethisterone in bulk form and pharmaceutical formulation
- 6 September 2006
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 43 (2) , 499-505
Voltammetry and quantification of the contraceptive drug norethisterone in bulk form and pharmaceutical formulation
- 1 March 2004
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 563 (2) , 283-290
Determination of the chemical and electrochemical parameters for a CE system by methods of convolution electrochemistry
- 1 March 2004
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 563 (2) , 283-290
Determination of the chemical and electrochemical parameters for a CE system by methods of convolution electrochemistry