Stacey S. Hickson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Stacey S. Hickson has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Carmel M McEniery
3 shared publicationsIan B Wilkinson
3 shared publications- Mark Butlin
Macquarie Medical School, Faculty of Medicine, Health and Human Sciences, Macquarie University, Sydney, Australia
3 shared publications - Alberto Avolio
Macquarie Medical School, Faculty of Medicine, Health and Human Sciences, Macquarie University, Sydney, Australia
2 shared publications John R Cockcroft
2 shared publicationsYasmin
2 shared publications
Latest Publications
- 1 June 2011
- Published by Wolters Kluwer Health in Journal Of Hypertension
- Vol. 29 (6) , 1155-1159
Use of the oral contraceptive pill is associated with increased large artery stiffness in young women: The ENIGMA Study
Background The oral contraceptive pill (OCP) is widely prescribed throughout the world. Although it is associated with a small but significant increase in blood pressure, the influence of the OCP on large artery stiffness and wave reflection is unclear. The aim of this study was to determine the relationship between use of the OCP and aortic stiffness and wave reflections in a young, healthy cohort of women. Methods Participants were drawn from the ENIGMA study, which examines the natural history of blood pressure in young adults. A detailed medical history and lifestyle questionnaire, including OCP details were taken. Blood pressure was measured according to the British Hypertension Society guidelines. Aortic pulse wave velocity (aPWV) was measured together with augmentation index (AIx). Stroke volume (SV) and cardiac output (CO) were also assessed. Results Women taking the OCP (n = 225) had a higher SBP and pulse pressure compared with nonusers (n = 660; 112 ± 12 vs. 110 ± 11 and 43 ± 8 vs. 42 ± 8 mmHg, respectively, P < 0.05 for both). CO and SV were also higher (6.6 ± 1.5 vs. 6.3 ± 1.5 l/min, P < 0.01 and 81 ± 16 vs. 78 ± 19 ml, P < 0.05) as was aPWV (5.5 ± 0.7 vs. 5.4 ± 0.7 m/s, P < 0.05). However, there was no difference in DBP (68 ± 9 vs. 69 ± 9 mmHg), mean arterial pressure (81 ± 10 vs. 81 ± 10 mmHg) or AIx (2 ± 12 vs. 3 ± 13%) between the groups. Conclusion Use of the OCP is associated with elevated pulse pressure and SV and a small increase in aPWV in young women. The longer term implications of these effects require further investigation.
- 1 June 2011
- Published by Wolters Kluwer Health in Journal Of Hypertension
- Vol. 29 (6) , 1155-1159
Use of the oral contraceptive pill is associated with increased large artery stiffness in young women: The ENIGMA Study
Background The oral contraceptive pill (OCP) is widely prescribed throughout the world. Although it is associated with a small but significant increase in blood pressure, the influence of the OCP on large artery stiffness and wave reflection is unclear. The aim of this study was to determine the relationship between use of the OCP and aortic stiffness and wave reflections in a young, healthy cohort of women. Methods Participants were drawn from the ENIGMA study, which examines the natural history of blood pressure in young adults. A detailed medical history and lifestyle questionnaire, including OCP details were taken. Blood pressure was measured according to the British Hypertension Society guidelines. Aortic pulse wave velocity (aPWV) was measured together with augmentation index (AIx). Stroke volume (SV) and cardiac output (CO) were also assessed. Results Women taking the OCP (n = 225) had a higher SBP and pulse pressure compared with nonusers (n = 660; 112 ± 12 vs. 110 ± 11 and 43 ± 8 vs. 42 ± 8 mmHg, respectively, P < 0.05 for both). CO and SV were also higher (6.6 ± 1.5 vs. 6.3 ± 1.5 l/min, P < 0.01 and 81 ± 16 vs. 78 ± 19 ml, P < 0.05) as was aPWV (5.5 ± 0.7 vs. 5.4 ± 0.7 m/s, P < 0.05). However, there was no difference in DBP (68 ± 9 vs. 69 ± 9 mmHg), mean arterial pressure (81 ± 10 vs. 81 ± 10 mmHg) or AIx (2 ± 12 vs. 3 ± 13%) between the groups. Conclusion Use of the OCP is associated with elevated pulse pressure and SV and a small increase in aPWV in young women. The longer term implications of these effects require further investigation.
- 1 December 2010
- Published by Elsevier in JACC: Cardiovascular Imaging
- Vol. 3 (12) , 1247-1255
The Relationship of Age With Regional Aortic Stiffness and Diameter
- 1 December 2010
- Published by Elsevier in JACC: Cardiovascular Imaging
- Vol. 3 (12) , 1247-1255
The Relationship of Age With Regional Aortic Stiffness and Diameter
- 25 September 2009
- Published by Springer Nature in Hypertension Research
- Vol. 32 (12) , 1079-1085
Validity and repeatability of the Vicorder apparatus: a comparison with the SphygmoCor device
Aortic stiffness, an independent predictor of cardiovascular risk and all-cause mortality, can be estimated non-invasively by measuring carotid to femoral (aortic) pulse wave velocity (aPWV). The Vicorder device has been developed to measure aPWV with little operator training in a non-intrusive manner. The aim of this study was to assess the repeatability of aPWV measured with the Vicorder device and to compare aPWV values with those obtained using the SphygmoCor system. Vicorder and SphygmoCor aPWV was assessed in 122 subjects (53±18 years, 46 male) using both the manufacturers' and a standardized approach. Vicorder aPWV measurement proved to be highly repeatable (within-subject coefficient of variation 2.8%). Transit time differed significantly between the two devices (mean difference 22±9 ms, P−1, PP<0.001). Transit time values significantly differed between the two devices and the Vicorder device reported lower aPWV values at higher SphygmoCor values of aPWV. This difference in transit time and inherent bias was reduced when adjustment for the additional femoral artery segment measured by the Vicorder device was made.
- 25 September 2009
- Published by Springer Nature in Hypertension Research
- Vol. 32 (12) , 1079-1085
Validity and repeatability of the Vicorder apparatus: a comparison with the SphygmoCor device
Aortic stiffness, an independent predictor of cardiovascular risk and all-cause mortality, can be estimated non-invasively by measuring carotid to femoral (aortic) pulse wave velocity (aPWV). The Vicorder device has been developed to measure aPWV with little operator training in a non-intrusive manner. The aim of this study was to assess the repeatability of aPWV measured with the Vicorder device and to compare aPWV values with those obtained using the SphygmoCor system. Vicorder and SphygmoCor aPWV was assessed in 122 subjects (53±18 years, 46 male) using both the manufacturers' and a standardized approach. Vicorder aPWV measurement proved to be highly repeatable (within-subject coefficient of variation 2.8%). Transit time differed significantly between the two devices (mean difference 22±9 ms, P−1, PP<0.001). Transit time values significantly differed between the two devices and the Vicorder device reported lower aPWV values at higher SphygmoCor values of aPWV. This difference in transit time and inherent bias was reduced when adjustment for the additional femoral artery segment measured by the Vicorder device was made.
- 1 September 2009
- Published by Wolters Kluwer Health in Journal Of Hypertension
- Vol. 27 (9) , 1784-1788
The accuracy of central SBP determined from the second systolic peak of the peripheral pressure waveform
Recent evidence suggests that central aortic blood pressure may be a better predictor of cardiovascular risk than peripheral blood pressure. The central SBP (cSBP) can be estimated from the late systolic shoulder of the radial pulse waveform. We compared the second systolic peak of the radial waveform (pSBP2) with the central systolic pressure derived by a generalized transfer function in a large cohort, across a wide age range, of patients from the Anglo-Cardiff Collaborative Trial. We also compared pSBP2 with the true cSBP measured by cardiac catheterization [invasively measured cSBP (cSBPi)]. Noninvasive measurements were made by applanation tonometry using the SphygmoCor device. The aortic pressure waveform was derived from the radial waveform using a validated transfer function. Invasive measures of cSBPi were carried out in a group of 38 patients undergoing diagnostic cardiac angiography, and radial artery pressure waveforms were simultaneously recorded using the SphygmoCor device. Overall, there was a strong correlation (r = 0.99, P < 0.001) and good agreement between pSBP2 and the derived cSBP (mean difference ± SD 1 ± 4 mmHg). However, there was a systematic bias with a greater difference between these measures at lower average pressures. There was also a strong correlation and good agreement between the invasively measured cSBPi and pSBP2 (r = 0.92, P < 0.001, mean difference 2 ± 6 mmHg). The second systolic shoulder of the peripheral pressure waveform approximates the cSBP in a large cohort of patients across a wide age range, but this may be inaccurate at low SBP values.
- 1 September 2009
- Published by Wolters Kluwer Health in Journal Of Hypertension
- Vol. 27 (9) , 1784-1788
The accuracy of central SBP determined from the second systolic peak of the peripheral pressure waveform
Recent evidence suggests that central aortic blood pressure may be a better predictor of cardiovascular risk than peripheral blood pressure. The central SBP (cSBP) can be estimated from the late systolic shoulder of the radial pulse waveform. We compared the second systolic peak of the radial waveform (pSBP2) with the central systolic pressure derived by a generalized transfer function in a large cohort, across a wide age range, of patients from the Anglo-Cardiff Collaborative Trial. We also compared pSBP2 with the true cSBP measured by cardiac catheterization [invasively measured cSBP (cSBPi)]. Noninvasive measurements were made by applanation tonometry using the SphygmoCor device. The aortic pressure waveform was derived from the radial waveform using a validated transfer function. Invasive measures of cSBPi were carried out in a group of 38 patients undergoing diagnostic cardiac angiography, and radial artery pressure waveforms were simultaneously recorded using the SphygmoCor device. Overall, there was a strong correlation (r = 0.99, P < 0.001) and good agreement between pSBP2 and the derived cSBP (mean difference ± SD 1 ± 4 mmHg). However, there was a systematic bias with a greater difference between these measures at lower average pressures. There was also a strong correlation and good agreement between the invasively measured cSBPi and pSBP2 (r = 0.92, P < 0.001, mean difference 2 ± 6 mmHg). The second systolic shoulder of the peripheral pressure waveform approximates the cSBP in a large cohort of patients across a wide age range, but this may be inaccurate at low SBP values.