Arthur F. T. Mak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Arthur F. T. Mak has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Jiashen Li
Jockey Club Rehabilitation Engineering Center, The Hong Kong Polytechnic University, Hong Hum, Kowloon, Hong Kong, China
2 shared publications- Min Wang
The University of Hong Kong
2 shared publications - Yong-Ping Zheng
Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR, China
2 shared publications Yun Chen
Jockey Club Rehabilitation Engineering Center, The Hong Kong Polytechnic University, Hong Hum, Kowloon, Hong Kong, China
2 shared publicationsAnita W. T. Shum
Jockey Club Rehabilitation Engineering Center, The Hong Kong Polytechnic University, Hong Hum, Kowloon, Hong Kong, China
1 shared publicationBonnie Y. S. Tsung
1 shared publication
Latest Publications
- 7 February 2006
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 77B (2) , 315-322
Composite coating of bonelike apatite particles and collagen fibers on poly L‐lactic acid formed through an accelerated biomimetic coprecipitation process
Collagen and apatite were coprecipitated as a composite coating on poly L‐lactic acid (PLLA) in an accelerated biomimetic process. The incubation solution contained collagen (1 g/L) and simulated body fluid with 5 times inorganic ionic concentrations as human blood plasma. The coating formed on PLLA films and scaffolds after a 24‐h incubation was characterized by using energy‐dispersive X‐ray spectroscopy, X‐ray diffraction, Fourier transform infrared spectroscopy, and scanning electron microscopy (SEM). It was shown that the coating contained carbonated bonelike apatite and collagen, which was similar in composition to natural bone. SEM showed a complex composite coating of submicron bonelike apatite particulates combined with collagen fibrils. It is expected that such biocomposite coating may better facilitate cell interaction and osteoconductivity. This work provided an efficient process to obtain bonelike apatite/collagen composite coating, which is potentially useful in bone tissue engineering. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2006
- 7 February 2006
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 77B (2) , 315-322
Composite coating of bonelike apatite particles and collagen fibers on poly L‐lactic acid formed through an accelerated biomimetic coprecipitation process
Collagen and apatite were coprecipitated as a composite coating on poly L‐lactic acid (PLLA) in an accelerated biomimetic process. The incubation solution contained collagen (1 g/L) and simulated body fluid with 5 times inorganic ionic concentrations as human blood plasma. The coating formed on PLLA films and scaffolds after a 24‐h incubation was characterized by using energy‐dispersive X‐ray spectroscopy, X‐ray diffraction, Fourier transform infrared spectroscopy, and scanning electron microscopy (SEM). It was shown that the coating contained carbonated bonelike apatite and collagen, which was similar in composition to natural bone. SEM showed a complex composite coating of submicron bonelike apatite particulates combined with collagen fibrils. It is expected that such biocomposite coating may better facilitate cell interaction and osteoconductivity. This work provided an efficient process to obtain bonelike apatite/collagen composite coating, which is potentially useful in bone tissue engineering. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2006
- 25 January 2005
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 73B (1) , 68-76
Formation of apatite on poly(α‐hydroxy acid) in an accelerated biomimetic process
Bonelike apatite coating was formed on poly(L‐lactic acid) films and poly(glycolic acid) scaffolds within 24 h through an accelerated biomimetic process. The ion concentrations in the simulated body fluid (SBF) were nearly 5 times of those in the human blood plasma. The apatite formed was characterized by using scanning electron microscopy (SEM), energy dispersive X‐ray spectroscopy (EDX), X‐ray diffraction (XRD), and Fourier transform infrared spectroscopy (FTIR). The apatite formed in 5SBFs was similar in morphology and composition to that formed in the classical biomimetic process using SBF or 1.5SBF and similar to that of natural bone. This indicated that the biomimetic apatite‐coating process could be accelerated by using concentrated simulated body fluid at 37°C. Besides saving time, the accelerated biomimetic process is particularly significant to biodegradable polymers. Some polymers that degrade too fast to be coated with apatite by a classical biomimetic process (e.g., PGA) could be coated with bonelike apatite in an accelerated biomimetic process. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 73B: 68–76, 2005
- 25 January 2005
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 73B (1) , 68-76
Formation of apatite on poly(α‐hydroxy acid) in an accelerated biomimetic process
Bonelike apatite coating was formed on poly(L‐lactic acid) films and poly(glycolic acid) scaffolds within 24 h through an accelerated biomimetic process. The ion concentrations in the simulated body fluid (SBF) were nearly 5 times of those in the human blood plasma. The apatite formed was characterized by using scanning electron microscopy (SEM), energy dispersive X‐ray spectroscopy (EDX), X‐ray diffraction (XRD), and Fourier transform infrared spectroscopy (FTIR). The apatite formed in 5SBFs was similar in morphology and composition to that formed in the classical biomimetic process using SBF or 1.5SBF and similar to that of natural bone. This indicated that the biomimetic apatite‐coating process could be accelerated by using concentrated simulated body fluid at 37°C. Besides saving time, the accelerated biomimetic process is particularly significant to biodegradable polymers. Some polymers that degrade too fast to be coated with apatite by a classical biomimetic process (e.g., PGA) could be coated with bonelike apatite in an accelerated biomimetic process. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 73B: 68–76, 2005
- 1 January 2005
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 19 (3) , 253-266
Hydraulic Permeability of Polyglycolic Acid Scaffolds as a Function of Biomaterial Degradation
Using a simple experimental setup, the hydraulic permeability of fibrous nonwoven polyglycolic acid (PGA) scaffolds is studied after different degradation durations in PBS. The hydraulic permeability of the scaffolds increased with the degradation time. After being incubated for about 4 weeks, the permeability of the scaffold begins to drop. It is noted that the PGA scaffold apparently begins to contract and cannot maintain its original shape after 4 weeks of degradation. These results underpin the understanding of the biotransport processes in the scaffolds during tissue engineering experiments.
- 1 January 2005
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 19 (3) , 253-266
Hydraulic Permeability of Polyglycolic Acid Scaffolds as a Function of Biomaterial Degradation
Using a simple experimental setup, the hydraulic permeability of fibrous nonwoven polyglycolic acid (PGA) scaffolds is studied after different degradation durations in PBS. The hydraulic permeability of the scaffolds increased with the degradation time. After being incubated for about 4 weeks, the permeability of the scaffold begins to drop. It is noted that the PGA scaffold apparently begins to contract and cannot maintain its original shape after 4 weeks of degradation. These results underpin the understanding of the biotransport processes in the scaffolds during tissue engineering experiments.
- 1 January 2003
- Published by Springer Nature
- p. 111-134
Biomechanics of Body Support Surfaces: Issues of Decubitus Ulcer
- 1 January 2003
- Published by Springer Nature
- p. 111-134
Biomechanics of Body Support Surfaces: Issues of Decubitus Ulcer
- 14 June 2001
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 57 (1) , 140-150
Formation of bone-like apatite on poly(L-lactic acid) fibers by a biomimetic process
Bone-like apatite coating on poly(L-lactic acid) (PLLA) fibers was formed by immersing the fibers in a modified simulated body fluid (SBF) at 37°C and pH 7.3 after hydrolysis of the fibers in water. The ion concentrations in SBF were nearly 1.5 times of those in the human blood plasma. The apatite was characterized by scanning electron microscopy (SEM) with energy dispersive X-ray spectroscopy (EDX), X-ray photoelectron spectroscopy (XPS), thin-film X-ray diffraction, and Fourier transform infrared spectroscopy. After 15 days of incubation in SBF, an apatite layer with about 5–6 μm thickness was formed on the surface of the fibers. This apatite had a Ca/P ratio similar to that of natural bone. The mass of apatite coated PLLA fibers increased with extending the incubation time. After 20 days incubation, the fibers increased their mass by 25.8 ± 2.1%. The apatite coating had no significant effect on the tensile properties of PLLA fibers. In this article, the bone-like apatite coating on three-dimensional PLLA braids was also studied. The motivation for this apatite coating was that it might demonstrate enhanced osteoconductivity in the future studies when they serve as biodegradable scaffolds in tissue engineering. © 2001 John Wiley & Sons, Inc. J Biomed Mater Res 57: 140–150, 2001
- 14 June 2001
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 57 (1) , 140-150
Formation of bone-like apatite on poly(L-lactic acid) fibers by a biomimetic process
Bone-like apatite coating on poly(L-lactic acid) (PLLA) fibers was formed by immersing the fibers in a modified simulated body fluid (SBF) at 37°C and pH 7.3 after hydrolysis of the fibers in water. The ion concentrations in SBF were nearly 1.5 times of those in the human blood plasma. The apatite was characterized by scanning electron microscopy (SEM) with energy dispersive X-ray spectroscopy (EDX), X-ray photoelectron spectroscopy (XPS), thin-film X-ray diffraction, and Fourier transform infrared spectroscopy. After 15 days of incubation in SBF, an apatite layer with about 5–6 μm thickness was formed on the surface of the fibers. This apatite had a Ca/P ratio similar to that of natural bone. The mass of apatite coated PLLA fibers increased with extending the incubation time. After 20 days incubation, the fibers increased their mass by 25.8 ± 2.1%. The apatite coating had no significant effect on the tensile properties of PLLA fibers. In this article, the bone-like apatite coating on three-dimensional PLLA braids was also studied. The motivation for this apatite coating was that it might demonstrate enhanced osteoconductivity in the future studies when they serve as biodegradable scaffolds in tissue engineering. © 2001 John Wiley & Sons, Inc. J Biomed Mater Res 57: 140–150, 2001
- 1 September 2000
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 38 (5) , 497-502
Assessment of neck tissue fibrosis using an ultrasound palpation system: A feasibility study
Fibrotic change in the soft tissue of the neck is a common side-effect after radiotherapy treatment for cancers of the head and neck region. The development of a quantitative approach for the assessment of neck tissue stiffness using an ultrasound palpation system (UPS) is reported. A testing protocol was established with the participation of eight normal subjects and four patients who had neck fibrosis after previous radiotherapy to the neck. Six reference sites were assessed on each side of the neck in each subject. Site-dependence, inter-observer variability, and intra-observer variability were further evaluated by measurement of sites 1cm anterior, posterior, superior and inferior to two of the reference sites on each side of the neck, and by repeating measurements using a second observer on the same occasion and using the same observer one week afterwards. The mean tissue Young's modulus for normal subjects was 12.8±3.9 kPa, and that of the radiotherapy-treated patients ranged from 46.4 to 108.3 kPa. The modulus shows limited variation among anatomical sub-sites within the neck. For a confidence level of 95%, there was a variation of ±14.2% for site-dependence, ±15.2% for inter-observer, and ±7.2% for intra-observer tests for the group of normal subjects. The variation in the patients was ±13.6% for site-dependence, and ±13.1% for the inter-observer test.
- 1 September 2000
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 38 (5) , 497-502
Assessment of neck tissue fibrosis using an ultrasound palpation system: A feasibility study
Fibrotic change in the soft tissue of the neck is a common side-effect after radiotherapy treatment for cancers of the head and neck region. The development of a quantitative approach for the assessment of neck tissue stiffness using an ultrasound palpation system (UPS) is reported. A testing protocol was established with the participation of eight normal subjects and four patients who had neck fibrosis after previous radiotherapy to the neck. Six reference sites were assessed on each side of the neck in each subject. Site-dependence, inter-observer variability, and intra-observer variability were further evaluated by measurement of sites 1cm anterior, posterior, superior and inferior to two of the reference sites on each side of the neck, and by repeating measurements using a second observer on the same occasion and using the same observer one week afterwards. The mean tissue Young's modulus for normal subjects was 12.8±3.9 kPa, and that of the radiotherapy-treated patients ranged from 46.4 to 108.3 kPa. The modulus shows limited variation among anatomical sub-sites within the neck. For a confidence level of 95%, there was a variation of ±14.2% for site-dependence, ±15.2% for inter-observer, and ±7.2% for intra-observer tests for the group of normal subjects. The variation in the patients was ±13.6% for site-dependence, and ±13.1% for the inter-observer test.
- 1 June 1999
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 121 (3) , 330-339
Extraction of Quasi-Linear Viscoelastic Parameters for Lower Limb Soft Tissues From Manual Indentation Experiment
A manual indentation protocol was established to assess the quasi-linear viscoelastic (QLV) properties of lower limb soft tissues. The QLV parameters were extracted using a curve-fitting procedure on the experimental indentation data. The load-indentation responses were obtained using an ultrasound indentation apparatus with a hand-held pen-sized probe. Limb soft tissues at four sites of eight normal young subjects were tested in three body postures. Four QLV model parameters were extracted from the experimental data. The initial modulus E0 ranged from 0.22 kPa to 58.4 kPa. The nonlinear factor E1 ranged from 21.7 kPa to 547 kPa. The time constant τ ranged from 0.05 s to 8.93 s. The time-dependent material parameter α ranged from 0.029 to 0.277. Large variations of the parameters were noted among subjects, sites, and postures.
- 1 June 1999
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 121 (3) , 330-339
Extraction of Quasi-Linear Viscoelastic Parameters for Lower Limb Soft Tissues From Manual Indentation Experiment
A manual indentation protocol was established to assess the quasi-linear viscoelastic (QLV) properties of lower limb soft tissues. The QLV parameters were extracted using a curve-fitting procedure on the experimental indentation data. The load-indentation responses were obtained using an ultrasound indentation apparatus with a hand-held pen-sized probe. Limb soft tissues at four sites of eight normal young subjects were tested in three body postures. Four QLV model parameters were extracted from the experimental data. The initial modulus E0 ranged from 0.22 kPa to 58.4 kPa. The nonlinear factor E1 ranged from 21.7 kPa to 547 kPa. The time constant τ ranged from 0.05 s to 8.93 s. The time-dependent material parameter α ranged from 0.029 to 0.277. Large variations of the parameters were noted among subjects, sites, and postures.