Mei-Jywan Syu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mei-Jywan Syu has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Tsung-Chieh Chiu
Department of Chemical Engineering, National Cheng Kung University, Tainan 701, Taiwan
2 shared publicationsYong-Sheun Chang
Department of Chemical Engineering, National Cheng Kung University, Tainan 701, Taiwan
2 shared publicationsYou-Ming Nian
2 shared publicationsAn-Hua Wu
1 shared publication- Ching-Hsing Luo
School of Data and Computer Science, Sun Yat-sen University, Guangzhou, China
1 shared publication Chune-You Lai
Department of Chemical Engineering, National Cheng Kung University, Tainan 701, Taiwan
1 shared publication
Latest Publications
- Open Access
A Portable Low-Power Acquisition System with a Urease Bioelectrochemical Sensor for Potentiometric Detection of Urea Concentrations
This paper presents a portable low-power battery-driven bioelectrochemical signal acquisition system for urea detection. The proposed design has several advantages, including high performance, low cost, low-power consumption, and high portability. A LT1789-1 low-supply-voltage instrumentation amplifier (IA) was used to measure and amplify the open-circuit potential (OCP) between the working and reference electrodes. An MSP430 micro-controller was programmed to process and transduce the signals to the custom-developed software by ZigBee RF module in wireless mode and UART in able mode. The immobilized urease sensor was prepared by embedding urease into the polymer (aniline-co-o-phenylenediamine) polymeric matrix and then coating/depositing it onto a MEMS-fabricated Au working electrode. The linear correlation established between the urea concentration and the potentiometric change is in the urea concentrations range of 3.16 × 10−4 to 3.16 × 10−2 M with a sensitivity of 31.12 mV/log [M] and a precision of 0.995 (R2 = 0.995). This portable device not only detects urea concentrations, but can also operate continuously with a 3.7 V rechargeab-le lithium-ion battery (500 mA·h) for at least four days. Accordingly, its use is feasible and even promising for home-care applications.
Open AccessA Portable Low-Power Acquisition System with a Urease Bioelectrochemical Sensor for Potentiometric Detection of Urea Concentrations
This paper presents a portable low-power battery-driven bioelectrochemical signal acquisition system for urea detection. The proposed design has several advantages, including high performance, low cost, low-power consumption, and high portability. A LT1789-1 low-supply-voltage instrumentation amplifier (IA) was used to measure and amplify the open-circuit potential (OCP) between the working and reference electrodes. An MSP430 micro-controller was programmed to process and transduce the signals to the custom-developed software by ZigBee RF module in wireless mode and UART in able mode. The immobilized urease sensor was prepared by embedding urease into the polymer (aniline-co-o-phenylenediamine) polymeric matrix and then coating/depositing it onto a MEMS-fabricated Au working electrode. The linear correlation established between the urea concentration and the potentiometric change is in the urea concentrations range of 3.16 × 10−4 to 3.16 × 10−2 M with a sensitivity of 31.12 mV/log [M] and a precision of 0.995 (R2 = 0.995). This portable device not only detects urea concentrations, but can also operate continuously with a 3.7 V rechargeab-le lithium-ion battery (500 mA·h) for at least four days. Accordingly, its use is feasible and even promising for home-care applications.
- 1 April 2009
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 24 (8) , 2671-2677
Ionic effect investigation of a potentiometric sensor for urea and surface morphology observation of entrapped urease/polypyrrole matrix
- 1 April 2009
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 24 (8) , 2671-2677
Ionic effect investigation of a potentiometric sensor for urea and surface morphology observation of entrapped urease/polypyrrole matrix
- 1 October 2006
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 22 (4) , 550-557
Amperometric detection of bilirubin from a micro-sensing electrode with a synthetic bilirubin imprinted poly(MAA-co-EGDMA) film
- 1 October 2006
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 22 (4) , 550-557
Amperometric detection of bilirubin from a micro-sensing electrode with a synthetic bilirubin imprinted poly(MAA-co-EGDMA) film
- 1 July 2006
- Published by Elsevier in Journal of Chromatography A
- Vol. 1122 (1-2) , 54-62
Ionic effect on the binding of bilirubin to the imprinted poly(methacrylic acid-co-ethylene glycol dimethylacrylate)
- 1 July 2006
- Published by Elsevier in Journal of Chromatography A
- Vol. 1122 (1-2) , 54-62
Ionic effect on the binding of bilirubin to the imprinted poly(methacrylic acid-co-ethylene glycol dimethylacrylate)
- 1 August 2005
- Published by Elsevier in Biomaterials
- Vol. 26 (22) , 4684-4692
Binding specificity of α-bilirubin-imprinted poly(methacrylic acid-co-ethylene glycol dimethylacrylate) toward α-bilirubin
- 1 August 2005
- Published by Elsevier in Biomaterials
- Vol. 26 (22) , 4684-4692
Binding specificity of α-bilirubin-imprinted poly(methacrylic acid-co-ethylene glycol dimethylacrylate) toward α-bilirubin
- 5 April 2005
- Published by Elsevier in Analytica Chimica Acta
- Vol. 539 (1-2) , 107-116
Synthesis and characterization of creatinine imprinted poly(4-vinylpyridine-co-divinylbenzene) as a specific recognition receptor
- 5 April 2005
- Published by Elsevier in Analytica Chimica Acta
- Vol. 539 (1-2) , 107-116
Synthesis and characterization of creatinine imprinted poly(4-vinylpyridine-co-divinylbenzene) as a specific recognition receptor
- 1 December 2003
- Published by Springer Nature in Bioprocess and Biosystems Engineering
- Vol. 26 (2) , 83-92
Film analysis of activated sludge microbial discs by the Taguchi method and grey relational analysis
A biofilm model with substrate inhibition is proposed for the activated sludge growing discs of rotating biological contactor (RBC); this model is different from the steady-state biofilm model based on the Monod assumption. Both deep and shallow types of biofilms are examined and discussed. The biofilm models based on both Monod and substrate inhibition (Haldane) assumptions are compared. In addition, the relationships between substrate utilization rate, biofilm thickness, and liquid phase substrate concentration are discussed. The influence order of the factors that affect the biofilm thickness is studied and discussed by combining the Taguchi method and grey relational analysis. In this work, a Taguchi orthogonal table is used to construct the series that is needed for grey relational analysis to determine the influence priority of the four parameters S B , kX f , K s, and K i .
- 1 December 2003
- Published by Springer Nature in Bioprocess and Biosystems Engineering
- Vol. 26 (2) , 83-92
Film analysis of activated sludge microbial discs by the Taguchi method and grey relational analysis
A biofilm model with substrate inhibition is proposed for the activated sludge growing discs of rotating biological contactor (RBC); this model is different from the steady-state biofilm model based on the Monod assumption. Both deep and shallow types of biofilms are examined and discussed. The biofilm models based on both Monod and substrate inhibition (Haldane) assumptions are compared. In addition, the relationships between substrate utilization rate, biofilm thickness, and liquid phase substrate concentration are discussed. The influence order of the factors that affect the biofilm thickness is studied and discussed by combining the Taguchi method and grey relational analysis. In this work, a Taguchi orthogonal table is used to construct the series that is needed for grey relational analysis to determine the influence priority of the four parameters S B , kX f , K s, and K i .