Longzhen Zheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Longzhen Zheng has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Jian Xia
Department of Chemistry and Chemical Engineering, East China Jiao Tong University, Nanchang, Jiangxi 330013, People's Republic of China
7 shared publicationsLeyan Xiong
Department of Chemistry and Chemical Engineering, East China Jiao Tong University, Nanchang, Jiangxi 330013, People's Republic of China
7 shared publicationsShaoming Yang
5 shared publicationsJingpeng Xu
Department of Chemistry and Chemical Engineering, East China Jiao Tong University, Nanchang, Jiangxi 330013, People's Republic of China
4 shared publicationsQiang Liu
Department of Chemistry and Chemical Engineering, East China Jiao Tong University, Nanchang 330013, China
4 shared publicationsWen Liu
Department of Chemistry and Chemical Engineering, East China Jiao Tong University, Nanchang, Jiangxi 330013, People's Republic of China
4 shared publications
Latest Publications
- Open Access
- 1 January 2014
- Published by The Electrochemical Society in ECS Electrochemistry Letters
- Vol. 3 (12) , B26-B29
A Non-Enzyme Hydrogen Peroxide Biosensor Based on Fe3O4/RGO Nanocomposite Material
A sensitive non-enzyme hydrogen peroxide (H2O2) sensor has been prepared based on Fe3O4/reduced graphene oxide (Fe3O4/RGO) nanocomposite material. The sensitivity of Fe3O4/RGO modified electrode toward the electrochemical reduction of H2O2 is higher than that of Fe3O4 or Fe3O4/GO modified electrodes. A linear range of H2O2 concentration is obtained from 5.0 × 10−7 to 3.0 × 10−3 M with a detection limit of 1.8 × 10−7 M (S/N=3). The Fe3O4/RGO modified electrode also exhibits high selectivity and stability in the detection of H2O2, which suggests that Fe3O4/RGO nanocomposite material provides a promising platform for the non-enzyme electrochemical sensor.
- 1 January 2014
- Published by The Electrochemical Society in ECS Electrochemistry Letters
- Vol. 3 (12) , B26-B29
Open AccessA Non-Enzyme Hydrogen Peroxide Biosensor Based on Fe3O4/RGO Nanocomposite Material
A sensitive non-enzyme hydrogen peroxide (H2O2) sensor has been prepared based on Fe3O4/reduced graphene oxide (Fe3O4/RGO) nanocomposite material. The sensitivity of Fe3O4/RGO modified electrode toward the electrochemical reduction of H2O2 is higher than that of Fe3O4 or Fe3O4/GO modified electrodes. A linear range of H2O2 concentration is obtained from 5.0 × 10−7 to 3.0 × 10−3 M with a detection limit of 1.8 × 10−7 M (S/N=3). The Fe3O4/RGO modified electrode also exhibits high selectivity and stability in the detection of H2O2, which suggests that Fe3O4/RGO nanocomposite material provides a promising platform for the non-enzyme electrochemical sensor.
- 1 March 2013
- Published by Elsevier in Analytica Chimica Acta
- Vol. 768, 69-75
Preparation of cobalt-tetraphenylporphyrin/reduced graphene oxide nanocomposite and its application on hydrogen peroxide biosensor
- 1 March 2013
- Published by Elsevier in Analytica Chimica Acta
- Vol. 768, 69-75
Preparation of cobalt-tetraphenylporphyrin/reduced graphene oxide nanocomposite and its application on hydrogen peroxide biosensor
- 30 November 2011
- Published by Elsevier in Journal of Controlled Release
- Vol. 152, e121-e123
Drug carriers based on cyclodextrin inclusion complexes for the controlled release of hydrophobic drugs
- 30 November 2011
- Published by Elsevier in Journal of Controlled Release
- Vol. 152, e121-e123
Drug carriers based on cyclodextrin inclusion complexes for the controlled release of hydrophobic drugs
- 2 June 2010
- Published by Wiley in Fuel Cells
- Vol. 10 (3) , 384-389
Improving the Performance of Platinum Nanocrystal Catalysts by Square‐wave Potential Electrochemical Pretreatment
- 2 June 2010
- Published by Wiley in Fuel Cells
- Vol. 10 (3) , 384-389
Improving the Performance of Platinum Nanocrystal Catalysts by Square‐wave Potential Electrochemical Pretreatment
- 30 March 2010
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 135 (6) , 1339-1344
Improvement of amperometric glucose biosensor by the immobilization of FcCD inclusive complex and carbon nanotube
A novel glucose biosensor was constructed by using ferrocene-carbonyl-β-cyclodextrin (FcCD) inclusive complex as electron-transfer mediator and carbon nanotubes (CNTs) as electron-transfer promoter. FcCD inclusive complex and glucose oxidase (GOx) were covalently bonded to CNTs by poly-L-lysine (PLL) to fabricate a glucose biosensor. The electrocatalytic oxidation of glucose at the biosensor occurred at low potential below 200 mV, avoiding the interference of the main interfering substances in real samples containing a 5-times higher concentration of L-cysteine, ascorbic acid, and uric acid. The biosensor showed fast response for glucose. A broad linear range of glucose concentration from 1.0 × 10−5 to 2.90 × 10−3 M was obtained and the detection limit was 2.2 × 10−6 M.
- 30 March 2010
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 135 (6) , 1339-1344
Improvement of amperometric glucose biosensor by the immobilization of FcCD inclusive complex and carbon nanotube
A novel glucose biosensor was constructed by using ferrocene-carbonyl-β-cyclodextrin (FcCD) inclusive complex as electron-transfer mediator and carbon nanotubes (CNTs) as electron-transfer promoter. FcCD inclusive complex and glucose oxidase (GOx) were covalently bonded to CNTs by poly-L-lysine (PLL) to fabricate a glucose biosensor. The electrocatalytic oxidation of glucose at the biosensor occurred at low potential below 200 mV, avoiding the interference of the main interfering substances in real samples containing a 5-times higher concentration of L-cysteine, ascorbic acid, and uric acid. The biosensor showed fast response for glucose. A broad linear range of glucose concentration from 1.0 × 10−5 to 2.90 × 10−3 M was obtained and the detection limit was 2.2 × 10−6 M.
- 14 January 2010
- Published by Springer Nature in Environmental Chemistry Letters
- Vol. 9 (2) , 251-257
Photocatalytic degradation of phenol with mesoporous TiO2−xBx
- 14 January 2010
- Published by Springer Nature in Environmental Chemistry Letters
- Vol. 9 (2) , 251-257
Photocatalytic degradation of phenol with mesoporous TiO2−xBx
- 18 February 2008
- Published by Wiley in Chinese Journal of Chemistry
- Vol. 26 (2) , 276-280
Layer‐by‐layer Assembly of Noble Metal Nanoparticles on Glassy Carbon Electrode
- 18 February 2008
- Published by Wiley in Chinese Journal of Chemistry
- Vol. 26 (2) , 276-280
Layer‐by‐layer Assembly of Noble Metal Nanoparticles on Glassy Carbon Electrode