Karen P. Hollingsworth
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Karen P. Hollingsworth has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Kevin W. Bowyer
University of Notre Dame
4 shared publications - Patrick J. Flynn
University of Notre Dame
2 shared publications Amanda Hentz
University of Notre Dame
1 shared publication- Patrick J. Flynn
University of Notre Dame
1 shared publication - Patrick J. Flynn
North Carolina State University
1 shared publication Sarah E. Baker
University of Notre Dame
1 shared publication
Latest Publications
- Open Access
- 19 December 2009
- Published by Springer Nature in Identity in the Information Society
- Vol. 2 (3) , 327-343
Factors that degrade the match distribution in iris biometrics
- 19 December 2009
- Published by Springer Nature in Identity in the Information Society
- Vol. 2 (3) , 327-343
Open AccessFactors that degrade the match distribution in iris biometrics
- 1 January 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
The Importance of Small Pupils: A Study of How Pupil Dilation Affects Iris Biometrics
This work studies the effect of pupil dilation on the accuracy of iris biometrics. We find that when matching enrollment and recognition images of the same person, larger differences in pupil dilation yield higher template dissimilarities, and so a greater chance of a false non-match. Another experimental result is that even when the degree of dilation is similar at enrollment and recognition, comparisons involving highly dilated pupils result in worse recognition performance than comparisons involving constricted pupils. We find that when the matched images have similarly highly dilated pupils, the mean Hamming distance of the match distribution increases and the mean Hamming distance of the non-match distribution decreases, bringing the distributions closer together from both directions. We recommend that a measure of pupil dilation be kept as meta-data for every iris code. Also, the absolute dilation of the two images, and the dilation difference between them, should factor into a confidence measure for an iris match.
- 1 January 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
The Importance of Small Pupils: A Study of How Pupil Dilation Affects Iris Biometrics
This work studies the effect of pupil dilation on the accuracy of iris biometrics. We find that when matching enrollment and recognition images of the same person, larger differences in pupil dilation yield higher template dissimilarities, and so a greater chance of a false non-match. Another experimental result is that even when the degree of dilation is similar at enrollment and recognition, comparisons involving highly dilated pupils result in worse recognition performance than comparisons involving constricted pupils. We find that when the matched images have similarly highly dilated pupils, the mean Hamming distance of the match distribution increases and the mean Hamming distance of the non-match distribution decreases, bringing the distributions closer together from both directions. We recommend that a measure of pupil dilation be kept as meta-data for every iris code. Also, the absolute dilation of the two images, and the dilation difference between them, should factor into a confidence measure for an iris match.
- 1 January 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
All Iris Filters are Not Created Equal
Previous research has assumed that all parts of an iris code are equally valuable. Alternatively, some researchers claim that parts of the iris are more valuable, but they still use the same portions of the iris for all subjects. Our research, presented originally, is the first and only work to show experimentally that some bits in the iris code are less reliable than others, and these patterns of fragile bits vary on a subject by subject basis. This paper extends the work presented, answering questions such as "how does a different filter affect the patterns of fragile bits?" and "what causes outliers in these distributions?" We present a modification to our iris biometric system that masks fragile bits and significantly shifts the match distribution away from the non-match distribution.
- 1 January 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
All Iris Filters are Not Created Equal
Previous research has assumed that all parts of an iris code are equally valuable. Alternatively, some researchers claim that parts of the iris are more valuable, but they still use the same portions of the iris for all subjects. Our research, presented originally, is the first and only work to show experimentally that some bits in the iris code are less reliable than others, and these patterns of fragile bits vary on a subject by subject basis. This paper extends the work presented, answering questions such as "how does a different filter affect the patterns of fragile bits?" and "what causes outliers in these distributions?" We present a modification to our iris biometric system that masks fragile bits and significantly shifts the match distribution away from the non-match distribution.