Eran Bornstein
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Eran Bornstein has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Michael Y. Divon
Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, Lenox Hill Hospital, North Shore–LIJ, New York, New York USA
6 shared publications- Ilan E. Timor-Tritsch
Department of Obstetrics, Gynecology and Reproductive Science Icahn School of Medicine at Mount Sinai New York NY USA
4 shared publications Yoni Barnhard
Department of Obstetrics and Gynecology, Lenox Hill Hospital, New York, NY, USA
4 shared publicationsAlan Donnenfeld
3 shared publicationsAna Monteagudo
3 shared publicationsErez Lenchner
2 shared publications
Latest Publications
- 1 October 2013
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 32 (10) , 1863-1868
First‐Trimester Sonographic Findings Associated With a Dandy‐Walker Malformation and Inferior Vermian Hypoplasia
We report 2 cases in which first‐trimester measurements of the intracranial translucency and the brain stem‐to‐occipital bone diameter were markedly enlarged. This finding was thought to represent an abnormal fourth ventricle‐cisterna magna complex. Subsequently, the diagnoses of a Dandy‐Walker malformation with partial vermian agenesis in 1 case and inferior vermian hypoplasia in the other were established and confirmed by either postmortem autopsy or postnatal magnetic resonance imaging. These cases suggest that evaluation of the fourth ventricle‐cisterna magna complex, by measuring the intracranial translucency or brain stem‐to‐occipital bone diameter may identify some cases with structural malformations of the cerebellum as early as the first trimester.
- 1 October 2013
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 32 (10) , 1863-1868
First‐Trimester Sonographic Findings Associated With a Dandy‐Walker Malformation and Inferior Vermian Hypoplasia
We report 2 cases in which first‐trimester measurements of the intracranial translucency and the brain stem‐to‐occipital bone diameter were markedly enlarged. This finding was thought to represent an abnormal fourth ventricle‐cisterna magna complex. Subsequently, the diagnoses of a Dandy‐Walker malformation with partial vermian agenesis in 1 case and inferior vermian hypoplasia in the other were established and confirmed by either postmortem autopsy or postnatal magnetic resonance imaging. These cases suggest that evaluation of the fourth ventricle‐cisterna magna complex, by measuring the intracranial translucency or brain stem‐to‐occipital bone diameter may identify some cases with structural malformations of the cerebellum as early as the first trimester.
- 1 June 2011
- Published by Springer Nature
- p. 151-158
Vasa Previa
- Open Access
- 24 June 2010
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 36 (1) , 20-25
Basic as well as detailed neurosonograms can be performed by offline analysis of three‐dimensional fetal brain volumes
Objectives: To evaluate the feasibility and the processing time of offline analysis of three‐dimensional (3D) brain volumes to perform a basic, as well as a detailed, targeted, fetal neurosonogram.Methods: 3D fetal brain volumes were obtained in 103 consecutive healthy fetuses that underwent routine anatomical survey at 20–23 postmenstrual weeks. Transabdominal gray‐scale and power Doppler volumes of the fetal brain were acquired by one of three experienced sonographers (an average of seven volumes per fetus). Acquisition was first attempted in the sagittal and coronal planes. When the fetal position did not enable easy and rapid access to these planes, axial acquisition at the level of the biparietal diameter was performed. Offline analysis of each volume was performed by two of the authors in a blinded manner. A systematic technique of ‘volume manipulation’ was used to identify a list of 25 brain dimensions/structures comprising a complete basic evaluation, intracranial biometry and a detailed targeted fetal neurosonogram. The feasibility and reproducibility of obtaining diagnostic‐quality images of the different structures was evaluated, and processing times were recorded, by the two examiners.Results: Diagnostic‐quality visualization was feasible in all of the 25 structures, with an excellent visualization rate (85–100%) reported in 18 structures, a good visualization rate (69–97%) reported in five structures and a low visualization rate (38–54%) reported in two structures, by the two examiners. An average of 4.3 and 5.4 volumes were used to complete the examination by the two examiners, with a mean processing time of 7.2 and 8.8 minutes, respectively. The overall agreement rate for diagnostic visualization of the different brain structures between the two examiners was 89.9%, with a kappa coefficient of 0.5 (P < 0.001).Conclusions: In experienced hands, offline analysis of 3D brain volumes is a reproducible modality that can identify all structures necessary to complete both a basic and a detailed second‐trimester fetal neurosonogram. Copyright © 2010 ISUOG. Published by John Wiley & Sons, Ltd.
- 24 June 2010
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 36 (1) , 20-25
Open AccessBasic as well as detailed neurosonograms can be performed by offline analysis of three‐dimensional fetal brain volumes
Objectives: To evaluate the feasibility and the processing time of offline analysis of three‐dimensional (3D) brain volumes to perform a basic, as well as a detailed, targeted, fetal neurosonogram.Methods: 3D fetal brain volumes were obtained in 103 consecutive healthy fetuses that underwent routine anatomical survey at 20–23 postmenstrual weeks. Transabdominal gray‐scale and power Doppler volumes of the fetal brain were acquired by one of three experienced sonographers (an average of seven volumes per fetus). Acquisition was first attempted in the sagittal and coronal planes. When the fetal position did not enable easy and rapid access to these planes, axial acquisition at the level of the biparietal diameter was performed. Offline analysis of each volume was performed by two of the authors in a blinded manner. A systematic technique of ‘volume manipulation’ was used to identify a list of 25 brain dimensions/structures comprising a complete basic evaluation, intracranial biometry and a detailed targeted fetal neurosonogram. The feasibility and reproducibility of obtaining diagnostic‐quality images of the different structures was evaluated, and processing times were recorded, by the two examiners.Results: Diagnostic‐quality visualization was feasible in all of the 25 structures, with an excellent visualization rate (85–100%) reported in 18 structures, a good visualization rate (69–97%) reported in five structures and a low visualization rate (38–54%) reported in two structures, by the two examiners. An average of 4.3 and 5.4 volumes were used to complete the examination by the two examiners, with a mean processing time of 7.2 and 8.8 minutes, respectively. The overall agreement rate for diagnostic visualization of the different brain structures between the two examiners was 89.9%, with a kappa coefficient of 0.5 (P < 0.001).Conclusions: In experienced hands, offline analysis of 3D brain volumes is a reproducible modality that can identify all structures necessary to complete both a basic and a detailed second‐trimester fetal neurosonogram. Copyright © 2010 ISUOG. Published by John Wiley & Sons, Ltd.
- 1 January 2010
- Published by Walter de Gruyter GmbH in Journal of Perinatal Medicine
- Vol. 38 (2) , 227
Advanced maternal age and prenatal diagnosis
- 1 January 2010
- Published by Walter de Gruyter GmbH in Journal of Perinatal Medicine
- Vol. 38 (2) , 227
Advanced maternal age and prenatal diagnosis
- 18 November 2009
- Published by Taylor & Francis in The Journal of Maternal-Fetal & Neonatal Medicine
- Vol. 23 (8) , 781-784
The association of maternal BMI with fetal echogenic intracardiac foci and echogenic bowel
To evaluate the impact of maternal body mass index (BMI) as well as maternal ethnicity on the detection of either echogenic intra-cardiac focus (EIF) or echogenic bowel (EB).This prospective study identified 74 uncomplicated singleton fetuses in which EIF and/or EB were detected between 18 and 21 weeks of gestation (i.e. study group). Seventy four consecutively scanned fetuses without EIF or EB, at the same gestational age, were selected as controls. The differences in maternal BMI and maternal ethnicity were compared between the two groups using the chi(2) test, Fisher's exact test, and the Student t-test. A multivariable logistic regression model was constructed to control for confounders. Odds ratios (OR) and their 95% confidence interval (CI) were computed.The mean maternal BMI was significantly lower in the study group as compared to controls (22.9 +/- 3.1 vs. 28.0 +/- 7.5 kg/m(2), respectively; p < 0.0001). Patients with fetal EIF and/or EB were significantly more likely to be Asians (20.3% vs. 5.4%, OR = 4.5; 95% CI 1.3-16.9). Using a multivariable analysis, controlling for ethnicity, the association between maternal BMI and fetal EIF or EB remained significant (OR = 0.83; 95% CI 0.76-0.91). However, based on this model Asian ethnicity was not an independent risk factor for the detection of EIF and/or EB (OR = 2.6; 95% CI 0.8-8.9).Our data suggests an inverse relationship between the maternal BMI and the detection of fetal EIF and/or EB. Moreover, it appears that low maternal BMI, and not Asian ethnicity, is an independent risk factor for the detection of these echogenic fetal findings.
- 18 November 2009
- Published by Taylor & Francis in The Journal of Maternal-Fetal & Neonatal Medicine
- Vol. 23 (8) , 781-784
The association of maternal BMI with fetal echogenic intracardiac foci and echogenic bowel
To evaluate the impact of maternal body mass index (BMI) as well as maternal ethnicity on the detection of either echogenic intra-cardiac focus (EIF) or echogenic bowel (EB).This prospective study identified 74 uncomplicated singleton fetuses in which EIF and/or EB were detected between 18 and 21 weeks of gestation (i.e. study group). Seventy four consecutively scanned fetuses without EIF or EB, at the same gestational age, were selected as controls. The differences in maternal BMI and maternal ethnicity were compared between the two groups using the chi(2) test, Fisher's exact test, and the Student t-test. A multivariable logistic regression model was constructed to control for confounders. Odds ratios (OR) and their 95% confidence interval (CI) were computed.The mean maternal BMI was significantly lower in the study group as compared to controls (22.9 +/- 3.1 vs. 28.0 +/- 7.5 kg/m(2), respectively; p < 0.0001). Patients with fetal EIF and/or EB were significantly more likely to be Asians (20.3% vs. 5.4%, OR = 4.5; 95% CI 1.3-16.9). Using a multivariable analysis, controlling for ethnicity, the association between maternal BMI and fetal EIF or EB remained significant (OR = 0.83; 95% CI 0.76-0.91). However, based on this model Asian ethnicity was not an independent risk factor for the detection of EIF and/or EB (OR = 2.6; 95% CI 0.8-8.9).Our data suggests an inverse relationship between the maternal BMI and the detection of fetal EIF and/or EB. Moreover, it appears that low maternal BMI, and not Asian ethnicity, is an independent risk factor for the detection of these echogenic fetal findings.
- Open Access
- 1 May 2009
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 28 (5) , 689-693
Diagnostic and Prognostic Aspects in the Sonographic Evaluation of a Fetus With an Oral Mass
- 1 May 2009
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 28 (5) , 689-693
Open AccessDiagnostic and Prognostic Aspects in the Sonographic Evaluation of a Fetus With an Oral Mass
- 1 January 2009
- Published by Walter de Gruyter GmbH in Journal of Perinatal Medicine
- Vol. 37 (2) , 99-102
Advanced maternal age as a sole indication for genetic amniocentesis; risk-benefit analysis based on a large database reflecting the current common practice
Recent advances in prenatal screening, including first and second trimester genetic screening as well as targeted sonography, have significantly improved the detection of trisomy 21. Therefore, several investigators have questioned the validity of recommending genetic amniocentesis to all women who are 35 years or older at delivery. Thus, we sought to investigate the risks and benefits associated with performing genetic amniocentesis in women whose sole indication for testing was advanced maternal age (AMA). A retrospective review of a Genzyme Genetics amniocentesis database (January 2006-December 2006) was performed. All specimens obtained from women of AMA as the sole indication were eligible for analysis. The amniocentesis-related potential fetal loss was calculated based on the traditional fetal loss rate of 1/200 as well as the recently published loss rate of 1/1600 procedures. Risk-benefit analysis was performed by comparing the number of trisomy 21 fetuses identified within the AMA group to the potential number of amniocentesis-related fetal losses within this group. A total of 87,241 amniocentesis specimens were processed during the study period. AMA was the sole indication for genetic amniocentesis in 43,303 cases which formed the study group. In 399 (0.92%) of these cases, a trisomy 21 was identified. Assuming an amniocentesis related fetal loss rates of 1/200 or 1/1600; 217 or 27 fetal losses would have been expected, respectively. Our analysis suggests that the benefit of genetic amniocentesis for the sole indication of AMA far outweighs the potential amniocentesis-related fetal loss rate, regardless of the actual rate one considers.
- 1 January 2009
- Published by Walter de Gruyter GmbH in Journal of Perinatal Medicine
- Vol. 37 (2) , 99-102
Advanced maternal age as a sole indication for genetic amniocentesis; risk-benefit analysis based on a large database reflecting the current common practice
Recent advances in prenatal screening, including first and second trimester genetic screening as well as targeted sonography, have significantly improved the detection of trisomy 21. Therefore, several investigators have questioned the validity of recommending genetic amniocentesis to all women who are 35 years or older at delivery. Thus, we sought to investigate the risks and benefits associated with performing genetic amniocentesis in women whose sole indication for testing was advanced maternal age (AMA). A retrospective review of a Genzyme Genetics amniocentesis database (January 2006-December 2006) was performed. All specimens obtained from women of AMA as the sole indication were eligible for analysis. The amniocentesis-related potential fetal loss was calculated based on the traditional fetal loss rate of 1/200 as well as the recently published loss rate of 1/1600 procedures. Risk-benefit analysis was performed by comparing the number of trisomy 21 fetuses identified within the AMA group to the potential number of amniocentesis-related fetal losses within this group. A total of 87,241 amniocentesis specimens were processed during the study period. AMA was the sole indication for genetic amniocentesis in 43,303 cases which formed the study group. In 399 (0.92%) of these cases, a trisomy 21 was identified. Assuming an amniocentesis related fetal loss rates of 1/200 or 1/1600; 217 or 27 fetal losses would have been expected, respectively. Our analysis suggests that the benefit of genetic amniocentesis for the sole indication of AMA far outweighs the potential amniocentesis-related fetal loss rate, regardless of the actual rate one considers.
- 31 October 2008
- Published by Elsevier in Ultrasound Clinics
- Vol. 3 (4) , 517-528
3D and 4D Fetal Neuroscan: Sharing the Know-how and Tricks of the Trade
- 31 October 2008
- Published by Elsevier in Ultrasound Clinics
- Vol. 3 (4) , 517-528
3D and 4D Fetal Neuroscan: Sharing the Know-how and Tricks of the Trade
- 1 July 2008
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 27 (7) , 1105-1109
Detection of Twin Reversed Arterial Perfusion Sequence at the Time of First-Trimester Screening
Twin reversed arterial perfusion (TRAP) sequence, also known as acardiac malformation, is a rare complication unique to monozygotic multiple gestations. It occurs in approximately 1 per 35,000 pregnancies and in 0.3% of all monozygotic twin gestations. The malformation is characterized by the lack of a well-defined cardiac structure in one twin (acardiac), which acts as a parasite that is hemodynamically dependent on the normal (pump) twin. The malformation in the acardiac twin is always incompatible with survival regardless of its extent, whereas the prognosis of the pump twin may vary considerably. Common complications that affect the prognosis of the pump twin include complications of prematurity secondary to preterm delivery and polyhydramnios as well as congestive heart failure due to the expended cardiac demand. Without prompt detection, follow-up, and treatment, mortality rates for pump twins have been noted to be as high as 50% to 70%. Early sonographic diagnosis, appropriate follow-up, and intervention via cord occlusion when indicated are the mainstays of prenatal care in cases of TRAP sequence and have been associated with substantial improvements in survival. We report a case that emphasizes the added value of 3-dimensional (3D) and color Doppler techniques for both diagnosis of TRAP sequence and detection of poor prognostic features in the first or early second trimester.
- 1 July 2008
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 27 (7) , 1105-1109
Detection of Twin Reversed Arterial Perfusion Sequence at the Time of First-Trimester Screening
Twin reversed arterial perfusion (TRAP) sequence, also known as acardiac malformation, is a rare complication unique to monozygotic multiple gestations. It occurs in approximately 1 per 35,000 pregnancies and in 0.3% of all monozygotic twin gestations. The malformation is characterized by the lack of a well-defined cardiac structure in one twin (acardiac), which acts as a parasite that is hemodynamically dependent on the normal (pump) twin. The malformation in the acardiac twin is always incompatible with survival regardless of its extent, whereas the prognosis of the pump twin may vary considerably. Common complications that affect the prognosis of the pump twin include complications of prematurity secondary to preterm delivery and polyhydramnios as well as congestive heart failure due to the expended cardiac demand. Without prompt detection, follow-up, and treatment, mortality rates for pump twins have been noted to be as high as 50% to 70%. Early sonographic diagnosis, appropriate follow-up, and intervention via cord occlusion when indicated are the mainstays of prenatal care in cases of TRAP sequence and have been associated with substantial improvements in survival. We report a case that emphasizes the added value of 3-dimensional (3D) and color Doppler techniques for both diagnosis of TRAP sequence and detection of poor prognostic features in the first or early second trimester.
- 1 July 2008
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 27 (7) , 1099-1104
Severe Uropathy and Normal Amniotic Fluid Volume in a Male Fetus
The widespread use of sonography as a screening tool for fetal anomalies has facilitated prenatal detection of several fetal conditions characterized by urinary tract dilatation. These conditions are more common in male fetuses and are generally a result of an anatomic defect causing obstruction along the urinary tract system. Although the prognosis of these conditions largely depends on the specific anomaly, several poor prognostic factors have been described. These factors include detection at an early gestational age, bilateral marked dilatation, a persistently obstructed bladder, oligohydramnios causing pulmonary hypoplasia, and the presence of associated fetal or chromosomal anomalies. We report a case in which a male fetus at 14 weeks' gestation had a diagnosis of rapidly progressing bilateral hydronephrosis, massive bladder dilatation, hydroureter, and a surprisingly normal amniotic fluid volume. Serial sonographic surveillance assisted us in obtaining the correct diagnosis, which was important for adequately consulting the patient regarding the fetal prognosis in the affected index pregnancy as well as the likelihood of recurrence in future gestations.
- 1 July 2008
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 27 (7) , 1099-1104
Severe Uropathy and Normal Amniotic Fluid Volume in a Male Fetus
The widespread use of sonography as a screening tool for fetal anomalies has facilitated prenatal detection of several fetal conditions characterized by urinary tract dilatation. These conditions are more common in male fetuses and are generally a result of an anatomic defect causing obstruction along the urinary tract system. Although the prognosis of these conditions largely depends on the specific anomaly, several poor prognostic factors have been described. These factors include detection at an early gestational age, bilateral marked dilatation, a persistently obstructed bladder, oligohydramnios causing pulmonary hypoplasia, and the presence of associated fetal or chromosomal anomalies. We report a case in which a male fetus at 14 weeks' gestation had a diagnosis of rapidly progressing bilateral hydronephrosis, massive bladder dilatation, hydroureter, and a surprisingly normal amniotic fluid volume. Serial sonographic surveillance assisted us in obtaining the correct diagnosis, which was important for adequately consulting the patient regarding the fetal prognosis in the affected index pregnancy as well as the likelihood of recurrence in future gestations.