Qing Ye
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Qing Ye has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Liming Hong
Key Laboratory of Applied Organic Chemistry, Higher Institutions of Jiangxi Province, Shangrao Normal University, Shangrao 334001, China
4 shared publicationsLinhai Liu
Key Laboratory of Applied Organic Chemistry, Higher Institutions of Jiangxi Province, Shangrao Normal University, Shangrao 334001, China
4 shared publicationsZongbao Chen
Key Laboratory of Applied Organic Chemistry, Higher Institutions of Jiangxi Province, School of Chemstry and Envicronmental Science, Shangrao Normal University, Shangrao, China
3 shared publicationsDagui Zheng
Key Laboratory of Applied Organic Chemistry, Higher Institutions of Jiangxi Province, Shangrao Normal University, Shangrao, P. R. China
1 shared publicationZhongbao Chen
Department of Chemistry, Shangrao Normal University, Shangrao 334001, China
1 shared publication
Latest Publications
- Open Access
- 31 July 2018
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 56 (10) , 955-961
Analysis of Perfluorinated Compounds in Environmental Water Using Decyl-perfluorinated Magnetic Mesoporous Microspheres as Magnetic Solid-Phase Extraction Materials and Microwave-Assisted Derivatization Followed by Gas Chromatography–mass Spectrometry
In this work, a new method was developed for perfluorinated compounds (PFCs) analysis in water samples based on decyl-perfluorinated magnetic mesoporous nanocomposites microspheres-assisted extraction and microwave-assisted derivatization followed by gas chromatography–mass spectrometry analysis. The decyl-perfluorinated magnetic mesoporous nanocomposites have several advantages such as fast separation ability, good dispersibility in water sample and high selective preconcentration of PFCs. Various parameters, including eluting solvent and volume, the amounts of absorbents, extraction time and elution time, the microwave-assisted derivatization conditions were optimized. Validation studies showed that this method has good linearity (r2 > 0.9970), satisfactory precision (RSD < 7.8%) and high recovery (93–107%). The limits of detection were found to be 0.055–0.086 μg/L and the limits of quantification be 0.18–0.28 μg/L, respectively. The results indicated that the proposed method has advantages of convenience, good sensitivity and high efficiency. The method has been applied successfully to analyze perfluorinated organic acids in real water samples.
- 31 July 2018
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 56 (10) , 955-961
Open AccessAnalysis of Perfluorinated Compounds in Environmental Water Using Decyl-perfluorinated Magnetic Mesoporous Microspheres as Magnetic Solid-Phase Extraction Materials and Microwave-Assisted Derivatization Followed by Gas Chromatography–mass Spectrometry
In this work, a new method was developed for perfluorinated compounds (PFCs) analysis in water samples based on decyl-perfluorinated magnetic mesoporous nanocomposites microspheres-assisted extraction and microwave-assisted derivatization followed by gas chromatography–mass spectrometry analysis. The decyl-perfluorinated magnetic mesoporous nanocomposites have several advantages such as fast separation ability, good dispersibility in water sample and high selective preconcentration of PFCs. Various parameters, including eluting solvent and volume, the amounts of absorbents, extraction time and elution time, the microwave-assisted derivatization conditions were optimized. Validation studies showed that this method has good linearity (r2 > 0.9970), satisfactory precision (RSD < 7.8%) and high recovery (93–107%). The limits of detection were found to be 0.055–0.086 μg/L and the limits of quantification be 0.18–0.28 μg/L, respectively. The results indicated that the proposed method has advantages of convenience, good sensitivity and high efficiency. The method has been applied successfully to analyze perfluorinated organic acids in real water samples.
- 29 March 2016
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 8 (16) , 3391-3396
Determination of bisphenols in environmental water samples using polydopamine-coated magnetic Fe3O4 as a magnetic solid-phase extraction material coupled with high-performance liquid chromatography
Fe3O4@polydopamine composites were synthesized and used as a magnetic adsorbent to extract bisphenols from environmental water samples before determination using HPLC.
- 29 March 2016
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 8 (16) , 3391-3396
Determination of bisphenols in environmental water samples using polydopamine-coated magnetic Fe3O4 as a magnetic solid-phase extraction material coupled with high-performance liquid chromatography
Fe3O4@polydopamine composites were synthesized and used as a magnetic adsorbent to extract bisphenols from environmental water samples before determination using HPLC.
- 29 February 2016
- Published by Wiley in Journal of Separation Science
- Vol. 39 (9) , 1684-1690
Analysis of chlorophenols in environmental water using polydopamine‐coated magnetic graphene as an extraction material coupled with high‐performance liquid chromatography
In this work, polydopamine‐coated magnetic graphene nanocomposites were synthesized by a simple solvothermal reaction and self‐polymerization of dopamine, and the as‐made nanocomposites were successfully applied as an effective adsorbent for the preconcentration of the four chlorophenols in environmental water samples before high‐performance liquid chromatography. The polydopamine‐coated magnetic graphene nanocomposites have several advantages such as a high surface area, fast separation ability, super‐hydrophilicity, and high peak intensities for aromatic analytes. Various parameters, including eluting solvent and volume, the amounts of absorbents, extraction time and elution time were optimized. Validation experiments showed that the optimized method had good linearity (r2 > 0.9990), satisfactory precision (RSD < 6.7%) and high recovery (90–105%). The limits of detection were 0.013–0.020 μg/L and the limits of quantification ranged from 0.043 to 0.070 μg/L. The results indicated that the proposed method had advantages of convenience, good sensitivity, and high efficiency. The method has been applied successfully to analyze chlorophenols in real water samples.
- 29 February 2016
- Published by Wiley in Journal of Separation Science
- Vol. 39 (9) , 1684-1690
Analysis of chlorophenols in environmental water using polydopamine‐coated magnetic graphene as an extraction material coupled with high‐performance liquid chromatography
In this work, polydopamine‐coated magnetic graphene nanocomposites were synthesized by a simple solvothermal reaction and self‐polymerization of dopamine, and the as‐made nanocomposites were successfully applied as an effective adsorbent for the preconcentration of the four chlorophenols in environmental water samples before high‐performance liquid chromatography. The polydopamine‐coated magnetic graphene nanocomposites have several advantages such as a high surface area, fast separation ability, super‐hydrophilicity, and high peak intensities for aromatic analytes. Various parameters, including eluting solvent and volume, the amounts of absorbents, extraction time and elution time were optimized. Validation experiments showed that the optimized method had good linearity (r2 > 0.9990), satisfactory precision (RSD < 6.7%) and high recovery (90–105%). The limits of detection were 0.013–0.020 μg/L and the limits of quantification ranged from 0.043 to 0.070 μg/L. The results indicated that the proposed method had advantages of convenience, good sensitivity, and high efficiency. The method has been applied successfully to analyze chlorophenols in real water samples.
- 1 February 2014
- Published by Elsevier in Journal of Chromatography A
- Vol. 1329, 24-29
Analysis of phthalate acid esters in environmental water by magnetic graphene solid phase extraction coupled with gas chromatography–mass spectrometry
- 1 February 2014
- Published by Elsevier in Journal of Chromatography A
- Vol. 1329, 24-29
Analysis of phthalate acid esters in environmental water by magnetic graphene solid phase extraction coupled with gas chromatography–mass spectrometry
- 27 May 2013
- Published by Wiley in Journal of Separation Science
- Vol. 36 (12) , 2028-2034
Rapid analysis of the essential oil components of dried Zanthoxylum bungeanum Maxim by Fe2O3‐magnetic‐microsphere‐assisted microwave distillation and simultaneous headspace single‐drop microextraction followed by GC–MS
In this work, microwave distillation assisted by Fe2O3 magnetic microspheres (FMMS) and headspace single‐drop microextraction were combined, and developed for determination of essential oil compounds in dried Zanthoxylum bungeanum Maxim (ZBM). The FMMS were used as microwave absorption solid medium for dry distillation of dried ZBM. Using the proposed method, isolation, extraction, and concentration of essential oil compounds can be carried out in a single step. The experimental parameters including extraction solvent, solvent volume, microwave power, irradiation time, and the amount of added FMMS, were studied. The optimal analytical conditions were: 2.0 μL decane as the extraction solvent, microwave power of 300 W, irradiation time of 2 min, and the addition of 0.1 g FMMS to ZBM. The method precision was from 4 to 10%. A total of 52 compounds were identified by the proposed method. The conventional steam distillation method was also used for the analysis of essential oil in dried ZBM and only 31 compounds were identified by steam distillation method. It was found that the proposed method is a simple, rapid, reliable, and solvent‐free technique for the determination of volatile compounds in Chinese herbs.
- 27 May 2013
- Published by Wiley in Journal of Separation Science
- Vol. 36 (12) , 2028-2034
Rapid analysis of the essential oil components of dried Zanthoxylum bungeanum Maxim by Fe2O3‐magnetic‐microsphere‐assisted microwave distillation and simultaneous headspace single‐drop microextraction followed by GC–MS
In this work, microwave distillation assisted by Fe2O3 magnetic microspheres (FMMS) and headspace single‐drop microextraction were combined, and developed for determination of essential oil compounds in dried Zanthoxylum bungeanum Maxim (ZBM). The FMMS were used as microwave absorption solid medium for dry distillation of dried ZBM. Using the proposed method, isolation, extraction, and concentration of essential oil compounds can be carried out in a single step. The experimental parameters including extraction solvent, solvent volume, microwave power, irradiation time, and the amount of added FMMS, were studied. The optimal analytical conditions were: 2.0 μL decane as the extraction solvent, microwave power of 300 W, irradiation time of 2 min, and the addition of 0.1 g FMMS to ZBM. The method precision was from 4 to 10%. A total of 52 compounds were identified by the proposed method. The conventional steam distillation method was also used for the analysis of essential oil in dried ZBM and only 31 compounds were identified by steam distillation method. It was found that the proposed method is a simple, rapid, reliable, and solvent‐free technique for the determination of volatile compounds in Chinese herbs.
- 19 May 2011
- Published by Wiley in Journal of Separation Science
- Vol. 34 (13) , 1607-1612
Rapid analysis of aldehydes by simultaneous microextraction and derivatization followed by GC‐MS
Ultrasound-assisted dispersive liquid–liquid microextraction (UDLLME) and simultaneous derivatization followed by GC-MS was developed for the analysis of four aldehydes including acetaldehyde (ACE), propionaldehyde (PRO), butyraldehyde (BUT) and valeraldehyde (VAL) in water samples. In the proposed method, the aldehydes were derivatized with O-2,3,4,5,6-(pentafluorobenzyl)hydroxylamine (PFBHA) and extracted by UDLLME in aqueous solution simultaneously; finally, the derivatives were analyzed by GC-MS. The experimental parameters were investigated and the method validations were studied. The optimal conditions were: aqueous sample of 5 mL, PFBHA of 50 μL, 1.0 mL ethanol (disperser solvent) containing 20 μL chlorobenzene (extraction solvent), ultrasound time of 2 min and centrifuging time of 3 min at 6000 rpm. The proposed method provided satisfactory precision (RSD 1.8–10.2%), wide linear range (0.8–160 μg/L), good linearity (R2 0.9983–0.9993), good relative recovery (85–105%) and low limit of detection (0.16–0.23 μg/L). The proposed method was successfully applied for the analysis of aldehydes in water samples. The experimental results showed that the proposed method was a very simple, rapid, low-cost, sensitive and efficient analytical method for the determination of trace amount of aldehydes in water samples.
- 19 May 2011
- Published by Wiley in Journal of Separation Science
- Vol. 34 (13) , 1607-1612
Rapid analysis of aldehydes by simultaneous microextraction and derivatization followed by GC‐MS
Ultrasound-assisted dispersive liquid–liquid microextraction (UDLLME) and simultaneous derivatization followed by GC-MS was developed for the analysis of four aldehydes including acetaldehyde (ACE), propionaldehyde (PRO), butyraldehyde (BUT) and valeraldehyde (VAL) in water samples. In the proposed method, the aldehydes were derivatized with O-2,3,4,5,6-(pentafluorobenzyl)hydroxylamine (PFBHA) and extracted by UDLLME in aqueous solution simultaneously; finally, the derivatives were analyzed by GC-MS. The experimental parameters were investigated and the method validations were studied. The optimal conditions were: aqueous sample of 5 mL, PFBHA of 50 μL, 1.0 mL ethanol (disperser solvent) containing 20 μL chlorobenzene (extraction solvent), ultrasound time of 2 min and centrifuging time of 3 min at 6000 rpm. The proposed method provided satisfactory precision (RSD 1.8–10.2%), wide linear range (0.8–160 μg/L), good linearity (R2 0.9983–0.9993), good relative recovery (85–105%) and low limit of detection (0.16–0.23 μg/L). The proposed method was successfully applied for the analysis of aldehydes in water samples. The experimental results showed that the proposed method was a very simple, rapid, low-cost, sensitive and efficient analytical method for the determination of trace amount of aldehydes in water samples.
- 1 December 2008
- Published by Elsevier in Journal of Chromatography A
- Vol. 1213 (2) , 239-244
Development of solid-phase microextraction followed by gas chromatography–mass spectrometry for rapid analysis of volatile organic chemicals in mainstream cigarette smoke
- 1 December 2008
- Published by Elsevier in Journal of Chromatography A
- Vol. 1213 (2) , 239-244
Development of solid-phase microextraction followed by gas chromatography–mass spectrometry for rapid analysis of volatile organic chemicals in mainstream cigarette smoke