M. Moscovitch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
M. Moscovitch has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
A. Romanyukha
The US Naval Dosimetry Center, Bethesda, MD 20889, USA
4 shared publicationsF. Hull
The US Naval Dosimetry Center, Bethesda, MD 20889, USA
4 shared publicationsL. Benevides
The US Naval Dosimetry Center, Bethesda, MD 20889, USA
4 shared publicationsM. Duffy
The US Naval Dosimetry Center, Bethesda, MD 20889, USA
4 shared publicationsS. Voss
The US Naval Dosimetry Center, Bethesda, MD 20889, USA
4 shared publicationsB. M. Cullum
1 shared publication
Latest Publications
- 30 May 2011
- Published by Elsevier in Radiation Measurements
- Vol. 46 (12) , 1810-1812
Further studies on the light induced fading associated with the application of OSL to personnel dosimetry
- 30 May 2011
- Published by Elsevier in Radiation Measurements
- Vol. 46 (12) , 1810-1812
Further studies on the light induced fading associated with the application of OSL to personnel dosimetry
- Open Access
- 1 March 2011
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 144 (1-4) , 165-167
Uncertainties associated with the use of optically stimulated luminescence in personal dosimetry
This study investigates several sources of uncertainty associated with the application of optically stimulated luminescence (OSL) to personal dosimetry. A commercial OSL system based on Al2O3:C was used for this study. First, it is demonstrated that the concept of repeated evaluation (readout) of the same dosemeter, often referred to as ‘re-analysis’, can introduce uncertainty in the re-estimated dose. This uncertainty is associated with the fact that the re-analysis process depletes some of the populated traps, resulting in a continuous decrease of the OSL signal with each repeated reading. Furthermore, the rate of depletion may be dose-dependent. Second, it is shown that the previously reported light-induced fading in this system is the result of light leaks through miniature openings in the dosemeter badge.
- 1 March 2011
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 144 (1-4) , 165-167
Open AccessUncertainties associated with the use of optically stimulated luminescence in personal dosimetry
This study investigates several sources of uncertainty associated with the application of optically stimulated luminescence (OSL) to personal dosimetry. A commercial OSL system based on Al2O3:C was used for this study. First, it is demonstrated that the concept of repeated evaluation (readout) of the same dosemeter, often referred to as ‘re-analysis’, can introduce uncertainty in the re-estimated dose. This uncertainty is associated with the fact that the re-analysis process depletes some of the populated traps, resulting in a continuous decrease of the OSL signal with each repeated reading. Furthermore, the rate of depletion may be dose-dependent. Second, it is shown that the previously reported light-induced fading in this system is the result of light leaks through miniature openings in the dosemeter badge.
- 1 March 2011
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 144 (1-4) , 161-164
The applicability of the PTTL dose re-analysis method to the Harshaw LiF:Mg,Cu,P material
The phototransferred thermoluminescence (PTTL) technique is applied to the Harshaw LiF:Mg,Cu,P material. It is demonstrated that using 254-nm UV light, dose levels as low as 0.2 mGy can be re-estimated. The PTTL efficiency was found to be ∼6 % in the dose range of 0.2 mGy–1 Gy, and it appears to be dose-independent. This implies that a simple calibration factor could be applied to the PTTL data for the re-estimation of dose levels. It was demonstrated that with a proper choice of the TL readout parameters, and the UV-light irradiation conditions, dose levels that are relevant to personal or environmental dosimetry can be re-estimated.
- 1 March 2011
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 144 (1-4) , 161-164
The applicability of the PTTL dose re-analysis method to the Harshaw LiF:Mg,Cu,P material
The phototransferred thermoluminescence (PTTL) technique is applied to the Harshaw LiF:Mg,Cu,P material. It is demonstrated that using 254-nm UV light, dose levels as low as 0.2 mGy can be re-estimated. The PTTL efficiency was found to be ∼6 % in the dose range of 0.2 mGy–1 Gy, and it appears to be dose-independent. This implies that a simple calibration factor could be applied to the PTTL data for the re-estimation of dose levels. It was demonstrated that with a proper choice of the TL readout parameters, and the UV-light irradiation conditions, dose levels that are relevant to personal or environmental dosimetry can be re-estimated.
- 31 July 2010
- Published by Elsevier in Radiation Measurements
- Vol. 45 (3-6) , 523-526
Light induced fading in the OSL response of Al2O3:C
- 31 July 2010
- Published by Elsevier in Radiation Measurements
- Vol. 45 (3-6) , 523-526
Light induced fading in the OSL response of Al2O3:C
- 11 July 2006
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 119 (1-4) , 248-254
The application of LiF:Mg,Cu,P to large scale personnel dosimetry: current status and future directions
LiF:Mg,Cu,P is starting to replace LiF:Mg,Ti in a variety of personnel dosimetry applications. LiF:Mg,Cu,P has superior characteristics as compared to LiF:Mg,Ti including, higher sensitivity, improved energy response for photons, lack of supralinearity and insignificant fading. The use of LiF:Mg,Cu,P in large scale dosimetry programs is of particular interest due to the extreme sensitivity of this material to the maximum readout temperature, and the variety of different dosimetry aspects and details that must be considered for a successful implementation in routine dosimetry. Here we discuss and explain the various aspects of large scale LiF:Mg,Cu,P based dosimetry programs including the properties of the TL material, new generation of TLD readers, calibration methodologies, a new generation of dose calculation algorithms based on the use of artificial neural networks and the overall uncertainty of the dose measurement. The United States Navy (USN) will be the first US dosimetry processor who will use this new material for routine applications. Until June 2002, the Navy used two types of thermoluminescent materials for personnel dosimetry, CaF2:Mn and LiF:Mg,Ti. A program to upgrade the system and to implement LiF:Mg,Cu,P, started in the mid 1990s and was recently concluded. In 2002, the new system replaced the LiF:Mg,Ti and is scheduled to start replacing the CaF2:Mn system in 2006. A pilot study to determine the dosimetric performance of the new LiF:Mg,Cu,P based dosimetry system was recently completed, and the results show the new system to be as good or better than the current system in all areas tested. As a result, LiF:Mg,Cu,P is scheduled to become the primary personnel dosimeter for the entire US Navy in 2006.
- 11 July 2006
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 119 (1-4) , 248-254
The application of LiF:Mg,Cu,P to large scale personnel dosimetry: current status and future directions
LiF:Mg,Cu,P is starting to replace LiF:Mg,Ti in a variety of personnel dosimetry applications. LiF:Mg,Cu,P has superior characteristics as compared to LiF:Mg,Ti including, higher sensitivity, improved energy response for photons, lack of supralinearity and insignificant fading. The use of LiF:Mg,Cu,P in large scale dosimetry programs is of particular interest due to the extreme sensitivity of this material to the maximum readout temperature, and the variety of different dosimetry aspects and details that must be considered for a successful implementation in routine dosimetry. Here we discuss and explain the various aspects of large scale LiF:Mg,Cu,P based dosimetry programs including the properties of the TL material, new generation of TLD readers, calibration methodologies, a new generation of dose calculation algorithms based on the use of artificial neural networks and the overall uncertainty of the dose measurement. The United States Navy (USN) will be the first US dosimetry processor who will use this new material for routine applications. Until June 2002, the Navy used two types of thermoluminescent materials for personnel dosimetry, CaF2:Mn and LiF:Mg,Ti. A program to upgrade the system and to implement LiF:Mg,Cu,P, started in the mid 1990s and was recently concluded. In 2002, the new system replaced the LiF:Mg,Ti and is scheduled to start replacing the CaF2:Mn system in 2006. A pilot study to determine the dosimetric performance of the new LiF:Mg,Cu,P based dosimetry system was recently completed, and the results show the new system to be as good or better than the current system in all areas tested. As a result, LiF:Mg,Cu,P is scheduled to become the primary personnel dosimeter for the entire US Navy in 2006.
- 1 August 2002
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 101 (1) , 17-22
Radiation Dosimetry Using Three-dimensional Optical Random Access Memories
The ability to determine particle type and energy plays an important role in the dosimetry of heavy charged particles (HCP) and neutrons. A new approach to radiation dosimetry is presented, which is shown to be capable of particle type and energy discrimination. This method is based on utilising radiation induced changes in the digital information stored on three-dimensional optical random access memories (3D ORAM). 3D ORAM is a small cube (a few mm3) composed of poly(methyl methacrylate) doped with a photochromic dye, and it was originally proposed as a memory device in high speed parallel computers. A Nd:YAG laser system is used to write and read binary information (bits) on the ORAM, which functions as a charged particle detector. Both the read and the write processes use two laser beams that simultaneously strike the material to cause a colour change at their intersection (similar to the darkening of light-sensitive sunglasses when exposed to sunlight). The laser produces colour changes in the ORAM, which then reverts to the original colour ('bit-flips') at sites where energy is deposited from interaction with incident HCP or neutron-recoil protons. The feasibility of this approach was demonstrated both theoretically and experimentally. Calculations based on track structure theory predict that when HCP interact with the ORAM material, the local energy deposition is capable of inducing measurable 'bit-flips'. These predictions were recently confirmed experimentally using two types of ORAM systems, one based on spirobenzopyran and the other on anthracene, as the photochromic dyes.
- 1 August 2002
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 101 (1) , 17-22
Radiation Dosimetry Using Three-dimensional Optical Random Access Memories
The ability to determine particle type and energy plays an important role in the dosimetry of heavy charged particles (HCP) and neutrons. A new approach to radiation dosimetry is presented, which is shown to be capable of particle type and energy discrimination. This method is based on utilising radiation induced changes in the digital information stored on three-dimensional optical random access memories (3D ORAM). 3D ORAM is a small cube (a few mm3) composed of poly(methyl methacrylate) doped with a photochromic dye, and it was originally proposed as a memory device in high speed parallel computers. A Nd:YAG laser system is used to write and read binary information (bits) on the ORAM, which functions as a charged particle detector. Both the read and the write processes use two laser beams that simultaneously strike the material to cause a colour change at their intersection (similar to the darkening of light-sensitive sunglasses when exposed to sunlight). The laser produces colour changes in the ORAM, which then reverts to the original colour ('bit-flips') at sites where energy is deposited from interaction with incident HCP or neutron-recoil protons. The feasibility of this approach was demonstrated both theoretically and experimentally. Calculations based on track structure theory predict that when HCP interact with the ORAM material, the local energy deposition is capable of inducing measurable 'bit-flips'. These predictions were recently confirmed experimentally using two types of ORAM systems, one based on spirobenzopyran and the other on anthracene, as the photochromic dyes.
- 24 September 2001
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 184 (1-2) , 207-218
Radiation dosimetry using three-dimensional optical random access memories
- 24 September 2001
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 184 (1-2) , 207-218
Radiation dosimetry using three-dimensional optical random access memories