John J. Hasenbein
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
John J. Hasenbein has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Erhan Kutanoglu
Operations Research and Industrial Engineering, The University of Texas at Austin, Austin, TX, USA
9 shared publications - Brent Austgen
Operations Research and Industrial Engineering Program, The University of Texas at Austin
5 shared publications - Bara Kim
Department of Mathematics, Korea University, Seoul, Republic of Korea
3 shared publications - David P. Morton
Department of Industrial Engineering and Management Sciences, Northwestern University, Evanston, USA
3 shared publications - Surya Santoso
Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, TX 78712, USA
3 shared publications - Jim G. Dai
School of Operations Research and Information Engineering, Cornell University, Ithaca, New York 14853
2 shared publications
Latest Publications
- 25 September 2025
- Published by Elsevier in Sustainable Energy, Grids and Networks
- Vol. 44
Co-optimization of short- and long-term decisions for the transmission grid’s resilience to flooding
- 25 September 2025
- Published by Elsevier in Sustainable Energy, Grids and Networks
- Vol. 44
Co-optimization of short- and long-term decisions for the transmission grid’s resilience to flooding
- 18 February 2025
- Published by Elsevier in Reliability Engineering & System Safety
- Vol. 259
Value of considering extreme weather resilience in grid capacity expansion planning
- 18 February 2025
- Published by Elsevier in Reliability Engineering & System Safety
- Vol. 259
Value of considering extreme weather resilience in grid capacity expansion planning
- 23 September 2024
- Published by Taylor & Francis in IISE Transactions
- Vol. 57 (8) , 920-937
A two-stage stochastic programming model for electric substation flood mitigation prior to an imminent hurricane
- 23 September 2024
- Published by Taylor & Francis in IISE Transactions
- Vol. 57 (8) , 920-937
A two-stage stochastic programming model for electric substation flood mitigation prior to an imminent hurricane
- Open Access
- 18 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 135117-135134
Three-Stage Optimization Model to Inform Risk-Averse Investment in Power System Resilience to Winter Storms
We propose a three-stage stochastic programming model to inform risk-averse investment in power system resilience to winter storms. The first stage pertains to long-term investment in generator winterization and mobile battery energy storage system (MBESS) resources, the second stage to MBESS deployment prior to an imminent storm, and the third stage to operational response. Serving as a forecast update, an imminent winter storm’s severity is assumed to be known at the time the deployment decisions are made. We incorporate conditional value-at-risk (CVaR) as the risk measure in the objective function to target loss, represented in our model by unserved energy, experienced during high-impact, low-frequency events. We apply the model to a Texas-focused case study based on the ACTIVS 2000-bus synthetic grid with winter storm scenarios generated using historical Winter Storm Uri data. Results demonstrate how the optimal investments are affected by parameters like cost and risk aversion, and also how effectively using CVaR as a risk measure mitigates the outcomes in the tail of the loss distribution over the winter storm impact uncertainty.
- 18 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 135117-135134
Open AccessThree-Stage Optimization Model to Inform Risk-Averse Investment in Power System Resilience to Winter Storms
We propose a three-stage stochastic programming model to inform risk-averse investment in power system resilience to winter storms. The first stage pertains to long-term investment in generator winterization and mobile battery energy storage system (MBESS) resources, the second stage to MBESS deployment prior to an imminent storm, and the third stage to operational response. Serving as a forecast update, an imminent winter storm’s severity is assumed to be known at the time the deployment decisions are made. We incorporate conditional value-at-risk (CVaR) as the risk measure in the objective function to target loss, represented in our model by unserved energy, experienced during high-impact, low-frequency events. We apply the model to a Texas-focused case study based on the ACTIVS 2000-bus synthetic grid with winter storm scenarios generated using historical Winter Storm Uri data. Results demonstrate how the optimal investments are affected by parameters like cost and risk aversion, and also how effectively using CVaR as a risk measure mitigates the outcomes in the tail of the loss distribution over the winter storm impact uncertainty.
- 14 August 2024
- Published by Elsevier in Sustainable Cities and Society
- Vol. 114
Enhancing power grid resilience to winter storms via generator winterization with equity considerations
- 14 August 2024
- Published by Elsevier in Sustainable Cities and Society
- Vol. 114
Enhancing power grid resilience to winter storms via generator winterization with equity considerations
- 5 June 2024
- Published by Institute for Operations Research and the Management Sciences (INFORMS) in INFORMS Journal on Computing
Comparisons of Two-Stage Models for Flood Mitigation of Electrical Substations
We compare stochastic programming and robust optimization decision models for informing the deployment of ad hoc flood mitigation measures to protect electrical substations prior to an imminent and uncertain hurricane. In our models, the first stage captures the deployment of a fixed quantity of flood mitigation resources, and the second stage captures the operation of a potentially degraded power grid with the primary goal of minimizing load shed. To model grid operation, we introduce adaptations of the direct current (DC) and linear programming alternating current (LPAC) power flow approximation models that feature relatively complete recourse by way of an indicator variable. We apply our models to a pair of geographically realistic flooding case studies, one based on Hurricane Harvey and the other on Tropical Storm Imelda. We investigate the effect of the mitigation budget, the choice of power flow model, and the uncertainty perspective on the optimal mitigation strategy. Our results indicate the mitigation budget and uncertainty perspective are impactful, whereas choosing between the DC and LPAC power flow models is of little to no consequence. To validate our models, we assess the performance of the mitigation solutions they prescribe in an alternating current (AC) power flow model. History: Accepted by Pascal Van Hentenryck, Area Editor for Computational Modeling: Methods & Analysis. Funding: This work was supported by the Energy Institute, The University of Texas at Austin. Supplemental Material: The software that supports the findings of this study is available within the paper and its Supplemental Information ( https://pubsonline.informs.org/doi/suppl/10.1287/ijoc.2023.0125 ) as well as from the IJOC GitHub software repository ( https://github.com/INFORMSJoC/2023.0125 ). The complete IJOC Software and Data Repository is available at https://informsjoc.github.io/ .
- 5 June 2024
- Published by Institute for Operations Research and the Management Sciences (INFORMS) in INFORMS Journal on Computing
Comparisons of Two-Stage Models for Flood Mitigation of Electrical Substations
We compare stochastic programming and robust optimization decision models for informing the deployment of ad hoc flood mitigation measures to protect electrical substations prior to an imminent and uncertain hurricane. In our models, the first stage captures the deployment of a fixed quantity of flood mitigation resources, and the second stage captures the operation of a potentially degraded power grid with the primary goal of minimizing load shed. To model grid operation, we introduce adaptations of the direct current (DC) and linear programming alternating current (LPAC) power flow approximation models that feature relatively complete recourse by way of an indicator variable. We apply our models to a pair of geographically realistic flooding case studies, one based on Hurricane Harvey and the other on Tropical Storm Imelda. We investigate the effect of the mitigation budget, the choice of power flow model, and the uncertainty perspective on the optimal mitigation strategy. Our results indicate the mitigation budget and uncertainty perspective are impactful, whereas choosing between the DC and LPAC power flow models is of little to no consequence. To validate our models, we assess the performance of the mitigation solutions they prescribe in an alternating current (AC) power flow model. History: Accepted by Pascal Van Hentenryck, Area Editor for Computational Modeling: Methods & Analysis. Funding: This work was supported by the Energy Institute, The University of Texas at Austin. Supplemental Material: The software that supports the findings of this study is available within the paper and its Supplemental Information ( https://pubsonline.informs.org/doi/suppl/10.1287/ijoc.2023.0125 ) as well as from the IJOC GitHub software repository ( https://github.com/INFORMSJoC/2023.0125 ). The complete IJOC Software and Data Repository is available at https://informsjoc.github.io/ .
- Open Access
Second-order bounds for the M/M/$s$ queue with random arrival rate
Consider an M/M/$s$ queue with the additional feature that the arrival rate is a random variable of which only the mean, variance, and range are known. Using semi-infinite linear programming and duality theory for moment problems, we establish for this setting tight bounds for the expected waiting time. These bounds correspond to an arrival rate that takes only two values. The proofs crucially depend on the fact that the expected waiting time, as function of the arrival rate, has a convex derivative. We apply the novel tight bounds to a rational queueing model, where arriving individuals decide to join or balk based on expected utility and only have partial knowledge about the market size.
Open AccessSecond-order bounds for the M/M/$s$ queue with random arrival rate
Consider an M/M/$s$ queue with the additional feature that the arrival rate is a random variable of which only the mean, variance, and range are known. Using semi-infinite linear programming and duality theory for moment problems, we establish for this setting tight bounds for the expected waiting time. These bounds correspond to an arrival rate that takes only two values. The proofs crucially depend on the fact that the expected waiting time, as function of the arrival rate, has a convex derivative. We apply the novel tight bounds to a rational queueing model, where arriving individuals decide to join or balk based on expected utility and only have partial knowledge about the market size.
- Open Access
- 15 August 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-12
Ranking routes in semiconductor wafer fabs
We develop a method to estimate the quality of processing routes in a wafer fabrication process. Ranking such routes can be useful for identifying the “best” and “worst” routes when making adjustments to recipes. Route categorization is also useful in developing efficient scheduling algorithms. In particular, we propose a method for ranking routes based on count-based metrics such as the number of defects on a wafer. We start with a statistical model to produce a “local” ranking of a tool and then build a “global” ranking via a heuristic procedure. Creating a fully statistical procedure for ranking routes in semiconductor fabrication plants is virtually impossible, given the number of possible routes and the limited data available. Nonetheless, our discussions with working engineers indicate that even approximate rankings are useful for making better operational decisions.
- 15 August 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-12
Open AccessRanking routes in semiconductor wafer fabs
We develop a method to estimate the quality of processing routes in a wafer fabrication process. Ranking such routes can be useful for identifying the “best” and “worst” routes when making adjustments to recipes. Route categorization is also useful in developing efficient scheduling algorithms. In particular, we propose a method for ranking routes based on count-based metrics such as the number of defects on a wafer. We start with a statistical model to produce a “local” ranking of a tool and then build a “global” ranking via a heuristic procedure. Creating a fully statistical procedure for ranking routes in semiconductor fabrication plants is virtually impossible, given the number of possible routes and the limited data available. Nonetheless, our discussions with working engineers indicate that even approximate rankings are useful for making better operational decisions.