Pisol Senawongse
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pisol Senawongse has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Junji Tagami
Cariology and Operative Dentistry, Tokyo Medical and Dental University
5 shared publicationsMasayuki Otsuki
Cariology and Operative Dentistry, Tokyo Medical and Dental University
4 shared publications- Pong Pongprueksa
Department of Operative Dentistry and Endodontics, Faculty of Dentistry, Mahidol University, Bangkok 10400, Thailand
4 shared publications Choltacha Harnirattisai
Department of Operative Dentistry, Faculty of Dentistry, Mahidol University
2 shared publicationsYasushi Shimada
Cariology and Operative Dentistry, Tokyo Medical and Dental University
2 shared publicationsAmara Muangmingsuk
Faculty of Dentistry, Department of Operative Dentistry, Mahidol University, Phayathai, Bangkok 10400, Thailand
1 shared publication
Latest Publications
- Open Access
- 1 January 2011
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 30 (4) , 517-522
Non-destructive assessment of cavity wall adaptation of class V composite restoration using swept-source optical coherence tomography
The purpose of this study was to evaluate gap formations under class V restoration using swept-source optical coherence tomography (SS-OCT). Wedge-shaped cavities were prepared on the buccal surface of 40 extracted premolar teeth at 2 locations; 1) cemento-enamel junction (CEJ) with enamel and cementum margin and 2) root surfaces with cementum margin. The cavity was treated with Clearfil S3 Bond, restored with Clearfil Majesty and polished with abrasive disks. The specimens were kept in water at 37°C for 24 hours and subjected to a thermocycling procedure. Gap formations at the tooth-restoration interface were measured with SS-OCT image and conventional dye leakage under a microscope. There was no effect of the locations of the cavity and the margins of the cavity on the gap formation. Therefore, a significant effect of the observational methods was observed. The gap formation was 0.89±0.48 mm with the SS-OCT, and the gap formation was 0.34±0.41 mm with the dye leakage. The observation with SS-OCT demonstrated a greater degree of gap formation than the observation with dye leakage.
- 1 January 2011
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 30 (4) , 517-522
Open AccessNon-destructive assessment of cavity wall adaptation of class V composite restoration using swept-source optical coherence tomography
The purpose of this study was to evaluate gap formations under class V restoration using swept-source optical coherence tomography (SS-OCT). Wedge-shaped cavities were prepared on the buccal surface of 40 extracted premolar teeth at 2 locations; 1) cemento-enamel junction (CEJ) with enamel and cementum margin and 2) root surfaces with cementum margin. The cavity was treated with Clearfil S3 Bond, restored with Clearfil Majesty and polished with abrasive disks. The specimens were kept in water at 37°C for 24 hours and subjected to a thermocycling procedure. Gap formations at the tooth-restoration interface were measured with SS-OCT image and conventional dye leakage under a microscope. There was no effect of the locations of the cavity and the margins of the cavity on the gap formation. Therefore, a significant effect of the observational methods was observed. The gap formation was 0.89±0.48 mm with the SS-OCT, and the gap formation was 0.34±0.41 mm with the dye leakage. The observation with SS-OCT demonstrated a greater degree of gap formation than the observation with dye leakage.
- 12 May 2010
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 94B (1) , 212-221
Effect of dentine smear layer on the performance of self‐etching adhesive systems: A micro‐tensile bond strength study
This study aimed to evaluate the effect of the smear layer on the micro‐tensile bond strength when two self‐etching adhesives were used with different techniques. Flat dentine surfaces were prepared using either medium grit diamond burs or tungsten carbide burs. Ten specimens from each prepared surfaces were subjected for smear layer evaluation under SEM. Forty specimens from each of the prepared surfaces were further divided into two groups, bonded with either Clearfil SE Bond (SE) or Clearfil S3 Bond (S3) using one of four applications (as manufacturer's instructions, agitation, reapplication, and increased application time), restored with composites and subjected to a micro‐tensile bond strength test. Smear layers created with diamond burs were thicker than those created with tungsten carbide burs. Surfaces prepared with tungsten carbide burs produced a higher bond strength than those prepared with diamond burs and the same type of adhesive resin. SE demonstrated a higher bond strength than S3 for all surfaces. S3 applied with the agitation technique demonstrated a higher bond strength to dentine prepared with tungsten carbide and diamond burs than that applied with other techniques. SE applied with increased time on dentine treated with carbide burs produced the highest bond strength. In conclusion, a thick smear layer decreased bond strength to dentine, and this might be improved by modification of application technique. © 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2010.
- 12 May 2010
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 94B (1) , 212-221
Effect of dentine smear layer on the performance of self‐etching adhesive systems: A micro‐tensile bond strength study
This study aimed to evaluate the effect of the smear layer on the micro‐tensile bond strength when two self‐etching adhesives were used with different techniques. Flat dentine surfaces were prepared using either medium grit diamond burs or tungsten carbide burs. Ten specimens from each prepared surfaces were subjected for smear layer evaluation under SEM. Forty specimens from each of the prepared surfaces were further divided into two groups, bonded with either Clearfil SE Bond (SE) or Clearfil S3 Bond (S3) using one of four applications (as manufacturer's instructions, agitation, reapplication, and increased application time), restored with composites and subjected to a micro‐tensile bond strength test. Smear layers created with diamond burs were thicker than those created with tungsten carbide burs. Surfaces prepared with tungsten carbide burs produced a higher bond strength than those prepared with diamond burs and the same type of adhesive resin. SE demonstrated a higher bond strength than S3 for all surfaces. S3 applied with the agitation technique demonstrated a higher bond strength to dentine prepared with tungsten carbide and diamond burs than that applied with other techniques. SE applied with increased time on dentine treated with carbide burs produced the highest bond strength. In conclusion, a thick smear layer decreased bond strength to dentine, and this might be improved by modification of application technique. © 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2010.
- Open Access
- 1 January 2010
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 29 (3) , 324-329
The effect of the elastic modulus of low-viscosity resins on the microleakage of Class V resin composite restorations under occlusal loading
This study aimed to evaluate the effectiveness of various intermediate layers on the microleakage of Class V restorations under an occlusal load. Wedge-shaped cavities were prepared on the buccal surface of 72 extracted premolars, which were then treated with an adhesive system (One Up Bond F Plus), divided into three groups, and restored with: 1) Estelite Sigma resin composite, 2) a resin composite with Low Flow flowable composite, or 3) a resin composite with High Flow flowable composite. The specimens were subjected to a nano-indentation test to evaluate the elastic modulus of successive layers at the resin-dentine interface and were subjected to a microleakage test under either unloaded or loaded conditions. The elastic moduli were significantly different among substrates (p<0.05), except between the hybrid layer/Low Flow and the hybrid layer/High Flow. The elastic moduli of the Low Flow composite were higher than those of the High Flow composite. Occlusal force increased dentine leakage in the group that was restored without flowable composites.
- 1 January 2010
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 29 (3) , 324-329
Open AccessThe effect of the elastic modulus of low-viscosity resins on the microleakage of Class V resin composite restorations under occlusal loading
This study aimed to evaluate the effectiveness of various intermediate layers on the microleakage of Class V restorations under an occlusal load. Wedge-shaped cavities were prepared on the buccal surface of 72 extracted premolars, which were then treated with an adhesive system (One Up Bond F Plus), divided into three groups, and restored with: 1) Estelite Sigma resin composite, 2) a resin composite with Low Flow flowable composite, or 3) a resin composite with High Flow flowable composite. The specimens were subjected to a nano-indentation test to evaluate the elastic modulus of successive layers at the resin-dentine interface and were subjected to a microleakage test under either unloaded or loaded conditions. The elastic moduli were significantly different among substrates (p<0.05), except between the hybrid layer/Low Flow and the hybrid layer/High Flow. The elastic moduli of the Low Flow composite were higher than those of the High Flow composite. Occlusal force increased dentine leakage in the group that was restored without flowable composites.
- 1 January 2008
- Published by Elsevier in Archives of Oral Biology
- Vol. 53 (1) , 14-19
Morphological characterization and permeability of attrited human dentine
- 1 January 2008
- Published by Elsevier in Archives of Oral Biology
- Vol. 53 (1) , 14-19
Morphological characterization and permeability of attrited human dentine
- 14 September 2007
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 19 (5) , 265-273
Surface Roughness of Nanofill and Nanohybrid Resin Composites after Polishing and Brushing
Purpose: The purpose of this study was to compare the surface roughness of nanofill (Filtek Supreme XT dentin shade and transparent shade, Filtek Z350, and Estelite Sigma), nanohybrid (Tetric EvoCeram, Ceram X, and Premise), and microhybrid resin composites (Filtek Z250, Tetric Ceram, and Clearfil AP‐X) with the materials after polishing or brushing.Materials and Methods: Forty specimens of each resin composite were polymerized for 40 seconds under a matrix strip in cylindrical molds. Each type of polymer was divided into four subgroups: unpolished, polished with abrasive disks (Sof‐Lex), polished with silicone‐impregnated polishing devices (Astropol), and brushed with a toothbrush (Oral B) and toothpaste (Colgate). The surface roughness of each specimen was determined using a contact stylus profilometer and by observation under a scanning electron microscope.Results: No significant differences in surface roughness among the materials were found on unpolished surfaces. For the nanofill resin composites, there were no significant differences in surface roughness between the two polishing methods or among the unpolished surfaces. After brushing, the surfaces of all materials, except those made from Filtek Z350 and Filtek Supreme XT (dentin), had greater roughness than unpolished surfaces and surfaces polished with either abrasive disks or silicone devices. The scanning electron microscope studies revealed that the surface irregularities of the materials corresponded to the results obtained using the surface roughness tester.CLINICAL SIGNIFICANCE: The use of nanofill resin composites made with nanoclusters demonstrated the smoothest surfaces after polishing and brushing.(J Esthet Restor Dent 19:265–275, 2007)
- 14 September 2007
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 19 (5) , 265-273
Surface Roughness of Nanofill and Nanohybrid Resin Composites after Polishing and Brushing
Purpose: The purpose of this study was to compare the surface roughness of nanofill (Filtek Supreme XT dentin shade and transparent shade, Filtek Z350, and Estelite Sigma), nanohybrid (Tetric EvoCeram, Ceram X, and Premise), and microhybrid resin composites (Filtek Z250, Tetric Ceram, and Clearfil AP‐X) with the materials after polishing or brushing.Materials and Methods: Forty specimens of each resin composite were polymerized for 40 seconds under a matrix strip in cylindrical molds. Each type of polymer was divided into four subgroups: unpolished, polished with abrasive disks (Sof‐Lex), polished with silicone‐impregnated polishing devices (Astropol), and brushed with a toothbrush (Oral B) and toothpaste (Colgate). The surface roughness of each specimen was determined using a contact stylus profilometer and by observation under a scanning electron microscope.Results: No significant differences in surface roughness among the materials were found on unpolished surfaces. For the nanofill resin composites, there were no significant differences in surface roughness between the two polishing methods or among the unpolished surfaces. After brushing, the surfaces of all materials, except those made from Filtek Z350 and Filtek Supreme XT (dentin), had greater roughness than unpolished surfaces and surfaces polished with either abrasive disks or silicone devices. The scanning electron microscope studies revealed that the surface irregularities of the materials corresponded to the results obtained using the surface roughness tester.CLINICAL SIGNIFICANCE: The use of nanofill resin composites made with nanoclusters demonstrated the smoothest surfaces after polishing and brushing.(J Esthet Restor Dent 19:265–275, 2007)
- 1 September 2007
- Published by Operative Dentistry in Operative Dentistry
- Vol. 32 (5) , 466-475
Effect of Elastic Cavity Wall and Occlusal Loading on Microleakage and Dentin Bond Strength
Clinical Relevance: The application of filled adhesive or low viscosity resin as an elastic cavity wall had no influence on marginal leakage both at the enamel and dentin margin; however, the application had an influence on increasing the microtensile bond strength to dentin of Class V restorations. Occlusal loading significantly increased the degree of marginal leakage at the dentin margin.
- 1 September 2007
- Published by Operative Dentistry in Operative Dentistry
- Vol. 32 (5) , 466-475
Effect of Elastic Cavity Wall and Occlusal Loading on Microleakage and Dentin Bond Strength
Clinical Relevance: The application of filled adhesive or low viscosity resin as an elastic cavity wall had no influence on marginal leakage both at the enamel and dentin margin; however, the application had an influence on increasing the microtensile bond strength to dentin of Class V restorations. Occlusal loading significantly increased the degree of marginal leakage at the dentin margin.
- 1 June 2006
- Published by Elsevier in Archives of Oral Biology
- Vol. 51 (6) , 457-463
Age-related changes in hardness and modulus of elasticity of dentine
- 1 June 2006
- Published by Elsevier in Archives of Oral Biology
- Vol. 51 (6) , 457-463
Age-related changes in hardness and modulus of elasticity of dentine
- 1 March 2004
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 16 (2) , 107-116
Bond Strengths of Current Adhesive Systems on Intact and Ground Enamel
Purpose: The goal of this study was to compare the microshear bond strengths of current adhesive systems to intact and ground enamel surfaces.Materials and Methods: Three commercially adhesive materials were examined: a two‐step total‐etching self‐priming system (Single Bond®, 3M ESPE, St. Paul, MN, USA), a two‐step self‐etching system (Clearfil SE Bond®, Kuraray Co. Ltd., Osaka, Japan), and an all‐in‐one system (One‐Up Bond® F, Tokuyama Dental, Tokyo, Japan). The labial surfaces of extracted human incisors were used. For intact enamel surfaces, the teeth were polished with pumice. However, for the ground enamel, 0.5 mm deep, flat enamel surfaces at the midlabial aspect were ground with a no. 600 grit silicon carbide paper. Ground and intact enamel surfaces were bonded with one of three bonding systems and a resin composite and were subjected to a microshear bond test.Results: The two self‐etching systems demonstrated lower bond strengths than did the total‐etching system on intact enamel (One‐Up Bond F, 18.59 MPa; Clearfil SE Bond, 35.71 MPa; Single Bond, 47.20 MPa). No significant difference was found between the total‐etching system and the two‐step self‐etching system on ground enamel (One‐Up Bond F, 28.96 MPa; Clearfil SE Bond, 48.51 MPa; Single Bond, 51.07 MPa). Shear bond strengths on ground enamel were significantly higher than those on intact enamel except for the group that was bonded with the total‐etching system.Conclusions: The two‐step adhesives showed significantly higher bond strengths than did the one‐step adhesive. When applying the total‐etching system, no significant differences in bond strength were demonstrated between bonding to intact and to ground enamel.
- 1 March 2004
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 16 (2) , 107-116
Bond Strengths of Current Adhesive Systems on Intact and Ground Enamel
Purpose: The goal of this study was to compare the microshear bond strengths of current adhesive systems to intact and ground enamel surfaces.Materials and Methods: Three commercially adhesive materials were examined: a two‐step total‐etching self‐priming system (Single Bond®, 3M ESPE, St. Paul, MN, USA), a two‐step self‐etching system (Clearfil SE Bond®, Kuraray Co. Ltd., Osaka, Japan), and an all‐in‐one system (One‐Up Bond® F, Tokuyama Dental, Tokyo, Japan). The labial surfaces of extracted human incisors were used. For intact enamel surfaces, the teeth were polished with pumice. However, for the ground enamel, 0.5 mm deep, flat enamel surfaces at the midlabial aspect were ground with a no. 600 grit silicon carbide paper. Ground and intact enamel surfaces were bonded with one of three bonding systems and a resin composite and were subjected to a microshear bond test.Results: The two self‐etching systems demonstrated lower bond strengths than did the total‐etching system on intact enamel (One‐Up Bond F, 18.59 MPa; Clearfil SE Bond, 35.71 MPa; Single Bond, 47.20 MPa). No significant difference was found between the total‐etching system and the two‐step self‐etching system on ground enamel (One‐Up Bond F, 28.96 MPa; Clearfil SE Bond, 48.51 MPa; Single Bond, 51.07 MPa). Shear bond strengths on ground enamel were significantly higher than those on intact enamel except for the group that was bonded with the total‐etching system.Conclusions: The two‐step adhesives showed significantly higher bond strengths than did the one‐step adhesive. When applying the total‐etching system, no significant differences in bond strength were demonstrated between bonding to intact and to ground enamel.
- 2 May 2003
- Published by Elsevier in International Congress Series
- Vol. 1248, 167-170
Effect of enamel prism orientation after irradiation with Er:YAG laser on bond strength
- 2 May 2003
- Published by Elsevier in International Congress Series
- Vol. 1248, 167-170
Effect of enamel prism orientation after irradiation with Er:YAG laser on bond strength