Waldemar Wardencki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Waldemar Wardencki has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Janusz Curyło
4 shared publications- Jacek Namieśnik
Faculty of Chemistry, Gdańsk University of Technology, 80-233 Gdańsk, Poland
2 shared publications Piotr Sowiński
Department of Analytical Chemistry, Chemical Faculty, Gdansk University of Technology, 11/12 Narutowicza Str., 80-952 Gdansk, Poland
2 shared publicationsJaroslaw Orlita
Departament of Analytical Chemistry, Chemical Faculty, Technical University of Gdańsk, 80-952 Gdańsk, 11/12 Narytowicza Str., Poland PL
1 shared publicationMagdalena Michulec
Department of Analytical Chemistry, Chemical Faculty, Gdansk University of Technology, Gdansk
1 shared publication- Magdalena Michulec
Gdansk University of Technology
1 shared publication
Latest Publications
- 1 March 2007
- Published by Elsevier in Journal of Biochemical and Biophysical Methods
- Vol. 70 (2) , 275-288
Trends in solventless sample preparation techniques for environmental analysis
- 1 March 2007
- Published by Elsevier in Journal of Biochemical and Biophysical Methods
- Vol. 70 (2) , 275-288
Trends in solventless sample preparation techniques for environmental analysis
- 1 October 2006
- Published by Taylor & Francis in Analytical Letters
- Vol. 39 (13) , 2629-2642
Application of Single Drop Extraction (SDE) Gas Chromatography Method for the Determination of Carbonyl Compounds in Spirits and Vodkas
The application of single drop extraction (SDE) for isolation and enrichment of carbonyl compounds after derivatization with O‐(2,3,4,5,6‐pentafluorobenzyl)hydroxylamine in spirits and vodkas is discussed. The optimal parameters (extraction volume, drop volume, content of ethyl alcohol, sample volume, temperature and time of extraction) for isolation and preconcentration of C1–C6 aldehydes from alcoholic matrices were established. The developed SDE‐gas chromatography (GC)‐electron capture detection (ECD), an extraction method, allows the determination of low molecular aldehydes at level lower than 1 µg dm−3. The overall analysis time without derivatization is 35 minutes. The procedure was applied for the determination of aldehydes in real alcoholic beverages (vodkas). The simplicity and cost‐effectiveness of the proposed procedure makes it a good alternative to solid phase microextraction (SPME) and other more labor‐intensive methods.
- 1 October 2006
- Published by Taylor & Francis in Analytical Letters
- Vol. 39 (13) , 2629-2642
Application of Single Drop Extraction (SDE) Gas Chromatography Method for the Determination of Carbonyl Compounds in Spirits and Vodkas
The application of single drop extraction (SDE) for isolation and enrichment of carbonyl compounds after derivatization with O‐(2,3,4,5,6‐pentafluorobenzyl)hydroxylamine in spirits and vodkas is discussed. The optimal parameters (extraction volume, drop volume, content of ethyl alcohol, sample volume, temperature and time of extraction) for isolation and preconcentration of C1–C6 aldehydes from alcoholic matrices were established. The developed SDE‐gas chromatography (GC)‐electron capture detection (ECD), an extraction method, allows the determination of low molecular aldehydes at level lower than 1 µg dm−3. The overall analysis time without derivatization is 35 minutes. The procedure was applied for the determination of aldehydes in real alcoholic beverages (vodkas). The simplicity and cost‐effectiveness of the proposed procedure makes it a good alternative to solid phase microextraction (SPME) and other more labor‐intensive methods.
- 1 May 2005
- Published by Elsevier in Analytica Chimica Acta
- Vol. 539 (1-2) , 17-22
Development and evaluation of headspace gas chromatography method for the analysis of carbonyl compounds in spirits and vodkas
- 1 May 2005
- Published by Elsevier in Analytica Chimica Acta
- Vol. 539 (1-2) , 17-22
Development and evaluation of headspace gas chromatography method for the analysis of carbonyl compounds in spirits and vodkas
- 29 July 2004
- Published by Oxford University Press (OUP) in International Journal of Food Science and Technology
- Vol. 39 (7) , 703-717
A review of theoretical and practical aspects of solid-phase microextraction in food analysis
Solid-phase microextraction (SPME) is a modern, solvent-free sample preparation technique, commonly used in trace analysis. This technique has been developed to combine sampling and sample preparation in one step. This paper reviews selected theoretical and practical aspects of the SPME method used for the isolation and preconcentration of impurities, food constituents, additives and flavour compounds in food samples. The main parameters affecting the extraction effectiveness are discussed and exemplified by selected chromatograms. The review is intended for readers who are either new to the field of SPME or its use in food analysis and many examples of its application for different food matrices are listed.
- 29 July 2004
- Published by Oxford University Press (OUP) in International Journal of Food Science and Technology
- Vol. 39 (7) , 703-717
A review of theoretical and practical aspects of solid-phase microextraction in food analysis
Solid-phase microextraction (SPME) is a modern, solvent-free sample preparation technique, commonly used in trace analysis. This technique has been developed to combine sampling and sample preparation in one step. This paper reviews selected theoretical and practical aspects of the SPME method used for the isolation and preconcentration of impurities, food constituents, additives and flavour compounds in food samples. The main parameters affecting the extraction effectiveness are discussed and exemplified by selected chromatograms. The review is intended for readers who are either new to the field of SPME or its use in food analysis and many examples of its application for different food matrices are listed.
- 19 May 2004
- Published by Springer Nature in Chromatographia
- Vol. 60 (1) , S273-S277
Determination of Solvents Residues in Vegetable Oils and Pharmaceuticals by Headspace Analysis and Capillary Gas Chromatography
- 19 May 2004
- Published by Springer Nature in Chromatographia
- Vol. 60 (1) , S273-S277
Determination of Solvents Residues in Vegetable Oils and Pharmaceuticals by Headspace Analysis and Capillary Gas Chromatography
- 1 January 2003
- Published by Elsevier in Journal of Chromatography A
- Vol. 984 (1) , 89-96
Evaluation of headspace solid-phase microextraction for the analysis of volatile carbonyl compounds in spirits and alcoholic beverages
- 1 January 2003
- Published by Elsevier in Journal of Chromatography A
- Vol. 984 (1) , 89-96
Evaluation of headspace solid-phase microextraction for the analysis of volatile carbonyl compounds in spirits and alcoholic beverages
- 24 April 2001
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 369 (7-8) , 661-665
Comparison of extraction techniques for gas chromatographic determination of volatile carbonyl compounds in alcohols
Two extraction procedures, i.e. conventional liquid-liquid extraction (LLE) and liquid solid-phase microextraction (SPME) for extraction of the oximes formed after derivatization of carbonyl compounds with o-(2,3, 4,5,6-pentafluorobenzyl) hydroxylamine (PFBHA) in alcoholic solutions have been compared. The limit of detection for LLE followed by GC-ECD determination of C1–C6 was in the range of 0.23–3.3 μg/L, whereas for liquid SPME 0.005–0.33 μg/L. Both methods elaborated can be applied to the determination of carbonyl compounds present in spirits and alcoholic beverages.
- 24 April 2001
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 369 (7-8) , 661-665
Comparison of extraction techniques for gas chromatographic determination of volatile carbonyl compounds in alcohols
Two extraction procedures, i.e. conventional liquid-liquid extraction (LLE) and liquid solid-phase microextraction (SPME) for extraction of the oximes formed after derivatization of carbonyl compounds with o-(2,3, 4,5,6-pentafluorobenzyl) hydroxylamine (PFBHA) in alcoholic solutions have been compared. The limit of detection for LLE followed by GC-ECD determination of C1–C6 was in the range of 0.23–3.3 μg/L, whereas for liquid SPME 0.005–0.33 μg/L. Both methods elaborated can be applied to the determination of carbonyl compounds present in spirits and alcoholic beverages.