Hans Oechsner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hans Oechsner has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Frank Richter
Chemnitz University of Technology, Institute of Physics, D-09107 Chemnitz, Germany
1 shared publication G. Crolly
Fachbereich Physik and Schwerpunkt für Materialwissenschaften, Universität Kaiserslautern, 67663 Kaiserslautern, Germany
1 shared publication- Rainer Hippler
Institute of Physics, Czech Academy of Sciences 1 , Na Slovance 2, Prague 18221
1 shared publication Y.K. Le
Department of Physics and Institute for Surface and Thin Film Analysis (IFOS), University of Kaiserslautern, Kaiserslautern, Germany
1 shared publication
Latest Publications
- 4 April 2019
- Published by Wiley in Surface and Interface Analysis
- Vol. 51 (6) , 661-666
Momentum dispersion and mass resolution of magnetic sector instruments for surface analysis
The momentum‐dependent dispersion of ion trajectories in a homogeneous magnetic sector field is derived by a trigonometric method. Contrary to the often used transfer matrix technique, the results are not restricted to small momentum differences. Based on the results of the trigonometric evaluation, an expression for the mass resolution of a magnetic sector for an entering ion beam is derived and extensively discussed. An example for high‐resolution magnetic mass spectrometry is presented.
- 4 April 2019
- Published by Wiley in Surface and Interface Analysis
- Vol. 51 (6) , 661-666
Momentum dispersion and mass resolution of magnetic sector instruments for surface analysis
The momentum‐dependent dispersion of ion trajectories in a homogeneous magnetic sector field is derived by a trigonometric method. Contrary to the often used transfer matrix technique, the results are not restricted to small momentum differences. Based on the results of the trigonometric evaluation, an expression for the mass resolution of a magnetic sector for an entering ion beam is derived and extensively discussed. An example for high‐resolution magnetic mass spectrometry is presented.
- 1 March 2004
- Published by Springer Nature in Applied Physics A
- Vol. 78 (5) , 681-685
On the stoichiometry condition for the formation of cubic boron nitride films
- 1 March 2004
- Published by Springer Nature in Applied Physics A
- Vol. 78 (5) , 681-685
On the stoichiometry condition for the formation of cubic boron nitride films
- 15 July 2001
- Published by EDP Sciences in The European Physical Journal Applied Physics
- Vol. 15 (1) , 49-56
Comparative determination of the electron temperature in Ar- and N2-plasmas with electrostatic probes, optical emission spectroscopy OES and energy dispersive mass spectrometry EDMS
The electron temperature T e as the often most essential parameter for applications of low pressures plasma has been derived from comparative in situ measurements with a single and a double electrostatic probe, and with optical emission spectroscopy OES and energy dispersive mass spectrometry EDMS as remote techniques. Electrodeless rf discharges maintained by electron cyclotron wave resonance ECWR in pure Ar and N2 in the pressure regime from 10−2 to 1 Pa have been used as sample plasmas. The evaluation of the OES- and EDMS-signals is described in detail. The pressure dependence of the T e-results derived therefrom is found to compare well with the data from the probe measurements, and with calculations from a charge carrier balance equation. By matching the OES data to the absolute T e-values from the probe measurements, numerical expressions have been obtained by which T e can be quantitatively calculated from the intensity ratios between selected emission lines from the Ar- and the N2-plasma. Furthermore, the EDMS-results are also shown to deliver quantitative information about T e.
- 15 July 2001
- Published by EDP Sciences in The European Physical Journal Applied Physics
- Vol. 15 (1) , 49-56
Comparative determination of the electron temperature in Ar- and N2-plasmas with electrostatic probes, optical emission spectroscopy OES and energy dispersive mass spectrometry EDMS
The electron temperature T e as the often most essential parameter for applications of low pressures plasma has been derived from comparative in situ measurements with a single and a double electrostatic probe, and with optical emission spectroscopy OES and energy dispersive mass spectrometry EDMS as remote techniques. Electrodeless rf discharges maintained by electron cyclotron wave resonance ECWR in pure Ar and N2 in the pressure regime from 10−2 to 1 Pa have been used as sample plasmas. The evaluation of the OES- and EDMS-signals is described in detail. The pressure dependence of the T e-results derived therefrom is found to compare well with the data from the probe measurements, and with calculations from a charge carrier balance equation. By matching the OES data to the absolute T e-values from the probe measurements, numerical expressions have been obtained by which T e can be quantitatively calculated from the intensity ratios between selected emission lines from the Ar- and the N2-plasma. Furthermore, the EDMS-results are also shown to deliver quantitative information about T e.