Joerg Roehrich
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Joerg Roehrich has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Cornelius Hess
Institute of Forensic Medicine, Forensic Toxicology, Johannes Gutenberg University Mainz, Mainz, Germany
2 shared publications J. Becker
2 shared publicationsR. Urban
2 shared publications- Alexandra Philipsen
Department of Psychiatry and Psychotherapy, University Hospital Bonn, Bonn, Germany
1 shared publication - Alicia Poplawski
Institute of Medical Biostatistics, Epidemiology and Informatics (IMBEI), University Medical Center of the Johannes, Gutenberg University, 55122 Mainz, Germany
1 shared publication - Anne Scheunemann
Institute of Legal Medicine, University Medical Center of the Johannes Gutenberg University Mainz, Am Pulverturm 3, 55131 Mainz, Germany
1 shared publication
Latest Publications
- Open Access
- 6 August 2021
- Published by MDPI AG in Metabolites
- Vol. 11 (8) , 521
Enantioselective Quantification of Amphetamine and Metabolites in Serum Samples: Forensic Evaluation and Estimation of Consumption Time
In forensic toxicology, amphetamine intoxications represent one of the most common case groups and present difficult questions for toxicologists. Estimating the time of consumption and the current influence of the stimulant is particularly difficult when only total amphetamine concentrations are considered. Stereoselective analysis and the consideration of metabolites can provide valuable information to facilitate interpretation. An enantioselective liquid chromatography−tandem mass spectrometry (LC-MS/MS) method for detection of amphetamine, norephedrine and 4-hydroxyamphetamine was developed. Validation showed satisfactory selectivity, sensitivity, linearity (0.5–250 ng/mL), precision and accuracy for all enantiomers. The method was applied to a collective of 425 forensic serum samples and 30 serum samples from psychiatric inpatients stating their last time of amphetamine consumption. Norephedrine and 4-hydroxyamphetamine were detected more frequently at higher amphetamine concentrations and at lower amphetamine (R)/(S) concentration ratios, possibly indicating recent consumption. Mean (R)/(S) ratio of amphetamine was 1.14, whereas higher ratios (mean 1.36) were found for amphetamine concentrations below 100 ng/mL. The (R)/(S) ratios of psychiatric inpatients significantly correlated with the reported time intervals to last consumption. The use of amphetamine (R)/(S) ratios and the simultaneous detection of metabolites are promising factors that can facilitate estimation of consumption time and current impairment.
- 6 August 2021
- Published by MDPI AG in Metabolites
- Vol. 11 (8) , 521
Open AccessEnantioselective Quantification of Amphetamine and Metabolites in Serum Samples: Forensic Evaluation and Estimation of Consumption Time
In forensic toxicology, amphetamine intoxications represent one of the most common case groups and present difficult questions for toxicologists. Estimating the time of consumption and the current influence of the stimulant is particularly difficult when only total amphetamine concentrations are considered. Stereoselective analysis and the consideration of metabolites can provide valuable information to facilitate interpretation. An enantioselective liquid chromatography−tandem mass spectrometry (LC-MS/MS) method for detection of amphetamine, norephedrine and 4-hydroxyamphetamine was developed. Validation showed satisfactory selectivity, sensitivity, linearity (0.5–250 ng/mL), precision and accuracy for all enantiomers. The method was applied to a collective of 425 forensic serum samples and 30 serum samples from psychiatric inpatients stating their last time of amphetamine consumption. Norephedrine and 4-hydroxyamphetamine were detected more frequently at higher amphetamine concentrations and at lower amphetamine (R)/(S) concentration ratios, possibly indicating recent consumption. Mean (R)/(S) ratio of amphetamine was 1.14, whereas higher ratios (mean 1.36) were found for amphetamine concentrations below 100 ng/mL. The (R)/(S) ratios of psychiatric inpatients significantly correlated with the reported time intervals to last consumption. The use of amphetamine (R)/(S) ratios and the simultaneous detection of metabolites are promising factors that can facilitate estimation of consumption time and current impairment.
- Open Access
- 13 May 2021
- Published by MDPI AG in Metabolites
- Vol. 11 (5) , 316
Identification of Potential Distinguishing Markers for the Use of Cannabis-Based Medicines or Street Cannabis in Serum Samples
Increasing prescription numbers of cannabis-based medicines raise the question of whether uptake of these medicines can be distinguished from recreational cannabis use. In this pilot study, serum cannabinoid profiles after use of cannabis-based medicines were investigated, in order to identify potential distinguishing markers. Serum samples after use of Sativex®, Dronabinol or medical cannabis were collected and analyzed for 18 different cannabinoids, using a validated liquid chromatography-tandem mass spectrometry (LC-MS/MS) method. Analytes included delta-9-tetrahydrocannabinol, 11-hydroxy-tetrahydrocannabinol, 11-nor-9-carboxy-tetrahydrocannabinol, cannabidiol, cannabinol, cannabigerol, cannabichromene, cannabicyclol, tetrahydrocannabivarin, cannabidivarin, tetrahydocannabinolic acid A, cannabidiolic acid, cannabinolic acid, cannabigerolic acid, cannabichromenic acid, cannabicyclolic acid, tetrahydrocannabivarinic acid and cannabidivarinic acid. Cannabinoid profiles of study samples were compared to profiles of street cannabis user samples via principal component analysis and Kruskal–Wallis test. Potential distinguishing markers for Dronabinol and Sativex® intake were identified, including 11-hydroxy-tetrahydrocannabinol/delta-9-tetrahydrocannabinol ratios ≥1 and increased concentrations of 11-nor-9-carboxy-tetrahydrocannabinol, cannabidiol or cannabichromene. Larger quantities of minor cannabinoids suggested use of cannabis. Use of medical and street cannabis could not be distinguished, except for use of a cannabidiol-rich strain with higher cannabidiol/delta-9-tetrahydrocannabinol and cannabichromene/delta-9-tetrahydrocannabinol ratios. Findings of the study were used to classify forensic serum samples with self-reported use of cannabis-based medicines.
- 13 May 2021
- Published by MDPI AG in Metabolites
- Vol. 11 (5) , 316
Open AccessIdentification of Potential Distinguishing Markers for the Use of Cannabis-Based Medicines or Street Cannabis in Serum Samples
Increasing prescription numbers of cannabis-based medicines raise the question of whether uptake of these medicines can be distinguished from recreational cannabis use. In this pilot study, serum cannabinoid profiles after use of cannabis-based medicines were investigated, in order to identify potential distinguishing markers. Serum samples after use of Sativex®, Dronabinol or medical cannabis were collected and analyzed for 18 different cannabinoids, using a validated liquid chromatography-tandem mass spectrometry (LC-MS/MS) method. Analytes included delta-9-tetrahydrocannabinol, 11-hydroxy-tetrahydrocannabinol, 11-nor-9-carboxy-tetrahydrocannabinol, cannabidiol, cannabinol, cannabigerol, cannabichromene, cannabicyclol, tetrahydrocannabivarin, cannabidivarin, tetrahydocannabinolic acid A, cannabidiolic acid, cannabinolic acid, cannabigerolic acid, cannabichromenic acid, cannabicyclolic acid, tetrahydrocannabivarinic acid and cannabidivarinic acid. Cannabinoid profiles of study samples were compared to profiles of street cannabis user samples via principal component analysis and Kruskal–Wallis test. Potential distinguishing markers for Dronabinol and Sativex® intake were identified, including 11-hydroxy-tetrahydrocannabinol/delta-9-tetrahydrocannabinol ratios ≥1 and increased concentrations of 11-nor-9-carboxy-tetrahydrocannabinol, cannabidiol or cannabichromene. Larger quantities of minor cannabinoids suggested use of cannabis. Use of medical and street cannabis could not be distinguished, except for use of a cannabidiol-rich strain with higher cannabidiol/delta-9-tetrahydrocannabinol and cannabichromene/delta-9-tetrahydrocannabinol ratios. Findings of the study were used to classify forensic serum samples with self-reported use of cannabis-based medicines.
- 1 February 2012
- Published by Elsevier in Forensic Science International
- Vol. 215 (1-3) , 3-7
Detection of the synthetic drug 4-fluoroamphetamine (4-FA) in serum and urine
- 1 February 2012
- Published by Elsevier in Forensic Science International
- Vol. 215 (1-3) , 3-7
Detection of the synthetic drug 4-fluoroamphetamine (4-FA) in serum and urine
- Open Access
- 1 April 2010
- Published by Oxford University Press (OUP) in Journal of Analytical Toxicology
- Vol. 34 (3) , 155-161
Detection of 9-Tetrahydrocannabinol and Amphetamine-Type Stimulants in Oral Fluid Using the Rapid Stat Point-of-Collection Drug-Testing Device
The Rapid Stat assay, a point-of-collection drug-testing device for detection of amphetamines, cannabinoids, cocaine, opiates, methadone, and benzodiazepines in oral fluid, was evaluated for cannabis and amphetamine-type stimulants. The Rapid Stat tests (n = 134) were applied by police officers in routine traffic checks. Oral fluid and blood samples were analyzed using gas chromatography-mass spectrometry (GC-MS) for Δ9-tetrahydrocannabinol, amphetamine, methamphetamine, methylenedioxymethamphetamine, methylenedioxyethylamphetamine, and methylenedioxyamphetamine. The comparison of GC-MS analysis of oral fluid with the Rapid Stat results for cannabis showed a sensitivity of 85%, a specificity of 87%, and a total confirmation rate of 87%.When compared with serum, the sensitivity of the cannabis assay decreased to 71%, the specificity to 60%, and the total confirmation rate to 66%. These findings were possibly caused by an incorrect reading of the THC test results. Comparison of the Rapid Stat amphetamine assay with GC-MS in oral fluid showed a sensitivity of 94%, a specificity of 97%, and a total confirmation rate of 97%. Compared with serum, a sensitivity of 100%, a specificity of 90%, and a total confirmation rate of 92% was found. The amphetamine assay must, therefore, be regarded as satisfactory.
- 1 April 2010
- Published by Oxford University Press (OUP) in Journal of Analytical Toxicology
- Vol. 34 (3) , 155-161
Open AccessDetection of 9-Tetrahydrocannabinol and Amphetamine-Type Stimulants in Oral Fluid Using the Rapid Stat Point-of-Collection Drug-Testing Device
The Rapid Stat assay, a point-of-collection drug-testing device for detection of amphetamines, cannabinoids, cocaine, opiates, methadone, and benzodiazepines in oral fluid, was evaluated for cannabis and amphetamine-type stimulants. The Rapid Stat tests (n = 134) were applied by police officers in routine traffic checks. Oral fluid and blood samples were analyzed using gas chromatography-mass spectrometry (GC-MS) for Δ9-tetrahydrocannabinol, amphetamine, methamphetamine, methylenedioxymethamphetamine, methylenedioxyethylamphetamine, and methylenedioxyamphetamine. The comparison of GC-MS analysis of oral fluid with the Rapid Stat results for cannabis showed a sensitivity of 85%, a specificity of 87%, and a total confirmation rate of 87%.When compared with serum, the sensitivity of the cannabis assay decreased to 71%, the specificity to 60%, and the total confirmation rate to 66%. These findings were possibly caused by an incorrect reading of the THC test results. Comparison of the Rapid Stat amphetamine assay with GC-MS in oral fluid showed a sensitivity of 94%, a specificity of 97%, and a total confirmation rate of 97%. Compared with serum, a sensitivity of 100%, a specificity of 90%, and a total confirmation rate of 92% was found. The amphetamine assay must, therefore, be regarded as satisfactory.