James V. Guarrera
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
James V. Guarrera has a total of 79 co-authors. Here are the top co-authors by number of shared publications:
- Benjamin Samstein
Weill Cornell Medicine, 1300 York Avenue, New York, NY, 10065, USA
7 shared publications Ben Arrington
5 shared publicationsJean C. Emond
4 shared publicationsRobert S. Brown
3 shared publicationsScot D. Henry
Columbia University Medical Center
3 shared publicationsC. Bae
Center for Liver Disease and Transplantation, Department of Surgery, Columbia University Medical Center, New York, New York, USA
2 shared publications
Latest Publications
- 28 May 2014
- Published by Elsevier in Transplantation Proceedings
- Vol. 46 (5) , 1560-1566
The Benefits of Hypothermic Machine Perfusion Are Enhanced With Vasosol and α-Tocopherol in Rodent Donation After Cardiac Death Livers
- 28 May 2014
- Published by Elsevier in Transplantation Proceedings
- Vol. 46 (5) , 1560-1566
The Benefits of Hypothermic Machine Perfusion Are Enhanced With Vasosol and α-Tocopherol in Rodent Donation After Cardiac Death Livers
- Open Access
- 4 December 2013
- Published by Wolters Kluwer Health in Liver Transplantation
- Vol. 20 (2) , 127-129
Looking Into the Crystal Ball: The 60-5 Criterion—A Newly Proposed Predictor of Severe Complications After Liver Transplantation
- 4 December 2013
- Published by Wolters Kluwer Health in Liver Transplantation
- Vol. 20 (2) , 127-129
Open AccessLooking Into the Crystal Ball: The 60-5 Criterion—A Newly Proposed Predictor of Severe Complications After Liver Transplantation
- 6 November 2012
- Published by Springer Nature
- p. 181-193
The Marginal Liver Donor and Organ Preservation Strategies
- 6 November 2012
- Published by Springer Nature
- p. 181-193
The Marginal Liver Donor and Organ Preservation Strategies
- 25 September 2012
- Published by Springer Nature
- p. 289-298
Impact of Brain Death on Abdominal Organs and Allograft Preservation Strategies
- 25 September 2012
- Published by Springer Nature
- p. 289-298
Impact of Brain Death on Abdominal Organs and Allograft Preservation Strategies
- Open Access
- 1 September 2012
- Published by Elsevier in American Journal of Transplantation
- Vol. 12 (9) , 2477-2486
Hypothermic Machine Preservation Reduces Molecular Markers of Ischemia/Reperfusion Injury in Human Liver Transplantation
- 1 September 2012
- Published by Elsevier in American Journal of Transplantation
- Vol. 12 (9) , 2477-2486
Open AccessHypothermic Machine Preservation Reduces Molecular Markers of Ischemia/Reperfusion Injury in Human Liver Transplantation
- Open Access
- 5 July 2012
- Published by Wolters Kluwer Health in Liver Transplantation
- Vol. 18 (Supplement) , S31-S33
Assist devices: Machine preservation of extended criteria donors
Key Points: 1. Hypothermic machine perfusion (HMP) is in its infancy in clinical liver transplantation. Potential benefits include diminished preservation injury (PI) and improved graft function. 2. We have employed HMP in 21 extended criteria donor (ECD livers) at our center with excellent clinical outcomes. 3. Our experience with liver HMP is the only reported clinical experience worldwide representing a total of 41 successful liver transplant cases showing improved outcomes and diminished markers of ischemia/reperfusion injury. 4. Further multicenter and large scale trials are now warranted to further explore the benefits and applicability of liver HMP into the clinical mainstream. Liver Transpl, 2012. © 2012 AASLD.
- 5 July 2012
- Published by Wolters Kluwer Health in Liver Transplantation
- Vol. 18 (Supplement) , S31-S33
Open AccessAssist devices: Machine preservation of extended criteria donors
Key Points: 1. Hypothermic machine perfusion (HMP) is in its infancy in clinical liver transplantation. Potential benefits include diminished preservation injury (PI) and improved graft function. 2. We have employed HMP in 21 extended criteria donor (ECD livers) at our center with excellent clinical outcomes. 3. Our experience with liver HMP is the only reported clinical experience worldwide representing a total of 41 successful liver transplant cases showing improved outcomes and diminished markers of ischemia/reperfusion injury. 4. Further multicenter and large scale trials are now warranted to further explore the benefits and applicability of liver HMP into the clinical mainstream. Liver Transpl, 2012. © 2012 AASLD.
- 29 January 2012
- Published by Wiley in Transplant Infectious Disease
- Vol. 14 (3) , 311-315
The deceased organ donor with an “open abdomen”: proceed with caution
In solid organ transplantation, the disparity between donor supply and patients awaiting transplant continues to increase. The organ shortage has led to relaxation of historic contraindications to organ donation. A large percentage of deceased organ donors have been subjected to traumatic injuries, which can often result in intervention that leads to abdominal packing and intensive care unit resuscitation. The donor with this “open abdomen” (OA) presents a situation in which the risk of organ utilization is difficult to quantify. There exists a concern for the potential of a higher risk for both bacterial and fungal infections, including multidrug‐resistant (MDR) pathogens because of the prevalence of antibiotic use and critical illness in this population. No recommendations have been established for utilization of organs from these OA donors, because data are limited. Herein, we report a case of a 21‐year‐old donor who had sustained a gunshot wound to his abdomen, resulting in a damage‐control laparotomy and abdominal packing. The donor subsequently suffered brain death, and the family consented to organ donation. A multiorgan procurement was performed with respective transplantation of the procured organs (heart, liver, and both kidneys) into 4 separate recipients. Peritoneal swab cultures performed at the time of organ recovery grew out MDR Pseudomonas aeruginosa on the day after procurement, subsequently followed by positive blood and sputum cultures as well. All 4 transplant recipients subsequently developed infections with MDR P. aeruginosa, which appeared to be donor‐derived with similar resistance patterns. Appropriate antibiotic coverage was initiated in all of the patients. Although 2 of the recipients died, mortality did not appear to be clearly associated with the donor‐derived infections. This case illustrates the potential infectious risk associated with organs from donors with an OA, and suggests that aggressive surveillance for occult infections should be pursued.
- 29 January 2012
- Published by Wiley in Transplant Infectious Disease
- Vol. 14 (3) , 311-315
The deceased organ donor with an “open abdomen”: proceed with caution
In solid organ transplantation, the disparity between donor supply and patients awaiting transplant continues to increase. The organ shortage has led to relaxation of historic contraindications to organ donation. A large percentage of deceased organ donors have been subjected to traumatic injuries, which can often result in intervention that leads to abdominal packing and intensive care unit resuscitation. The donor with this “open abdomen” (OA) presents a situation in which the risk of organ utilization is difficult to quantify. There exists a concern for the potential of a higher risk for both bacterial and fungal infections, including multidrug‐resistant (MDR) pathogens because of the prevalence of antibiotic use and critical illness in this population. No recommendations have been established for utilization of organs from these OA donors, because data are limited. Herein, we report a case of a 21‐year‐old donor who had sustained a gunshot wound to his abdomen, resulting in a damage‐control laparotomy and abdominal packing. The donor subsequently suffered brain death, and the family consented to organ donation. A multiorgan procurement was performed with respective transplantation of the procured organs (heart, liver, and both kidneys) into 4 separate recipients. Peritoneal swab cultures performed at the time of organ recovery grew out MDR Pseudomonas aeruginosa on the day after procurement, subsequently followed by positive blood and sputum cultures as well. All 4 transplant recipients subsequently developed infections with MDR P. aeruginosa, which appeared to be donor‐derived with similar resistance patterns. Appropriate antibiotic coverage was initiated in all of the patients. Although 2 of the recipients died, mortality did not appear to be clearly associated with the donor‐derived infections. This case illustrates the potential infectious risk associated with organs from donors with an OA, and suggests that aggressive surveillance for occult infections should be pursued.
- 1 May 2011
- Published by Elsevier in Journal of Surgical Research
- Vol. 167 (2) , e365-e373
Hypothermic Machine Preservation Attenuates Ischemia/Reperfusion Markers After Liver Transplantation: Preliminary Results
- 1 May 2011
- Published by Elsevier in Journal of Surgical Research
- Vol. 167 (2) , e365-e373
Hypothermic Machine Preservation Attenuates Ischemia/Reperfusion Markers After Liver Transplantation: Preliminary Results
- 26 March 2011
- Vol. 16 (1) , 80-2
A novel ex-vivo porcine renal xenotransplantation model using a pulsatile machine preservation system.
Animal models to investigate pathophysiology and xenotransplantation require complex techniques and significant animal utilization. The aim of the study was to develop a reliable ex-vivo technique to test xenotransplant interventions. Miniature Swine being utilized for a nonsurvival study acted as donor animals. Kidneys were flushed and rapidly explanted and chilled to 4°C. Kidneys were assigned to be the control (CK) (n=3) and the mate were used as a Xenograft Kidneys (XK) (n=3). Kidneys were perfused on separate Waters RM 3 perfusion devices. Perfusion temperature was 35-37°C and pressure was 100-110/60-70 mmHg at 60 pulses per minute. CKs were reperfused with autologous blood collected at the time of organ procurement. XKs were reperfused using freshly donated whole human blood. Physical characteristics, urine output were recorded. Core needle biopsies were obtained and examined by a blinded pathologist for evidence of antibody mediated rejection. XK kidneys demonstrated homogenous reperfusion which rapidly became patchy at 5-7 minutes. XK kidneys had become complete black and thrombosed by 60-70 minutes. XK biopsies demonstrated peritubular capillaritis. CK kidneys demonstrated homogenous reperfusion and urine production. H&E stain of CKs only demonstrated nonspecific inflammation. Our ex-vivo porcine xenotransplant model shows early promise as a tool for studying Xeno- associated hyperacute rejection. This technique saves resources and animal utilization.
- 26 March 2011
- Vol. 16 (1) , 80-2
A novel ex-vivo porcine renal xenotransplantation model using a pulsatile machine preservation system.
Animal models to investigate pathophysiology and xenotransplantation require complex techniques and significant animal utilization. The aim of the study was to develop a reliable ex-vivo technique to test xenotransplant interventions. Miniature Swine being utilized for a nonsurvival study acted as donor animals. Kidneys were flushed and rapidly explanted and chilled to 4°C. Kidneys were assigned to be the control (CK) (n=3) and the mate were used as a Xenograft Kidneys (XK) (n=3). Kidneys were perfused on separate Waters RM 3 perfusion devices. Perfusion temperature was 35-37°C and pressure was 100-110/60-70 mmHg at 60 pulses per minute. CKs were reperfused with autologous blood collected at the time of organ procurement. XKs were reperfused using freshly donated whole human blood. Physical characteristics, urine output were recorded. Core needle biopsies were obtained and examined by a blinded pathologist for evidence of antibody mediated rejection. XK kidneys demonstrated homogenous reperfusion which rapidly became patchy at 5-7 minutes. XK kidneys had become complete black and thrombosed by 60-70 minutes. XK biopsies demonstrated peritubular capillaritis. CK kidneys demonstrated homogenous reperfusion and urine production. H&E stain of CKs only demonstrated nonspecific inflammation. Our ex-vivo porcine xenotransplant model shows early promise as a tool for studying Xeno- associated hyperacute rejection. This technique saves resources and animal utilization.
- 1 March 2010
- Published by SAGE Publications in Progress in Transplantation
- Vol. 20 (1) , 14-17
Digital Imaging of Extended Criteria Donor Livers to Facilitate Placement and Utilization
The disparity between organ supply and demand has necessitated more aggressive use of livers from extended criteria donors. Organ sharing between donor service areas and transplant centers in other regions is common. Confidence in the graft quality is greatly improved with a digital image taken in conjunction with the recovery surgeon's report and biopsy data. Three cases in which digital images of various levels of quality allowed the recipient's surgery to proceed, minimized the cold ischemia time, and yielded excellent outcomes are described. Another case in which a picture was not available and the liver was discarded after importation is also presented for comparison.
- 1 March 2010
- Published by SAGE Publications in Progress in Transplantation
- Vol. 20 (1) , 14-17
Digital Imaging of Extended Criteria Donor Livers to Facilitate Placement and Utilization
The disparity between organ supply and demand has necessitated more aggressive use of livers from extended criteria donors. Organ sharing between donor service areas and transplant centers in other regions is common. Confidence in the graft quality is greatly improved with a digital image taken in conjunction with the recovery surgeon's report and biopsy data. Three cases in which digital images of various levels of quality allowed the recipient's surgery to proceed, minimized the cold ischemia time, and yielded excellent outcomes are described. Another case in which a picture was not available and the liver was discarded after importation is also presented for comparison.