T. Sonoda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
T. Sonoda has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
H. Iimura
RIKEN, Nishina Ctr Accelerator Based Sci, 2-1 Hirosawa, Wako, Saitama 3510198, Japan
3 shared publicationsM. Wada
RIKEN, Nishina Ctr Accelerator Based Sci, 2-1 Hirosawa, Wako, Saitama 3510198, Japan
3 shared publicationsC. Sakamoto
Nagoya University
2 shared publicationsD. Pauwels
Instituut voor Kern-en Stralingsfysica K.U.Leuven Celestijnenlaan 200D B-3001 Leuven Belgium
2 shared publicationsH. Ishiyama
High Energy Accelerator Research Organization (KEK)
2 shared publicationsH. Mita
Tsukuba University
2 shared publications
Latest Publications
- 1 January 2018
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 877, 118-123
The laser and optical system for the RIBF-PALIS experiment
- 1 January 2018
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 877, 118-123
The laser and optical system for the RIBF-PALIS experiment
- 22 February 2013
- Published by Springer Nature in Hyperfine Interactions
- Vol. 216 (1-3) , 103-107
Development of a gas cell-based laser ion source for RIKEN PALIS
- 22 February 2013
- Published by Springer Nature in Hyperfine Interactions
- Vol. 216 (1-3) , 103-107
Development of a gas cell-based laser ion source for RIKEN PALIS
- Open Access
Development of a resonant laser ionization gas cell for high-energy, short-lived nuclei
A new laser ion source configuration based on resonant photoionization in a gas cell has been developed at RIBF RIKEN. This system is intended for the future PArasitic RI-beam production by Laser Ion-Source (PALIS) project which will be installed at RIKEN's fragment separator, BigRIPS. A novel implementation of differential pumping, in combination with a sextupole ion beam guide (SPIG), has been developed. A few small scroll pumps create a pressure difference from 1000 hPa - 10^-3 Pa within a geometry drastically miniaturized compared to conventional systems. This system can utilize a large exit hole for fast evacuation times, minimizing the decay loss for short-lived nuclei during extraction from a buffer gas cell, while sufficient gas cell pressure is maintained for stopping high energy RI-beams. In spite of the motion in a dense pressure gradient, the photo-ionized ions inside the gas cell are ejected with an assisting force gas jet and successfully transported to a high-vacuum region via SPIG followed by a quadrupole mass separator. Observed behaviors agree with the results of gas flow and Monte Carlo simulations.
Open AccessDevelopment of a resonant laser ionization gas cell for high-energy, short-lived nuclei
A new laser ion source configuration based on resonant photoionization in a gas cell has been developed at RIBF RIKEN. This system is intended for the future PArasitic RI-beam production by Laser Ion-Source (PALIS) project which will be installed at RIKEN's fragment separator, BigRIPS. A novel implementation of differential pumping, in combination with a sextupole ion beam guide (SPIG), has been developed. A few small scroll pumps create a pressure difference from 1000 hPa - 10^-3 Pa within a geometry drastically miniaturized compared to conventional systems. This system can utilize a large exit hole for fast evacuation times, minimizing the decay loss for short-lived nuclei during extraction from a buffer gas cell, while sufficient gas cell pressure is maintained for stopping high energy RI-beams. In spite of the motion in a dense pressure gradient, the photo-ionized ions inside the gas cell are ejected with an assisting force gas jet and successfully transported to a high-vacuum region via SPIG followed by a quadrupole mass separator. Observed behaviors agree with the results of gas flow and Monte Carlo simulations.
- Open Access
The Laser Ion Source Trap (LIST) coupled to a gas cell catcher
The proof of principle of the Laser Ion Source Trap (LIST) coupled to a gas cell catcher system has been demonstrated at the Leuven Isotope Separator On-Line (LISOL). The experiments were carried out by using the modified gas cell-based laser ion source and the SextuPole Ion Guide (SPIG). Element selective resonance laser ionization of neutral atoms was taking place inside the cold jet expanding out of the gas cell catcher. The laser path was oriented in longitudinal as well as transverse geometries with respect to the atoms flow. The enhancement of beam purity and the feasibility for in-source laser spectroscopy were investigated in off-line and on-line conditions.
Open AccessThe Laser Ion Source Trap (LIST) coupled to a gas cell catcher
The proof of principle of the Laser Ion Source Trap (LIST) coupled to a gas cell catcher system has been demonstrated at the Leuven Isotope Separator On-Line (LISOL). The experiments were carried out by using the modified gas cell-based laser ion source and the SextuPole Ion Guide (SPIG). Element selective resonance laser ionization of neutral atoms was taking place inside the cold jet expanding out of the gas cell catcher. The laser path was oriented in longitudinal as well as transverse geometries with respect to the atoms flow. The enhancement of beam purity and the feasibility for in-source laser spectroscopy were investigated in off-line and on-line conditions.
- 18 June 2009
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 267 (17) , 2918-2926
The Laser Ion Source Trap (LIST) coupled to a gas cell catcher
- 18 June 2009
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 267 (17) , 2918-2926
The Laser Ion Source Trap (LIST) coupled to a gas cell catcher