Qiang Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Qiang Zhao has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Hailin Wang
State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, PR China
4 shared publicationsLihua Hao
Institute of Environmental Science, College of Chemistry and Chemical Engineering, Shanxi University, Taiyuan, Shanxi, 030006, China
4 shared publicationsJie Gao
Research Institute of Environmental Science, College of Chemistry and Chemical Engineering, Shanxi University, Taiyuan 030006, China
3 shared publicationsLin Cheng
Shanxi University
2 shared publicationsQin Lv
Institute of Environmental Science, College of Chemistry and Chemical Engineering, Shanxi University, Taiyuan 030006, PR China
2 shared publicationsXia Geng
Shanxi University
2 shared publications
Latest Publications
- 23 April 2016
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 408 (17) , 4715-4722
An aptamer assay using rolling circle amplification coupled with thrombin catalysis for protein detection
We describe a sensitive aptamer-based sandwich assay for protein detection on microplate by using rolling circle amplification (RCA) coupled with thrombin catalysis. This assay takes advantage of RCA generating long DNA oligonucleotides with repeat thrombin-binding aptamer sequence, specific aptamer affinity binding to achieve multiple thrombin labeling, and enzyme activity of thrombin for signal generation. Protein target is specifically captured by antibody-coated microplate. Then, an oligonucleotide containing an aptamer for protein and a primer sequence is added to form a typical sandwich structure. Following a template encoded with complementary sequence of aptamer for thrombin, RCA reaction extends the primer sequence into a long oligonucleotide. Many thrombin molecules bind with the RCA product. Thrombin catalyzes the conversion of its chromogenic or fluorogenic peptide substrates into detectable products for final quantification of protein targets. We applied this strategy to the detection of a model protein target, platelet-derived growth factor-BB (PDGF-BB). Due to double signal amplifications from RCA and thrombin catalysis, this assay enabled the detection of PDGF-BB as low as 3.1 pM when a fluorogenic peptide substrate was used. This assay provides a new way for signal generation in RCA-involved assay through direct thrombin labeling, circumventing time-consuming preparation of enzyme-conjugate and affinity probes. This method has promise for a variety of analytical applications.
- 23 April 2016
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 408 (17) , 4715-4722
An aptamer assay using rolling circle amplification coupled with thrombin catalysis for protein detection
We describe a sensitive aptamer-based sandwich assay for protein detection on microplate by using rolling circle amplification (RCA) coupled with thrombin catalysis. This assay takes advantage of RCA generating long DNA oligonucleotides with repeat thrombin-binding aptamer sequence, specific aptamer affinity binding to achieve multiple thrombin labeling, and enzyme activity of thrombin for signal generation. Protein target is specifically captured by antibody-coated microplate. Then, an oligonucleotide containing an aptamer for protein and a primer sequence is added to form a typical sandwich structure. Following a template encoded with complementary sequence of aptamer for thrombin, RCA reaction extends the primer sequence into a long oligonucleotide. Many thrombin molecules bind with the RCA product. Thrombin catalyzes the conversion of its chromogenic or fluorogenic peptide substrates into detectable products for final quantification of protein targets. We applied this strategy to the detection of a model protein target, platelet-derived growth factor-BB (PDGF-BB). Due to double signal amplifications from RCA and thrombin catalysis, this assay enabled the detection of PDGF-BB as low as 3.1 pM when a fluorogenic peptide substrate was used. This assay provides a new way for signal generation in RCA-involved assay through direct thrombin labeling, circumventing time-consuming preparation of enzyme-conjugate and affinity probes. This method has promise for a variety of analytical applications.
- 21 March 2016
- Published by Springer Nature in Microchimica Acta
- Vol. 183 (6) , 1891-1898
Microplate based assay for thrombin detection using an RNA aptamer as affinity ligand and cleavage of a chromogenic or a fluorogenic peptide substrate
- 21 March 2016
- Published by Springer Nature in Microchimica Acta
- Vol. 183 (6) , 1891-1898
Microplate based assay for thrombin detection using an RNA aptamer as affinity ligand and cleavage of a chromogenic or a fluorogenic peptide substrate
- 9 December 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 8 (3) , 510-516
Using fluoro modified RNA aptamers as affinity ligands on magnetic beads for sensitive thrombin detection through affinity capture and thrombin catalysis
RNA aptamer Toggle-25 was used as an affinity ligand on magnetic beads for thrombin detection following affinity capture and enzyme reaction.
- 9 December 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 8 (3) , 510-516
Using fluoro modified RNA aptamers as affinity ligands on magnetic beads for sensitive thrombin detection through affinity capture and thrombin catalysis
RNA aptamer Toggle-25 was used as an affinity ligand on magnetic beads for thrombin detection following affinity capture and enzyme reaction.
- 1 August 2015
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 70, 188-193
Aptamer fluorescence anisotropy sensors for adenosine triphosphate by comprehensive screening tetramethylrhodamine labeled nucleotides
- 1 August 2015
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 70, 188-193
Aptamer fluorescence anisotropy sensors for adenosine triphosphate by comprehensive screening tetramethylrhodamine labeled nucleotides
- 1 April 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 7 (9) , 3888-3892
A fluorescein labeled aptamer switch for thrombin with fluorescence decrease response
An anti-thrombin aptamer with fluorescein labeled at the 3′-end showed a fluorescence decrease upon thrombin binding, enabling the detection of thrombin.
- 1 April 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 7 (9) , 3888-3892
A fluorescein labeled aptamer switch for thrombin with fluorescence decrease response
An anti-thrombin aptamer with fluorescein labeled at the 3′-end showed a fluorescence decrease upon thrombin binding, enabling the detection of thrombin.
- 7 January 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 7 (5) , 1855-1859
Aptamer and rolling circle amplification-involved sandwich assay for platelet-derived growth factor-BB with absorbance analysis
An aptamer-based absorbance assay for PDGF-BB was developed by combining rolling circle amplification reaction and catalysis with horseradish peroxidase.
- 7 January 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 7 (5) , 1855-1859
Aptamer and rolling circle amplification-involved sandwich assay for platelet-derived growth factor-BB with absorbance analysis
An aptamer-based absorbance assay for PDGF-BB was developed by combining rolling circle amplification reaction and catalysis with horseradish peroxidase.
- 10 July 2014
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 63, 21-25
Sensitive and selective detection of thrombin by using a cyclic peptide as affinity ligand
- 10 July 2014
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 63, 21-25
Sensitive and selective detection of thrombin by using a cyclic peptide as affinity ligand
- 31 December 2013
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 86 (2) , 1238-1245
Identification of Allosteric Nucleotide Sites of Tetramethylrhodamine-Labeled Aptamer for Noncompetitive Aptamer-Based Fluorescence Anisotropy Detection of a Small Molecule, Ochratoxin A
Aptamer-based fluorescence anisotropy (FA) assay combines the advantages of affinity aptamers in good stability, easy generation, and facile labeling and the benefits of FA in homogeneous analysis, such as robustness, simplicity, and high reproducibility. By using a fluorophore-labeled aptamer, FA detection of a small molecule is not as easy as detection of protein because the binding of a small molecule cannot cause significant increase of molecular weight of the dye-labeled aptamer. The intramolecular interaction between labeled tetramethylrhodamine (TMR) and DNA aptamer bases dramatically affects the local rotation and FA of TMR. This intramolecular interaction can be altered by aptamer conformation change upon target binding, leading to a significant change of FA of TMR. Taking this unique feature of a TMR-labeled aptamer, we described a noncompetitive aptamer-based fluorescence anisotropy assay for detection of small molecules by using ochratoxin A (OTA) as a model. We successfully identified the specific TMR-labeling sites of aptamers with sensitive FA response to OTA from the 5′-end, 3′-end and the internal thymine (T) bases. The aptamer with a TMR labeled on the 10th T base exhibited a remarkable FA reduction response to OTA (Δr = 0.078), without requiring any proteins or nanomaterials as FA signal enhancers. This FA approach for OTA showed high sensitivity with a detection limit of 3 nM, a dynamic range from 3 nM to 3 μM, and good selectivity over the tested compounds with similar structures to OTA. The new strategy allowed the detection of OTA in diluted red wine and urine samples.
- 31 December 2013
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 86 (2) , 1238-1245
Identification of Allosteric Nucleotide Sites of Tetramethylrhodamine-Labeled Aptamer for Noncompetitive Aptamer-Based Fluorescence Anisotropy Detection of a Small Molecule, Ochratoxin A
Aptamer-based fluorescence anisotropy (FA) assay combines the advantages of affinity aptamers in good stability, easy generation, and facile labeling and the benefits of FA in homogeneous analysis, such as robustness, simplicity, and high reproducibility. By using a fluorophore-labeled aptamer, FA detection of a small molecule is not as easy as detection of protein because the binding of a small molecule cannot cause significant increase of molecular weight of the dye-labeled aptamer. The intramolecular interaction between labeled tetramethylrhodamine (TMR) and DNA aptamer bases dramatically affects the local rotation and FA of TMR. This intramolecular interaction can be altered by aptamer conformation change upon target binding, leading to a significant change of FA of TMR. Taking this unique feature of a TMR-labeled aptamer, we described a noncompetitive aptamer-based fluorescence anisotropy assay for detection of small molecules by using ochratoxin A (OTA) as a model. We successfully identified the specific TMR-labeling sites of aptamers with sensitive FA response to OTA from the 5′-end, 3′-end and the internal thymine (T) bases. The aptamer with a TMR labeled on the 10th T base exhibited a remarkable FA reduction response to OTA (Δr = 0.078), without requiring any proteins or nanomaterials as FA signal enhancers. This FA approach for OTA showed high sensitivity with a detection limit of 3 nM, a dynamic range from 3 nM to 3 μM, and good selectivity over the tested compounds with similar structures to OTA. The new strategy allowed the detection of OTA in diluted red wine and urine samples.
- 4 August 2013
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 405 (25) , 8233-8239
Detection of thrombin using an excimer aptamer switch labeled with dual pyrene molecules
We constructed an excimer aptamer probe containing one pyrene molecule at each end of a DNA aptamer to achieve the detection of thrombin, which binds to the heparin-binding site of thrombin with high binding affinity. The specific binding of thrombin to the excimer aptamer probe brought the two pyrene molecules at the termini of the duplex of the aptamer into close proximity, generating an excimer. The excimer emitted a distinct fluorescence peak, and fluorometric measurement of excimer allowed the sensitive detection of thrombin. The effects of experimental conditions like pH, ionic strength, and cations were investigated and optimized. The detection limit for thrombin was about 42 pM. This aptamer switch has potential in the study of molecular interactions and protein sensing with other switch-based detection strategy.
- 4 August 2013
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 405 (25) , 8233-8239
Detection of thrombin using an excimer aptamer switch labeled with dual pyrene molecules
We constructed an excimer aptamer probe containing one pyrene molecule at each end of a DNA aptamer to achieve the detection of thrombin, which binds to the heparin-binding site of thrombin with high binding affinity. The specific binding of thrombin to the excimer aptamer probe brought the two pyrene molecules at the termini of the duplex of the aptamer into close proximity, generating an excimer. The excimer emitted a distinct fluorescence peak, and fluorometric measurement of excimer allowed the sensitive detection of thrombin. The effects of experimental conditions like pH, ionic strength, and cations were investigated and optimized. The detection limit for thrombin was about 42 pM. This aptamer switch has potential in the study of molecular interactions and protein sensing with other switch-based detection strategy.
- 2 July 2013
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 49 (70) , 7720-7722
An affinity capture involved enzymatic assay for thrombin by using peptide aptamers as affinity ligands on magnetic beads
Here we present a sensitive and specific assay for thrombin through the affinity capture of thrombin with mRNA display generated peptide aptamers on magnetic beads and the subsequent thrombin-involved enzymatic reaction. Thrombin at 50 fM can be detected.
- 2 July 2013
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 49 (70) , 7720-7722
An affinity capture involved enzymatic assay for thrombin by using peptide aptamers as affinity ligands on magnetic beads
Here we present a sensitive and specific assay for thrombin through the affinity capture of thrombin with mRNA display generated peptide aptamers on magnetic beads and the subsequent thrombin-involved enzymatic reaction. Thrombin at 50 fM can be detected.