Shao Yong-Bo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shao Yong-Bo has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Qing-Li Wang
College of Civil Engineering, Shenyang Jianzhu University, Shenyang 110168, China
2 shared publications Cai Y. Q.
1 shared publicationMao M. Y.
1 shared publicationQiu Zhi-Heng
School of Civil Engineering, Guangzhou University, P. R. China, 510006
1 shared publicationSeng-Tjhen Lie
School of Civil & Environmental Engineering, Nanyang Technological University, Nanyang Avenue, Singapore, 639798
1 shared publicationShang Jie-Juan
School of Civil Engineering, Guangzhou University, P. R. China, 510006
1 shared publication
Latest Publications
- Open Access
- 15 July 2011
- Published by Bentham Science Publishers Ltd. in The Open Ocean Engineering Journal
- Vol. 4 (1) , 65-70
Static Strength of Tubular T-joint with Reinforced Chord Under In-plane Bending Load
Static Strength of Tubular T-joint with Reinforced Chord Under In-plane Bending Load
- 15 July 2011
- Published by Bentham Science Publishers Ltd. in The Open Ocean Engineering Journal
- Vol. 4 (1) , 65-70
Open AccessStatic Strength of Tubular T-joint with Reinforced Chord Under In-plane Bending Load
Static Strength of Tubular T-joint with Reinforced Chord Under In-plane Bending Load
- 1 April 2010
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 13 (2) , 369-377
Static Strength of Tubular T-Joints with Reinforced Chord under Axial Compression
A typical tubular T-joint is made up of a chord member and a brace member, and the brace member is connected to the chord surface with full penetration welds. As the stiffness of the chord in the radial direction is much weaker than that of the brace member in the axial direction, failure occurs easily at the weld toe on the chord surface when the chord is subjected to static axial load in the brace axial direction. To improve the static strength of a tubular T-joint, the chord near the weld toe can be reinforced locally by increasing its thickness. To study the effect of the chord reinforcement on the static strength of a tubular T-joint, 48 T-joint models with different reinforcements have been analyzed using the finite element method. The effects of the chord thickness and the length of the reinforced chord on improving the static strength of tubular joints have been investigated. It is found that the static strength can be greatly improved by increasing the chord thickness near the intersection. However, the increased chord thickness should not be much greater than the original chord thickness to avoid changing of the failure mode. On the other hand, it is not effective to improve the static strength by increasing the length of the reinforced chord. The effects of the geometrical parameters and the chord thickness on the static strength of the T-joints are also studied parametrically by analyzing another 240 T-joint models. Finally, a parametric equation is presented, and its accuracy in predicting the static strength of the tubular T-joint subjected to axial compression is verified through error analysis against the numerical results.
- 1 April 2010
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 13 (2) , 369-377
Static Strength of Tubular T-Joints with Reinforced Chord under Axial Compression
A typical tubular T-joint is made up of a chord member and a brace member, and the brace member is connected to the chord surface with full penetration welds. As the stiffness of the chord in the radial direction is much weaker than that of the brace member in the axial direction, failure occurs easily at the weld toe on the chord surface when the chord is subjected to static axial load in the brace axial direction. To improve the static strength of a tubular T-joint, the chord near the weld toe can be reinforced locally by increasing its thickness. To study the effect of the chord reinforcement on the static strength of a tubular T-joint, 48 T-joint models with different reinforcements have been analyzed using the finite element method. The effects of the chord thickness and the length of the reinforced chord on improving the static strength of tubular joints have been investigated. It is found that the static strength can be greatly improved by increasing the chord thickness near the intersection. However, the increased chord thickness should not be much greater than the original chord thickness to avoid changing of the failure mode. On the other hand, it is not effective to improve the static strength by increasing the length of the reinforced chord. The effects of the geometrical parameters and the chord thickness on the static strength of the T-joints are also studied parametrically by analyzing another 240 T-joint models. Finally, a parametric equation is presented, and its accuracy in predicting the static strength of the tubular T-joint subjected to axial compression is verified through error analysis against the numerical results.
- 1 January 2010
- Published by Research Publishing Services
- p. 815-820
Compressive Performaces of the Concrete Filled Circular CFRP-Steel Tubes (2): Theoretical Analysis
- 1 January 2010
- Published by Research Publishing Services
- p. 815-820
Compressive Performaces of the Concrete Filled Circular CFRP-Steel Tubes (2): Theoretical Analysis
- 1 September 2009
- Published by SAGE Publications in International Journal of Space Structures
- Vol. 24 (3) , 161-177
Strength Analysis of Large-Scale Multiplanar Tubular Joints with Inner-Plate Reinforcement
For large scale multiplanar tubular joints used in practical engineering, the brace/chord intersection is a critical position as failure usually occurs here due to the weak bearing capacity of the chord in radius direction compared to the strength of the braces in axial direction. To improve the ultimate strength, different reinforcements can be used to strengthen the structures. Inner plate reinforcement is a relatively new strengthening method compared to conventional reinforcing methods. As there is no corresponding guideline which can be used for the design of inner plate reinforcing joints, it is necessary to investigate the failure mechanism of such tubular structures. Both experimental test and finite element analysis are carried out in this study to investigate the static behaviour of multiplanar tubular joint reinforced with inner plate. In the experimental work, the stresses distribution and development of the specimen is monitored, and the failure mode is observed. From the experimental results, both the failure process of the multiplanar tubular joint and the reinforcing efficiency of the inner plate were analyzed. Using finite element analysis, the failure process of the specimen is also analyzed step by step. The finite element results agree reasonably well with experimental measurements.
- 1 September 2009
- Published by SAGE Publications in International Journal of Space Structures
- Vol. 24 (3) , 161-177
Strength Analysis of Large-Scale Multiplanar Tubular Joints with Inner-Plate Reinforcement
For large scale multiplanar tubular joints used in practical engineering, the brace/chord intersection is a critical position as failure usually occurs here due to the weak bearing capacity of the chord in radius direction compared to the strength of the braces in axial direction. To improve the ultimate strength, different reinforcements can be used to strengthen the structures. Inner plate reinforcement is a relatively new strengthening method compared to conventional reinforcing methods. As there is no corresponding guideline which can be used for the design of inner plate reinforcing joints, it is necessary to investigate the failure mechanism of such tubular structures. Both experimental test and finite element analysis are carried out in this study to investigate the static behaviour of multiplanar tubular joint reinforced with inner plate. In the experimental work, the stresses distribution and development of the specimen is monitored, and the failure mode is observed. From the experimental results, both the failure process of the multiplanar tubular joint and the reinforcing efficiency of the inner plate were analyzed. Using finite element analysis, the failure process of the specimen is also analyzed step by step. The finite element results agree reasonably well with experimental measurements.
- 1 June 2005
- Published by SAGE Publications in International Journal of Space Structures
- Vol. 20 (2) , 83-90
Parametric Equation of Stress Intensity Factor for Tubular K-joints under In-plane Bending Load
Stress intensity factor (SIF) is frequently used by designers to predict the integrity and residual life of a tubular joint containing a surface crack. In this study, a new numerical modelling method for cracked tubular K-joints has been presented. The proposed model has been verified from experimental results to be accurate and reliable in evaluation of the stress intensity factor for any tubular K-joint with a surface crack. Thereafter, parametric study for more than five thousand numerical models of tubular K-joints with a surface crack subjected to balanced in-plane bending load (IPB) has been carried out. A parametric equation to estimate the SIF value of any cracked tubular K-joint under IPB is then proposed based on the computed numerical results. Error analysis has been also carried out and it shows that the proposed equation can provide reliable and accurate estimation of the SIF value for cracked tubular K-joints under IPB.
- 1 June 2005
- Published by SAGE Publications in International Journal of Space Structures
- Vol. 20 (2) , 83-90
Parametric Equation of Stress Intensity Factor for Tubular K-joints under In-plane Bending Load
Stress intensity factor (SIF) is frequently used by designers to predict the integrity and residual life of a tubular joint containing a surface crack. In this study, a new numerical modelling method for cracked tubular K-joints has been presented. The proposed model has been verified from experimental results to be accurate and reliable in evaluation of the stress intensity factor for any tubular K-joint with a surface crack. Thereafter, parametric study for more than five thousand numerical models of tubular K-joints with a surface crack subjected to balanced in-plane bending load (IPB) has been carried out. A parametric equation to estimate the SIF value of any cracked tubular K-joint under IPB is then proposed based on the computed numerical results. Error analysis has been also carried out and it shows that the proposed equation can provide reliable and accurate estimation of the SIF value for cracked tubular K-joints under IPB.