Oliver Hofmann
Research Subjects
Research Interests
Oliver Hofmann has a total of 70 co-authors. Here are the top co-authors by number of shared publications:
- Donal Donat Conor Bradley
Physical Sciences and Engineering (PSE) Division King Abdullah University of Science and Technology (KAUST) Saudi Arabia
7 shared publications John C. Demello
Department of Chemistry and Centre for Plastic Electronics, Imperial College London, London, UK
7 shared publicationsAndrew J. Demello
Department of Chemistry and Centre for Plastic Electronics, Imperial College London, London, UK
5 shared publicationsXuhua Wang
4 shared publications- Andreas Manz
KIST Europe, 66123 Saarbrücken, Germany
3 shared publications - John C. de Mello
Department of Chemistry and Bioengineering, Norwegian University of Science and Technology, Trondheim, Norway
3 shared publications
Latest Publications
- 1 January 2013
- Published by Elsevier
- p. 175-202
Lab-on-a-Chip, Micro- and Nanoscale Immunoassay Systems, and Microarrays
- 1 January 2013
- Published by Elsevier
- p. 175-202
Lab-on-a-Chip, Micro- and Nanoscale Immunoassay Systems, and Microarrays
- 24 March 2011
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 11 (9) , 1664-1670
Highly sensitive fluorescence detection system for microfluidic lab-on-a-chip
We demonstrate a compact, low cost and practical fluorescence detection system for lab-on-a-chip applications. The system comprises a commercially available InGaN light emitting diode (501 nm) as light source, an organic or silicon photodiode detector, absorptive dye coated colour filters and linear and reflective polarisers. An injection moulded polystyrene microfluidic chip is used as the platform for fluorescence immunoassays for cardiac markers myoglobin and CK-MB. The optical limit of detection (LOD) is measured using a TransFluoSphere® suspension at 5.6 × 104 beads µl−1 which can be equated to ∼3 nM fluorescein equivalent concentration. The LOD for the human plasma immunoassays is measured as 1.5 ng ml−1 for both myoglobin and CK-MB.
- 24 March 2011
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 11 (9) , 1664-1670
Highly sensitive fluorescence detection system for microfluidic lab-on-a-chip
We demonstrate a compact, low cost and practical fluorescence detection system for lab-on-a-chip applications. The system comprises a commercially available InGaN light emitting diode (501 nm) as light source, an organic or silicon photodiode detector, absorptive dye coated colour filters and linear and reflective polarisers. An injection moulded polystyrene microfluidic chip is used as the platform for fluorescence immunoassays for cardiac markers myoglobin and CK-MB. The optical limit of detection (LOD) is measured using a TransFluoSphere® suspension at 5.6 × 104 beads µl−1 which can be equated to ∼3 nM fluorescein equivalent concentration. The LOD for the human plasma immunoassays is measured as 1.5 ng ml−1 for both myoglobin and CK-MB.
- 24 February 2011
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 11 (7) , 1228-1233
Non-emissive colour filters for fluorescence detection
We describe a simple technique for fabricating non-emissive colour filters based on the sensitisation of a highly porous nanostructured metal-oxide film with a monolayer of dye molecules. Ultrafast electron transfer at the oxide/dye interface induces efficient quenching of photogenerated excitons in the dye, reducing the photoluminescence quantum yield by many orders of magnitude. The resultant filters exhibit much less autofluorescence than conventional colour filters (where the chromophore is dispersed in a glass or polymer host), and are a viable low cost alternative to interference filters for microfluidic devices and other applications requiring non-emissive filtering.
- 24 February 2011
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 11 (7) , 1228-1233
Non-emissive colour filters for fluorescence detection
We describe a simple technique for fabricating non-emissive colour filters based on the sensitisation of a highly porous nanostructured metal-oxide film with a monolayer of dye molecules. Ultrafast electron transfer at the oxide/dye interface induces efficient quenching of photogenerated excitons in the dye, reducing the photoluminescence quantum yield by many orders of magnitude. The resultant filters exhibit much less autofluorescence than conventional colour filters (where the chromophore is dispersed in a glass or polymer host), and are a viable low cost alternative to interference filters for microfluidic devices and other applications requiring non-emissive filtering.
- 1 July 2009
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 140 (2) , 643-648
Thin-film organic photodiodes for integrated on-chip chemiluminescence detection – application to antioxidant capacity screening
- 1 July 2009
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 140 (2) , 643-648
Thin-film organic photodiodes for integrated on-chip chemiluminescence detection – application to antioxidant capacity screening
- 5 February 2009
- Published by Elsevier
- Vol. 33, 133-169
Chapter 4 Multidimensional fluorescence imaging
- 5 February 2009
- Published by Elsevier
- Vol. 33, 133-169
Chapter 4 Multidimensional fluorescence imaging
- 17 October 2006
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 7 (1) , 58-63
Integrated thin-film polymer/fullerene photodetectors for on-chip microfluidic chemiluminescence detection
We report the use of solution-processed thin-film organic photodiodes for microscale chemiluminescence. The active layer of the photodiodes comprised a 1 : 1 blend by weight of the conjugated polymer poly(3-hexylthiophene) [P3HT] and [6,6]-phenyl-C61-butyric acid-methylester [PCBM]—a soluble derivative of C60. The devices had an active area of 1 mm × 1 mm, and a broad-band response from 350 to 700 nm, with an external quantum efficiency of more than 50% between 450 and 550 nm. The photodiodes have a simple layered structure that permits facile integration with planar chip-based systems. To evaluate the suitability of the organic devices as integrated detectors for microscale chemiluminescence, a peroxyoxalate based chemiluminescence reaction (PO-CL) was monitored within a poly(dimethyl-siloxane) (PDMS) microfluidic device. Quantitation of hydrogen peroxide indicated excellent linearity and yielded a detection limit of 10 µM, comparable with previously reported results using micromachined silicon microfluidic chips with integrated silicon photodiodes. The combination of organic photodiodes with PDMS microfluidic chips offers a means of creating compact, sensitive and potentially low-cost microscale CL devices with wide-ranging applications in chemical and biological analysis and clinical diagnostics.
- 17 October 2006
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 7 (1) , 58-63
Integrated thin-film polymer/fullerene photodetectors for on-chip microfluidic chemiluminescence detection
We report the use of solution-processed thin-film organic photodiodes for microscale chemiluminescence. The active layer of the photodiodes comprised a 1 : 1 blend by weight of the conjugated polymer poly(3-hexylthiophene) [P3HT] and [6,6]-phenyl-C61-butyric acid-methylester [PCBM]—a soluble derivative of C60. The devices had an active area of 1 mm × 1 mm, and a broad-band response from 350 to 700 nm, with an external quantum efficiency of more than 50% between 450 and 550 nm. The photodiodes have a simple layered structure that permits facile integration with planar chip-based systems. To evaluate the suitability of the organic devices as integrated detectors for microscale chemiluminescence, a peroxyoxalate based chemiluminescence reaction (PO-CL) was monitored within a poly(dimethyl-siloxane) (PDMS) microfluidic device. Quantitation of hydrogen peroxide indicated excellent linearity and yielded a detection limit of 10 µM, comparable with previously reported results using micromachined silicon microfluidic chips with integrated silicon photodiodes. The combination of organic photodiodes with PDMS microfluidic chips offers a means of creating compact, sensitive and potentially low-cost microscale CL devices with wide-ranging applications in chemical and biological analysis and clinical diagnostics.
- 9 June 2006
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 6 (8) , 981-987
Monolithically integrated dye-doped PDMS long-pass filters for disposable on-chip fluorescence detection
We report the fabrication of high quality monolithically integrated optical long-pass filters, for use in disposable diagnostic microchips. The filters were prepared by incorporating dye molecules directly into the microfluidic chip substrate, thereby providing a fully integrated solution that removes the usual need for discrete optical filters. In brief, lysochrome dyes were added to a poly(dimethylsiloxane) (PDMS) monomer prior to moulding of the microchip from a structured SU-8 master. Optimum results were obtained using 1 mm layers of PDMS doped with 1200 µg mL−1 Sudan II, which resulted in less than 0.01% transmittance below 500 nm (OD 4), >80% above 570 nm, and negligible autofluorescence. These spectral characteristics compare favourably with commercially available Schott-glass long-pass filters, indicating that high quality optical filters can be straightforwardly integrated into the form of PDMS microfluidic chips. The filters were found to be robust in use, showing only slight degradation after extended illumination and negligible dye leaching after prolonged exposure to aqueous solutions. The provision of low cost high quality integrated filters represents a key step towards the development of high-sensitivity disposable microfluidic devices for point-of-care diagnostics.
- 9 June 2006
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 6 (8) , 981-987
Monolithically integrated dye-doped PDMS long-pass filters for disposable on-chip fluorescence detection
We report the fabrication of high quality monolithically integrated optical long-pass filters, for use in disposable diagnostic microchips. The filters were prepared by incorporating dye molecules directly into the microfluidic chip substrate, thereby providing a fully integrated solution that removes the usual need for discrete optical filters. In brief, lysochrome dyes were added to a poly(dimethylsiloxane) (PDMS) monomer prior to moulding of the microchip from a structured SU-8 master. Optimum results were obtained using 1 mm layers of PDMS doped with 1200 µg mL−1 Sudan II, which resulted in less than 0.01% transmittance below 500 nm (OD 4), >80% above 570 nm, and negligible autofluorescence. These spectral characteristics compare favourably with commercially available Schott-glass long-pass filters, indicating that high quality optical filters can be straightforwardly integrated into the form of PDMS microfluidic chips. The filters were found to be robust in use, showing only slight degradation after extended illumination and negligible dye leaching after prolonged exposure to aqueous solutions. The provision of low cost high quality integrated filters represents a key step towards the development of high-sensitivity disposable microfluidic devices for point-of-care diagnostics.
- 4 March 2006
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 78 (7) , 2272-2278
Quantitative 3D Mapping of Fluidic Temperatures within Microchannel Networks Using Fluorescence Lifetime Imaging
We describe a novel method for quantitatively mapping fluidic temperature with high spatial resolution within microchannels using fluorescence lifetime imaging in an optically sectioning microscope. Unlike intensity-based measurements, this approach is independent of experimental parameters, such as dye concentration and excitation/detection efficiency, thereby facilitating quantitative temperature mapping. Micrometer spatial resolution of 3D temperature distributions is readily achieved with an optical sectioning approach based on two-photon excitation. We demonstrate this technique for mapping of temperature variations across a microfluidic chip under different heating profiles and for mapping of the 3D temperature distribution across a single microchannel under applied flow conditions. This technique allows optimization of the chip design for miniaturized processes, such as on-chip PCR, for which precise temperature control is important.
- 4 March 2006
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 78 (7) , 2272-2278
Quantitative 3D Mapping of Fluidic Temperatures within Microchannel Networks Using Fluorescence Lifetime Imaging
We describe a novel method for quantitatively mapping fluidic temperature with high spatial resolution within microchannels using fluorescence lifetime imaging in an optically sectioning microscope. Unlike intensity-based measurements, this approach is independent of experimental parameters, such as dye concentration and excitation/detection efficiency, thereby facilitating quantitative temperature mapping. Micrometer spatial resolution of 3D temperature distributions is readily achieved with an optical sectioning approach based on two-photon excitation. We demonstrate this technique for mapping of temperature variations across a microfluidic chip under different heating profiles and for mapping of the 3D temperature distribution across a single microchannel under applied flow conditions. This technique allows optimization of the chip design for miniaturized processes, such as on-chip PCR, for which precise temperature control is important.
- 8 August 2005
- Published by Optica Publishing Group in Optics Express
- Vol. 13 (16) , 6275-6285
Time-resolved fluorescence imaging of solvent interactions in microfluidic devices
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
- 8 August 2005
- Published by Optica Publishing Group in Optics Express
- Vol. 13 (16) , 6275-6285
Time-resolved fluorescence imaging of solvent interactions in microfluidic devices
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
- 30 June 2005
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 5 (8) , 863-868
Towards microalbuminuria determination on a disposable diagnostic microchip with integrated fluorescence detection based on thin-film organic light emitting diodes
As a first step towards a fully disposable stand-alone diagnostic microchip for determination of urinary human serum albumin (HSA), we report the use of a thin-film organic light emitting diode (OLED) as an excitation source for microscale fluorescence detection. The OLED has a peak emission wavelength of 540 nm, is simple to fabricate on flexible or rigid substrates, and operates at drive voltages below 10 V. In a fluorescence assay, HSA is reacted with Albumin Blue 580, generating a strong emission at 620 nm when excited with the OLED. Filter-less discrimination between excitation light and generated fluorescence is achieved through an orthogonal detection geometry. When the assay is performed in 800 µm deep and 800 µm wide microchannels on a poly(dimethylsiloxane) (PDMS) microchip at flow rates of 20 µL min−1, HSA concentrations down to 10 mg L−1 can be detected with a linear range from 10 to 100 mg L−1. This sensitivity is sufficient for the determination of microalbuminuria (MAU), an increased urinary albumin excretion indicative of renal disease (clinical cut-off levels: 15–40 mg L−1)
- 30 June 2005
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 5 (8) , 863-868
Towards microalbuminuria determination on a disposable diagnostic microchip with integrated fluorescence detection based on thin-film organic light emitting diodes
As a first step towards a fully disposable stand-alone diagnostic microchip for determination of urinary human serum albumin (HSA), we report the use of a thin-film organic light emitting diode (OLED) as an excitation source for microscale fluorescence detection. The OLED has a peak emission wavelength of 540 nm, is simple to fabricate on flexible or rigid substrates, and operates at drive voltages below 10 V. In a fluorescence assay, HSA is reacted with Albumin Blue 580, generating a strong emission at 620 nm when excited with the OLED. Filter-less discrimination between excitation light and generated fluorescence is achieved through an orthogonal detection geometry. When the assay is performed in 800 µm deep and 800 µm wide microchannels on a poly(dimethylsiloxane) (PDMS) microchip at flow rates of 20 µL min−1, HSA concentrations down to 10 mg L−1 can be detected with a linear range from 10 to 100 mg L−1. This sensitivity is sufficient for the determination of microalbuminuria (MAU), an increased urinary albumin excretion indicative of renal disease (clinical cut-off levels: 15–40 mg L−1)