S. P. Srivastava
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
S. P. Srivastava has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- C. Thanga Raj1 shared publication
- Giribabu Dyanamina
Department of Electrical Engineering, Maulana Azad National Institute of Technology, Bhopal, India
1 shared publication - M.K. Pathak
Department of Electrical Engineering, Indian Institute of Technology Roorkee , Roorkee, India
1 shared publication - Navneet Kumar
Department of Water Resources Development and Management, Indian Institute of Technology Roorkee, India
1 shared publication - Pramod Agarwal
I.I.T. Roorkee
1 shared publication - Pramod Agarwal
Department of Electrical Engineering, Indian Institute of Technology Roorkee, Roorkee, Uttarakhand, India
1 shared publication
Latest Publications
- 2 January 2018
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 65 (1) , 80-95
Modified Reference Model for Rotor Flux-Based MRAS Speed Observer Using Neural Network Controller
The poor low speed performance of rotor flux-based model reference adaptive system (MRAS) is due to the presence of integrator and parameter variation with temperature. To improve low speed performance, a novel rotor flux-based MRAS method is proposed and neural network controller (NNC) is used in place of PI controller in reference model and adaptation mechanism. In this method, a compensating voltage is added to the d–q axis rotor flux equations of induction motor (IM) by modifying voltage model to reduce DC drift and initial value problems of integrator. NNC is implemented in both modified reference model to obtain the drift voltage and in adaptation mechanism to accurately estimate the rotor speed. The proposed scheme is experimentally implemented using dSPACE ds-1104 R&D controller board with improved speed response compared to rotor flux-based MRAS.
- 2 January 2018
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 65 (1) , 80-95
Modified Reference Model for Rotor Flux-Based MRAS Speed Observer Using Neural Network Controller
The poor low speed performance of rotor flux-based model reference adaptive system (MRAS) is due to the presence of integrator and parameter variation with temperature. To improve low speed performance, a novel rotor flux-based MRAS method is proposed and neural network controller (NNC) is used in place of PI controller in reference model and adaptation mechanism. In this method, a compensating voltage is added to the d–q axis rotor flux equations of induction motor (IM) by modifying voltage model to reduce DC drift and initial value problems of integrator. NNC is implemented in both modified reference model to obtain the drift voltage and in adaptation mechanism to accurately estimate the rotor speed. The proposed scheme is experimentally implemented using dSPACE ds-1104 R&D controller board with improved speed response compared to rotor flux-based MRAS.
- 1 July 2015
- Published by Elsevier in ISA Transactions
- Vol. 57, 301-310
Adaptive control schemes for improving dynamic performance of efficiency-optimized induction motor drives
- 1 July 2015
- Published by Elsevier in ISA Transactions
- Vol. 57, 301-310
Adaptive control schemes for improving dynamic performance of efficiency-optimized induction motor drives
- 1 January 2009
- Published by IACSIT Press in International Journal of Computer and Electrical Engineering
- p. 61-70
Energy Efficient Control of Three-Phase Induction Motor - A Review
- 1 January 2009
- Published by IACSIT Press in International Journal of Computer and Electrical Engineering
- p. 61-70
Energy Efficient Control of Three-Phase Induction Motor - A Review
- 1 December 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Performance Analysis of a Three-Phase Squirrel-Cage Induction Motor under Unbalanced Sinusoidal and Balanced Non-Sinusoidal Supply Voltages
As a result of the increasing use of electronic devices and other non-linear loads, the waveforms of the electricity supply voltage are being distorted and inequalities are appearing between the phases. This deterioration is associated with problems of electromagnetic incompatibility and reductions in the efficiency of loads such as motors. This paper investigates the negative effects of unbalanced sinusoidal voltage (0.96% unbalance and 2.9% THD) which always present in the power supply over balanced (inverter supply) non-sinusoidal voltage (23.7% THD) on the performance of induction motor in terms of line currents, power factor and efficiency. Under both supply conditions, the performance of a 5 HP three-phase squirrel cage induction motor was measured through a real load test. According to the test results and analysis, the negative effects of unbalanced sinusoidal voltage are more than the balanced non-sinusoidal voltage on the motor's performance. The financial losses caused by unbalanced voltage of the same motor are determined.
- 1 December 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Performance Analysis of a Three-Phase Squirrel-Cage Induction Motor under Unbalanced Sinusoidal and Balanced Non-Sinusoidal Supply Voltages
As a result of the increasing use of electronic devices and other non-linear loads, the waveforms of the electricity supply voltage are being distorted and inequalities are appearing between the phases. This deterioration is associated with problems of electromagnetic incompatibility and reductions in the efficiency of loads such as motors. This paper investigates the negative effects of unbalanced sinusoidal voltage (0.96% unbalance and 2.9% THD) which always present in the power supply over balanced (inverter supply) non-sinusoidal voltage (23.7% THD) on the performance of induction motor in terms of line currents, power factor and efficiency. Under both supply conditions, the performance of a 5 HP three-phase squirrel cage induction motor was measured through a real load test. According to the test results and analysis, the negative effects of unbalanced sinusoidal voltage are more than the balanced non-sinusoidal voltage on the motor's performance. The financial losses caused by unbalanced voltage of the same motor are determined.