Xinghua Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xinghua Wang has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Daqian Song
College of Chemistry, Jilin University, Changchun, P. R. China
7 shared publicationsDejiang Gao
Changchun Jilin University Little Swan Instruments Co., Ltd
7 shared publicationsFanghui Liang
Changchun Medical College
7 shared publicationsPinyi Ma
Jilin University
7 shared publicationsDi Wang
Jilin University
6 shared publicationsQingqing Yang
Jilin University
6 shared publications
Latest Publications
- 31 October 2016
- Published by Wiley in Journal of Separation Science
- Vol. 39 (23) , 4585-4591
Glass slides functionalized by 1‐carboxyethyl‐3‐methylimidazolium chloride for the determination of triazine herbicides in rice using high‐performance liquid chromatography
A novel and simple supported ionic‐liquid‐based solid‐phase extraction method for the determination of triazine herbicides in rice was developed. Glass slides were functionalized by an ionic liquid, 1‐carboxyethyl‐3‐methylimidazolium chloride, and were used for the simultaneous extraction of seven triazine herbicides in rice samples. The effects of the type of extraction solvent, the extraction time, the type and volume of loading solvent, and the type of eluting solvent on the extraction efficiency were investigated and optimized. Under the optimum operation conditions, the limits of detection for seven triazine herbicides in rice samples obtained by high‐performance liquid chromatography were 3.16–5.42 ng/g, which were lower than the maximum residue levels established by various organizations. The linear correlation coefficients were higher than 0.9975 in the concentration range of 0.015–1.08 μg/g for the seven triazine herbicides. The recoveries of the seven triazine herbicides at the two concentration levels of 0.15 and 0.45 μg/g are between 82.47 and 104.21%, with relative standard deviations of 0.69–9.19%. The intra‐ and inter‐day (n = 5) precisions for all triazine herbicides at the spiked level of 0.30 μg/g were 1.72–11.71%.
- 31 October 2016
- Published by Wiley in Journal of Separation Science
- Vol. 39 (23) , 4585-4591
Glass slides functionalized by 1‐carboxyethyl‐3‐methylimidazolium chloride for the determination of triazine herbicides in rice using high‐performance liquid chromatography
A novel and simple supported ionic‐liquid‐based solid‐phase extraction method for the determination of triazine herbicides in rice was developed. Glass slides were functionalized by an ionic liquid, 1‐carboxyethyl‐3‐methylimidazolium chloride, and were used for the simultaneous extraction of seven triazine herbicides in rice samples. The effects of the type of extraction solvent, the extraction time, the type and volume of loading solvent, and the type of eluting solvent on the extraction efficiency were investigated and optimized. Under the optimum operation conditions, the limits of detection for seven triazine herbicides in rice samples obtained by high‐performance liquid chromatography were 3.16–5.42 ng/g, which were lower than the maximum residue levels established by various organizations. The linear correlation coefficients were higher than 0.9975 in the concentration range of 0.015–1.08 μg/g for the seven triazine herbicides. The recoveries of the seven triazine herbicides at the two concentration levels of 0.15 and 0.45 μg/g are between 82.47 and 104.21%, with relative standard deviations of 0.69–9.19%. The intra‐ and inter‐day (n = 5) precisions for all triazine herbicides at the spiked level of 0.30 μg/g were 1.72–11.71%.
- Open Access
- 23 March 2016
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 54 (5) , 871-877
Molecularly Imprinted Dispersive Solid-Phase Extraction for the Determination of Triazine Herbicides in Grape Seeds by High-Performance Liquid Chromatography
Molecular imprinting technique, regarded as one of the current state-of-the-art researches, was incorporated with the simple dispersive solid-phase extraction (MI-DSPE) in this work for the extraction of triazine herbicides in grape seeds. The atrazine molecularly imprinted polymers (MIPs) were successfully prepared and characterized by scanning electron microscopy and Fourier transform infrared spectroscopy. The imprinting particles were used as the adsorbent in DSPE. Thus, a simple, rapid and selective method based on MIPs coupled with DSPE was established for the simultaneous cleaning-up and quantitative extraction of four triazine herbicides in grape seeds. The experiment parameters, including type of washing solvents, washing time and type of eluting solvents, were investigated and optimized. The performance of the present method was validated by high-performance liquid chromatography. Good linear responses were obtained in concentration range of 0.010–5.0 µg g−1 with correlation coefficients (r2) higher than 0.9993. The recoveries at two spiked levels (1.0 and 2.0 µg g−1) were between 81.2 and 113.0% with relative deviations ranging from 1.2 to 10.7%. The limits of detection were ranged between 0.006 and 0.013 µg g−1, which were lower than the values required by European regulations.
- 23 March 2016
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 54 (5) , 871-877
Open AccessMolecularly Imprinted Dispersive Solid-Phase Extraction for the Determination of Triazine Herbicides in Grape Seeds by High-Performance Liquid Chromatography
Molecular imprinting technique, regarded as one of the current state-of-the-art researches, was incorporated with the simple dispersive solid-phase extraction (MI-DSPE) in this work for the extraction of triazine herbicides in grape seeds. The atrazine molecularly imprinted polymers (MIPs) were successfully prepared and characterized by scanning electron microscopy and Fourier transform infrared spectroscopy. The imprinting particles were used as the adsorbent in DSPE. Thus, a simple, rapid and selective method based on MIPs coupled with DSPE was established for the simultaneous cleaning-up and quantitative extraction of four triazine herbicides in grape seeds. The experiment parameters, including type of washing solvents, washing time and type of eluting solvents, were investigated and optimized. The performance of the present method was validated by high-performance liquid chromatography. Good linear responses were obtained in concentration range of 0.010–5.0 µg g−1 with correlation coefficients (r2) higher than 0.9993. The recoveries at two spiked levels (1.0 and 2.0 µg g−1) were between 81.2 and 113.0% with relative deviations ranging from 1.2 to 10.7%. The limits of detection were ranged between 0.006 and 0.013 µg g−1, which were lower than the values required by European regulations.
- 30 July 2015
- Published by Springer Nature in Food Analytical Methods
- Vol. 9 (4) , 934-941
Determination of 6-Benzylaminopurine and Hg2+ in Bean Sprouts and Drinking Mineral Water by Surface-Enhanced Raman Spectroscopy
- 30 July 2015
- Published by Springer Nature in Food Analytical Methods
- Vol. 9 (4) , 934-941
Determination of 6-Benzylaminopurine and Hg2+ in Bean Sprouts and Drinking Mineral Water by Surface-Enhanced Raman Spectroscopy
- 30 March 2015
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 5 (41) , 32168-32174
Selective and sensitive SERS sensor for detection of Hg2+ in environmental water base on rhodamine-bonded and amino group functionalized SiO2-coated Au–Ag core–shell nanorods
A novel SERS sensor for trace detection of Hg2+ using R6G-derive Schiff base bonded Au@Ag@SiO2–NH2 NRs was designed. The LOD is 0.33 pmol L−1.
- 30 March 2015
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 5 (41) , 32168-32174
Selective and sensitive SERS sensor for detection of Hg2+ in environmental water base on rhodamine-bonded and amino group functionalized SiO2-coated Au–Ag core–shell nanorods
A novel SERS sensor for trace detection of Hg2+ using R6G-derive Schiff base bonded Au@Ag@SiO2–NH2 NRs was designed. The LOD is 0.33 pmol L−1.
- 14 November 2014
- Published by Springer Nature in Microchimica Acta
- Vol. 182 (3-4) , 863-869
Ultrasensitive determination of formaldehyde in environmental waters and food samples after derivatization and using silver nanoparticle assisted SERS
- 14 November 2014
- Published by Springer Nature in Microchimica Acta
- Vol. 182 (3-4) , 863-869
Ultrasensitive determination of formaldehyde in environmental waters and food samples after derivatization and using silver nanoparticle assisted SERS
- 26 August 2014
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 6 (20) , 8388-8395
Simultaneous determination of thiocyanate ion and melamine in milk and milk powder using surface-enhanced Raman spectroscopy
In this study, a simple and efficient method based on surface-enhanced Raman spectroscopy (SERS) was developed to detect thiocyanate ion (SCN−) and melamine in milk and milk powder. Silver nanoparticles (AgNPs), sodium chloride (NaCl) and sodium hydroxide (NaOH) were used as the substrate, the aggregating agent and the alkaline adjusting agent for the SERS process, respectively. The SERS peak intensity at 445 cm−1 was measured under low NaCl concentration for determining SCN−, followed by the measurement of the SERS peak intensity at 704 cm−1 under high NaCl concentration for determining melamine. The determination conditions for SERS, including the amount of AgNPs, NaCl and NaOH, and the mixing time before measurement, were optimized. By the present method, good linear responses were obtained for SCN− and melamine in the concentration ranges of 2.00–191.00 mg L−1 and 0.01–4.80 mg L−1 respectively, with correlation coefficients higher than 0.998. The present method was successfully applied to the simultaneous determination of SCN− and melamine in four spiked milk samples and three certified milk powder samples. The recoveries of SCN− and melamine in spiked milk samples were 95.15–100.47% and 94.43–102.84%, respectively. The relative standard deviations (RSDs) for determining melamine in certified milk powder samples were lower than 1.6%.
- 26 August 2014
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 6 (20) , 8388-8395
Simultaneous determination of thiocyanate ion and melamine in milk and milk powder using surface-enhanced Raman spectroscopy
In this study, a simple and efficient method based on surface-enhanced Raman spectroscopy (SERS) was developed to detect thiocyanate ion (SCN−) and melamine in milk and milk powder. Silver nanoparticles (AgNPs), sodium chloride (NaCl) and sodium hydroxide (NaOH) were used as the substrate, the aggregating agent and the alkaline adjusting agent for the SERS process, respectively. The SERS peak intensity at 445 cm−1 was measured under low NaCl concentration for determining SCN−, followed by the measurement of the SERS peak intensity at 704 cm−1 under high NaCl concentration for determining melamine. The determination conditions for SERS, including the amount of AgNPs, NaCl and NaOH, and the mixing time before measurement, were optimized. By the present method, good linear responses were obtained for SCN− and melamine in the concentration ranges of 2.00–191.00 mg L−1 and 0.01–4.80 mg L−1 respectively, with correlation coefficients higher than 0.998. The present method was successfully applied to the simultaneous determination of SCN− and melamine in four spiked milk samples and three certified milk powder samples. The recoveries of SCN− and melamine in spiked milk samples were 95.15–100.47% and 94.43–102.84%, respectively. The relative standard deviations (RSDs) for determining melamine in certified milk powder samples were lower than 1.6%.
- 27 June 2014
- Published by Springer Nature in Microchimica Acta
- Vol. 182 (1-2) , 167-174
Selective determination of o-phenylenediamine by surface-enhanced Raman spectroscopy using silver nanoparticles decorated with α-cyclodextrin
- 27 June 2014
- Published by Springer Nature in Microchimica Acta
- Vol. 182 (1-2) , 167-174
Selective determination of o-phenylenediamine by surface-enhanced Raman spectroscopy using silver nanoparticles decorated with α-cyclodextrin
- 5 March 2014
- Published by Springer Nature in Food Analytical Methods
- Vol. 7 (9) , 1866-1873
Development and Optimization of a SERS Method for On-site Determination of Nitrite in Foods and Water
- 5 March 2014
- Published by Springer Nature in Food Analytical Methods
- Vol. 7 (9) , 1866-1873
Development and Optimization of a SERS Method for On-site Determination of Nitrite in Foods and Water
- 20 August 2013
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 5 (20) , 5609-5614
Determination of malachite green in environmental water using cloud point extraction coupled with surface-enhanced Raman scattering
A novel, simple and ultra-sensitive method, for rapid detection of trace malachite green (MG) in environmental water using cloud point extraction (CPE) coupled with surface-enhanced Raman scattering (SERS) is described. The colloidal gold nanoparticles (AuNPs) were synthesized by reduction of chloroauric acid (HAuCl4) with trisodium citrate and were used as SERS substrates. The SERS substrates were found to produce enhancement factors of 1.52 × 106 for MG by employing the SERS peak at 1175 cm−1. After the optimization of SERS conditions including the volumes of ethanol, colloidal AuNPs and HCl, the present method was linear for MG at 1175 cm−1 and 1618 cm−1 over the concentration range of 0.5–35.0 μg L−1 and 2.5–40.0 μg L−1, with the correlation coefficients (r) of 0.9971 and 0.9960. The limits of detection (LODs) were 0.10 μg L−1 and 0.70 μg L−1, and the intra- and inter-day relative standard deviations (RSDs) of detection were in the range of 2.0–2.5% and 1.9–3.2% at 1175 cm−1 and 1618 cm−1, respectively. Recoveries obtained by analyzing 4 spiked environmental water samples at 2 levels were between 93.1 and 106.0%.
- 20 August 2013
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 5 (20) , 5609-5614
Determination of malachite green in environmental water using cloud point extraction coupled with surface-enhanced Raman scattering
A novel, simple and ultra-sensitive method, for rapid detection of trace malachite green (MG) in environmental water using cloud point extraction (CPE) coupled with surface-enhanced Raman scattering (SERS) is described. The colloidal gold nanoparticles (AuNPs) were synthesized by reduction of chloroauric acid (HAuCl4) with trisodium citrate and were used as SERS substrates. The SERS substrates were found to produce enhancement factors of 1.52 × 106 for MG by employing the SERS peak at 1175 cm−1. After the optimization of SERS conditions including the volumes of ethanol, colloidal AuNPs and HCl, the present method was linear for MG at 1175 cm−1 and 1618 cm−1 over the concentration range of 0.5–35.0 μg L−1 and 2.5–40.0 μg L−1, with the correlation coefficients (r) of 0.9971 and 0.9960. The limits of detection (LODs) were 0.10 μg L−1 and 0.70 μg L−1, and the intra- and inter-day relative standard deviations (RSDs) of detection were in the range of 2.0–2.5% and 1.9–3.2% at 1175 cm−1 and 1618 cm−1, respectively. Recoveries obtained by analyzing 4 spiked environmental water samples at 2 levels were between 93.1 and 106.0%.