Yuanchao Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yuanchao Wang has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Cheng Cai
College of Material Chemistry and Chemical Engineering, Hangzhou Normal University, Hangzhou, China
3 shared publicationsHeyong Cheng
College of Material Chemistry and Chemical Engineering, Hangzhou Normal University, Hangzhou, 310036, China
3 shared publications- Heyong Cheng
College of Material, Chemistry and Chemical Engineering, Key Laboratory of Organosilicon Chemistry and Material Technology, Ministry of Education, Hangzhou Normal University, 2318 Yuhangtang Road, Hangzhou 311121, China
3 shared publications Jinhua Liu
College of Material Chemistry and Chemical Engineering, Hangzhou Normal University, Hangzhou, 311121, China; Hangzhou Normal University, Qianjiang College, Hangzhou, 310036, China
2 shared publicationsHaifeng Bao
School of Materials Science and Engineering, Wuhan Textile University, Wuhan, China
1 shared publicationHongyan Zhao
College of Material Chemistry and Chemical Engineering, Hangzhou Normal University, Hangzhou, 310036, China
1 shared publication
Latest Publications
- 1 May 2021
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1157, 338388
Simultaneous enrichment of inorganic and organic species of lead and mercury in pg L−1 levels by solid phase extraction online combined with high performance liquid chromatography and inductively coupled plasma mass spectrometry
- 1 May 2021
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1157, 338388
Simultaneous enrichment of inorganic and organic species of lead and mercury in pg L−1 levels by solid phase extraction online combined with high performance liquid chromatography and inductively coupled plasma mass spectrometry
- 7 June 2018
- Published by Wiley in Separation Science Plus
- Vol. 1 (6) , 446-453
Analysis of polycyclic aromatic hydrocarbons by capillary electrochromatography by using capillary columns packed with polycyclic‐aromatic‐hydrocarbon‐specific particles
As a result of their carcinogenic, teratogenic and mutagenic properties, polycyclic aromatic hydrocarbons are considered as priority pollutants by the US Environmental Protection Agency and the analysis of polycyclic aromatic hydrocarbons in environment draws extensive attention in the analytical community. The diversity of polycyclic aromatic hydrocarbons in terms of chemical structures and properties leads to the requirement for highly efficient separation technologies. This study describes the usage of polycyclic‐aromatic‐hydrocarbon‐specific particles as a stationary phase for the separation of polycyclic aromatic hydrocarbons by capillary electrochromatography. A comparison of the separations of 16 polycyclic aromatic hydrocarbons performed on capillary columns packed with polycyclic‐aromatic‐hydrocarbon‐specific particles and C 18 silica microspheres indicated that polycyclic‐aromatic‐hydrocarbon‐specific particles showed a wider distribution and larger gap in chromatographic retention factor (0.6–41.8) toward polycyclic aromatic hydrocarbons than C 18 (2.0–14.2). As a result, resolutions of polycyclic aromatic hydrocarbons on columns packed with polycyclic‐aromatic‐hydrocarbon‐specific particles (1.2–9.9) were significantly superior over those on C 18 ‐packed capillary columns (0.5–6.3). A mobile phase of 20 mM Tris (pH 8.5)/acetonitrile (15:85 v/v) was optimized for the rapid separation of polycyclic aromatic hydrocarbons at a pressurized flow rate of 0.2 mL min −1 under an applied voltage of –16 kV. Limits of detection of 16 polycyclic aromatic hydrocarbons were obtained in the range 0.020–0.89 mg L −1 with good precisions (intracolumn reproducibilities of 0.2–1.9% for retention time, 1.4–4.2% for peak height and 1.4–4.4% for peak area, and intracolumn reproducibilities of 2.6–4.2% for retention time, 3.4–7.2% for peak height and 6.9–9.7% for peak area). The proposed method was employed for polycyclic aromatic hydrocarbons analysis in fresh water with good recovery (87.6–112.4%), where polycyclic aromatic hydrocarbons in all water samples were present at levels below the detection limits.
- 7 June 2018
- Published by Wiley in Separation Science Plus
- Vol. 1 (6) , 446-453
Analysis of polycyclic aromatic hydrocarbons by capillary electrochromatography by using capillary columns packed with polycyclic‐aromatic‐hydrocarbon‐specific particles
As a result of their carcinogenic, teratogenic and mutagenic properties, polycyclic aromatic hydrocarbons are considered as priority pollutants by the US Environmental Protection Agency and the analysis of polycyclic aromatic hydrocarbons in environment draws extensive attention in the analytical community. The diversity of polycyclic aromatic hydrocarbons in terms of chemical structures and properties leads to the requirement for highly efficient separation technologies. This study describes the usage of polycyclic‐aromatic‐hydrocarbon‐specific particles as a stationary phase for the separation of polycyclic aromatic hydrocarbons by capillary electrochromatography. A comparison of the separations of 16 polycyclic aromatic hydrocarbons performed on capillary columns packed with polycyclic‐aromatic‐hydrocarbon‐specific particles and C 18 silica microspheres indicated that polycyclic‐aromatic‐hydrocarbon‐specific particles showed a wider distribution and larger gap in chromatographic retention factor (0.6–41.8) toward polycyclic aromatic hydrocarbons than C 18 (2.0–14.2). As a result, resolutions of polycyclic aromatic hydrocarbons on columns packed with polycyclic‐aromatic‐hydrocarbon‐specific particles (1.2–9.9) were significantly superior over those on C 18 ‐packed capillary columns (0.5–6.3). A mobile phase of 20 mM Tris (pH 8.5)/acetonitrile (15:85 v/v) was optimized for the rapid separation of polycyclic aromatic hydrocarbons at a pressurized flow rate of 0.2 mL min −1 under an applied voltage of –16 kV. Limits of detection of 16 polycyclic aromatic hydrocarbons were obtained in the range 0.020–0.89 mg L −1 with good precisions (intracolumn reproducibilities of 0.2–1.9% for retention time, 1.4–4.2% for peak height and 1.4–4.4% for peak area, and intracolumn reproducibilities of 2.6–4.2% for retention time, 3.4–7.2% for peak height and 6.9–9.7% for peak area). The proposed method was employed for polycyclic aromatic hydrocarbons analysis in fresh water with good recovery (87.6–112.4%), where polycyclic aromatic hydrocarbons in all water samples were present at levels below the detection limits.
- 1 June 2016
- Published by Elsevier in Journal of Chromatography A
- Vol. 1452, 27-35
Graphene oxide decorated monolithic column as stationary phase for capillary electrochromatography
- 1 June 2016
- Published by Elsevier in Journal of Chromatography A
- Vol. 1452, 27-35
Graphene oxide decorated monolithic column as stationary phase for capillary electrochromatography
- 24 October 2014
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 4 (103) , 59157-59163
Mercaptosuccinic acid modified CdTe quantum dots as a selective fluorescence sensor for Ag+determination in aqueous solutions
Water-soluble cadmium telluride quantum dots capped with mercaptosuccinic acid (MSA-CdTe QDs) were prepared for the selective and sensitive fluorescence probing of silver(I) ion. The fluorescence intensity of the MSA-CdTe QDs could be quenched only in the presence of Ag+, and the relative fluorescence intensity was decreased as a linear function of Ag+ concentration. Moreover, the proposed sensor was free from common interfering metal ions. The MSA-CdTe QDs were 3.0 nm in particle size and the maximum photoluminescence wavelength was 558 nm. Better sensitivity was obtained with 4.5 × 10−4 mol L−1 MSA-CdTe QDs in 200 mmol L−1 phosphate buffer (pH 9.0) for a reaction time of 30 min. A linear response between the relative fluorescence intensity, and the concentration of Ag+ was obtained over the range 0.4 to 8 μmol L−1, with a relative standard deviation of 3.6% (n = 5) for 1.5 μmol L−1 and a detection limit of 54 nmol L−1. The proposed method was applied for the determination of Ag+ in two fixer samples at the μmol L−1 level. The spike recovery at a spiked level of 15 μmol L−1 varying from 89.4% to 92.3%, and good agreement between the results by the proposed and AAS methods proved the accuracy of the proposed method.
- 24 October 2014
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 4 (103) , 59157-59163
Mercaptosuccinic acid modified CdTe quantum dots as a selective fluorescence sensor for Ag+determination in aqueous solutions
Water-soluble cadmium telluride quantum dots capped with mercaptosuccinic acid (MSA-CdTe QDs) were prepared for the selective and sensitive fluorescence probing of silver(I) ion. The fluorescence intensity of the MSA-CdTe QDs could be quenched only in the presence of Ag+, and the relative fluorescence intensity was decreased as a linear function of Ag+ concentration. Moreover, the proposed sensor was free from common interfering metal ions. The MSA-CdTe QDs were 3.0 nm in particle size and the maximum photoluminescence wavelength was 558 nm. Better sensitivity was obtained with 4.5 × 10−4 mol L−1 MSA-CdTe QDs in 200 mmol L−1 phosphate buffer (pH 9.0) for a reaction time of 30 min. A linear response between the relative fluorescence intensity, and the concentration of Ag+ was obtained over the range 0.4 to 8 μmol L−1, with a relative standard deviation of 3.6% (n = 5) for 1.5 μmol L−1 and a detection limit of 54 nmol L−1. The proposed method was applied for the determination of Ag+ in two fixer samples at the μmol L−1 level. The spike recovery at a spiked level of 15 μmol L−1 varying from 89.4% to 92.3%, and good agreement between the results by the proposed and AAS methods proved the accuracy of the proposed method.
- 23 January 2014
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 6 (8) , 2767-2773
Determination of pretilachlor in soil and rice using matrix solid-phase dispersion extraction by capillary electrophoresis with field amplified sample injection and electrochemiluminescence detection
A novel method for pretilachlor determination by capillary electrophoresis (CE) with electrochemiluminescence (ECL) detection is proposed. Matrix solid phase dispersion was employed to extract pretilachlor from solid sample matrices and eliminate the interference from majority impurity. The field amplified sample injection technique was used to improve the sensitivity. The CE separation, ECL detection and sample pretreatment are investigated in detail. The linear range of 0.1–10 μmol L−1 with a detection limit (S/N = 3) of 0.02 μmol L−1 is obtained by CE-ECL with the tris(2,2-bipyridine)-ruthenium(II) (Ru(bpy)3 2+–ECL) system. The developed method is successfully applied for the analysis of pretilachlor residues in rice and soil samples. The average recoveries are in the ranges of 88.7–95.5% for rice, and 92.3–93.3% for soil, respectively. The limits of detection of the proposed method were 0.01 mg kg−1 in rice matrix, and 0.008 mg kg−1 in soil matrix, respectively.
- 23 January 2014
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 6 (8) , 2767-2773
Determination of pretilachlor in soil and rice using matrix solid-phase dispersion extraction by capillary electrophoresis with field amplified sample injection and electrochemiluminescence detection
A novel method for pretilachlor determination by capillary electrophoresis (CE) with electrochemiluminescence (ECL) detection is proposed. Matrix solid phase dispersion was employed to extract pretilachlor from solid sample matrices and eliminate the interference from majority impurity. The field amplified sample injection technique was used to improve the sensitivity. The CE separation, ECL detection and sample pretreatment are investigated in detail. The linear range of 0.1–10 μmol L−1 with a detection limit (S/N = 3) of 0.02 μmol L−1 is obtained by CE-ECL with the tris(2,2-bipyridine)-ruthenium(II) (Ru(bpy)3 2+–ECL) system. The developed method is successfully applied for the analysis of pretilachlor residues in rice and soil samples. The average recoveries are in the ranges of 88.7–95.5% for rice, and 92.3–93.3% for soil, respectively. The limits of detection of the proposed method were 0.01 mg kg−1 in rice matrix, and 0.008 mg kg−1 in soil matrix, respectively.
- 31 July 2013
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 5 (19) , 4978-4983
Simultaneous determination of four β2-agonist residues in pig feed and urine by capillary electrophoresis with field amplified sample injection and electrochemiluminescent detection
A novel method for simultaneous determination of clenbuterol (CLB), terbutaline (TER), salbutamol (SAL), and procaterol (PRO) was proposed based on capillary electrophoretic (CE) separation and electrochemiluminescent (ECL) detection. Matrix solid phase dispersion (MSPD) and ion exchange coupled with mesoporous nanocarbon adsorption were adopted to pretreat solid and aqueous samples, respectively. The sensitivity was enhanced by about 9-fold due to the online stacking via field amplified sample injection. The conditions for CE separation and ECL detection were investigated in detail. The four β2-agonists were baseline separated under the optimum conditions within 10 min. The linear ranges were 0.25–10.00 μmol L−1 with detection limits (S/N = 3) of 0.081, 0.076 and 0.034 μmol L−1 for CLB, TER and SAL, respectively, and 0.5–20.00 μmol L−1 for PRO with a detection limit of 0.12 μmol L−1. The developed method was successfully applied to determine the four β2-agonists in real samples, offering average recoveries ranging from 88.9% to 107.1% for pig feed, and from 86.7% to 109.1% for pig urine.
- 31 July 2013
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 5 (19) , 4978-4983
Simultaneous determination of four β2-agonist residues in pig feed and urine by capillary electrophoresis with field amplified sample injection and electrochemiluminescent detection
A novel method for simultaneous determination of clenbuterol (CLB), terbutaline (TER), salbutamol (SAL), and procaterol (PRO) was proposed based on capillary electrophoretic (CE) separation and electrochemiluminescent (ECL) detection. Matrix solid phase dispersion (MSPD) and ion exchange coupled with mesoporous nanocarbon adsorption were adopted to pretreat solid and aqueous samples, respectively. The sensitivity was enhanced by about 9-fold due to the online stacking via field amplified sample injection. The conditions for CE separation and ECL detection were investigated in detail. The four β2-agonists were baseline separated under the optimum conditions within 10 min. The linear ranges were 0.25–10.00 μmol L−1 with detection limits (S/N = 3) of 0.081, 0.076 and 0.034 μmol L−1 for CLB, TER and SAL, respectively, and 0.5–20.00 μmol L−1 for PRO with a detection limit of 0.12 μmol L−1. The developed method was successfully applied to determine the four β2-agonists in real samples, offering average recoveries ranging from 88.9% to 107.1% for pig feed, and from 86.7% to 109.1% for pig urine.