Jianhui Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jianhui Li has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Hideyuki Miyatake
Nano Medical Engineering Laboratory, RIKEN Cluster for Pioneering Research, Emergent Bioengineering Materials Research Team, RIKEN Center for Emergent Matter Science, 2-1 Hirosawa, Wako, Saitama 3510198, Japan
2 shared publications- Yong Mei Chen
College of Bioresources Chemical and Materials Engineering, National Demonstration Center for Experimental Light Chemistry Engineering Education, Shaanxi University of Science and Technology, Xi'an 710021, PR China
2 shared publications - Yoshihiro Ito
Nano Medical Engineering Laboratory, RIKEN Cluster for Pioneering Research, Emergent Bioengineering Materials Research Team, RIKEN Center for Emergent Matter Science, 2-1 Hirosawa, Wako, Saitama 3510198, Japan
2 shared publications - Chuncai Kong
School of Science
1 shared publication Hao Peng Li
Second Affiliated Hospital of Xi'an Jiaotong University, College of Chemistry, Xi'an Jiaotong University, Xi'an 710049, PR China
1 shared publicationHeng Tao Song
Department of Surgical Oncology, Shaanxi Provincial People's Hospital, Xi'an 710068, PR China
1 shared publication
Latest Publications
- Open Access
- 30 December 2025
- Published by Springer Nature in Research Square
Diagnostic Comparison of TI-RADS and a Nomogram for Thyroid Nodules in Northwestern China
Objective The aims of this study were: ① to evaluate the diagnostic efficacy of six mainstream TI-RADS (Thyroid Imaging Reporting and Data System) classification systems (C-TIRADS, ACR-TIRADS, etc.) in the Northwestern Chinese population; and ② to identify risk factors for malignant thyroid nodules (TNs) using logistic regression based on clinical and ultrasound features, construct a quantifiable scoring Nomogram model, enable rapid and objective risk assessment, and assist in clinical decision-making. Methods A total of 2,047 patients with TNs (1,433 malignant and 614 benign) were enrolled from January 2018 to January 2024 at Shaanxi Provincial People’s Hospital. The nodules were divided into a training group (1,435 nodules) and a validation group (612 nodules) in a 7:3 ratio. Twelve characteristics were collected, including age, nodule size, margin, calcification, and the presence of suspicious lymph nodes. Independent risk factors were identified through univariate and multivariate logistic regression analyses to construct a Nomogram model. The model’s performance was evaluated using receiver operating characteristic (ROC) curves, accuracy, and other metrics, and compared with the six traditional TI-RADS systems. Results Ten independent risk factors were identified, including age, nodule size, and irregular margins. In the validation group, the Nomogram model achieved an accuracy of 78.4%, a sensitivity of 81.6%, a specificity of 71.7%, and an area under the ROC curve (AUC) of 0.849. The sensitivities of the six TI-RADS systems (C-TIRADS, ACR-TIRADS, EU-TIRADS, ATA Guidelines, Kwak-TIRADS, and AACE) for distinguishing benign and malignant nodules were 86.0%, 93.2%, 96.9%, 98.3%, 84.4%, and 98.1%, respectively; specificities were 55.6%, 34.8%, 25.3%, 22.2%, 57.1%, and 21.7%, respectively; accuracies were 76.1%, 74.3%, 73.7%, 73.7%, 75.8%, and 73.4%, respectively; and AUCs were 0.752, 0.661, 0.628, 0.617, 0.757, and 0.616, respectively, with no statistically significant differences among them. The Nomogram model significantly outperformed the traditional systems in measures such as AUC, Net Reclassification Improvement (NRI), Integrated Discrimination Improvement (IDI), Positive Likelihood Ratio (PLR), and Negative Likelihood Ratio (NLR) (P < 0.001). Conclusion The six traditional TI-RADS systems demonstrate similar but overall limited diagnostic efficacy in the Northwestern Chinese population. The Nomogram model, by integrating multidimensional features and applying a quantitative scoring approach, improves the accuracy and objectivity of malignancy risk assessment. Compared to traditional models, it offers better clinical utility, supports optimized decision-making, and helps reduce unnecessary invasive procedures.
- 30 December 2025
- Published by Springer Nature in Research Square
Open AccessDiagnostic Comparison of TI-RADS and a Nomogram for Thyroid Nodules in Northwestern China
Objective The aims of this study were: ① to evaluate the diagnostic efficacy of six mainstream TI-RADS (Thyroid Imaging Reporting and Data System) classification systems (C-TIRADS, ACR-TIRADS, etc.) in the Northwestern Chinese population; and ② to identify risk factors for malignant thyroid nodules (TNs) using logistic regression based on clinical and ultrasound features, construct a quantifiable scoring Nomogram model, enable rapid and objective risk assessment, and assist in clinical decision-making. Methods A total of 2,047 patients with TNs (1,433 malignant and 614 benign) were enrolled from January 2018 to January 2024 at Shaanxi Provincial People’s Hospital. The nodules were divided into a training group (1,435 nodules) and a validation group (612 nodules) in a 7:3 ratio. Twelve characteristics were collected, including age, nodule size, margin, calcification, and the presence of suspicious lymph nodes. Independent risk factors were identified through univariate and multivariate logistic regression analyses to construct a Nomogram model. The model’s performance was evaluated using receiver operating characteristic (ROC) curves, accuracy, and other metrics, and compared with the six traditional TI-RADS systems. Results Ten independent risk factors were identified, including age, nodule size, and irregular margins. In the validation group, the Nomogram model achieved an accuracy of 78.4%, a sensitivity of 81.6%, a specificity of 71.7%, and an area under the ROC curve (AUC) of 0.849. The sensitivities of the six TI-RADS systems (C-TIRADS, ACR-TIRADS, EU-TIRADS, ATA Guidelines, Kwak-TIRADS, and AACE) for distinguishing benign and malignant nodules were 86.0%, 93.2%, 96.9%, 98.3%, 84.4%, and 98.1%, respectively; specificities were 55.6%, 34.8%, 25.3%, 22.2%, 57.1%, and 21.7%, respectively; accuracies were 76.1%, 74.3%, 73.7%, 73.7%, 75.8%, and 73.4%, respectively; and AUCs were 0.752, 0.661, 0.628, 0.617, 0.757, and 0.616, respectively, with no statistically significant differences among them. The Nomogram model significantly outperformed the traditional systems in measures such as AUC, Net Reclassification Improvement (NRI), Integrated Discrimination Improvement (IDI), Positive Likelihood Ratio (PLR), and Negative Likelihood Ratio (NLR) (P < 0.001). Conclusion The six traditional TI-RADS systems demonstrate similar but overall limited diagnostic efficacy in the Northwestern Chinese population. The Nomogram model, by integrating multidimensional features and applying a quantitative scoring approach, improves the accuracy and objectivity of malignancy risk assessment. Compared to traditional models, it offers better clinical utility, supports optimized decision-making, and helps reduce unnecessary invasive procedures.
- 5 March 2024
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 264, 130568
Mussel inspired sequential protein delivery based on self-healing injectable nanocomposite hydrogel
- 5 March 2024
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 264, 130568
Mussel inspired sequential protein delivery based on self-healing injectable nanocomposite hydrogel
- 30 May 2016
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 40 (8) , 6573-6576
Facet-dependent nonenzymatic glucose sensing properties of Cu2O cubes and octahedra
Cu2O cubes and octahedra which have different crystallographic facets have been used for the nonenzymatic glucose sensors. A Cu2O octahedra modified electrode shows higher sensitivity, lower detection limit, and wider linear range than that of the cubes.
- 30 May 2016
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 40 (8) , 6573-6576
Facet-dependent nonenzymatic glucose sensing properties of Cu2O cubes and octahedra
Cu2O cubes and octahedra which have different crystallographic facets have been used for the nonenzymatic glucose sensors. A Cu2O octahedra modified electrode shows higher sensitivity, lower detection limit, and wider linear range than that of the cubes.
- Open Access
- 1 June 2014
- Published by Chinese Medical Sciences Journal in Chinese Medical Sciences Journal
- Vol. 29 (2) , 91-97
Healing of Stoma After Magnetic Biliary-Enteric Anastomosis in Canine Peritonitis Models
Objective: To assese the healing of stoma after magnetic anastomosis for the reconstruction of biliary-enteric continuity under severe inflammation. Methods: Acute bile duct injury was constructed as a bile peritonitis model in mongrel dogs (n=32). Magnetic anastomosis (group A, n=16) and traditional suture anastomosis (group B, n=16) were performed to reconstruct the biliary-enteric continuity in one stage. Half of the dogs in each group were euthanized on the 30th postoperative day, and the other half on the 90th postoperative day to harvest the stoma region. The healing conditions of the stoma after the 2 anastomotic approaches were observed with naked eyes, under light microscope and scanning electron microscope. Results: The stoma leakage rate (50% versus 0% on the 30th postoperative day, 37.5% versus 12.5% on the 90th postoperative day, both Pversus 7.1%±0.3% on the 30th postoperative day, 17.2%±0.4% versus 9.4%±0.4% on the 90th postoperative day, both P<0.01) were significantly higher in group B than in group A. Compared with traditional manual anastomoses, the histological analysis under light and electron microscope showed a more continuous stoma with more regular epithelium proliferation and collagen arrangement, less inflammation in group A. Conclusions: Magnetic anastomosis stent ensures better healing of the stoma even under the circumstance of severe inflammation.
- 1 June 2014
- Published by Chinese Medical Sciences Journal in Chinese Medical Sciences Journal
- Vol. 29 (2) , 91-97
Open AccessHealing of Stoma After Magnetic Biliary-Enteric Anastomosis in Canine Peritonitis Models
Objective: To assese the healing of stoma after magnetic anastomosis for the reconstruction of biliary-enteric continuity under severe inflammation. Methods: Acute bile duct injury was constructed as a bile peritonitis model in mongrel dogs (n=32). Magnetic anastomosis (group A, n=16) and traditional suture anastomosis (group B, n=16) were performed to reconstruct the biliary-enteric continuity in one stage. Half of the dogs in each group were euthanized on the 30th postoperative day, and the other half on the 90th postoperative day to harvest the stoma region. The healing conditions of the stoma after the 2 anastomotic approaches were observed with naked eyes, under light microscope and scanning electron microscope. Results: The stoma leakage rate (50% versus 0% on the 30th postoperative day, 37.5% versus 12.5% on the 90th postoperative day, both Pversus 7.1%±0.3% on the 30th postoperative day, 17.2%±0.4% versus 9.4%±0.4% on the 90th postoperative day, both P<0.01) were significantly higher in group B than in group A. Compared with traditional manual anastomoses, the histological analysis under light and electron microscope showed a more continuous stoma with more regular epithelium proliferation and collagen arrangement, less inflammation in group A. Conclusions: Magnetic anastomosis stent ensures better healing of the stoma even under the circumstance of severe inflammation.