Carlos Ubide
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Carlos Ubide has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Guillermo López-Cueto
Departamento de Química Analítica, Facultad de Ciencias, Universidad de Alicante, Apdo. 99, 03080 Alicante, Spain
7 shared publications - Miren Ostra
Department of Applied Chemistry, University of the Basque Country (UPV/EHU), 20018, Donostia/San Sebastian, Spain
6 shared publications J Zuriarrain
Departamento de Quı́mica Aplicada, Facultad de Quı́mica, Universidad del Paı́s Vasco, Apdo. 1072, 20080-San Sebastián, Spain
1 shared publicationJorge Lizarreta
Departamento de Quı́mica Aplicada, Facultad de Quı́mica, Universidad del Paı́s Vasco, Apdo 1072, 20080 San Sebastián, Spain
1 shared publicationR. Angulo
Departamento de Química Aplicada, Facultad de Química, Universidad del País Vasco, Apdo. 1072, 20080 San Sebastián, Spain
1 shared publicationRosa García
Departamento de Química Aplicada, Facultad de Química, Universidad del País Vasco, Apdo. 1072, 20080-San Sebastián, Spain
1 shared publication
Latest Publications
- 11 April 2005
- Published by Elsevier in Analytica Chimica Acta
- Vol. 535 (1) , 287-295
Multicomponent determinations using addition-generated reagent profiles and partial least squares regression
- 11 April 2005
- Published by Elsevier in Analytica Chimica Acta
- Vol. 535 (1) , 287-295
Multicomponent determinations using addition-generated reagent profiles and partial least squares regression
- 5 July 2004
- Published by Elsevier in Analytica Chimica Acta
- Vol. 515 (1) , 109-116
Fenton’s reagent for kinetic determinations
- 5 July 2004
- Published by Elsevier in Analytica Chimica Acta
- Vol. 515 (1) , 109-116
Fenton’s reagent for kinetic determinations
- 1 November 2002
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 374 (5) , 915-922
The acetylsalicylic acid-bromine system for multicomponent kinetic determinations
When acetylsalicylic acid (ASA) is added to a bromine solution, slow decay of the bromine concentration occurs. Hydrolysis of ASA yields salicylic acid (SA) slowly, and bromine reacts rapidly with SA but not with ASA. Simulated reaction profiles based on a two-step reaction scheme agree closely with the experimental profiles. This behaviour can be used to develop kinetic methods for resolution of mixtures of ASA and a second component that reacts rapidly with bromine. A remarkable practical feature of these methods is that the faster the reaction between bromine and the second component, the simpler and easier the analytical method. The reaction between hydroquinone (HQ) and bromine is rapid and a very simple analytical method is proposed. Mean validation errors of 2.8% for HQ and 7.2% for ASA have been found with concentration ratios [ASA]:[HQ] ranging between 0.32 and 19.4. The reaction between paracetamol (AAP) and bromine is not so fast and more complicated calibration methods are required. After use of a calibration plane mean validation errors of 2.7% for AAP and 8.1% for ASA have been found with concentration ratios ranging between 1.28 and 77.5. Similar kinetic approaches should be possible with many other mixtures of ASA and a second fast-reacting component, because bromine reacts with many inorganic and organic species by oxidation–reduction, substitution, and addition reactions.
- 1 November 2002
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 374 (5) , 915-922
The acetylsalicylic acid-bromine system for multicomponent kinetic determinations
When acetylsalicylic acid (ASA) is added to a bromine solution, slow decay of the bromine concentration occurs. Hydrolysis of ASA yields salicylic acid (SA) slowly, and bromine reacts rapidly with SA but not with ASA. Simulated reaction profiles based on a two-step reaction scheme agree closely with the experimental profiles. This behaviour can be used to develop kinetic methods for resolution of mixtures of ASA and a second component that reacts rapidly with bromine. A remarkable practical feature of these methods is that the faster the reaction between bromine and the second component, the simpler and easier the analytical method. The reaction between hydroquinone (HQ) and bromine is rapid and a very simple analytical method is proposed. Mean validation errors of 2.8% for HQ and 7.2% for ASA have been found with concentration ratios [ASA]:[HQ] ranging between 0.32 and 19.4. The reaction between paracetamol (AAP) and bromine is not so fast and more complicated calibration methods are required. After use of a calibration plane mean validation errors of 2.7% for AAP and 8.1% for ASA have been found with concentration ratios ranging between 1.28 and 77.5. Similar kinetic approaches should be possible with many other mixtures of ASA and a second fast-reacting component, because bromine reacts with many inorganic and organic species by oxidation–reduction, substitution, and addition reactions.
- 25 October 2001
- Published by Elsevier in Analytica Chimica Acta
- Vol. 445 (1) , 117-126
New way of application of the bromate–bromide mixture in kinetic analysis
- 25 October 2001
- Published by Elsevier in Analytica Chimica Acta
- Vol. 445 (1) , 117-126
New way of application of the bromate–bromide mixture in kinetic analysis
- 24 January 2000
- Published by Elsevier in Analytica Chimica Acta
- Vol. 405 (1-2) , 285-295
Linear and non-linear multivariate calibration methods for multicomponent kinetic determinations in cases of severe non-linearity
- 24 January 2000
- Published by Elsevier in Analytica Chimica Acta
- Vol. 405 (1-2) , 285-295
Linear and non-linear multivariate calibration methods for multicomponent kinetic determinations in cases of severe non-linearity