Richard A. Mathies
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Richard A. Mathies has a total of 103 co-authors. Here are the top co-authors by number of shared publications:
- David W. McCamant
Department of Chemistry, University of Rochester, 120 Trustee Rd, Rochester, NY14627, USA
8 shared publications - Philipp Kukura
University of Oxford
8 shared publications James R. Scherer
6 shared publicationsJudy E. Kim
Department of Chemistry, University of California, Berkeley, California 94720, USA
6 shared publicationsCharles A. Emrich
Biophysics Graduate Group, University of California, Berkeley, CA 94720
5 shared publications- Brian Matthew Paegel
Department of Pharmaceutical Sciences & Center for Neurotherapeutics, University of California, Irvine, California 92697, United States
4 shared publications
Latest Publications
- 27 December 2010
- Published by Wiley in Laser & Photonics Reviews
- Vol. 5 (1) , 102-113
Femtosecond stimulated Raman spectroscopy
Advances in the field of Femtosecond Stimulated Raman Spectroscopy (FSRS), a new time‐resolved structural technique that provides complete vibrational spectra on the ultrafast timescale, are reviewed. When coupled with a femtosecond optical trigger, the time evolution of a reacting species can be monitored with unprecedented ‐1 spectral resolution. New technological and theoretical advances including the development of tunable FSRS and a background‐free FSRS format are discussed. The most recent experimental studies focus on ultrafast reaction dynamics in electronically excited states: isomerization in cyanobacterial phytochrome, ultrafast spin flipping in a solar cell sensitizer, and excited state proton transfer in green fluorescent protein. The use of FSRS to directly map multidimensional reactive potential energy surfaces and to probe the mechanism of reactive internal conversion is prospectively discussed.
- 27 December 2010
- Published by Wiley in Laser & Photonics Reviews
- Vol. 5 (1) , 102-113
Femtosecond stimulated Raman spectroscopy
Advances in the field of Femtosecond Stimulated Raman Spectroscopy (FSRS), a new time‐resolved structural technique that provides complete vibrational spectra on the ultrafast timescale, are reviewed. When coupled with a femtosecond optical trigger, the time evolution of a reacting species can be monitored with unprecedented ‐1 spectral resolution. New technological and theoretical advances including the development of tunable FSRS and a background‐free FSRS format are discussed. The most recent experimental studies focus on ultrafast reaction dynamics in electronically excited states: isomerization in cyanobacterial phytochrome, ultrafast spin flipping in a solar cell sensitizer, and excited state proton transfer in green fluorescent protein. The use of FSRS to directly map multidimensional reactive potential energy surfaces and to probe the mechanism of reactive internal conversion is prospectively discussed.
- 23 July 2009
- Published by Springer Nature
- p. 310-312
Origin of Negative and Dispersive Features in Resonance Femtosecond Stimulated Raman Spectroscopy
- 23 July 2009
- Published by Springer Nature
- p. 310-312
Origin of Negative and Dispersive Features in Resonance Femtosecond Stimulated Raman Spectroscopy
- 2 April 2009
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 81 (9) , 3523-3528
Integrated Capture, Concentration, Polymerase Chain Reaction, and Capillary Electrophoretic Analysis of Pathogens on a Chip
A laboratory-on-a-chip system for pathogen detection is presented that integrates cell preconcentration, purification, polymerase chain reaction (PCR), and capillary electrophoretic (CE) analysis. The microdevice is composed of micropumps and valves, a cell capture structure, a 100 nL PCR reactor, and a 5 cm long CE column for amplicon separation. Sample volumes ranging from 10 to 100 μL are introduced and driven through a fluidized bed of magnetically constrained immunomagnetic beads where the target cells are captured. After cell capture, beads are transferred using the on-chip pumps to the PCR reactor for DNA amplification. The resulting PCR products are electrophoretically injected onto the CE column for separation and detection of Escherichia coli K12 and E. coli O157 targets. A detection limit of 0.2 cfu/μL is achieved using the E. coli O157 target and an input volume of 50 μL. Finally, the sensitive detection of E. coli O157 in the presence of K12 at a ratio of 1:1000 illustrates the capability of our system to identify target cells in a high commensal background. This cell capture-PCR-CE microsystem is a significant advance in the development of rapid, sensitive, and specific laboratory-on-a-chip devices for pathogen detection.
- 2 April 2009
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 81 (9) , 3523-3528
Integrated Capture, Concentration, Polymerase Chain Reaction, and Capillary Electrophoretic Analysis of Pathogens on a Chip
A laboratory-on-a-chip system for pathogen detection is presented that integrates cell preconcentration, purification, polymerase chain reaction (PCR), and capillary electrophoretic (CE) analysis. The microdevice is composed of micropumps and valves, a cell capture structure, a 100 nL PCR reactor, and a 5 cm long CE column for amplicon separation. Sample volumes ranging from 10 to 100 μL are introduced and driven through a fluidized bed of magnetically constrained immunomagnetic beads where the target cells are captured. After cell capture, beads are transferred using the on-chip pumps to the PCR reactor for DNA amplification. The resulting PCR products are electrophoretically injected onto the CE column for separation and detection of Escherichia coli K12 and E. coli O157 targets. A detection limit of 0.2 cfu/μL is achieved using the E. coli O157 target and an input volume of 50 μL. Finally, the sensitive detection of E. coli O157 in the presence of K12 at a ratio of 1:1000 illustrates the capability of our system to identify target cells in a high commensal background. This cell capture-PCR-CE microsystem is a significant advance in the development of rapid, sensitive, and specific laboratory-on-a-chip devices for pathogen detection.
- 23 December 2008
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 105 (51) , 20173-20178
Integrated microfluidic bioprocessor for single-cell gene expression analysis
An integrated microdevice is developed for the analysis of gene expression in single cells. The system captures a single cell, transcribes and amplifies the mRNA, and quantitatively analyzes the products of interest. The key components of the microdevice include integrated nanoliter metering pumps, a 200-nL RT-PCR reactor with a single-cell capture pad, and an affinity capture matrix for the purification and concentration of products that is coupled to a microfabricated capillary electrophoresis separation channel for product analysis. Efficient microchip integration of these processes enables the sensitive and quantitative examination of gene expression variation at the single-cell level. This microdevice is used to measure siRNA knockdown of the GAPDH gene in individual Jurkat cells. Single-cell measurements suggests the presence of 2 distinct populations of cells with moderate (≈50%) or complete (≈0%) silencing. This stochastic variation in gene expression and silencing within single cells is masked by conventional bulk measurements.
- 23 December 2008
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 105 (51) , 20173-20178
Integrated microfluidic bioprocessor for single-cell gene expression analysis
An integrated microdevice is developed for the analysis of gene expression in single cells. The system captures a single cell, transcribes and amplifies the mRNA, and quantitatively analyzes the products of interest. The key components of the microdevice include integrated nanoliter metering pumps, a 200-nL RT-PCR reactor with a single-cell capture pad, and an affinity capture matrix for the purification and concentration of products that is coupled to a microfabricated capillary electrophoresis separation channel for product analysis. Efficient microchip integration of these processes enables the sensitive and quantitative examination of gene expression variation at the single-cell level. This microdevice is used to measure siRNA knockdown of the GAPDH gene in individual Jurkat cells. Single-cell measurements suggests the presence of 2 distinct populations of cells with moderate (≈50%) or complete (≈0%) silencing. This stochastic variation in gene expression and silencing within single cells is masked by conventional bulk measurements.
- Open Access
- 20 October 2008
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 39 (11) , 1526-1530
Femtosecond Raman‐induced Kerr effect spectroscopy
We report the development of a new vibrational technique called Femtosecond Raman‐Induced Kerr Effect Spectroscopy (FRIKES). This technique combines a narrow‐bandwidth picosecond Raman pump pulse with a broadband femtosecond probe pulse to produce high‐resolution Raman‐induced Kerr effect spectra spanning a large vibrational range. Because it is a polarization detection technique, FRIKES produces background‐free Raman spectra with high signal‐to‐noise and rapid acquisition times. The practicality of FRIKES is demonstrated by obtaining Raman spectra of common solvents, revealing that its performance is comparable to femtosecond stimulated Raman spectroscopy (FSRS). The capabilities of FRIKES will make it a valuable new vibrational spectroscopic tool for studies of chemical and biological systems, especially once it is extended to time‐resolved studies. Copyright © 2008 John Wiley & Sons, Ltd.
- 20 October 2008
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 39 (11) , 1526-1530
Open AccessFemtosecond Raman‐induced Kerr effect spectroscopy
We report the development of a new vibrational technique called Femtosecond Raman‐Induced Kerr Effect Spectroscopy (FRIKES). This technique combines a narrow‐bandwidth picosecond Raman pump pulse with a broadband femtosecond probe pulse to produce high‐resolution Raman‐induced Kerr effect spectra spanning a large vibrational range. Because it is a polarization detection technique, FRIKES produces background‐free Raman spectra with high signal‐to‐noise and rapid acquisition times. The practicality of FRIKES is demonstrated by obtaining Raman spectra of common solvents, revealing that its performance is comparable to femtosecond stimulated Raman spectroscopy (FSRS). The capabilities of FRIKES will make it a valuable new vibrational spectroscopic tool for studies of chemical and biological systems, especially once it is extended to time‐resolved studies. Copyright © 2008 John Wiley & Sons, Ltd.
- 3 August 2008
- Published by Springer Nature in Biomedical Microdevices
- Vol. 10 (6) , 909-917
Immunomagnetic bead-based cell concentration microdevice for dilute pathogen detection
A cell concentration microdevice for immunomagnetic pathogen isolation from a dilute sample is presented. Cells are driven by integrated on-chip pumps through a fluidized bed of immobilized immunomagnetic beads. Off-chip polymerase chain reaction and capillary electrophoretic analysis are used to determine capture efficiencies of E. coli and to optimize the system. Beads are immobilized after each split in a bifurcated channel system to ensure a balanced distribution of beads in all the capture channels. The addition of a pumping flutter step to repeatedly drive sample through the bead bed was found to enhance capture. Capture efficiencies of 70% and a limit of detection of 2 cfu/μL were achieved; specific capture of E. coli at a concentration of 100 cfu/μL in a 100-fold background of S. aureus is shown. This capture/concentration system is an important step in overcoming the macro-to-micro interface challenge in the development of microdevices for pathogen detection.
- 3 August 2008
- Published by Springer Nature in Biomedical Microdevices
- Vol. 10 (6) , 909-917
Immunomagnetic bead-based cell concentration microdevice for dilute pathogen detection
A cell concentration microdevice for immunomagnetic pathogen isolation from a dilute sample is presented. Cells are driven by integrated on-chip pumps through a fluidized bed of immobilized immunomagnetic beads. Off-chip polymerase chain reaction and capillary electrophoretic analysis are used to determine capture efficiencies of E. coli and to optimize the system. Beads are immobilized after each split in a bifurcated channel system to ensure a balanced distribution of beads in all the capture channels. The addition of a pumping flutter step to repeatedly drive sample through the bead bed was found to enhance capture. Capture efficiencies of 70% and a limit of detection of 2 cfu/μL were achieved; specific capture of E. coli at a concentration of 100 cfu/μL in a 100-fold background of S. aureus is shown. This capture/concentration system is an important step in overcoming the macro-to-micro interface challenge in the development of microdevices for pathogen detection.
- 11 June 2008
- Published by Wiley in Electrophoresis
- Vol. 29 (11) , 2251-2259
Fluorescence energy transfer‐labeled primers for high‐performance forensic DNA profiling
A fluorescence energy transfer (ET) dye‐labeled STR typing system (ET 16‐plex) is developed for the markers used in the commercial STR typing kit PowerPlex 16, and its performance assessed using a 96‐lane microfabricated capillary array electrophoresis (μCAE) system. The ET 16‐plex amplicons displayed 1.6–9‐fold higher fluorescence intensities compared to those produced using the single‐dye (SD)‐labeled multiplex kits. The ET multiplex delivered full STR profiles from 62.5 pg of DNA; half the input required for the SD kits while maintaining a similar heterozygote allele balance. This increased sensitivity should improve typing of poor‐quality DNA samples by making minor or imbalanced alleles more readily detectable at the low copy number (LCN) threshold. The ET 16‐plex also generated complete profiles with only 28 PCR cycles; this capability should improve LCN typing by reducing the amplification time and drop‐in allele incidence. To confirm the practical advantages of ET‐labeled primers, six previously problematic casework samples were tested and only the ET 16‐plex kit was able to capture additional allele data. The successful development and demonstration of ET primers for higher sensitivity STR typing offers a simple solution to improving current commercial multiplex typing capability. The superior spectral properties and universal compatibility with any primer sequence provided by ET cassettes will make future multiplex construction more facile and straightforward. The pairing of ET cassette technology with the μCAE system illustrates not only an enhanced STR typing platform, but a significant step toward a higher‐efficiency forensic laboratory enabled by better chemistry and microfluidics.
- 11 June 2008
- Published by Wiley in Electrophoresis
- Vol. 29 (11) , 2251-2259
Fluorescence energy transfer‐labeled primers for high‐performance forensic DNA profiling
A fluorescence energy transfer (ET) dye‐labeled STR typing system (ET 16‐plex) is developed for the markers used in the commercial STR typing kit PowerPlex 16, and its performance assessed using a 96‐lane microfabricated capillary array electrophoresis (μCAE) system. The ET 16‐plex amplicons displayed 1.6–9‐fold higher fluorescence intensities compared to those produced using the single‐dye (SD)‐labeled multiplex kits. The ET multiplex delivered full STR profiles from 62.5 pg of DNA; half the input required for the SD kits while maintaining a similar heterozygote allele balance. This increased sensitivity should improve typing of poor‐quality DNA samples by making minor or imbalanced alleles more readily detectable at the low copy number (LCN) threshold. The ET 16‐plex also generated complete profiles with only 28 PCR cycles; this capability should improve LCN typing by reducing the amplification time and drop‐in allele incidence. To confirm the practical advantages of ET‐labeled primers, six previously problematic casework samples were tested and only the ET 16‐plex kit was able to capture additional allele data. The successful development and demonstration of ET primers for higher sensitivity STR typing offers a simple solution to improving current commercial multiplex typing capability. The superior spectral properties and universal compatibility with any primer sequence provided by ET cassettes will make future multiplex construction more facile and straightforward. The pairing of ET cassette technology with the μCAE system illustrates not only an enhanced STR typing platform, but a significant step toward a higher‐efficiency forensic laboratory enabled by better chemistry and microfluidics.
- 27 March 2008
- Published by Wiley in Chemphyschem
- Vol. 9 (5) , 697-699
Resonance Raman Cross‐Sections and Vibronic Analysis of Rhodamine 6G from Broadband Stimulated Raman Spectroscopy
- 27 March 2008
- Published by Wiley in Chemphyschem
- Vol. 9 (5) , 697-699
Resonance Raman Cross‐Sections and Vibronic Analysis of Rhodamine 6G from Broadband Stimulated Raman Spectroscopy
- 19 September 2007
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 7 (11) , 1442-1448
Self-assembled cellular microarrays patterned using DNA barcodes
The successful integration of living cells into synthetic devices requires precise control over cell patterning. Here we describe a versatile platform that can accomplish this goal through DNA hybridization. Living cells functionalized with exogenous cell-surface DNA strands bind to cognate sequences of DNA printed on glass slides. Attachment via these “cell-adhesion barcodes” is rapid and specific, with close-packed arrays of cells forming within minutes. The biophysical properties of the system are characterized, and the technique is used to form complex cellular patterns with single-cell line widths and self-assembled cellular microarrays. Key advantages of DNA-directed cell binding include the ability to immobilize both adherent and non-adherent cells, to capture cells selectively from a mixed population, to tune the binding properties of the cells, and to reuse substrates prepared with widely available DNA printing technologies.
- 19 September 2007
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 7 (11) , 1442-1448
Self-assembled cellular microarrays patterned using DNA barcodes
The successful integration of living cells into synthetic devices requires precise control over cell patterning. Here we describe a versatile platform that can accomplish this goal through DNA hybridization. Living cells functionalized with exogenous cell-surface DNA strands bind to cognate sequences of DNA printed on glass slides. Attachment via these “cell-adhesion barcodes” is rapid and specific, with close-packed arrays of cells forming within minutes. The biophysical properties of the system are characterized, and the technique is used to form complex cellular patterns with single-cell line widths and self-assembled cellular microarrays. Key advantages of DNA-directed cell binding include the ability to immobilize both adherent and non-adherent cells, to capture cells selectively from a mixed population, to tune the binding properties of the cells, and to reuse substrates prepared with widely available DNA printing technologies.
- 22 August 2007
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Biogeosciences
- Vol. 112 (G4)
Organic amine biomarker detection in the Yungay region of the Atacama Desert with the Urey instrument
The Urey in situ organic compound analysis instrument, consisting of a subcritical water extractor (SCWE) and a portable microchip capillary electrophoresis instrument called the Mars Organic Analyzer (MOA), was field tested in the Atacama Desert, Chile, in June 2005. Soil samples from the most arid Yungay region were collected, biomarkers were extracted by the SCWE, and organic amine composition and amino acid chirality analysis was performed by the MOA. Samples collected from the top 1 cm of duracrust soil but shielded from the ambient environment by rocks were compared to the exposed duracrust. The shielded duracrust yielded amines and amino acids ranging from 50 to 100 ppb, while amino acid signals from the exposed duracrust were below blank levels. Samples from buried gypsum deposits located directly above a water flow channel contained amino acids ranging from 13 to 90 ppb. Chiral analysis revealed D/L ratios of 0.39 ± 0.08 and 0.34 ± 0.07 for alanine/serine and 0.78 ± 0.06 for aspartic acid, indicating significant racemization of biologically produced amino acids. On the basis of the D/L ratios, we estimate sample ages ranging from 103 to 105 years. These results demonstrate the successful field testing of the Urey instrument, as well as the detection of biomarkers from past terrestrial life in one of the most arid and Mars‐like regions on Earth.
- 22 August 2007
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Biogeosciences
- Vol. 112 (G4)
Organic amine biomarker detection in the Yungay region of the Atacama Desert with the Urey instrument
The Urey in situ organic compound analysis instrument, consisting of a subcritical water extractor (SCWE) and a portable microchip capillary electrophoresis instrument called the Mars Organic Analyzer (MOA), was field tested in the Atacama Desert, Chile, in June 2005. Soil samples from the most arid Yungay region were collected, biomarkers were extracted by the SCWE, and organic amine composition and amino acid chirality analysis was performed by the MOA. Samples collected from the top 1 cm of duracrust soil but shielded from the ambient environment by rocks were compared to the exposed duracrust. The shielded duracrust yielded amines and amino acids ranging from 50 to 100 ppb, while amino acid signals from the exposed duracrust were below blank levels. Samples from buried gypsum deposits located directly above a water flow channel contained amino acids ranging from 13 to 90 ppb. Chiral analysis revealed D/L ratios of 0.39 ± 0.08 and 0.34 ± 0.07 for alanine/serine and 0.78 ± 0.06 for aspartic acid, indicating significant racemization of biologically produced amino acids. On the basis of the D/L ratios, we estimate sample ages ranging from 103 to 105 years. These results demonstrate the successful field testing of the Urey instrument, as well as the detection of biomarkers from past terrestrial life in one of the most arid and Mars‐like regions on Earth.