Brett I. Cohen
Research Subjects
Brett I. Cohen has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
A. S. Deutsch
Essential Dental Laboratories, South Hackensack, New Jersey, and Department of Restorative and Prosthetic Sciences NYU College of Dentistry, New York, U.S.A. E‐mail
2 shared publicationsB. L. Musikant
Essential Dental Laboratories, South Hackensack, New Jersey, and Department of Restorative and Prosthetic Sciences NYU College of Dentistry, New York, U.S.A. E‐mail
2 shared publicationsBapanaiah Penugonda
2 shared publicationsA S Deutsch
1 shared publicationAllan Schulman
1 shared publicationB L Musikant
1 shared publication
Latest Publications
- 1 July 2002
- Published by Elsevier in Medical Hypotheses
- Vol. 59 (1) , 115-116
Use of a GABA-transaminase agonist for treatment of infantile autism
- 1 July 2002
- Published by Elsevier in Medical Hypotheses
- Vol. 59 (1) , 115-116
Use of a GABA-transaminase agonist for treatment of infantile autism
- 31 December 2001
- Published by Elsevier in Medical Hypotheses
- Vol. 57 (6) , 673-674
GABA-transaminase, the liver and infantile autism
- 31 December 2001
- Published by Elsevier in Medical Hypotheses
- Vol. 57 (6) , 673-674
GABA-transaminase, the liver and infantile autism
- 1 April 2001
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 85 (4) , 409-412
Use of inductively coupled plasma-emission spectroscopy and mercury vapor analyses to evaluate elemental release from a high-copper dental amalgam: A pilot study
- 1 April 2001
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 85 (4) , 409-412
Use of inductively coupled plasma-emission spectroscopy and mercury vapor analyses to evaluate elemental release from a high-copper dental amalgam: A pilot study
- 1 July 2000
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 84 (1) , 38-42
Torsional resistance of crowns cemented to composite cores involving three stainless steel endodontic post designs
- 1 July 2000
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 84 (1) , 38-42
Torsional resistance of crowns cemented to composite cores involving three stainless steel endodontic post designs
- 1 June 2000
- Vol. 83 (6) , 624-8
Retention of a core material supported by three post head designs.
There are few studies on the retention of core build-up materials to prefabricated post head designs, especially for a new ceramic post design. This in vitro study compared the retention of 2 types of core build-up materials (Ti-Core titanium-reinforced composite and a GC Miracle Mix silver-reinforced glass ionomer) supported by 3 post head designs (Flexi-Post, AccessPost, and Cerapost dowel). For all test groups, heads of the posts were placed into the core material at a 90-degree angle to the surface. Test specimens (unloaded) were then placed into a special jig and retention test was performed using an 810 MTS testing machine. This study consisted of 6 groups with 10 specimens per group. A 3 x 2 factorial design was used to test for statistical significance and results were considered significant when P <.05. Results of the retention test were as follows: group 1, Flexi-Post/Ti-Core 220.0 lb (982.1 N), group 2, AccessPost/Ti-Core 212.7 lb (949.6 N), group 3, Cerapost/Ti-Core 41. 8 lb (186.6 N), group 4, Flexi-Post/Miracle Mix 43.4 lb (193.8 N), group 5, AccessPost/Miracle Mix 61.6 lb (275 N), and group 6, Cerapost/Miracle Mix 7.5 lb (33.5 N). Results of the ANOVA revealed a highly significant difference between posts and cores (P <.0001). Post head designs of the stainless steel AccessPost and Flexi-Post dowels offers greater retention then the smooth ceramic head design of the Cerapost dowel. In addition, the composite core material (Ti-Core) offers greater retentive strength values than the glass ionomer material (Miracle Mix).
- 1 June 2000
- Vol. 83 (6) , 624-8
Retention of a core material supported by three post head designs.
There are few studies on the retention of core build-up materials to prefabricated post head designs, especially for a new ceramic post design. This in vitro study compared the retention of 2 types of core build-up materials (Ti-Core titanium-reinforced composite and a GC Miracle Mix silver-reinforced glass ionomer) supported by 3 post head designs (Flexi-Post, AccessPost, and Cerapost dowel). For all test groups, heads of the posts were placed into the core material at a 90-degree angle to the surface. Test specimens (unloaded) were then placed into a special jig and retention test was performed using an 810 MTS testing machine. This study consisted of 6 groups with 10 specimens per group. A 3 x 2 factorial design was used to test for statistical significance and results were considered significant when P <.05. Results of the retention test were as follows: group 1, Flexi-Post/Ti-Core 220.0 lb (982.1 N), group 2, AccessPost/Ti-Core 212.7 lb (949.6 N), group 3, Cerapost/Ti-Core 41. 8 lb (186.6 N), group 4, Flexi-Post/Miracle Mix 43.4 lb (193.8 N), group 5, AccessPost/Miracle Mix 61.6 lb (275 N), and group 6, Cerapost/Miracle Mix 7.5 lb (33.5 N). Results of the ANOVA revealed a highly significant difference between posts and cores (P <.0001). Post head designs of the stainless steel AccessPost and Flexi-Post dowels offers greater retention then the smooth ceramic head design of the Cerapost dowel. In addition, the composite core material (Ti-Core) offers greater retentive strength values than the glass ionomer material (Miracle Mix).
- 1 January 2000
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 27 (1) , 83-92
Pilot study of the cyclic fatigue characteristics of five endodontic posts with four core materials
This pilot study concerned the cyclic fatigue of five different endodontic post systems (AccessPost®, Flexi‐Flange®, Flexi‐Post®, ParaPost®, and Vlock®) with four different core materials (Tytin® Silver amalgam, Ti‐Core®, Ketac‐Silver® and G‐C Miracle Mix®). In vitro cyclic fatigue was performed using a fatigue machine that simulates masticatory fatigue forces. An instantaneous force of 5 lb was applied to each post and core combination for a test configuration of 4 000 000 repetitions or until failure occurred. The type of failure and number of repetitions at failure was recorded for each sample tested. Two‐way anova was used to compare groups. All posts/core samples with Ti‐Core and Tytin Silver amalgam completed the test configuration of 4 000 000 cycles without failures. All posts/core samples with Ketac‐Silver failed before the 4 000 000 test cycle configuration, all as a result of core failures. All posts/core samples with G‐C Miracle Mix failed in a similar way. The Newman–Keuls multiple comparison test illustrated that Ti‐Core and Tytin Silver amalgam were similar to each other and were superior to both G‐C Miracle Mix and Ketac‐Silver. Similar fatigue test results are found in the literature.
- 1 January 2000
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 27 (1) , 83-92
Pilot study of the cyclic fatigue characteristics of five endodontic posts with four core materials
This pilot study concerned the cyclic fatigue of five different endodontic post systems (AccessPost®, Flexi‐Flange®, Flexi‐Post®, ParaPost®, and Vlock®) with four different core materials (Tytin® Silver amalgam, Ti‐Core®, Ketac‐Silver® and G‐C Miracle Mix®). In vitro cyclic fatigue was performed using a fatigue machine that simulates masticatory fatigue forces. An instantaneous force of 5 lb was applied to each post and core combination for a test configuration of 4 000 000 repetitions or until failure occurred. The type of failure and number of repetitions at failure was recorded for each sample tested. Two‐way anova was used to compare groups. All posts/core samples with Ti‐Core and Tytin Silver amalgam completed the test configuration of 4 000 000 cycles without failures. All posts/core samples with Ketac‐Silver failed before the 4 000 000 test cycle configuration, all as a result of core failures. All posts/core samples with G‐C Miracle Mix failed in a similar way. The Newman–Keuls multiple comparison test illustrated that Ti‐Core and Tytin Silver amalgam were similar to each other and were superior to both G‐C Miracle Mix and Ketac‐Silver. Similar fatigue test results are found in the literature.
- 1 June 1999
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 26 (6) , 488-494
Comparison of the retentive and photoelastic properties of two prefabricated endodontic post systems
This in vitro study compared the retention and photoelastic stress patterns from two loading conditions, vertical (133·2 N, 30 pounds) and oblique at a 26° angle (133·2 N, 30 pounds) for two prefabricated post systems. The post studied were: (1) Flexi‐Post® (a split‐shank threaded post) and (2) C‐Post® (a carbon fibre bound in an epoxy resin, passive double taper tier post). Two groups with 10 specimens per group were subjected to retentive forces with a universal testing machine (MTS 810 Material Testing Machine). In addition, two photoelastic test blocks were prepared with simulated root canals for each post studied. After cementation the photoelastic blocks were photographed before vertical and oblique loading and after loading. One‐way analysis of variance ( anova) for retention data revealed a highly significant difference (P≪0·0001) between groups. The Flexi‐Post® had a statistically higher mean retention force of 1180·6 N (265·9 pounds), while the C‐Post® had a mean of 171·8 N (38·7 pounds). Photoelastic analysis indicated minimal stresses for both the Flexi‐Post® and C‐Post® in the unloaded state. The C‐Post® showed asymmetrical apically stress patterns, while loaded in both states. The multi‐tiered system of the Flexi‐Post® clearly distributes stress symmetrically, while the C‐Post® distributes stresses asymmetrically. The symmetric, even stresses and statistically higher retentive strength for Flexi‐Post® are more favourable than the asymmetric, uneven stresses and relatively low retentive strength for the C‐Post®.
- 1 June 1999
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 26 (6) , 488-494
Comparison of the retentive and photoelastic properties of two prefabricated endodontic post systems
This in vitro study compared the retention and photoelastic stress patterns from two loading conditions, vertical (133·2 N, 30 pounds) and oblique at a 26° angle (133·2 N, 30 pounds) for two prefabricated post systems. The post studied were: (1) Flexi‐Post® (a split‐shank threaded post) and (2) C‐Post® (a carbon fibre bound in an epoxy resin, passive double taper tier post). Two groups with 10 specimens per group were subjected to retentive forces with a universal testing machine (MTS 810 Material Testing Machine). In addition, two photoelastic test blocks were prepared with simulated root canals for each post studied. After cementation the photoelastic blocks were photographed before vertical and oblique loading and after loading. One‐way analysis of variance ( anova) for retention data revealed a highly significant difference (P≪0·0001) between groups. The Flexi‐Post® had a statistically higher mean retention force of 1180·6 N (265·9 pounds), while the C‐Post® had a mean of 171·8 N (38·7 pounds). Photoelastic analysis indicated minimal stresses for both the Flexi‐Post® and C‐Post® in the unloaded state. The C‐Post® showed asymmetrical apically stress patterns, while loaded in both states. The multi‐tiered system of the Flexi‐Post® clearly distributes stress symmetrically, while the C‐Post® distributes stresses asymmetrically. The symmetric, even stresses and statistically higher retentive strength for Flexi‐Post® are more favourable than the asymmetric, uneven stresses and relatively low retentive strength for the C‐Post®.