Feng-Bo Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Feng-Bo Wu has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Shi-Quan Han
4 shared publicationsYou-Feng He
4 shared publicationsChao Zhang
2 shared publicationsTao Xu
1 shared publication
Latest Publications
- 1 March 2003
- Published by Elsevier in Analytical Biochemistry
- Vol. 314 (1) , 87-96
Sensitive time-resolved fluoroimmunoassay for simultaneous detection of serum thyroid-stimulating hormone and total thyroxin with Eu and Sm as labels
- 1 March 2003
- Published by Elsevier in Analytical Biochemistry
- Vol. 314 (1) , 87-96
Sensitive time-resolved fluoroimmunoassay for simultaneous detection of serum thyroid-stimulating hormone and total thyroxin with Eu and Sm as labels
- 1 December 2002
- Published by Elsevier in Analytical Biochemistry
- Vol. 311 (1) , 57-67
A new europium β-diketone chelate for ultrasensitive time-resolved fluorescence immunoassays
- 1 December 2002
- Published by Elsevier in Analytical Biochemistry
- Vol. 311 (1) , 57-67
A new europium β-diketone chelate for ultrasensitive time-resolved fluorescence immunoassays
- 22 October 2002
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 74 (22) , 5882-5889
Synthesis of a Highly Fluorescent β-Diketone−Europium Chelate and Its Utility in Time-Resolved Fluoroimmunoassay of Serum Total Thyroxine
A new highly fluorescent β-diketone−europium chelate was synthesized and employed as a tracer to develop a time-resolved fluoroimmunoassay (TRFIA) for detection of serum total thyroxine (T4). The tetradentate β-diketone chelator, 1,10-bis(thiophene-2‘-yl)-4,4,5,5,6,6,7,7-octafluorodecane-1,3,8,10-tetraone (BTOT), was structurally composed of two units of thenoyltrifluoroacetone (TTA) derivatives but expressed fluorescence that was greatly enhanced, as compared to the original TTA molecules, in the presence of excess amount of Eu3+. The luminescence properties of the europium chelate of BTOT were studied in aqueous solution. Chlorosulfonylation of BTOT afforded 1,10-bis(5‘-chlorosulfo-thiophene-2‘-yl)-4,4,5,5,6,6,7,7-octafluorodecane-1,3,8,10-tetraone (BCTOT), which could be coupled to proteins (i.e., streptavidin or the BSA−T4 conjugate) and used as a tracer for TRFIA. Although the BCTOT−Eu complex could be detected at a very low level (∼1.07 × 10-12 mol/L) in buffered aqueous solution (50 mmol/L Tris−HCl; pH, 8.0), the application of the chelate label in direct serum T4 TRFIA experienced a problem of matrix interference, which was probably caused by some unknown chelating components in the samples as a result of the fact that the fluorescence of the BCTOT−Eu chelate was prone to quenching or enhancement by some chelating reagents. To remove this problem, an indirect serum T4 TRFIA was proposed with the use of BCTOT−Eu-labeled streptavidin (SA) as signal generation reagent. The concentrations of T4 in 27 human serums were determined by indirect T4 TRFIA, and the assay results correlated well with those obtained by commercial Corning-CLIA (r = 0.955) and Wallac-DELFIA (r = 0.965).
- 22 October 2002
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 74 (22) , 5882-5889
Synthesis of a Highly Fluorescent β-Diketone−Europium Chelate and Its Utility in Time-Resolved Fluoroimmunoassay of Serum Total Thyroxine
A new highly fluorescent β-diketone−europium chelate was synthesized and employed as a tracer to develop a time-resolved fluoroimmunoassay (TRFIA) for detection of serum total thyroxine (T4). The tetradentate β-diketone chelator, 1,10-bis(thiophene-2‘-yl)-4,4,5,5,6,6,7,7-octafluorodecane-1,3,8,10-tetraone (BTOT), was structurally composed of two units of thenoyltrifluoroacetone (TTA) derivatives but expressed fluorescence that was greatly enhanced, as compared to the original TTA molecules, in the presence of excess amount of Eu3+. The luminescence properties of the europium chelate of BTOT were studied in aqueous solution. Chlorosulfonylation of BTOT afforded 1,10-bis(5‘-chlorosulfo-thiophene-2‘-yl)-4,4,5,5,6,6,7,7-octafluorodecane-1,3,8,10-tetraone (BCTOT), which could be coupled to proteins (i.e., streptavidin or the BSA−T4 conjugate) and used as a tracer for TRFIA. Although the BCTOT−Eu complex could be detected at a very low level (∼1.07 × 10-12 mol/L) in buffered aqueous solution (50 mmol/L Tris−HCl; pH, 8.0), the application of the chelate label in direct serum T4 TRFIA experienced a problem of matrix interference, which was probably caused by some unknown chelating components in the samples as a result of the fact that the fluorescence of the BCTOT−Eu chelate was prone to quenching or enhancement by some chelating reagents. To remove this problem, an indirect serum T4 TRFIA was proposed with the use of BCTOT−Eu-labeled streptavidin (SA) as signal generation reagent. The concentrations of T4 in 27 human serums were determined by indirect T4 TRFIA, and the assay results correlated well with those obtained by commercial Corning-CLIA (r = 0.955) and Wallac-DELFIA (r = 0.965).
- 15 May 2002
- Published by Taylor & Francis in Journal of Immunoassay and Immunochemistry
- Vol. 23 (2) , 191-210
TIME-RESOLVED IMMUNOFLUOROMETRY OF SERUM HTSH WITH ENHANCED SENSITIVITY
Sensitive TSH immunoassays offer a clear advance in discriminating the TSH concentrations in serum between hyperthyroid and euthyroid individuals; they have been proposed as the best single screening test for thyroid disorders. We have developed a highly sensitive serum TSH TRFIA based on DELFIA technology. Three monoclonal antibodies (McAbs) directed against different epitopes of the TSH molecule were involved in this assay, of which, one McAb was used to coat clear microwells, and the other two were biotinylated for signal generation after being bound by the europium labeled streptavidin. The europium label captured on the well surface was quantified by a routine dissociation-enhancement procedure. The fluorescence intensity was directly proportional to the serum hTSH concentration. The assay required two steps and could be completed within 5 h. The analytical sensitivity reached 0.002 mIU/L with a sample volume of 100 µL, the function sensitivity was 0.017 mIU/L. Measurements by the present me...
- 15 May 2002
- Published by Taylor & Francis in Journal of Immunoassay and Immunochemistry
- Vol. 23 (2) , 191-210
TIME-RESOLVED IMMUNOFLUOROMETRY OF SERUM HTSH WITH ENHANCED SENSITIVITY
Sensitive TSH immunoassays offer a clear advance in discriminating the TSH concentrations in serum between hyperthyroid and euthyroid individuals; they have been proposed as the best single screening test for thyroid disorders. We have developed a highly sensitive serum TSH TRFIA based on DELFIA technology. Three monoclonal antibodies (McAbs) directed against different epitopes of the TSH molecule were involved in this assay, of which, one McAb was used to coat clear microwells, and the other two were biotinylated for signal generation after being bound by the europium labeled streptavidin. The europium label captured on the well surface was quantified by a routine dissociation-enhancement procedure. The fluorescence intensity was directly proportional to the serum hTSH concentration. The assay required two steps and could be completed within 5 h. The analytical sensitivity reached 0.002 mIU/L with a sample volume of 100 µL, the function sensitivity was 0.017 mIU/L. Measurements by the present me...
- 12 June 2001
- Published by Elsevier in Clinica Chimica Acta
- Vol. 308 (1-2) , 117-126
Matrix interference in serum total thyroxin (T4) time-resolved fluorescence immunoassay (TRFIA) and its elimination with the use of streptavidin–biotin separation technique
- 12 June 2001
- Published by Elsevier in Clinica Chimica Acta
- Vol. 308 (1-2) , 117-126
Matrix interference in serum total thyroxin (T4) time-resolved fluorescence immunoassay (TRFIA) and its elimination with the use of streptavidin–biotin separation technique