Chinnarat Bua-Ngam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chinnarat Bua-Ngam has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- B. Wedsart
Vascular and body interventional radiology unit, department of diagnostic and therapeutic radiology, faculty of medicine, Ramathibodi hospital, Mahidol university, 270, Rama VI Road, 10400 Ratchathewi, Bangkok, Thailand
1 shared publication - Hathaichanok Choochuay
Ramathibodi Hospital, Mahidol University
1 shared publication Ittikorn Spanuchart
Division of Nephrology, Department of Internal Medicine, University of Michigan, Ann Arbor, USA
1 shared publication- J. Norasetsingh
Vascular and body interventional radiology unit, department of diagnostic and therapeutic radiology, faculty of medicine, Ramathibodi hospital, Mahidol university, 270, Rama VI Road, 10400 Ratchathewi, Bangkok, Thailand
1 shared publication - J. Tapaneeyakorn
Vascular and body interventional radiology unit, department of diagnostic and therapeutic radiology, faculty of medicine, Ramathibodi hospital, Mahidol university, 270, Rama VI Road, 10400 Ratchathewi, Bangkok, Thailand
1 shared publication Kaewpitcha Pichitpichatkul
Division of Body Interventional Radiology, Department of Diagnostic and Therapeutic Radiology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand
1 shared publication
Latest Publications
- Open Access
- 29 July 2025
- Published by Oxford University Press (OUP) in Journal Of Nephrology
- Vol. 38 (7) , 1947-1955
Tangential biopsy angle and needle depth for adequacy and safety outcomes in ultrasound-guided native kidney biopsy—a single-center experience in a high-risk population
Background: Kidney biopsy is crucial for diagnosing kidney diseases but involves risks, notably bleeding, which must be balanced with diagnostic precision. This study examines the effect of the biopsy needle’s cortical tangential angle and depth on specimen adequacy and safety outcomes. Methods: This single-center, retrospective study reviewed electronic medical records from kidney biopsies performed between January 1, 2016 and December 31, 2020. Included were patients undergoing real-time ultrasound-guided percutaneous kidney biopsies. Exclusion criteria were pediatric patients, renal mass or transplant biopsies, and cases with incomplete records. Primary variables included biopsy needle cortical tangential angle and depth. Outcomes were tissue adequacy and safety, with complications assessed within 24 h. Results: Out of 443 biopsies performed, 124 met the inclusion criteria. Our patient population had a mean BMI of 27.17 kg/m 2 , which met the criteria for obesity based on BMI standards for Asians, and they also had relatively small kidneys (< 9 cm) with parenchymal thinning. Biopsies at angles of 30°–60° yielded more glomeruli (12 vs. 5, p < 0.001) and had a higher pathologist-reported adequacy (82.67% vs. 59.18%, p = 0.004). Needle depth did not significantly impact adequacy. Major complications occurred in 12.90% of cases, with blood transfusions required in 8.06% and embolizations in 3.23%. All technical factors lost statistical significance after adjusting for confounders, except for increased echogenicity, which remained significant. Conclusions: The optimal needle angle for kidney biopsies is 30°–60° for the highest diagnostic yield compared to angles < 30° or > 60°. Our study did not reveal statistically significant differences in major complications between these angle ranges. This greater understanding of the relationship between biopsy angle, needle trajectory depth, and diagnostic and safety outcomes offers valuable insights for optimizing kidney biopsy procedures. Graphical
- 29 July 2025
- Published by Oxford University Press (OUP) in Journal Of Nephrology
- Vol. 38 (7) , 1947-1955
Open AccessTangential biopsy angle and needle depth for adequacy and safety outcomes in ultrasound-guided native kidney biopsy—a single-center experience in a high-risk population
Background: Kidney biopsy is crucial for diagnosing kidney diseases but involves risks, notably bleeding, which must be balanced with diagnostic precision. This study examines the effect of the biopsy needle’s cortical tangential angle and depth on specimen adequacy and safety outcomes. Methods: This single-center, retrospective study reviewed electronic medical records from kidney biopsies performed between January 1, 2016 and December 31, 2020. Included were patients undergoing real-time ultrasound-guided percutaneous kidney biopsies. Exclusion criteria were pediatric patients, renal mass or transplant biopsies, and cases with incomplete records. Primary variables included biopsy needle cortical tangential angle and depth. Outcomes were tissue adequacy and safety, with complications assessed within 24 h. Results: Out of 443 biopsies performed, 124 met the inclusion criteria. Our patient population had a mean BMI of 27.17 kg/m 2 , which met the criteria for obesity based on BMI standards for Asians, and they also had relatively small kidneys (< 9 cm) with parenchymal thinning. Biopsies at angles of 30°–60° yielded more glomeruli (12 vs. 5, p < 0.001) and had a higher pathologist-reported adequacy (82.67% vs. 59.18%, p = 0.004). Needle depth did not significantly impact adequacy. Major complications occurred in 12.90% of cases, with blood transfusions required in 8.06% and embolizations in 3.23%. All technical factors lost statistical significance after adjusting for confounders, except for increased echogenicity, which remained significant. Conclusions: The optimal needle angle for kidney biopsies is 30°–60° for the highest diagnostic yield compared to angles < 30° or > 60°. Our study did not reveal statistically significant differences in major complications between these angle ranges. This greater understanding of the relationship between biopsy angle, needle trajectory depth, and diagnostic and safety outcomes offers valuable insights for optimizing kidney biopsy procedures. Graphical
- Open Access
- 9 August 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (16) , 4666
Reduced Incidence of Pneumothorax and Chest Tube Placement following Transthoracic CT-Guided Lung Biopsy with Gelatin Sponge Torpedo Track Embolization: A Propensity Score–Matched Study
Objectives: To evaluate the effectiveness of track embolization using gelatin sponge torpedo in reducing the incidence of pneumothorax and chest tube placement after percutaneous CT-guided lung biopsy. Methods: A retrospective single-center analysis of percutaneous computed tomography (CT)-guided transthoracic lung biopsies was performed between 2017 and 2022. After excluding the patients who received an ultrasound-guided biopsy, combined lung biopsy with ablation, fiducial placement, unsuccessful procedure due to uncooperative patient, and age under 18 years, 884 patients’ clinical information was collected (667 without track embolization and 217 with track embolization). The incidence of early and late pneumothorax and chest tube placement were compared between the two groups. Propensity score matching (PSM) was applied to minimize selection bias. Univariable and multivariable analyses were performed to determine risk factors for pneumothorax. Results: After PSM, the baseline differences and all factors that could affect the incidence of pneumothorax were balanced between the track embolization group (217 patients) and the non-track embolization group (217 patients). The incidence rates of early pneumothorax (13.4% vs. 24.0% p = 0.005), late pneumothorax (11.0% vs. 18.0% p = 0.021), and chest tube placement (0.9% vs. 4.6% p = 0.036) were significantly decreased in the track embolization group. However, the success rate of tissue diagnosis yield and length of hospital stay were not significantly different between the two groups. In multivariate analysis, the risk of pneumothorax increased as the fissure was passed (OR = 3.719, p = 0.027). Conclusions: Using track embolization with a gelatin sponge torpedo significantly decreased the incidence of pneumothorax and chest tube placement following percutaneous CT-guided lung biopsy.
- 9 August 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (16) , 4666
Open AccessReduced Incidence of Pneumothorax and Chest Tube Placement following Transthoracic CT-Guided Lung Biopsy with Gelatin Sponge Torpedo Track Embolization: A Propensity Score–Matched Study
Objectives: To evaluate the effectiveness of track embolization using gelatin sponge torpedo in reducing the incidence of pneumothorax and chest tube placement after percutaneous CT-guided lung biopsy. Methods: A retrospective single-center analysis of percutaneous computed tomography (CT)-guided transthoracic lung biopsies was performed between 2017 and 2022. After excluding the patients who received an ultrasound-guided biopsy, combined lung biopsy with ablation, fiducial placement, unsuccessful procedure due to uncooperative patient, and age under 18 years, 884 patients’ clinical information was collected (667 without track embolization and 217 with track embolization). The incidence of early and late pneumothorax and chest tube placement were compared between the two groups. Propensity score matching (PSM) was applied to minimize selection bias. Univariable and multivariable analyses were performed to determine risk factors for pneumothorax. Results: After PSM, the baseline differences and all factors that could affect the incidence of pneumothorax were balanced between the track embolization group (217 patients) and the non-track embolization group (217 patients). The incidence rates of early pneumothorax (13.4% vs. 24.0% p = 0.005), late pneumothorax (11.0% vs. 18.0% p = 0.021), and chest tube placement (0.9% vs. 4.6% p = 0.036) were significantly decreased in the track embolization group. However, the success rate of tissue diagnosis yield and length of hospital stay were not significantly different between the two groups. In multivariate analysis, the risk of pneumothorax increased as the fissure was passed (OR = 3.719, p = 0.027). Conclusions: Using track embolization with a gelatin sponge torpedo significantly decreased the incidence of pneumothorax and chest tube placement following percutaneous CT-guided lung biopsy.
- 1 June 2017
- Published by Elsevier in Diagnostic and Interventional Imaging
- Vol. 98 (6) , 499-505
Efficacy of emergency transarterial embolization in acute lower gastrointestinal bleeding: A single-center experience
- 1 June 2017
- Published by Elsevier in Diagnostic and Interventional Imaging
- Vol. 98 (6) , 499-505
Efficacy of emergency transarterial embolization in acute lower gastrointestinal bleeding: A single-center experience
- 26 February 2015
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 33 (4) , 201-209
Visibility and variability of pleural fissures on normal digital chest radiographs of 1,000 healthy adults
To investigate the visibility and variability of pleural fissures on digital chest radiographs. Posteroanterior digital chest radiographs of 566 males and 434 females were retrospectively reviewed for the frequencies and/or appearances of various pleural fissures. The right only, left only and bilateral minor fissures were visible in 722 (72.2 %), 1 (0.1 %) and 7 (0.7 %) subjects, respectively. The right minor fissures were visible as more than one line in 219 (30.0 %) subjects, i.e., 2, 3 and 4 lines in 214 (29.3 %), 4 (0.5 %) and 1 (0.1 %), respectively. The 955 visible right minor fissures exhibited variable length (2/3, 22.1 %), alignment (medial higher 40.9 %; lateral higher 54.2 %; horizontal 4.8 %) and contour (convex upward 68.6 %; convex downward 2.7 %; flat 24.9 %; sigmoid 3.8 %). Superolateral major fissures were visualized in 14.8 % (right only 3.0 %; left only 9.0 %; bilateral 2.8 %), superomedial major fissures in 0.3 % (right 0.1 %; left 0.2 %), vertical fissures in 0.5 % (right 0.2 %; left 0.3 %), inferior accessory fissures in 5.4 % (right 4.8 %; left 0.6 %), right superior accessory fissures in 1.2 % and azygos fissures in 0.2 %. The right minor fissure was most frequently visible and exhibited variable appearances. Other pleural fissures were occasionally seen.
- 26 February 2015
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 33 (4) , 201-209
Visibility and variability of pleural fissures on normal digital chest radiographs of 1,000 healthy adults
To investigate the visibility and variability of pleural fissures on digital chest radiographs. Posteroanterior digital chest radiographs of 566 males and 434 females were retrospectively reviewed for the frequencies and/or appearances of various pleural fissures. The right only, left only and bilateral minor fissures were visible in 722 (72.2 %), 1 (0.1 %) and 7 (0.7 %) subjects, respectively. The right minor fissures were visible as more than one line in 219 (30.0 %) subjects, i.e., 2, 3 and 4 lines in 214 (29.3 %), 4 (0.5 %) and 1 (0.1 %), respectively. The 955 visible right minor fissures exhibited variable length (2/3, 22.1 %), alignment (medial higher 40.9 %; lateral higher 54.2 %; horizontal 4.8 %) and contour (convex upward 68.6 %; convex downward 2.7 %; flat 24.9 %; sigmoid 3.8 %). Superolateral major fissures were visualized in 14.8 % (right only 3.0 %; left only 9.0 %; bilateral 2.8 %), superomedial major fissures in 0.3 % (right 0.1 %; left 0.2 %), vertical fissures in 0.5 % (right 0.2 %; left 0.3 %), inferior accessory fissures in 5.4 % (right 4.8 %; left 0.6 %), right superior accessory fissures in 1.2 % and azygos fissures in 0.2 %. The right minor fissure was most frequently visible and exhibited variable appearances. Other pleural fissures were occasionally seen.