Chaowen Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chaowen Yang has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Balin Zhu
College of physics, Sichuan University, Chengdu 610065, China
1 shared publicationChaoyang Zhao
College of physics, Sichuan University, Chengdu 610065, China
1 shared publicationGeng Tian
Northwest Institute of Nuclear Technology
1 shared publicationHongcun Zhu
State Key Laboratory of Nuclear Physics and Technology, School of Physics, Peking University, Beijing 100871, China
1 shared publicationJ. F. Lu
School of Nuclear Science and Technology, Sichuan University
1 shared publicationJ. W. Miao
School of Nuclear Science and Technology, Sichuan University
1 shared publication
Latest Publications
- 1 December 2022
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 204
Proton beam secondary depth-dose calculation with a secondary propagation model
- 1 December 2022
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 204
Proton beam secondary depth-dose calculation with a secondary propagation model
- 10 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 68 (6) , 1309-1318
Design and Implementation of a Portable High-Performance Gamma-Ray Camera
With the growing number of facilities applying nuclear technology in China, a high-performance portable gamma-ray camera that uses well-developed gamma-ray imaging techniques is increasingly required. To fulfill that requirement, we have designed a camera using a self-supported mask, a CsI(Na) array coupled to a silicon photomultiplier (SiPM) rather than the traditional position-sensitive photomultiplier tube (PSPMT), and a highly integrated readout circuit. In addition, with the elimination of multi-Compton events in the crystal array based on a row/column readout circuit incorporated into the data processing method, the peak-to-valley ratio of the flood source map and the image quality quantified by the contrast-to-noise ratio index of 137Cs were improved significantly by 25.8% from 9.8 to 12.3 and 14.8% from 38.7 to 45.0, respectively.
- 10 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 68 (6) , 1309-1318
Design and Implementation of a Portable High-Performance Gamma-Ray Camera
With the growing number of facilities applying nuclear technology in China, a high-performance portable gamma-ray camera that uses well-developed gamma-ray imaging techniques is increasingly required. To fulfill that requirement, we have designed a camera using a self-supported mask, a CsI(Na) array coupled to a silicon photomultiplier (SiPM) rather than the traditional position-sensitive photomultiplier tube (PSPMT), and a highly integrated readout circuit. In addition, with the elimination of multi-Compton events in the crystal array based on a row/column readout circuit incorporated into the data processing method, the peak-to-valley ratio of the flood source map and the image quality quantified by the contrast-to-noise ratio index of 137Cs were improved significantly by 25.8% from 9.8 to 12.3 and 14.8% from 38.7 to 45.0, respectively.
- 27 February 2019
- Published by Wiley in X-Ray Spectrometry
- Vol. 48 (3) , 232-241
Elemental characterization and source identification of the near‐road PM 2.5 using EDXRF in Chengdu, China
To characterize the elemental composition and source apportionment of aerosols in roadside area, particulate matters with aerodynamic diameter less than 2.5 μm (PM 2.5 ) were collected in close proximity to a road from September 2017 to February 2018 in downtown Chengdu, China. An energy‐dispersive X‐ray fluorescence spectrometer was used to quantify elemental constituents (Al, Si, S, K, Mn, Fe, Ni, Cu, Zn, As, and Pb) of PM 2.5 and was calibrated by in‐house standards instead of commercial standards. The constructed calibration curves exhibited good linearity with all correlation coefficients greater than 0.98. The proposed calibration method proved to be reliable for the subsequent elemental analyses due to the satisfactory performance of u ‐score and precision that were validated by the certified reference materials (#2783). The results revealed that average PM 2.5 concentrations of 92.2 ± 45.6 and 113.2 ± 60.3 μg/m 3 were respectively observed in autumn and in winter. The major trace elements identified were K, S, and Fe and the minor contributions were from Cu and As. Most crustal elements showed decline in winter except for K, and most anthropogenic elements showed increase in winter except for Ni. Using rotation factor analysis and cluster analysis based on the elemental dataset, four potential sources were identified: road dust, vehicular emissions, coal and biomass burning, and industrial emissions. This research will provide a better understanding of traffic‐related PM 2.5 composition, and this can be used in the mitigation and prevention programs.
- 27 February 2019
- Published by Wiley in X-Ray Spectrometry
- Vol. 48 (3) , 232-241
Elemental characterization and source identification of the near‐road PM 2.5 using EDXRF in Chengdu, China
To characterize the elemental composition and source apportionment of aerosols in roadside area, particulate matters with aerodynamic diameter less than 2.5 μm (PM 2.5 ) were collected in close proximity to a road from September 2017 to February 2018 in downtown Chengdu, China. An energy‐dispersive X‐ray fluorescence spectrometer was used to quantify elemental constituents (Al, Si, S, K, Mn, Fe, Ni, Cu, Zn, As, and Pb) of PM 2.5 and was calibrated by in‐house standards instead of commercial standards. The constructed calibration curves exhibited good linearity with all correlation coefficients greater than 0.98. The proposed calibration method proved to be reliable for the subsequent elemental analyses due to the satisfactory performance of u ‐score and precision that were validated by the certified reference materials (#2783). The results revealed that average PM 2.5 concentrations of 92.2 ± 45.6 and 113.2 ± 60.3 μg/m 3 were respectively observed in autumn and in winter. The major trace elements identified were K, S, and Fe and the minor contributions were from Cu and As. Most crustal elements showed decline in winter except for K, and most anthropogenic elements showed increase in winter except for Ni. Using rotation factor analysis and cluster analysis based on the elemental dataset, four potential sources were identified: road dust, vehicular emissions, coal and biomass burning, and industrial emissions. This research will provide a better understanding of traffic‐related PM 2.5 composition, and this can be used in the mitigation and prevention programs.
- 1 April 2018
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 29 (4) , 59
Geant4 analysis and optimization of a double crystal phoswich detector for beta-gamma coincidence detection
- 1 April 2018
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 29 (4) , 59
Geant4 analysis and optimization of a double crystal phoswich detector for beta-gamma coincidence detection
- 28 November 2011
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 150 (3) , 391-397
Natural and artificial radionuclide measurements and radioactivity assessment of soil samples in eastern Sichuan province (China)
The activity concentrations of natural and artificial radionuclides were measured in the eastern region of Sichuan province (China). One hundred and ninety-three soil samples from this region were collected and analysed by high-purity germanium gamma spectrometry. The measured results show that the average radioactivity concentrations of 226Ra, 232Th, 40K and 137Cs in the soil samples are 26, 49, 440 and 6 Bq kg−1, respectively. The calculated average radium equivalent activity is 130 Bq kg−1, which is less than the recommended limit of 370 Bq kg−1. The absorbed dose rate and annual effective dose are 60 nGy h−1 and 74 µSv, respectively. This is the first time the absorbed dose rate in the east region of Sichuan has been mapped. Overall, the environmental radiation background is greater in the southern part of the area studied than in the northern.
- 28 November 2011
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 150 (3) , 391-397
Natural and artificial radionuclide measurements and radioactivity assessment of soil samples in eastern Sichuan province (China)
The activity concentrations of natural and artificial radionuclides were measured in the eastern region of Sichuan province (China). One hundred and ninety-three soil samples from this region were collected and analysed by high-purity germanium gamma spectrometry. The measured results show that the average radioactivity concentrations of 226Ra, 232Th, 40K and 137Cs in the soil samples are 26, 49, 440 and 6 Bq kg−1, respectively. The calculated average radium equivalent activity is 130 Bq kg−1, which is less than the recommended limit of 370 Bq kg−1. The absorbed dose rate and annual effective dose are 60 nGy h−1 and 74 µSv, respectively. This is the first time the absorbed dose rate in the east region of Sichuan has been mapped. Overall, the environmental radiation background is greater in the southern part of the area studied than in the northern.
- 22 December 2009
- Published by Springer Nature in The European Physical Journal D
- Vol. 56 (3) , 347-352
The spatial distribution of argon clusters in gas jet
- 22 December 2009
- Published by Springer Nature in The European Physical Journal D
- Vol. 56 (3) , 347-352
The spatial distribution of argon clusters in gas jet