HGHongyan Guo

Hongyan Guo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hongyan Guo has a total of 33 co-authors. Here are the top co-authors by number of shared publications:

  • Rujing Wang

    Institute of Intelligent Machines, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China

    3 shared publications
  • Xiangyu Chen

    Institute of Intelligent Machines, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China

    3 shared publications
  • Junqing Zhang

    Institute of Intelligent Machines, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China

    2 shared publications
  • Aiwu Zhao

    Institute of Solid State Physics, Hefei Institutes of Physical Science

    1 shared publication
  • Bin Wang

    College of Chinese Medicine, School of Pharmacy, Key Laboratory of Xin'an Medicine of the Ministry of Education, Anhui University of Chinese Medicine, Hefei, 230038, PR China; Functional Activity and Resource Utilization on Edible and Medicinal Fungi Joint Laboratory of Anhui Province, Anhui University of Chinese Medicine, Hefei, 230038, PR China

    1 shared publication
  • Biquan Zhu

    School of Electrical and Information Engineering, Anhui University of Science and Technology, Huainan 232001, China

    1 shared publication

Latest Publications

  • Open Access

    Metal Halide-Based Microelectrode Sensors for Accurate Determination of Soil Moisture

    by Yan Hong, Biquan Zhu, Jingming Su, Qiao Cao, Junjie Song, Xiaoyu Zhang, Rongtao Yang, Dapeng Wang, Hongyan Guo, Rujing Wang, et al.

    Soil moisture monitoring is critical to agricultural production and water resource management, yet existing sensors often exhibit limitations in accuracy, cost-effectiveness, and long-term stability. This study aimed to develop a high-performance capacitive soil moisture sensor to address these issues. We selected eco-friendly lead-free K2CuBr3 as the hygroscopic material and optimized the interdigital electrode (IE) structure via theoretical analysis and finite element simulation. The sensors were fabricated using micro-electro-mechanical system (MEMS) technology, and their performance was systematically evaluated with real soil samples. The results demonstrated that K2CuBr3 substantially enhanced the sensor sensitivity. The optimal sensor exhibited a measurement error of approximately 5% over the soil moisture range of 0–42.5%, a relative standard deviation (RSD) of less than 2%, and good stability. This low-cost, lead-free MEMS capacitive sensor, based on K2CuBr3, offers high accuracy and excellent stability. It resolves key drawbacks of traditional sensors and offers a reliable solution for in situ real-time soil moisture monitoring, with broad prospects in smart agriculture.


  • Open Access

    A Novel Method for the Pre-Column Derivatization of Saccharides from Polygonatum cyrtonema Hua. by Integrating Lambert–Beer Law and Response Surface Methodology

    by Hui Liu, Yuanyuan Zhao, Leijing Chen, Jiao Du, Hongyan Guo, Bin Wang

    Traditional Chinese medicine (TCM) safety and effectiveness can be ensured by establishing a suitable quality assessment system. This work aims to develop a pre-column derivatization HPLC method for Polygonatum cyrtonema Hua. quality control. In this study, 1-(4′-cyanophenyl)-3-methyl-5-pyrazolone (CPMP) was synthesized and reacted with monosaccharides derived from P. cyrtonema polysaccharides (PCPs), followed by HPLC separation. According to the Lambert–Beer law, CPMP has the highest molar extinction coefficient of all synthetic chemosensors. A satisfactory separation effect was obtained under a detection wavelength of 278 nm using a carbon-8 column and gradient elution over 14 min, with a flow rate of 1 mL per minute. Glucose (Glc), galactose (Gal), and mannose (Man) make up the majority of the monosaccharide components in PCPs, and their molar ratios are 1.73:0.58:1. The confirmed HPLC method has outstanding precision and accuracy, establishing a quality control method for PCPs. Additionally, the CPMP showed a visual improvement from colorless to orange after the detection of reducing sugars, allowing for further visual analysis.


  • Open Access

    Partition Management of Soil Nutrients Based on Capacitive Coupled Contactless Conductivity Detection

    by Yuanyuan Wei, Rujing Wang, Junqing Zhang, Hongyan Guo, Xiangyu Chen

    A method based on capacitively coupled contactless conductivity detection (C4D), which has been proven effective for the rapid detection of available soil potassium content, was firstly proposed to apply to soil nutrient detection. By combining a detection signal spectrum analysis, geographic information system (GIS) data, and a cluster analysis, a soil nutrient management system to match the detection device was developed. This system included six modules: soil sample information management, electrophoresis analysis, quantitative calculation, nutrient result viewing, cluster analysis, and nutrient distribution map generation. The soil samples, which were collected from an experimental field in Xuchang City of Henan Province, were analyzed using the C4D and flame photometer methods. The results showed that the detection results for the soil samples obtained via the two methods were in good agreement. C4D technology was feasible for the detection of the soil available nutrients and had the advantages of a high timeliness, low sample volume, and low pollution. The soil nutrient management system adopted the hierarchical clustering method to classify the grid cells of the experimental field according to the nutrient detection results. A soil nutrient distribution map displayed the spatial difference in nutrients. This paper provides a systematic solution for soil nutrient zone management that includes nutrient detection, signal analysis, data management for the nutrient zone, and field nutrient distribution map generation to support decision making in variable fertilization.


  • Open Access

    Development of On-Site Rapid Detection Device for Soil Macronutrients Based on Capillary Electrophoresis and Capacitively Coupled Contactless Conductivity Detection (C4D) Method

    by Junqing Zhang, Rujing Wang, Zhou Jin, Hongyan Guo, Yi Liu, Yongjia Chang, Jiangning Chen, Mengya Li, Xiangyu Chen

    The acquisition of nutrient data on a precise scale has played a vital role in nutrient management processes for soils. However, the lack of rapid precise and multi-index detection techniques for soil macronutrient contents hinders both rational fertilization and cost reduction. In this paper, a rapid detection method and device were devised, combining capillary electrophoresis (CE) and capacitively coupled contactless conductivity detection (C4D), and presented to detect macronutrient contents of soil. The device consisted of a capillary channel, C4D detector, high-voltage system, etc. It separated macronutrient ions using capillary electrophoresis and then measured the ion concentration based on the C4D principle. Lime concretion black soil samples from a complete field were collected and detected. NO3−, NH4+, H2PO4− and K+ in sample solutions could be detected in 5 min with relative standard deviations (RSDs) from 1.0 to 7.51%. The injection voltage was set to 10 kV for 5 s, and the separation voltage was set to 14 kV. This demonstrated the excellent performance of the C4D device on the detection of soil macronutrients, which could help to guide fertilization operations more effectively.