Chengjian Xiao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chengjian Xiao has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
- Heyi Wang
Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621900, China
3 shared publications Jiamao Li
China Acad Engn Phys, Inst Nucl Phys & Chem, Mianyang 621900, Sichuan, Peoples R China
3 shared publications- Jiamao Li
Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621900, China
3 shared publications - Tao Gao
Sichuan University
3 shared publications Xiaojun Chen
China Acad Engn Phys, Inst Nucl Phys & Chem, Mianyang 621900, Sichuan, Peoples R China
3 shared publicationsHeyi Wang
Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621900, China
2 shared publications
Latest Publications
- Open Access
Optimization of Liquid Phase Catalytic Exchange Process for Hydrogen Isotope Separation Using Orthogonal Experiment Design
The Liquid Phase Catalytic Exchange (LPCE) process plays a pivotal role in the separation of hydrogen isotopes, particularly in applications such as tritium removal in heavy water reactors. Effective separation is crucial for maintaining reactor safety and efficiency. In this study, the optimal operating conditions for the LPCE process were determined through orthogonal experiments and validated in different hydrogen isotope systems. The experiments investigated key operational parameters, including the filling ratio of catalyst to packing (FR), operating temperature (T), superficial gas velocity (V), and gas-to-liquid flow rate ratio (λ), using a robust L16 orthogonal experiment design. The results indicated that V and FR had the most significant effects on the height equivalent to a theoretical plate (HETP), while λ exhibited the greatest impact on dedeuterization efficiency (DE). The optimal conditions obtained were V = 0.1 m/s, FR = 1:2, T = 70 °C, and λ = 2.5. Furthermore, the reproducibility of the optimal conditions was verified in LPCE columns with varying diameters (1.5 cm, 2.5 cm, 4.5 cm). Additionally, the findings were applied to both H-D and D-T separation systems, demonstrating consistency in mass transfer efficiency and validating the applicability of the optimal conditions in different hydrogen isotope separations. This research provides critical insights for optimizing tritium removal systems in heavy water reactors, contributing to enhanced reactor safety and performance.
Open AccessOptimization of Liquid Phase Catalytic Exchange Process for Hydrogen Isotope Separation Using Orthogonal Experiment Design
The Liquid Phase Catalytic Exchange (LPCE) process plays a pivotal role in the separation of hydrogen isotopes, particularly in applications such as tritium removal in heavy water reactors. Effective separation is crucial for maintaining reactor safety and efficiency. In this study, the optimal operating conditions for the LPCE process were determined through orthogonal experiments and validated in different hydrogen isotope systems. The experiments investigated key operational parameters, including the filling ratio of catalyst to packing (FR), operating temperature (T), superficial gas velocity (V), and gas-to-liquid flow rate ratio (λ), using a robust L16 orthogonal experiment design. The results indicated that V and FR had the most significant effects on the height equivalent to a theoretical plate (HETP), while λ exhibited the greatest impact on dedeuterization efficiency (DE). The optimal conditions obtained were V = 0.1 m/s, FR = 1:2, T = 70 °C, and λ = 2.5. Furthermore, the reproducibility of the optimal conditions was verified in LPCE columns with varying diameters (1.5 cm, 2.5 cm, 4.5 cm). Additionally, the findings were applied to both H-D and D-T separation systems, demonstrating consistency in mass transfer efficiency and validating the applicability of the optimal conditions in different hydrogen isotope separations. This research provides critical insights for optimizing tritium removal systems in heavy water reactors, contributing to enhanced reactor safety and performance.
- Open Access
- 22 July 2024
- Published by MDPI AG in Separations
- Vol. 11 (7) , 219
Hydrogen–Water Isotope Catalytic Exchange Process Analysis by Simulation
The hydrogen–water isotope catalytic exchange process has been widely applied in the tritium-containing water treatment process. It can be compared and analyzed conveniently with process simulation software. In this study, the catalytic exchange process was simulated by Aspen Plus software (V11). According to the simulation results, the main reaction process was that HDO in the liquid phase converts into HD in the gas phase, and the reaction mainly occurred at the bottom of the column, exhibiting a two-orders-of-magnitude-higher reaction amount compared to that observed in the top section. Different side reactions occur at distinct positions along the column, exhibiting a reaction amount that is lower by one to two orders of magnitude compared to the main reaction and aligning in the same direction as the main reaction. The optimum operating temperature is 60~80 °C, with the best performance observed at 70 °C, because of the large reaction equilibrium constant and the suitable ratio of vapor to hydrogen (1:4~1:1.5) in the gas phase. The influence of the residence time was investigated by introducing reaction kinetic equations. The residence time should be more than 1 s to ensure an adequate reaction. The influence of operating conditions on the hydrogen–water isotope catalytic exchange process can be deeply investigated by process simulation, and more mass transfer process quantities can be obtained. It plays a promoting role in guiding the process design and condition optimization.
- 22 July 2024
- Published by MDPI AG in Separations
- Vol. 11 (7) , 219
Open AccessHydrogen–Water Isotope Catalytic Exchange Process Analysis by Simulation
The hydrogen–water isotope catalytic exchange process has been widely applied in the tritium-containing water treatment process. It can be compared and analyzed conveniently with process simulation software. In this study, the catalytic exchange process was simulated by Aspen Plus software (V11). According to the simulation results, the main reaction process was that HDO in the liquid phase converts into HD in the gas phase, and the reaction mainly occurred at the bottom of the column, exhibiting a two-orders-of-magnitude-higher reaction amount compared to that observed in the top section. Different side reactions occur at distinct positions along the column, exhibiting a reaction amount that is lower by one to two orders of magnitude compared to the main reaction and aligning in the same direction as the main reaction. The optimum operating temperature is 60~80 °C, with the best performance observed at 70 °C, because of the large reaction equilibrium constant and the suitable ratio of vapor to hydrogen (1:4~1:1.5) in the gas phase. The influence of the residence time was investigated by introducing reaction kinetic equations. The residence time should be more than 1 s to ensure an adequate reaction. The influence of operating conditions on the hydrogen–water isotope catalytic exchange process can be deeply investigated by process simulation, and more mass transfer process quantities can be obtained. It plays a promoting role in guiding the process design and condition optimization.
- 17 May 2022
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 249, 106895
Efficient capture of radioactive iodine by ZIF-8 derived porous carbon
- 17 May 2022
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 249, 106895
Efficient capture of radioactive iodine by ZIF-8 derived porous carbon
- 1 February 2021
- Published by Elsevier in Computational Materials Science
- Vol. 188
First-Principles Study of the Effect of Doped Metal Atoms Pd, Mg and Ti on Tritium Release from Li2O (111) Surface
- 1 February 2021
- Published by Elsevier in Computational Materials Science
- Vol. 188
First-Principles Study of the Effect of Doped Metal Atoms Pd, Mg and Ti on Tritium Release from Li2O (111) Surface
- 1 December 2019
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 380, 120904
Superhydrophobic and superaerophilic hierarchical Pt@MIL-101/PVDF composite for hydrogen water isotope exchange reactions
- 1 December 2019
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 380, 120904
Superhydrophobic and superaerophilic hierarchical Pt@MIL-101/PVDF composite for hydrogen water isotope exchange reactions
- Open Access
- 13 March 2019
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 9 (15) , 8490-8497
First-principles study of the effect of dopants (Pd, Ni) on the formation and desorption of T 2 O from a Li 2 TiO 3 (001) surface
We investigated the effect of Pd and Ni dopants on the formation and desorption of tritiated water (T 2 O) molecules from the Li 2 TiO 3 (001) surface using first-principles calculations coupled with the climbing-image nudged elastic band method.
- 13 March 2019
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 9 (15) , 8490-8497
Open AccessFirst-principles study of the effect of dopants (Pd, Ni) on the formation and desorption of T 2 O from a Li 2 TiO 3 (001) surface
We investigated the effect of Pd and Ni dopants on the formation and desorption of tritiated water (T 2 O) molecules from the Li 2 TiO 3 (001) surface using first-principles calculations coupled with the climbing-image nudged elastic band method.
- 1 January 2019
- Published by Elsevier in Journal of Nuclear Materials
- Vol. 513, 232-240
Adsorption and diffusion mechanism of hydrogen atom on the Li2O (111) and (110) surfaces from first principles calculations
- 1 January 2019
- Published by Elsevier in Journal of Nuclear Materials
- Vol. 513, 232-240
Adsorption and diffusion mechanism of hydrogen atom on the Li2O (111) and (110) surfaces from first principles calculations
- 1 January 2017
- Published by China Science Publishing & Media Ltd. in Chinese Journal of Chromatography
- Vol. 35 (10) , 1023-1027
Hydrogen isotopes analysis by gas chromatography using metal-organic framework CPL-1 packed column
CPL-1 is a metal organic framework (MOF) with potential application as stationary phase material in gas chromatographic (GC) analysis, due to its large specific surface area, uniform pore size and good quantum sieving effect on hydrogen isotopes at low temperatures. Herein, a microporous column packed with CPL-1 was used at cryogenic temperature (77 K), and the column was 1.0 mm in inner diameter, 0.5 m in length. Single crystals of Al2O3 was used to build flow path for chromatographic carrier gas. The results showed that the adsorption of H2 and D2 with CPL-1 was 4 mmol/g at 77 K, which was better than MnCl2/γ -Al2O3 and γ -Al2O3. With the injection volume increasing from 0.25 mL to 2 mL, the results showed good linear relationship, and the relative error was less than 4%. The results indicated that the column packed with CPL-1 has wide linear range, good repeatability and high accuracy, and it has potential use in hydrogen isotope analysis with gas chromatography.
- 1 January 2017
- Published by China Science Publishing & Media Ltd. in Chinese Journal of Chromatography
- Vol. 35 (10) , 1023-1027
Hydrogen isotopes analysis by gas chromatography using metal-organic framework CPL-1 packed column
CPL-1 is a metal organic framework (MOF) with potential application as stationary phase material in gas chromatographic (GC) analysis, due to its large specific surface area, uniform pore size and good quantum sieving effect on hydrogen isotopes at low temperatures. Herein, a microporous column packed with CPL-1 was used at cryogenic temperature (77 K), and the column was 1.0 mm in inner diameter, 0.5 m in length. Single crystals of Al2O3 was used to build flow path for chromatographic carrier gas. The results showed that the adsorption of H2 and D2 with CPL-1 was 4 mmol/g at 77 K, which was better than MnCl2/γ -Al2O3 and γ -Al2O3. With the injection volume increasing from 0.25 mL to 2 mL, the results showed good linear relationship, and the relative error was less than 4%. The results indicated that the column packed with CPL-1 has wide linear range, good repeatability and high accuracy, and it has potential use in hydrogen isotope analysis with gas chromatography.