Tim Friedrich Raven
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tim Friedrich Raven has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Arash Moghaddam
Aschaffenburg Trauma and Orthopaedic Research Group, Center for Orthopaedics, Trauma Surgery and Sports Medicine, Hospital Aschaffenburg-Alzenau GGmbH, Am Hasenkopf 1, Aschaffenburg, Germany
7 shared publicationsWilhelm Friedl
Division of Orthopaedics and Trauma Surgery, Rotkreuzklinik Wertheim gGmbH, Wertheim am Main, Germany
4 shared publicationsA. Moghaddam
2 shared publicationsBahram Biglari
BG Trauma Center, Ludwigshafen, Germany
2 shared publicationsG. Schmidmaier
2 shared publicationsGerhard Schmidmaier
HTRG – Heidelberg Trauma Research Group, Division of Trauma and Reconstructive Surgery, Center for Orthopaedics, Trauma Surgery and Spinal Cord Injury, University Hospital Heidelberg
2 shared publications
Latest Publications
- 24 August 2026
- Published by Springer Nature
- p. 37-53
Writer Retrieval at Scale
- 30 March 2022
- Published by Springer Nature in MUSCULOSKELETAL SURGERY
- Vol. 107 (2) , 197-206
Clinical long-term results of radial head arthroplasty in comminuted radial head fractures
Modern radial head prostheses have recently become more common in the treatment of comminuted radial head fractures. The goal of this study was to evaluate how well the EVOLVE® modular metallic radial head implant prosthetic restores the functional range of motion and stability of the elbow. 30 patients with comminuted radial head fractures received an arthroplasty with an EVOLVE® prosthesis in our institution. 20 of those patients were available for long-term follow-up (mean > 10 years). The outcomes were assessed on the basis of pain, motion, and strength. The overall outcome was scored with functional rating scores. According to the Broberg–Morrey elbow evaluation score, after a mean follow-up period of 10.2 years, ten (50.0%) patients were rated as very good, four (20.0%) as good, six (30.0%) as satisfactory, and none as poor. In the long-term results the Broberg–Morrey score increased from 79 (in short-term results) to 89 points. The Disabilities of the Arm, Shoulder, and Hand (DASH) outcome measure questionnaire showed an average of 16.2 points. Initially, patients had an extension deficit of 20°, which was reduced to 5° at the latest follow-up. In our long-term results, an improvement in the function of the elbow was observed after arthroplasty using a metallic modular radial head implant. Comminuted radial head fractures with elbow instability can be treated effectively with the EVOLVE® radial head prosthesis, which restores stability in acute treatment. Our long-term results after 10.2 years demonstrate good functional outcome and low major complication rate. IV.
- 30 March 2022
- Published by Springer Nature in MUSCULOSKELETAL SURGERY
- Vol. 107 (2) , 197-206
Clinical long-term results of radial head arthroplasty in comminuted radial head fractures
Modern radial head prostheses have recently become more common in the treatment of comminuted radial head fractures. The goal of this study was to evaluate how well the EVOLVE® modular metallic radial head implant prosthetic restores the functional range of motion and stability of the elbow. 30 patients with comminuted radial head fractures received an arthroplasty with an EVOLVE® prosthesis in our institution. 20 of those patients were available for long-term follow-up (mean > 10 years). The outcomes were assessed on the basis of pain, motion, and strength. The overall outcome was scored with functional rating scores. According to the Broberg–Morrey elbow evaluation score, after a mean follow-up period of 10.2 years, ten (50.0%) patients were rated as very good, four (20.0%) as good, six (30.0%) as satisfactory, and none as poor. In the long-term results the Broberg–Morrey score increased from 79 (in short-term results) to 89 points. The Disabilities of the Arm, Shoulder, and Hand (DASH) outcome measure questionnaire showed an average of 16.2 points. Initially, patients had an extension deficit of 20°, which was reduced to 5° at the latest follow-up. In our long-term results, an improvement in the function of the elbow was observed after arthroplasty using a metallic modular radial head implant. Comminuted radial head fractures with elbow instability can be treated effectively with the EVOLVE® radial head prosthesis, which restores stability in acute treatment. Our long-term results after 10.2 years demonstrate good functional outcome and low major complication rate. IV.
- Open Access
- 9 March 2022
- Published by Elsevier in Chinese Journal of Traumatology
- Vol. 25 (6) , 336-344
Long-term results of olecranon fractures treated using the XS nail® system
- 9 March 2022
- Published by Elsevier in Chinese Journal of Traumatology
- Vol. 25 (6) , 336-344
Open AccessLong-term results of olecranon fractures treated using the XS nail® system
- 13 July 2021
- Published by Springer Nature in Der Unfallchirurg
- Vol. 125 (7) , 1-6
Notfallthorakotomie nach hämorrhagischem Schock bei traumatischer pelviner Blutung bei Schwerstverletztem
Zusammenfassung Es wird über einen Fall einer innerklinisch durchgeführten Thorakotomie mit nachfolgender direkter Reanimation am offenen Brustkorb eines polytraumatisierten Patienten berichtet. Notfallthorakotomien sind seltene Eingriffe in herausfordernden Situationen. Die Indikationsstellung ist oft eine Grenzentscheidung. In Kombination mit einer Kreislaufverkleinerung, beispielsweise durch Abklemmen der Aorta, verfolgt die Thorakotomie mit direkter Herzmassage das Ziel, die Durchblutung in den lebenswichtigen koronaren und zerebralen Kreisläufen aufrechtzuerhalten, Blutverluste aus distal gelegenen Blutungsquellen zu minimieren und reversible Ursachen zu beheben. Letztlich kann die Thorakotomie im Zweifel zum Wohle des Patienten bei entsprechender Indikation durchgeführt werden.
- 13 July 2021
- Published by Springer Nature in Der Unfallchirurg
- Vol. 125 (7) , 1-6
Notfallthorakotomie nach hämorrhagischem Schock bei traumatischer pelviner Blutung bei Schwerstverletztem
Zusammenfassung Es wird über einen Fall einer innerklinisch durchgeführten Thorakotomie mit nachfolgender direkter Reanimation am offenen Brustkorb eines polytraumatisierten Patienten berichtet. Notfallthorakotomien sind seltene Eingriffe in herausfordernden Situationen. Die Indikationsstellung ist oft eine Grenzentscheidung. In Kombination mit einer Kreislaufverkleinerung, beispielsweise durch Abklemmen der Aorta, verfolgt die Thorakotomie mit direkter Herzmassage das Ziel, die Durchblutung in den lebenswichtigen koronaren und zerebralen Kreisläufen aufrechtzuerhalten, Blutverluste aus distal gelegenen Blutungsquellen zu minimieren und reversible Ursachen zu beheben. Letztlich kann die Thorakotomie im Zweifel zum Wohle des Patienten bei entsprechender Indikation durchgeführt werden.
- 1 July 2021
- Published by Elsevier in Journal of Orthopaedics
- Vol. 26, 1-7
Long-term results after over 17 years – Intramedullary gliding nail as treatment for traumatic femoral neck fractures
- 1 July 2021
- Published by Elsevier in Journal of Orthopaedics
- Vol. 26, 1-7
Long-term results after over 17 years – Intramedullary gliding nail as treatment for traumatic femoral neck fractures
- Open Access
- 11 March 2021
- Published by Springer Nature in Indian Journal of Orthopaedics
- Vol. 55 (3) , 621-628
Treatment of Traumatic Femoral Neck Fractures with an Intramedullary Nail in Osteoporotic Bones
Purpose Sufficient anchoring of intramedullary osteosynthesis in the femoral head in a femoral neck fracture is a challenge with increasing age of the patients and decreasing bone quality. For older patients with inferior bone quality, it has not been investigated whether the application of an intramedullary force carrier, as a minimally invasive and rapid intervention, can provide a considerable benefit and reduce the postoperative complication and lethality rate. This retrospective study aimed to investigate the stability and functionality after the acute treatment of a femoral neck fracture in osteoporotic bone using an intramedullary force carrier even with higher grade fracture types. Material and Methods The retrospective analysis was based on a collective of 82 patients over 60 years of age with a femoral neck fracture treated with a gliding nail in our centre between 1999 and 2006. Results The average time to follow-up was 69.05 months (median 71.0; minimum 27.0–maximum 108.0). Female patients made up more than two-thirds of the patient collective at 63 of the 82 patients (76.83%). The average age of the patients was 77.76 years (median 78.00; range 60.00–93.00). In 66 patients (80.49%), the implantation showed good results and no complications or further treatments. 24/82 patients of our collective had died in our re-evaluation. In no case, a pseudarthrosis or severe impaction with neck shortening occurred (loss of offset). 11/82 patients had femoral head necrosis which led to total hip replacement in 8 cases, a hemiarthroplasty in 2 cases and in 1 case a remaining Girdlestone situation because of a deep infection. Another five patients also had to undergo a total hip replacement because of a central perforation of the blade in one case, breakout of the blade after another fall in another two cases and a lateral dislocation of the blade in two cases. Conclusion The use of an intramedullary force carrier in the osteoporotic bone can mean distinct advantages for the selected patient as a minimally invasive and rapid surgical method compared to extensive surgery, even in the case of severe injuries. However, the advantages and disadvantages for the patient should be considered critically.
- 11 March 2021
- Published by Springer Nature in Indian Journal of Orthopaedics
- Vol. 55 (3) , 621-628
Open AccessTreatment of Traumatic Femoral Neck Fractures with an Intramedullary Nail in Osteoporotic Bones
Purpose Sufficient anchoring of intramedullary osteosynthesis in the femoral head in a femoral neck fracture is a challenge with increasing age of the patients and decreasing bone quality. For older patients with inferior bone quality, it has not been investigated whether the application of an intramedullary force carrier, as a minimally invasive and rapid intervention, can provide a considerable benefit and reduce the postoperative complication and lethality rate. This retrospective study aimed to investigate the stability and functionality after the acute treatment of a femoral neck fracture in osteoporotic bone using an intramedullary force carrier even with higher grade fracture types. Material and Methods The retrospective analysis was based on a collective of 82 patients over 60 years of age with a femoral neck fracture treated with a gliding nail in our centre between 1999 and 2006. Results The average time to follow-up was 69.05 months (median 71.0; minimum 27.0–maximum 108.0). Female patients made up more than two-thirds of the patient collective at 63 of the 82 patients (76.83%). The average age of the patients was 77.76 years (median 78.00; range 60.00–93.00). In 66 patients (80.49%), the implantation showed good results and no complications or further treatments. 24/82 patients of our collective had died in our re-evaluation. In no case, a pseudarthrosis or severe impaction with neck shortening occurred (loss of offset). 11/82 patients had femoral head necrosis which led to total hip replacement in 8 cases, a hemiarthroplasty in 2 cases and in 1 case a remaining Girdlestone situation because of a deep infection. Another five patients also had to undergo a total hip replacement because of a central perforation of the blade in one case, breakout of the blade after another fall in another two cases and a lateral dislocation of the blade in two cases. Conclusion The use of an intramedullary force carrier in the osteoporotic bone can mean distinct advantages for the selected patient as a minimally invasive and rapid surgical method compared to extensive surgery, even in the case of severe injuries. However, the advantages and disadvantages for the patient should be considered critically.
- Open Access
- 22 April 2020
- Published by Open Medical Publishing in Orthopedic Reviews
- Vol. 12 (1) , 31-36
Evaluation of two different types of radial head prosthesis in practical use. Using either Evolve® or MoPyC® radial head prosthesis in the treatment of comminuted radial head fractures
The aim of this retrospective study was to undertake a comparative evaluation of the Evolve® modular metallic radial head implant prosthesis and the MoPyC® pyrocarbon prosthesis in acute care. Seventyfive patients having a comminuted radial head fracture with an Evolve® prosthesis (=G1) and 11 with a MoPyC® prosthesis (=G2) were available for a follow-up. Postoperative patient outcomes were evaluated according to a standardized follow-up protocol which included the Morrey rating system. Assessment criteria were range of motion (ROM), functional scores, and rate of complications. G1 showed a mean Morrey score of 86 points. Four direct prosthesis complications were observed in this group (n=75). The average achieved Morrey score in G2 was 84 points. In this group (n=11), 2 direct prosthesis complications were diagnosed. The average range of motion did not differ greatly between both groups. Radial head replacement with either prosthesis yielded sufficient to satisfactory results in a mid-term perspective regarding the range of motion and function of the elbow joint when performed in carefully selected patients. The Evolve® Prothesis appears to show a slightly lower rate of complication by way of a similar functional outcome.
- 22 April 2020
- Published by Open Medical Publishing in Orthopedic Reviews
- Vol. 12 (1) , 31-36
Open AccessEvaluation of two different types of radial head prosthesis in practical use. Using either Evolve® or MoPyC® radial head prosthesis in the treatment of comminuted radial head fractures
The aim of this retrospective study was to undertake a comparative evaluation of the Evolve® modular metallic radial head implant prosthesis and the MoPyC® pyrocarbon prosthesis in acute care. Seventyfive patients having a comminuted radial head fracture with an Evolve® prosthesis (=G1) and 11 with a MoPyC® prosthesis (=G2) were available for a follow-up. Postoperative patient outcomes were evaluated according to a standardized follow-up protocol which included the Morrey rating system. Assessment criteria were range of motion (ROM), functional scores, and rate of complications. G1 showed a mean Morrey score of 86 points. Four direct prosthesis complications were observed in this group (n=75). The average achieved Morrey score in G2 was 84 points. In this group (n=11), 2 direct prosthesis complications were diagnosed. The average range of motion did not differ greatly between both groups. Radial head replacement with either prosthesis yielded sufficient to satisfactory results in a mid-term perspective regarding the range of motion and function of the elbow joint when performed in carefully selected patients. The Evolve® Prothesis appears to show a slightly lower rate of complication by way of a similar functional outcome.
- 1 January 2020
- Published by Elsevier in Journal of Orthopaedics
- Vol. 17, 208-214
LIPUS vs. reaming in non-union treatment: Cytokine expression course as a tool for evaluation and differentiation of non-union therapy
- 1 January 2020
- Published by Elsevier in Journal of Orthopaedics
- Vol. 17, 208-214
LIPUS vs. reaming in non-union treatment: Cytokine expression course as a tool for evaluation and differentiation of non-union therapy