Yong-Kie Wong
Yong-Kie Wong has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Hui-Ling Chen
Division of Dental Implant, Department of Stomatology, Taichung Veterans General Hospital, Taichung, Taiwan, ROC; School of Dentistry, National Yang-Ming University, Taipei, Taiwan, ROC
2 shared publicationsChiou-Tuz Chang
Department of Oral and Maxillofacial Surgery, Taichung Veterans General Hospital, Taichung, Taiwan, ROC
1 shared publicationDa-Tain Bau
Terry Fox Cancer Research Laboratory, Department of Medical Research, China Medical University Hospital, Taichung, Taiwan, ROC; Graduate Institute of Clinical Medical Science, China Medical University, Taichung, Taiwan, ROC; Department of Bioinformatics and Medical Engineering, Asia University, Taichung, Taiwan, ROC
1 shared publicationJohn Wang
Department of Pathology, China Medical University Hospital, Taichung, Taiwan, ROC
1 shared publicationKuo-Wei Chang
Department of Dentistry, School of Dentistry, National Yang-Ming University, Taipei, Taiwan, ROC
1 shared publicationKwong-Chung Tung
Department of Veterinary Medicine, College of Veterinary Medicine, National Chung Hsing University, Taichung, Taiwan, ROC
1 shared publication
Latest Publications
- Open Access
- 1 November 2018
- Published by Wolters Kluwer Health in Journal of the Chinese Medical Association
- Vol. 81 (11) , 970-976
Accuracy of implant placement with a computer-aided fabricated surgical template with guided parallel pins: A pilot study
A precise positioning for dental implant placement is important for further prosthesis fabrication and maintenance. Computer-aided surgery has been developed to transfer digitally planned implant positioning to the patient over the past decades. This study aimed to evaluate the accuracy of a computer-aided laboratory-fabricated surgical template. A further objective was to compare the accuracy between in vivo and in vitro groups. A total of 20 implants were placed in the posterior tooth region through the aid of surgical templates on 17 partially edentulous patients in the in vivo group. The surgical template was fabricated in laboratory after virtual implant planning was completed using computer software. In the in vitro group, the same procedures were performed on the models without placing fixture with the same templates used in surgery. Deviations of the implant access at the implant platform level and apical region, as well as the angle deviations between the virtual planning data and the surgical results, were measured using a follow-up Cone Beam Computerized Tomography (CBCT) investigation, and image fusion with planning data. The median deviation at platform level, apex and angulation was 0.95 mm (0.3-1.3 mm),1.35 mm (0.1-3.6 mm) and 3.92° (0.44-11.66°) respectively in the in vivo group; and 0.4 mm (0-1.0 mm), 0.65 mm (0.1-1.9 mm), 2.16° (0.17-6.91) respectively in the in vitro group. The in vitro group displayed significantly less deviation (p < 0.05). The data from this study shows that computer-aided laboratory-fabricated template may be a reliable tool for implant placement. However, the clinical conditions seem to affect the accuracy of the template.
- 1 November 2018
- Published by Wolters Kluwer Health in Journal of the Chinese Medical Association
- Vol. 81 (11) , 970-976
Open AccessAccuracy of implant placement with a computer-aided fabricated surgical template with guided parallel pins: A pilot study
A precise positioning for dental implant placement is important for further prosthesis fabrication and maintenance. Computer-aided surgery has been developed to transfer digitally planned implant positioning to the patient over the past decades. This study aimed to evaluate the accuracy of a computer-aided laboratory-fabricated surgical template. A further objective was to compare the accuracy between in vivo and in vitro groups. A total of 20 implants were placed in the posterior tooth region through the aid of surgical templates on 17 partially edentulous patients in the in vivo group. The surgical template was fabricated in laboratory after virtual implant planning was completed using computer software. In the in vitro group, the same procedures were performed on the models without placing fixture with the same templates used in surgery. Deviations of the implant access at the implant platform level and apical region, as well as the angle deviations between the virtual planning data and the surgical results, were measured using a follow-up Cone Beam Computerized Tomography (CBCT) investigation, and image fusion with planning data. The median deviation at platform level, apex and angulation was 0.95 mm (0.3-1.3 mm),1.35 mm (0.1-3.6 mm) and 3.92° (0.44-11.66°) respectively in the in vivo group; and 0.4 mm (0-1.0 mm), 0.65 mm (0.1-1.9 mm), 2.16° (0.17-6.91) respectively in the in vitro group. The in vitro group displayed significantly less deviation (p < 0.05). The data from this study shows that computer-aided laboratory-fabricated template may be a reliable tool for implant placement. However, the clinical conditions seem to affect the accuracy of the template.
- Open Access
- 1 October 2018
- Published by Wolters Kluwer Health in Journal of the Chinese Medical Association
- Vol. 81 (10) , 920-925
Effects of non-thermal plasma on sandblasted titanium dental implants in beagle dogs
Background: In this study, we investigated the effects of treating dental implants made from titanium with argon based non-thermal plasma, immediately before insertion on implant stability and bone formation. Biodegradable sandblasting and acid etching had been previously used to modify the surface of the implants. Methods: To obtain data for 4-time points in triplicate with references, a total of 36 dental implants were divided into 2 groups; 18 implants served as the experimental group and received a spray containing non-thermal plasma, while the other 18 implants served as controls. Two treated and two untreated implants were each inserted in the jaws of 9 beagle dogs. After periods of 4, 8, and 12 weeks, the Implant Stability Quotient scores were determined and histometric values obtained. Results: Plasma spray treatment increased the healing time slightly during the early recovery period (4th to 8th week, p = 0.1595 and 0.1041, respectively), but was not profoundly effective in the later recovery stage (12th week, p = 0.4942). Both non-decalcified histometric measurements and bone growth analysis showed no statistically significant differences between the plasma spray group and the controls at 4, 8, and 12 weeks. Conclusion: Non-thermal plasma did not enhance the stability of the implants nor did it increase bone formation in our animal models.
- 1 October 2018
- Published by Wolters Kluwer Health in Journal of the Chinese Medical Association
- Vol. 81 (10) , 920-925
Open AccessEffects of non-thermal plasma on sandblasted titanium dental implants in beagle dogs
Background: In this study, we investigated the effects of treating dental implants made from titanium with argon based non-thermal plasma, immediately before insertion on implant stability and bone formation. Biodegradable sandblasting and acid etching had been previously used to modify the surface of the implants. Methods: To obtain data for 4-time points in triplicate with references, a total of 36 dental implants were divided into 2 groups; 18 implants served as the experimental group and received a spray containing non-thermal plasma, while the other 18 implants served as controls. Two treated and two untreated implants were each inserted in the jaws of 9 beagle dogs. After periods of 4, 8, and 12 weeks, the Implant Stability Quotient scores were determined and histometric values obtained. Results: Plasma spray treatment increased the healing time slightly during the early recovery period (4th to 8th week, p = 0.1595 and 0.1041, respectively), but was not profoundly effective in the later recovery stage (12th week, p = 0.4942). Both non-decalcified histometric measurements and bone growth analysis showed no statistically significant differences between the plasma spray group and the controls at 4, 8, and 12 weeks. Conclusion: Non-thermal plasma did not enhance the stability of the implants nor did it increase bone formation in our animal models.
- Open Access
- 1 April 2018
- Published by Wolters Kluwer Health in Journal of the Chinese Medical Association
- Vol. 81 (4) , 370-375
The correlation between HIF-1 alpha and VEGF in oral squamous cell carcinomas: Expression patterns and quantitative immunohistochemical analysis
Urrence and metastasis, the expression percentages of HIF-1α and VEGF also were analyzed. Methods: Thirty-eight patients (8 hyperkeratosis, 30 oral squamous cell carcinoma) were included in this study. In the follow-up period, 5 OSCC patients had metastasis and 12 OSCC patients had local recurrence. We used computer-assisted image processing to analyze immunohistochemistry (IHC). The quantitative analysis of IHC slides, including upper-layer epithelium (U) and lower-layer epithelium (L), was calculated. Results: We found homogeneous expression of VEGF in the epithelium. However, two patterns of HIF-1α expression were observed: homogeneous and heterogeneous. The highest U + L layer percentage in HIF-1α and VEF expression had significant association in tumor metastasis and recurrence (p< 0.001 in HIF-1α and p< 0.001 in VEGF). U + L layer HIF-1α expression percentage was >156.4%, and the survival rate was poor (p < 0.001). Conclusion: HIF-1α expression was not only influenced by tumor hypoxia, it also reflected tumor cell characteristics. High concentrations of VEGF and HIF-1α may have value as prognostic markers of tumor metastasis and recurrence....
- 1 April 2018
- Published by Wolters Kluwer Health in Journal of the Chinese Medical Association
- Vol. 81 (4) , 370-375
Open AccessThe correlation between HIF-1 alpha and VEGF in oral squamous cell carcinomas: Expression patterns and quantitative immunohistochemical analysis
Urrence and metastasis, the expression percentages of HIF-1α and VEGF also were analyzed. Methods: Thirty-eight patients (8 hyperkeratosis, 30 oral squamous cell carcinoma) were included in this study. In the follow-up period, 5 OSCC patients had metastasis and 12 OSCC patients had local recurrence. We used computer-assisted image processing to analyze immunohistochemistry (IHC). The quantitative analysis of IHC slides, including upper-layer epithelium (U) and lower-layer epithelium (L), was calculated. Results: We found homogeneous expression of VEGF in the epithelium. However, two patterns of HIF-1α expression were observed: homogeneous and heterogeneous. The highest U + L layer percentage in HIF-1α and VEF expression had significant association in tumor metastasis and recurrence (p< 0.001 in HIF-1α and p< 0.001 in VEGF). U + L layer HIF-1α expression percentage was >156.4%, and the survival rate was poor (p < 0.001). Conclusion: HIF-1α expression was not only influenced by tumor hypoxia, it also reflected tumor cell characteristics. High concentrations of VEGF and HIF-1α may have value as prognostic markers of tumor metastasis and recurrence....