Li Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Li Yang has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Mingfeng Ge
Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Science, Suzhou 215163, P. R. China
4 shared publications- Wen-Fei Dong
Department of Biomaterials and Stem Cells, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Science, Suzhou 215163, China
4 shared publications Qiannan You
School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230026, PR China; Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Science, Suzhou 215163, PR China
3 shared publications- Zhimin Chang
CAS Key Laboratory of Bio Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology Chinese Academy of Sciences, Suzhou, China
3 shared publications - Li Li
Department of Biomaterials and Stem Cells Suzhou Institute of Biomedical Engineering and Technology Chinese Academy of Science (CAS) Suzhou China
2 shared publications Linlin Zhuang
School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230026, PR China; Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Science, Suzhou 215163, PR China
2 shared publications
Latest Publications
- 23 May 2024
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 12 (23) , 8561-8568
MXene quantum dot functionalized bimetallic MOFs as a label-free aptasensor for highly sensitive detection of exosomes
Exosomes have attracted increasing attention in the early diagnosis of tumors due to their participation in physiological and pathological processes. Herein, a novel label-free aptasensor based on the CuNi bimetallic metal–organic frameworks (MOFs) that was decorated with MXene quantum dots (MQDs) was fabricated for exosome sensing. The CuNi-MOFs functionalized with dual specific aptamers, CD63 and MUC1, served as an ideal nanocarrier and catalyst for efficient recognition and capture of target exosomes. Meanwhile, the MQDs with excellent electron transfer can promote the electrochemical catalytic performance of this designed aptasensor. It is noteworthy that the large specific surface area of 2D bimetallic CuNi-MOF nanosheets can offer plenty of exposed active sites and facilitate the connection of aptamers, thereby achieving the goal of specific capture and detection of exosomes. The as-prepared electrochemical aptasensor possesses a wide linear range of 1 × 101 to 1 × 106 particles μL−1 for exosome detection and a low detection limit of 5 particles μL−1 (S/N = 3). Besides, the as-prepared aptasensor exhibited satisfactory electrochemical stability for the detection of exosomes, which can provide new ideas for clinical detection and tumor diagnosis.
- 23 May 2024
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 12 (23) , 8561-8568
MXene quantum dot functionalized bimetallic MOFs as a label-free aptasensor for highly sensitive detection of exosomes
Exosomes have attracted increasing attention in the early diagnosis of tumors due to their participation in physiological and pathological processes. Herein, a novel label-free aptasensor based on the CuNi bimetallic metal–organic frameworks (MOFs) that was decorated with MXene quantum dots (MQDs) was fabricated for exosome sensing. The CuNi-MOFs functionalized with dual specific aptamers, CD63 and MUC1, served as an ideal nanocarrier and catalyst for efficient recognition and capture of target exosomes. Meanwhile, the MQDs with excellent electron transfer can promote the electrochemical catalytic performance of this designed aptasensor. It is noteworthy that the large specific surface area of 2D bimetallic CuNi-MOF nanosheets can offer plenty of exposed active sites and facilitate the connection of aptamers, thereby achieving the goal of specific capture and detection of exosomes. The as-prepared electrochemical aptasensor possesses a wide linear range of 1 × 101 to 1 × 106 particles μL−1 for exosome detection and a low detection limit of 5 particles μL−1 (S/N = 3). Besides, the as-prepared aptasensor exhibited satisfactory electrochemical stability for the detection of exosomes, which can provide new ideas for clinical detection and tumor diagnosis.
- Open Access
High-Performance Detection of Exosomes Based on Synergistic Amplification of Amino-Functionalized Fe3O4 Nanoparticles and Two-Dimensional MXene Nanosheets
Exosomes derived from cancer cells have been recognized as a promising biomarker for minimally invasive liquid biopsy. Herein, a novel sandwich-type biosensor was fabricated for highly sensitive detection of exosomes. Amino-functionalized Fe3O4 nanoparticles were synthesized as a sensing interface with a large surface area and rapid enrichment capacity, while two-dimensional MXene nanosheets were used as signal amplifiers with excellent electrical properties. Specifically, CD63 aptamer attached Fe3O4 nanoprobes capture the target exosomes. MXene nanosheets modified with epithelial cell adhesion molecule (EpCAM) aptamer were tethered on the electrode surface to enhance the quantification of exosomes captured with the detection of remaining protein sites. With such a design, the proposed biosensor showed a wide linear range from 102 particles μL−1 to 107 particles μL−1 for sensing 4T1 exosomes, with a low detection limit of 43 particles μL−1. In addition, this sensing platform can determine four different tumor cell types (4T1, Hela, HepG2, and A549) using surface proteins corresponding to aptamers 1 and 2 (CD63 and EpCAM) and showcases good specificity in serum samples. These preliminary results demonstrate the feasibility of establishing a sensitive, accurate, and inexpensive electrochemical sensor for detecting exosome concentrations and species. Moreover, they provide a significant reference for exosome applications in clinical settings, such as liquid biopsy and early cancer diagnosis.
Open AccessHigh-Performance Detection of Exosomes Based on Synergistic Amplification of Amino-Functionalized Fe3O4 Nanoparticles and Two-Dimensional MXene Nanosheets
Exosomes derived from cancer cells have been recognized as a promising biomarker for minimally invasive liquid biopsy. Herein, a novel sandwich-type biosensor was fabricated for highly sensitive detection of exosomes. Amino-functionalized Fe3O4 nanoparticles were synthesized as a sensing interface with a large surface area and rapid enrichment capacity, while two-dimensional MXene nanosheets were used as signal amplifiers with excellent electrical properties. Specifically, CD63 aptamer attached Fe3O4 nanoprobes capture the target exosomes. MXene nanosheets modified with epithelial cell adhesion molecule (EpCAM) aptamer were tethered on the electrode surface to enhance the quantification of exosomes captured with the detection of remaining protein sites. With such a design, the proposed biosensor showed a wide linear range from 102 particles μL−1 to 107 particles μL−1 for sensing 4T1 exosomes, with a low detection limit of 43 particles μL−1. In addition, this sensing platform can determine four different tumor cell types (4T1, Hela, HepG2, and A549) using surface proteins corresponding to aptamers 1 and 2 (CD63 and EpCAM) and showcases good specificity in serum samples. These preliminary results demonstrate the feasibility of establishing a sensitive, accurate, and inexpensive electrochemical sensor for detecting exosome concentrations and species. Moreover, they provide a significant reference for exosome applications in clinical settings, such as liquid biopsy and early cancer diagnosis.
- 22 August 2022
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 216, 114647
Hierarchical Au nanoarrays functionalized 2D Ti2CTx MXene membranes for the detection of exosomes isolated from human lung carcinoma cells
- 22 August 2022
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 216, 114647
Hierarchical Au nanoarrays functionalized 2D Ti2CTx MXene membranes for the detection of exosomes isolated from human lung carcinoma cells
- Open Access
- 11 November 2021
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 9
Multifunctional Gold Nano-Cytosensor With Quick Capture, Electrochemical Detection, and Non-Invasive Release of Circulating Tumor Cells for Early Cancer Treatment
Circulating tumor cells (CTCs) are metastatic tumor cells that shed into the blood from solid primary tumors, and their existence significantly increases the risk of metastasis and recurrence. The timely discovery and detection of CTCs are of considerable importance for the early diagnosis and treatment of metastasis. However, the low number of CTCs hinders their detection. In the present study, an ultrasensitive electrochemical cytosensor for specific capture, quantitative detection, and noninvasive release of EpCAM-positive tumor cells was developed. The biosensor was manufactured using gold nanoparticles (AuNPs) to modify the electrode. Three types of AuNPs with controllable sizes and conjugated with a targeting molecule of monoclonal anti-EpCAM antibody were used in this study. Electrochemical impedance spectroscopy (EIS) and differential pulse voltammetry (DPV) of the cytosensors were performed to evaluate the cell capture efficiency and performance. The captured 4T1 cells by the AuNPs hindered electron transport efficiency, resulting in increased EIS responses. The cell capture response recorded using EIS or DPV indicated that the optimal AuNPs size should be 17 nm. The cell capture response changed linearly with the concentration range from 8.0 × 10 to 1 × 107 cells/mL, and the limit of detection was 50 cells/mL. After these measurements, glycine-HCl (Gly-HCl) was used as an antibody eluent to destroy the binding between antigen and antibody to release the captured tumor cells without compromising their viability for further clinical research. This protocol realizes rapid detection of CTCs with good stability, acceptable assay precision, significant fabrication reproducibility with a relative standard deviation of 2.09%, and good recovery of cells. Our results indicate that the proposed biosensor is promising for the early monitoring of CTCs and may help customize personalized treatment options.
- 11 November 2021
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 9
Open AccessMultifunctional Gold Nano-Cytosensor With Quick Capture, Electrochemical Detection, and Non-Invasive Release of Circulating Tumor Cells for Early Cancer Treatment
Circulating tumor cells (CTCs) are metastatic tumor cells that shed into the blood from solid primary tumors, and their existence significantly increases the risk of metastasis and recurrence. The timely discovery and detection of CTCs are of considerable importance for the early diagnosis and treatment of metastasis. However, the low number of CTCs hinders their detection. In the present study, an ultrasensitive electrochemical cytosensor for specific capture, quantitative detection, and noninvasive release of EpCAM-positive tumor cells was developed. The biosensor was manufactured using gold nanoparticles (AuNPs) to modify the electrode. Three types of AuNPs with controllable sizes and conjugated with a targeting molecule of monoclonal anti-EpCAM antibody were used in this study. Electrochemical impedance spectroscopy (EIS) and differential pulse voltammetry (DPV) of the cytosensors were performed to evaluate the cell capture efficiency and performance. The captured 4T1 cells by the AuNPs hindered electron transport efficiency, resulting in increased EIS responses. The cell capture response recorded using EIS or DPV indicated that the optimal AuNPs size should be 17 nm. The cell capture response changed linearly with the concentration range from 8.0 × 10 to 1 × 107 cells/mL, and the limit of detection was 50 cells/mL. After these measurements, glycine-HCl (Gly-HCl) was used as an antibody eluent to destroy the binding between antigen and antibody to release the captured tumor cells without compromising their viability for further clinical research. This protocol realizes rapid detection of CTCs with good stability, acceptable assay precision, significant fabrication reproducibility with a relative standard deviation of 2.09%, and good recovery of cells. Our results indicate that the proposed biosensor is promising for the early monitoring of CTCs and may help customize personalized treatment options.
- 1 September 2018
- Published by Elsevier in Journal of Chromatography A
- Vol. 1569, 222-228
Simultaneous determination of trace Aflatoxin B1 and Ochratoxin A by aptamer-based microchip capillary electrophoresis in food samples
- 1 September 2018
- Published by Elsevier in Journal of Chromatography A
- Vol. 1569, 222-228
Simultaneous determination of trace Aflatoxin B1 and Ochratoxin A by aptamer-based microchip capillary electrophoresis in food samples
- 28 August 2018
- Published by Wiley in Journal of Separation Science
- Vol. 41 (19) , 3772-3781
Rapid quantification of aloin A and B in aloe plants and aloe‐containing beverages, and pharmaceutical preparations by microchip capillary electrophoresis with laser induced fluorescence detection
A microchip capillary electrophoresis coupled with laser induced fluorescence detection method for the fast determination of aloin was developed and comprehensively applied for the quantification of aloin A and B present in seven aloe plant species, 42 aloin‐containing crude drugs, ten aloe pharmaceutical preparations, and four aloe gel‐containing functional foods. The excitation and emission wavelengths for detection of both aloins were set at 473 and 520 nm, respectively. Sample analysis on a 35 mm length of glass microchip channel was completed within 40 s. An interference study indicated that the other main anthraquinones present in the samples did not interrupt with the target aloins detection, demonstrating the good selectivity of this method. It is demonstrated that this method is fast, facile, and specific for determination of aloin A and B from matrix samples which can be applied to the quality control of a wide varieties of aloe species and aloe‐derived products.
- 28 August 2018
- Published by Wiley in Journal of Separation Science
- Vol. 41 (19) , 3772-3781
Rapid quantification of aloin A and B in aloe plants and aloe‐containing beverages, and pharmaceutical preparations by microchip capillary electrophoresis with laser induced fluorescence detection
A microchip capillary electrophoresis coupled with laser induced fluorescence detection method for the fast determination of aloin was developed and comprehensively applied for the quantification of aloin A and B present in seven aloe plant species, 42 aloin‐containing crude drugs, ten aloe pharmaceutical preparations, and four aloe gel‐containing functional foods. The excitation and emission wavelengths for detection of both aloins were set at 473 and 520 nm, respectively. Sample analysis on a 35 mm length of glass microchip channel was completed within 40 s. An interference study indicated that the other main anthraquinones present in the samples did not interrupt with the target aloins detection, demonstrating the good selectivity of this method. It is demonstrated that this method is fast, facile, and specific for determination of aloin A and B from matrix samples which can be applied to the quality control of a wide varieties of aloe species and aloe‐derived products.