Todd Bandhauer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Todd Bandhauer has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- Shane Garland
Department of Mechanical Engineering, Colorado State University, 1374 Campus Delivery, Fort Collins, CO 80523, USA
3 shared publications - Bret Windom
Walter Scott Engineering, Colorado State University, Fort Collins, CO 80523, USA
2 shared publications - Daniel B. Olsen
Department of Mechanical Engineering, Colorado State University, Fort Collins, CO 80523, USA
2 shared publications Jack Kotovsky
Lawrence Livermore National Laboratory
2 shared publicationsJason C. Quinn
2 shared publicationsJulie Hamilton
Lawrence Livermore National Laboratory
2 shared publications
Latest Publications
- 1 January 2026
- Published by Begell House Inc. Publishers in International Journal of Energy for a Clean Environment
- Vol. 27 (1) , 1-21
MODELING AND EXPERIMENTAL VALIDATION OF THE AIR DELIVERY SYSTEM FOR SOLID OXIDE FUEL CELL POWER GENERATION
Distributed power generation systems can be used in the electric grid to reduce peak loads, raise power quality, and reduce/eliminate transmission losses. One distributed energy system with distinct advantages is the Solid Oxide Fuel Cell (SOFC) integrated with an Internal Combustion Engine (ICE). This research aimed to produce and test a high-efficiency air delivery system that supports the SOFC-ICE to generate power on the scale of 80 kW, which has the capability to operate at electric efficiencies as high as 70%. The air balance of plant (BOP) is designed to create cost-effective preheating. To accomplish this, the system utilizes low-speed scroll-type rotating compressors alongside brazed plate and frame heat exchangers. The scroll compressors were modeled in Gamma Technologies Suite (GT-Suite) and the remaining air BOP system was modeled with thermodynamic and heat transfer equations. Testing was done on the compressors and heat exchangers to validate the model, which was used to predict performance over a range of conditions. Both compressors were operated between 20 g/s and 60 g/s, while the temperature was swept from 200°C to 600°C, which yielded compressor efficiencies over 60% and heat exchanger effectiveness over 0.90. The validated model was used to predict performance at full power and in part-load conditions. A turn-down analysis was conducted with a ratio of 3:1 to see how the system would perform at start-up, part-load, and full-load conditions.
- 1 January 2026
- Published by Begell House Inc. Publishers in International Journal of Energy for a Clean Environment
- Vol. 27 (1) , 1-21
MODELING AND EXPERIMENTAL VALIDATION OF THE AIR DELIVERY SYSTEM FOR SOLID OXIDE FUEL CELL POWER GENERATION
Distributed power generation systems can be used in the electric grid to reduce peak loads, raise power quality, and reduce/eliminate transmission losses. One distributed energy system with distinct advantages is the Solid Oxide Fuel Cell (SOFC) integrated with an Internal Combustion Engine (ICE). This research aimed to produce and test a high-efficiency air delivery system that supports the SOFC-ICE to generate power on the scale of 80 kW, which has the capability to operate at electric efficiencies as high as 70%. The air balance of plant (BOP) is designed to create cost-effective preheating. To accomplish this, the system utilizes low-speed scroll-type rotating compressors alongside brazed plate and frame heat exchangers. The scroll compressors were modeled in Gamma Technologies Suite (GT-Suite) and the remaining air BOP system was modeled with thermodynamic and heat transfer equations. Testing was done on the compressors and heat exchangers to validate the model, which was used to predict performance over a range of conditions. Both compressors were operated between 20 g/s and 60 g/s, while the temperature was swept from 200°C to 600°C, which yielded compressor efficiencies over 60% and heat exchanger effectiveness over 0.90. The validated model was used to predict performance at full power and in part-load conditions. A turn-down analysis was conducted with a ratio of 3:1 to see how the system would perform at start-up, part-load, and full-load conditions.
- 10 December 2025
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 59 (50) , 27230-27243
Evaluating Thermal Efficiency and Economic Impacts in Supplying Energy Demands for Direct Air Capture
Direct air capture (DAC) technologies that remove CO2 directly from the atmosphere are needed to meet international goals of limiting the atmospheric temperature increase before 2100. Operating costs, including the cost of energy inputs, currently limit the rapid deployment of DAC systems. An abundance of untapped and abandoned geothermal resources provides an opportunity to utilize this thermal energy beneath the earth's surface to reduce the financial and energy costs of DAC. In this study, thermodynamic models of applicable renewable energy scenarios for fulfilling heating and electrical requirements of DAC were analyzed using ASPEN Plus. Individual components were optimized within the geothermal-DAC-coupled systems to quantify specific costs of implementation. The results were integrated into a technoeconomic analysis to provide a holistic perspective to optimize DAC-coupled renewable energy systems. The analysis found that scenarios using geothermal heat for CO2 desorption with either solar and batteries or an organic Rankine cycle for electric loads could lower the cost of DAC systems compared to a solar-with-batteries baseline. The levelized cost of energy for CO2 removal (LCOECR) for DAC was reduced from $175/t-CO2 removed to as low as $66/t-CO2 removed, guiding large-scale deployment of DAC and supporting decision-making in the future.
- 10 December 2025
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 59 (50) , 27230-27243
Evaluating Thermal Efficiency and Economic Impacts in Supplying Energy Demands for Direct Air Capture
Direct air capture (DAC) technologies that remove CO2 directly from the atmosphere are needed to meet international goals of limiting the atmospheric temperature increase before 2100. Operating costs, including the cost of energy inputs, currently limit the rapid deployment of DAC systems. An abundance of untapped and abandoned geothermal resources provides an opportunity to utilize this thermal energy beneath the earth's surface to reduce the financial and energy costs of DAC. In this study, thermodynamic models of applicable renewable energy scenarios for fulfilling heating and electrical requirements of DAC were analyzed using ASPEN Plus. Individual components were optimized within the geothermal-DAC-coupled systems to quantify specific costs of implementation. The results were integrated into a technoeconomic analysis to provide a holistic perspective to optimize DAC-coupled renewable energy systems. The analysis found that scenarios using geothermal heat for CO2 desorption with either solar and batteries or an organic Rankine cycle for electric loads could lower the cost of DAC systems compared to a solar-with-batteries baseline. The levelized cost of energy for CO2 removal (LCOECR) for DAC was reduced from $175/t-CO2 removed to as low as $66/t-CO2 removed, guiding large-scale deployment of DAC and supporting decision-making in the future.
- Open Access
Operational Conditions for an Internal Combustion Engine in a SOFC-ICE Hybrid Power Generation System
Hybrid power generation systems utilizing pressurized Solid Oxide Fuel Cells (SOFCs) have gained considerable attention recently as an effective solution to the increasing demand for cleaner electricity sources. Among the various hybridization options, gas turbines (GT) and internal combustion engines (ICE) running on SOFC tail gas have been prominent. Although spark ignition (SI) tail gas engines have received less focus, they show significant potential for stationary power generation, particularly due to their ability to control combustion. This research experimentally characterized an SI engine fueled by simulated SOFC anode gas for five blends, which correspond to overall system power level and loads. The study aimed to optimize the engine operating conditions for each fuel blend and establish operational conditions that would sustain maximum performance. The results showed efficiencies as high as 31.4% at 1600 RPM, with a 17:1 compression ratio, equivalence ratio (φ) of 0.75, and a boost pressure of 165 kPa with low NOx emissions. The study also emphasizes the benefits of optimizing boost supply to minimize parasitic loads and improve brake thermal efficiency. Additionally, installing a catalytic oxidizer would enable the system to comply with new engine emission regulations. A proposed control scheme for automation includes regulating engine power by controlling the boost of the supercharger at a fixed throttle position. The results of this study help to promote the development of this SOFC-based clean energy technology.
Open AccessOperational Conditions for an Internal Combustion Engine in a SOFC-ICE Hybrid Power Generation System
Hybrid power generation systems utilizing pressurized Solid Oxide Fuel Cells (SOFCs) have gained considerable attention recently as an effective solution to the increasing demand for cleaner electricity sources. Among the various hybridization options, gas turbines (GT) and internal combustion engines (ICE) running on SOFC tail gas have been prominent. Although spark ignition (SI) tail gas engines have received less focus, they show significant potential for stationary power generation, particularly due to their ability to control combustion. This research experimentally characterized an SI engine fueled by simulated SOFC anode gas for five blends, which correspond to overall system power level and loads. The study aimed to optimize the engine operating conditions for each fuel blend and establish operational conditions that would sustain maximum performance. The results showed efficiencies as high as 31.4% at 1600 RPM, with a 17:1 compression ratio, equivalence ratio (φ) of 0.75, and a boost pressure of 165 kPa with low NOx emissions. The study also emphasizes the benefits of optimizing boost supply to minimize parasitic loads and improve brake thermal efficiency. Additionally, installing a catalytic oxidizer would enable the system to comply with new engine emission regulations. A proposed control scheme for automation includes regulating engine power by controlling the boost of the supercharger at a fixed throttle position. The results of this study help to promote the development of this SOFC-based clean energy technology.
- Open Access
- 27 January 2025
- Published by MDPI AG in Preprints.org
Operational Conditions for an Internal Combustion Engine in a SOFC-ICE Hybrid Power Generation System
Hybrid power generation systems utilizing pressurized solid oxide fuel cells (SOFC) have gained considerable attention recently as an effective solution to the increasing demand for cleaner electricity sources. Among the various hybridization options, gas turbines (GT) and internal combustion engines (ICE) running off SOFC tail gas have been prominent. Although spark ignition (SI) tail gas engines have received less focus, they show significant potential for stationary power generation, particularly due to their ability to control combustion. This research experimentally characterized an SI engine fueled by SOFC anode gas across a range of fuel cell load variations. The study aimed to optimize the engine for each fuel blend and establish operational conditions that would sustain maximum performance. The results showed efficiencies as high as 31.4% at 1600 rpm, with a 17:1 compression ratio, equivalence ratio (φ) = 0.75, and a boost pressure of 165 kPa with low NOx emissions. The study also emphasizes the benefits of optimizing boost supply to minimize parasitic loads and improve brake thermal efficiency (BTE). Additionally, installing a catalytic oxidizer would enable the system to comply with new engine emission regulations. A proposed control scheme for automation includes regulating engine power by controlling the boost of the supercharger at a fixed throttle position.
- 27 January 2025
- Published by MDPI AG in Preprints.org
Open AccessOperational Conditions for an Internal Combustion Engine in a SOFC-ICE Hybrid Power Generation System
Hybrid power generation systems utilizing pressurized solid oxide fuel cells (SOFC) have gained considerable attention recently as an effective solution to the increasing demand for cleaner electricity sources. Among the various hybridization options, gas turbines (GT) and internal combustion engines (ICE) running off SOFC tail gas have been prominent. Although spark ignition (SI) tail gas engines have received less focus, they show significant potential for stationary power generation, particularly due to their ability to control combustion. This research experimentally characterized an SI engine fueled by SOFC anode gas across a range of fuel cell load variations. The study aimed to optimize the engine for each fuel blend and establish operational conditions that would sustain maximum performance. The results showed efficiencies as high as 31.4% at 1600 rpm, with a 17:1 compression ratio, equivalence ratio (φ) = 0.75, and a boost pressure of 165 kPa with low NOx emissions. The study also emphasizes the benefits of optimizing boost supply to minimize parasitic loads and improve brake thermal efficiency (BTE). Additionally, installing a catalytic oxidizer would enable the system to comply with new engine emission regulations. A proposed control scheme for automation includes regulating engine power by controlling the boost of the supercharger at a fixed throttle position.
- 4 January 2025
- Published by Elsevier in Energy Conversion and Management
- Vol. 326
Data center sustainability: The role of flexible fuel CCHP in mitigating grid emissions and power constraints
- 4 January 2025
- Published by Elsevier in Energy Conversion and Management
- Vol. 326
Data center sustainability: The role of flexible fuel CCHP in mitigating grid emissions and power constraints
- 15 March 2024
- Published by ASME International in ASME Journal of Heat and Mass Transfer
- Vol. 146 (6) , 1-43
Experimental and Computational Investigation of Flow Boiling in a 52 μm Hydraulic Diameter Microchannel Evaporator With Inlet Restrictions and Heat Spreading
Microchannel flow boiling presents an effective thermal management strategy for high heat flux (>1 kW/cm2) devices. Fundamental mechanisms of microchannel flow boiling behaviors are difficult to determine due to macroscopic limitations of experimental hardware. In addition, flow stabilizing features of microchannel evaporators such as inlet restrictions and heat spreading further complicate fluid flow and heat transfer dynamics. Computational models, when utilized with experiments, can provide a more detailed understanding of behaviors which cannot be determined experimentally. The present study developed a computational model for flow boiling heat transfer in a 52 μm silicon microchannel evaporator designed to cool a laser diode bar, with inlet restrictions and a nonuniform heating profile at the channel level. A conjugate heat transfer model along with a coupled level set and volume of fluid (CLSVOF) model was created in ansysfluent and compared with experimental flow boiling data to gain further insights into the performance of a realistic microdevice. Heat spreading in the channel outside of the heater footprint was observed due to the high thermal conductivity of the silicon substrate. The inlet orifices impacted local flow patterns by creating a large pressure drop and forming a recirculation zone immediately downstream. This behavior resulted in pressure recovery zones and regions of separated flow boiling behavior. Bubbly, slug, and churn flows were seen to be dominant flow regimes. The heat transfer coefficient was found to be dependent on heat flux and flow regime, and more weakly on mass flux and outlet vapor quality.
- 15 March 2024
- Published by ASME International in ASME Journal of Heat and Mass Transfer
- Vol. 146 (6) , 1-43
Experimental and Computational Investigation of Flow Boiling in a 52 μm Hydraulic Diameter Microchannel Evaporator With Inlet Restrictions and Heat Spreading
Microchannel flow boiling presents an effective thermal management strategy for high heat flux (>1 kW/cm2) devices. Fundamental mechanisms of microchannel flow boiling behaviors are difficult to determine due to macroscopic limitations of experimental hardware. In addition, flow stabilizing features of microchannel evaporators such as inlet restrictions and heat spreading further complicate fluid flow and heat transfer dynamics. Computational models, when utilized with experiments, can provide a more detailed understanding of behaviors which cannot be determined experimentally. The present study developed a computational model for flow boiling heat transfer in a 52 μm silicon microchannel evaporator designed to cool a laser diode bar, with inlet restrictions and a nonuniform heating profile at the channel level. A conjugate heat transfer model along with a coupled level set and volume of fluid (CLSVOF) model was created in ansysfluent and compared with experimental flow boiling data to gain further insights into the performance of a realistic microdevice. Heat spreading in the channel outside of the heater footprint was observed due to the high thermal conductivity of the silicon substrate. The inlet orifices impacted local flow patterns by creating a large pressure drop and forming a recirculation zone immediately downstream. This behavior resulted in pressure recovery zones and regions of separated flow boiling behavior. Bubbly, slug, and churn flows were seen to be dominant flow regimes. The heat transfer coefficient was found to be dependent on heat flux and flow regime, and more weakly on mass flux and outlet vapor quality.
- 26 February 2024
- Published by Elsevier in International Journal of Greenhouse Gas Control
- Vol. 133
Economic impact of thermal energy storage on natural gas power with carbon capture in future electricity markets
- 26 February 2024
- Published by Elsevier in International Journal of Greenhouse Gas Control
- Vol. 133
Economic impact of thermal energy storage on natural gas power with carbon capture in future electricity markets
- 5 November 2021
- Published by ASME International in Journal of Electronic Packaging
- Vol. 143 (4)
Effect of Phase Change Material on Dynamic Thermal Management Performance for Power Electronics Packages
High-temperature silicon carbide (SiC) die are the most critical and expensive component in electric vehicle (EV) power electronics (PE) packages and require both active and passive methods to dissipate heat during transient operation. The use of phase change materials (PCMs) to control the peak junction temperature of the SiC die and to buffer the temperature fluctuations in the package during simulated operation is modeled here. The latent heat storage potential of multiple PCM and PCM composites is explored in both single-sided and dual-sided package configurations. The results of this study show that the addition of PCM into two different styles of PE packages is an effective method for controlling the transient junction temperatures experienced during two different drive cycles. The addition of PCM in a single-sided package also serves to decrease temperature fluctuations experienced and may be used to reduce the necessary number of SiC die required for EVs, lowering the overall material cost and volume of the package by over 50%. PCM in a single-sided package may be nearly as effective as the double-sided cooling approach of a dual-sided package in the reduction of both peak junction temperature of SiC as well as controlling temperature variations between package layers.
- 5 November 2021
- Published by ASME International in Journal of Electronic Packaging
- Vol. 143 (4)
Effect of Phase Change Material on Dynamic Thermal Management Performance for Power Electronics Packages
High-temperature silicon carbide (SiC) die are the most critical and expensive component in electric vehicle (EV) power electronics (PE) packages and require both active and passive methods to dissipate heat during transient operation. The use of phase change materials (PCMs) to control the peak junction temperature of the SiC die and to buffer the temperature fluctuations in the package during simulated operation is modeled here. The latent heat storage potential of multiple PCM and PCM composites is explored in both single-sided and dual-sided package configurations. The results of this study show that the addition of PCM into two different styles of PE packages is an effective method for controlling the transient junction temperatures experienced during two different drive cycles. The addition of PCM in a single-sided package also serves to decrease temperature fluctuations experienced and may be used to reduce the necessary number of SiC die required for EVs, lowering the overall material cost and volume of the package by over 50%. PCM in a single-sided package may be nearly as effective as the double-sided cooling approach of a dual-sided package in the reduction of both peak junction temperature of SiC as well as controlling temperature variations between package layers.
- 24 September 2021
- Published by ASME International in Journal of Electronic Packaging
- Vol. 143 (4)
Peak Temperature Mitigation of a Multimicrochannel Evaporator Under Transient Heat Loads
Microchannel flow boiling has shown great cooling potential with steady-state studies demonstrating the capability to dissipate heat fluxes over 1 kW cm−2. However, most microelectronic devices undergo transient heat loads involving cold startups or pulse-like power operation. Transient heating events in low thermal resistance, low thermal capacity cold plates may exacerbate boiling instabilities and result in device damage or failure due to local dryout conditions. Currently, limited studies are investigating these effects and potential mitigation strategies. In this study, step function, or pulsed, and ramped heat loads are investigated on a multimicrochannel silicon evaporator using R134a under a range of heat fluxes and ramping rates. The transient temperature response of the base heater is recorded using a calibrated infrared (IR) camera, while fluid flow visualization is captured using a video camera microscope. Pulsed heat loads resulted in a large temperature overshoot in the test section until the fluid reached the onset of nucleate boiling (ONB), while significant vapor backflow is observed despite the presence of channel inlet restrictions. Steady boiling is eventually reached and vapor backflow is suppressed. The magnitude of the temperature overshoot is observed to be strongly dependent on peak heat flux. In contrast, ramped heat loads resulted in lower peak temperature rises before ONB as well as significantly reduced vapor backflow compared to the pulsed heat loads.
- 24 September 2021
- Published by ASME International in Journal of Electronic Packaging
- Vol. 143 (4)
Peak Temperature Mitigation of a Multimicrochannel Evaporator Under Transient Heat Loads
Microchannel flow boiling has shown great cooling potential with steady-state studies demonstrating the capability to dissipate heat fluxes over 1 kW cm−2. However, most microelectronic devices undergo transient heat loads involving cold startups or pulse-like power operation. Transient heating events in low thermal resistance, low thermal capacity cold plates may exacerbate boiling instabilities and result in device damage or failure due to local dryout conditions. Currently, limited studies are investigating these effects and potential mitigation strategies. In this study, step function, or pulsed, and ramped heat loads are investigated on a multimicrochannel silicon evaporator using R134a under a range of heat fluxes and ramping rates. The transient temperature response of the base heater is recorded using a calibrated infrared (IR) camera, while fluid flow visualization is captured using a video camera microscope. Pulsed heat loads resulted in a large temperature overshoot in the test section until the fluid reached the onset of nucleate boiling (ONB), while significant vapor backflow is observed despite the presence of channel inlet restrictions. Steady boiling is eventually reached and vapor backflow is suppressed. The magnitude of the temperature overshoot is observed to be strongly dependent on peak heat flux. In contrast, ramped heat loads resulted in lower peak temperature rises before ONB as well as significantly reduced vapor backflow compared to the pulsed heat loads.