Yuanfei Fu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yuanfei Fu has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Demin Chen
Biomaterials Research and Test Center, Shanghai Ninth People's Hospital, Shanghai JiaoTong University, School of Medicine, College of Stomatology, Shanghai Jiao Tong University, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology, Shanghai, China
1 shared publication - Hao Gu1 shared publication
- Jiewen Dai
Foshan Stomatology Hospital, School of Stomatology and Medicine, Foshan University, Foshan, China
1 shared publication - Junlin Yang
Spine Center, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China
1 shared publication Kan Xu
1 shared publication- Liqiang Wang
State Key Laboratory of Metal Matrix Composites, School of Material Science and Engineering, Shanghai Jiao Tong University, Shanghai, China
1 shared publication
Latest Publications
- 1 May 2021
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 124, 112052
A novel and injectable strontium-containing hydroxyapatite bone cement for bone substitution: A systematic evaluation
- 1 May 2021
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 124, 112052
A novel and injectable strontium-containing hydroxyapatite bone cement for bone substitution: A systematic evaluation
- Top Cited PapersOpen Access
- 30 April 2021
- Published by AccScience Publishing in International Journal of Bioprinting
- Vol. 7 (2) , 15-42
A Review on Design and Mechanical Properties of Additively Manufactured NiTi Implants for Orthopedic Applications
NiTi alloy has a wide range of applications as a biomaterial due to its high ductility, low corrosion rate, and favorable biocompatibility. Although Young’s modulus of NiTi is relatively low, it still needs to be reduced; one of the promising ways is by introducing porous structure. Traditional manufacturing processes, such as casting, can hardly produce complex porous structures. Additive manufacturing (AM) is one of the most advanced manufacturing technologies that can solve impurity issues, and selective laser melting (SLM) is one of the well-known methods. This paper reviews the developments of AM-NiTi with a particular focus on SLM-NiTi utilization in biomedical applications. Correspondingly, this paper aims to describe the three key factors, including powder preparation, processing parameters, and gas atmosphere during the overall process of porous NiTi. The porous structure design is of vital importance, so the unit cell and pore parameters are discussed. The mechanical properties of SLM-NiTi, such as hardness, compressive strength, tensile strength, fatigue behavior, and damping properties and their relationship with design parameters are summarized. In the end, it points out the current challenges. Considering the increasing application of NiTi implants, this review paper may open new frontiers for advanced and modern designs.
- 30 April 2021
- Published by AccScience Publishing in International Journal of Bioprinting
- Vol. 7 (2) , 15-42
Top Cited PapersOpen AccessA Review on Design and Mechanical Properties of Additively Manufactured NiTi Implants for Orthopedic Applications
NiTi alloy has a wide range of applications as a biomaterial due to its high ductility, low corrosion rate, and favorable biocompatibility. Although Young’s modulus of NiTi is relatively low, it still needs to be reduced; one of the promising ways is by introducing porous structure. Traditional manufacturing processes, such as casting, can hardly produce complex porous structures. Additive manufacturing (AM) is one of the most advanced manufacturing technologies that can solve impurity issues, and selective laser melting (SLM) is one of the well-known methods. This paper reviews the developments of AM-NiTi with a particular focus on SLM-NiTi utilization in biomedical applications. Correspondingly, this paper aims to describe the three key factors, including powder preparation, processing parameters, and gas atmosphere during the overall process of porous NiTi. The porous structure design is of vital importance, so the unit cell and pore parameters are discussed. The mechanical properties of SLM-NiTi, such as hardness, compressive strength, tensile strength, fatigue behavior, and damping properties and their relationship with design parameters are summarized. In the end, it points out the current challenges. Considering the increasing application of NiTi implants, this review paper may open new frontiers for advanced and modern designs.
- Open Access
- 1 February 2019
- Published by ResearchersLinks Ltd in Pakistan Journal of Zoology
- Vol. 51 (2) , 681-687
Antibacterial Activity of Capsaicin against Sectional Cariogenic Bacteria
Antibacterial Activity of Capsaicin against Sectional Cariogenic Bacteria
- 1 February 2019
- Published by ResearchersLinks Ltd in Pakistan Journal of Zoology
- Vol. 51 (2) , 681-687
Open AccessAntibacterial Activity of Capsaicin against Sectional Cariogenic Bacteria
Antibacterial Activity of Capsaicin against Sectional Cariogenic Bacteria