Kazuaki Nagayama
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kazuaki Nagayama has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Akiko Sato
Micro-Nano Biomechanics Laboratory, Department of Mechanical Systems Engineering, Ibaraki University, 4-12-1 Nakanarusawa-cho, Hitachi, Ibaraki 316-8511, Japan
5 shared publications- Takeo Matsumoto
Biomechanics Laboratory, Department of Mechanical Systems Engineering, Graduate School of Engineering, Nagoya University, Nagoya, Japan
3 shared publications Naoki Wataya
Micro-Nano Biomechanics Laboratory, Department of Mechanical Systems Engineering, Ibaraki University, Hitachi, Japan
2 shared publicationsShota Obata
Micro-Nano Biomechanics Laboratory, Department of Mechanical Systems Engineering, Ibaraki University, Nakanarusawa-cho, Hitachi, 316-8511, Japan
2 shared publicationsTakuya Inoue
Biomechanics Laboratory, Department of Mechanical Engineering, Nagoya Institute of Technology, Gokiso-cho, Showa-ku, Nagoya, 466-8555, Japan
2 shared publicationsYasuhiro Hamada
Biomechanics Laboratory, Department of Mechanical Engineering, Nagoya Institute of Technology, Gokiso-cho, Showa-ku, Nagoya, 466-8555, Japan
2 shared publications
Latest Publications
- Open Access
- 15 April 2026
- Published by Elsevier in Mechanobiology in Medicine
- Vol. 4 (2) , 100191
Viscous drag-induced self-regeneration of laser-dissected actin stress fibers: A potential mechanism for mechanical memory
- 15 April 2026
- Published by Elsevier in Mechanobiology in Medicine
- Vol. 4 (2) , 100191
Open AccessViscous drag-induced self-regeneration of laser-dissected actin stress fibers: A potential mechanism for mechanical memory
- Open Access
- 1 January 2025
- Published by Japan Society of Mechanical Engineers in Transactions of the JSME (in Japanese)
- Vol. 91 (944) , 24-00271
Laser nanodissection for intracellular actin stress fibers and analysis of the severed fiber retraction and regeneration behavior
The intracellular actin cytoskeleton binds to non-muscle myosin II to form stress fibers (SFs) with a diameter of several hundred nanometers, which generate intracellular tension and control cell shape and movement. SFs generate a contractile force and transmit it to focal adhesions, which is essential for regulation of cell adhesion to extracellular matrix and cellular sensing of extracellular mechanical environments. Although several studies have been reported on the mechanical and contractile properties of SFs, it has not been clear how completely severed SFs are repaired and regenerated. In this study, SFs located at the periphery of living myoblasts (C2C12) were severed using a pulsed laser and their contraction and repair process were analyzed by fluorescence observation. SFs immediately contracted after their severing. The contraction process of SFs was accurately fitted using the first order lag model, indicating viscoelastic behavior. We found that SFs have a potential to repair their structures: in approximately 80% of the cells, the structure of severed SFs was gradually repaired over several minutes with contraction behavior (Repaired group), but not in some cells (Unrepaired group). The contraction rate and contraction time constant of the SFs in the unrepaired group tended to be larger than those of the repaired group. These results suggest that the repair process of the severed SFs is possibly affected by the intrinsic mechanical tension of the SFs and viscous resistance from the intracellular components around the SFs which is generated by the sliding motion caused by the fiber contraction.
- 1 January 2025
- Published by Japan Society of Mechanical Engineers in Transactions of the JSME (in Japanese)
- Vol. 91 (944) , 24-00271
Open AccessLaser nanodissection for intracellular actin stress fibers and analysis of the severed fiber retraction and regeneration behavior
The intracellular actin cytoskeleton binds to non-muscle myosin II to form stress fibers (SFs) with a diameter of several hundred nanometers, which generate intracellular tension and control cell shape and movement. SFs generate a contractile force and transmit it to focal adhesions, which is essential for regulation of cell adhesion to extracellular matrix and cellular sensing of extracellular mechanical environments. Although several studies have been reported on the mechanical and contractile properties of SFs, it has not been clear how completely severed SFs are repaired and regenerated. In this study, SFs located at the periphery of living myoblasts (C2C12) were severed using a pulsed laser and their contraction and repair process were analyzed by fluorescence observation. SFs immediately contracted after their severing. The contraction process of SFs was accurately fitted using the first order lag model, indicating viscoelastic behavior. We found that SFs have a potential to repair their structures: in approximately 80% of the cells, the structure of severed SFs was gradually repaired over several minutes with contraction behavior (Repaired group), but not in some cells (Unrepaired group). The contraction rate and contraction time constant of the SFs in the unrepaired group tended to be larger than those of the repaired group. These results suggest that the repair process of the severed SFs is possibly affected by the intrinsic mechanical tension of the SFs and viscous resistance from the intracellular components around the SFs which is generated by the sliding motion caused by the fiber contraction.
- Open Access
- 1 January 2025
- Published by Japanese Society for Medical and Biological Engineering in Advanced Biomedical Engineering
- Vol. 14, 70-78
Atomic Force Microscopy Estimation of Mechanical Properties of Tunneling Nanotubes in Cancer Cells
Intercellular communication is mediated by fibrous structures known as tunneling nanotubes (TNTs). TNTs are present in diseased cells, including cancer cells, and facilitate the transport of intracellular substances crucial for cell survival. They contribute to cancer survival by enhancing metastatic and invasive abilities and are implicated in the drug resistance of cancer cells. However, previous studies have primarily focused on the biochemical signaling of TNTs, and their mechanical properties are largely unknown. We hypothesized that TNTs play a mechanical role in cell survival by regulating cell-cell distance, migration direction, and mechanical signaling between cells. In this study, we investigated the mechanical properties of TNTs in a human cervical cancer cell line, HeLa cells, through nanoindentation tests using atomic force microscopy (AFM). To minimize shape variation in the TNTs and enhance the efficiency of mechanical tests, the shape of the cells and the distance between neighboring cells were controlled using a microcontact printing method that regulates cell adhesion regions. By performing AFM indentation tests on the TNTs, we determined that their internal tension was 758.3 ± 372.5 pN, axial spring constant was 32.1 ± 14.2 pN/µm, and axial elastic modulus was 696.3 ± 578.0 kPa. Furthermore, we observed that the internal tension and axial elastic modulus correlated positively with TNT length, while the axial elastic modulus correlated negatively with TNT thickness; that is, the thinner and longer the TNTs, the stiffer and higher are their tension. This implies that longer TNTs can exert greater tension on neighboring cells, thereby facilitating the proliferation of cancer cells. These findings suggest that TNTs play a critical role in the mechanical communication of cancer cells and may influence various aspects of cell survival, significantly affecting the progression of cancer and other diseases.
- 1 January 2025
- Published by Japanese Society for Medical and Biological Engineering in Advanced Biomedical Engineering
- Vol. 14, 70-78
Open AccessAtomic Force Microscopy Estimation of Mechanical Properties of Tunneling Nanotubes in Cancer Cells
Intercellular communication is mediated by fibrous structures known as tunneling nanotubes (TNTs). TNTs are present in diseased cells, including cancer cells, and facilitate the transport of intracellular substances crucial for cell survival. They contribute to cancer survival by enhancing metastatic and invasive abilities and are implicated in the drug resistance of cancer cells. However, previous studies have primarily focused on the biochemical signaling of TNTs, and their mechanical properties are largely unknown. We hypothesized that TNTs play a mechanical role in cell survival by regulating cell-cell distance, migration direction, and mechanical signaling between cells. In this study, we investigated the mechanical properties of TNTs in a human cervical cancer cell line, HeLa cells, through nanoindentation tests using atomic force microscopy (AFM). To minimize shape variation in the TNTs and enhance the efficiency of mechanical tests, the shape of the cells and the distance between neighboring cells were controlled using a microcontact printing method that regulates cell adhesion regions. By performing AFM indentation tests on the TNTs, we determined that their internal tension was 758.3 ± 372.5 pN, axial spring constant was 32.1 ± 14.2 pN/µm, and axial elastic modulus was 696.3 ± 578.0 kPa. Furthermore, we observed that the internal tension and axial elastic modulus correlated positively with TNT length, while the axial elastic modulus correlated negatively with TNT thickness; that is, the thinner and longer the TNTs, the stiffer and higher are their tension. This implies that longer TNTs can exert greater tension on neighboring cells, thereby facilitating the proliferation of cancer cells. These findings suggest that TNTs play a critical role in the mechanical communication of cancer cells and may influence various aspects of cell survival, significantly affecting the progression of cancer and other diseases.
- 22 October 2024
- Published by Springer Nature in Cellular and Molecular Bioengineering
- Vol. 17 (6) , 549-562
Mechanical Trapping of the Cell Nucleus Into Microgroove Concavity But Not On Convexity Induces Cell Tissue Growth and Vascular Smooth Muscle Differentiation
Introduction Vascular smooth muscle cells (VSMCs) in the normal aortic wall regulate vascular contraction and dilation. VSMCs change their phenotype from contractile to synthetic and actively remodel the aortic wall under pathological conditions. Findings on the differentiation mechanism of VSMCs have been reported in many in vitro studies; however, the mechanical environments in vivo aortic walls are quite different from those of in vitro culture conditions: VSMCs in vivo exhibit an elongated shape and form a tissue that aligns with the circumferential direction of the walls, whereas VSMCs in vitro spread randomly and form irregular shapes during cultivation on conventional flat culture dishes and dedifferentiate into a synthetic phenotype. To clarify the mechanisms underlying the VSMC differentiation, it is essential to develop a cell culture model that considers the mechanical environment of in vivo aortic walls. Methods We fabricated a polydimethylsiloxane-based microgrooved substrate with 5, 10, and 20 μm of groove width and 5 μm of groove depth to induce VSMC elongation and alignment as observed in vivo. We established a coating method to control cell adhesion proteins only on the surface of groove concavities and investigated the effects of mechanical trapping of the cell nucleus in microgroove concavities on the morphology of intracellular nuclei, cell proliferation and motility, and VSMC differentiation. Results We found that VSMCs adhering to the concavities formed a uniform cell tissue and allowed remarkable elongation. In particular, the microgrooves with 5 μm of groove width and depth facilitated a significant nuclear deformation and volume reduction of the nucleus due to a lateral compression by the side wall of the groove concavities that is relatively similar to a sandwich-like arrangement of in vivo elastic lamellae, resulting in the drastic inhibition of cell motility and proliferation, and the significant improvement of VSMC differentiation. Conclusions The results indicate that mechanical trapping of the cell nucleus into microgroove concavity but not on convexity induces cell tissue growth and VSMC differentiation. Our cell culture model with microgrooved substrates can be useful for studying the mechanisms of VSMC differentiation, considering the in vivo vascular mechanical environment.
- 22 October 2024
- Published by Springer Nature in Cellular and Molecular Bioengineering
- Vol. 17 (6) , 549-562
Mechanical Trapping of the Cell Nucleus Into Microgroove Concavity But Not On Convexity Induces Cell Tissue Growth and Vascular Smooth Muscle Differentiation
Introduction Vascular smooth muscle cells (VSMCs) in the normal aortic wall regulate vascular contraction and dilation. VSMCs change their phenotype from contractile to synthetic and actively remodel the aortic wall under pathological conditions. Findings on the differentiation mechanism of VSMCs have been reported in many in vitro studies; however, the mechanical environments in vivo aortic walls are quite different from those of in vitro culture conditions: VSMCs in vivo exhibit an elongated shape and form a tissue that aligns with the circumferential direction of the walls, whereas VSMCs in vitro spread randomly and form irregular shapes during cultivation on conventional flat culture dishes and dedifferentiate into a synthetic phenotype. To clarify the mechanisms underlying the VSMC differentiation, it is essential to develop a cell culture model that considers the mechanical environment of in vivo aortic walls. Methods We fabricated a polydimethylsiloxane-based microgrooved substrate with 5, 10, and 20 μm of groove width and 5 μm of groove depth to induce VSMC elongation and alignment as observed in vivo. We established a coating method to control cell adhesion proteins only on the surface of groove concavities and investigated the effects of mechanical trapping of the cell nucleus in microgroove concavities on the morphology of intracellular nuclei, cell proliferation and motility, and VSMC differentiation. Results We found that VSMCs adhering to the concavities formed a uniform cell tissue and allowed remarkable elongation. In particular, the microgrooves with 5 μm of groove width and depth facilitated a significant nuclear deformation and volume reduction of the nucleus due to a lateral compression by the side wall of the groove concavities that is relatively similar to a sandwich-like arrangement of in vivo elastic lamellae, resulting in the drastic inhibition of cell motility and proliferation, and the significant improvement of VSMC differentiation. Conclusions The results indicate that mechanical trapping of the cell nucleus into microgroove concavity but not on convexity induces cell tissue growth and VSMC differentiation. Our cell culture model with microgrooved substrates can be useful for studying the mechanisms of VSMC differentiation, considering the in vivo vascular mechanical environment.
- 17 September 2024
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 160, 106744
Dedifferentiation- and aging-induced loss of mechanical contractility and polarity in vascular smooth muscle cells: Heterogeneous changes in macroscopic and microscopic behavior of cells in serial passage culture
- 17 September 2024
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 160, 106744
Dedifferentiation- and aging-induced loss of mechanical contractility and polarity in vascular smooth muscle cells: Heterogeneous changes in macroscopic and microscopic behavior of cells in serial passage culture
- Open Access
- 1 January 2024
- Published by Japan Society of Mechanical Engineers in Transactions of the JSME (in Japanese)
- Vol. 90 (939) , 24-00180
Extraction and evaluation of cell nuclei images in label-free phase contrast microscopy enabled by machine learning using a data analysis platform Usiigaci
Recently, machine learning has been applied as a powerful tool for determining cell functions and states from cell shape features in microscopic images. However, it has not been fully investigated how changes in the microscopic observation environments and differences in cell types affect the accuracy of cell detection by machine learning. In addition to cell shapes, changes in intracellular structure are also considered important information in determining the cell functions. In particular, the shape of the cell nucleus is expected to be an indicator for disease diagnosis. In this study, we established a method for detecting the cell nuclear regions in phase contrast (PC) microscope images of unstained cells using Usiigaci (Tsai et al., 2019), an image machine learning platform consisting of Mask R-CNN. From a practical point of view, we investigated how the effects of out-of-focus state of the microscope and the cell type differences on the accuracy of nuclear region detection in PC microscope images. It was found that the accuracy of the nucleus segmentation was significantly influenced by the contrast (brightness gradient) of the captured images, and that an image taken at least within the depth of focus of the observation system is necessary for the accurate nucleus segmentation. Furthermore, the nucleus segmentation is easily affected by differences in cell morphology and intracellular structures such as the cytoskeletons, and the accuracy of the nucleus segmentation is less than half for vascular smooth muscle cells compared to NIH3T3 fibroblast cell lines. Therefore, compared to conventional segmentation for cell outlines, the nucleus segmentation using label-free PC microscope images is extremely difficult, and these are important issues that cannot be ignored in the practical application of machine learning of cell microscopic images.
- 1 January 2024
- Published by Japan Society of Mechanical Engineers in Transactions of the JSME (in Japanese)
- Vol. 90 (939) , 24-00180
Open AccessExtraction and evaluation of cell nuclei images in label-free phase contrast microscopy enabled by machine learning using a data analysis platform Usiigaci
Recently, machine learning has been applied as a powerful tool for determining cell functions and states from cell shape features in microscopic images. However, it has not been fully investigated how changes in the microscopic observation environments and differences in cell types affect the accuracy of cell detection by machine learning. In addition to cell shapes, changes in intracellular structure are also considered important information in determining the cell functions. In particular, the shape of the cell nucleus is expected to be an indicator for disease diagnosis. In this study, we established a method for detecting the cell nuclear regions in phase contrast (PC) microscope images of unstained cells using Usiigaci (Tsai et al., 2019), an image machine learning platform consisting of Mask R-CNN. From a practical point of view, we investigated how the effects of out-of-focus state of the microscope and the cell type differences on the accuracy of nuclear region detection in PC microscope images. It was found that the accuracy of the nucleus segmentation was significantly influenced by the contrast (brightness gradient) of the captured images, and that an image taken at least within the depth of focus of the observation system is necessary for the accurate nucleus segmentation. Furthermore, the nucleus segmentation is easily affected by differences in cell morphology and intracellular structures such as the cytoskeletons, and the accuracy of the nucleus segmentation is less than half for vascular smooth muscle cells compared to NIH3T3 fibroblast cell lines. Therefore, compared to conventional segmentation for cell outlines, the nucleus segmentation using label-free PC microscope images is extremely difficult, and these are important issues that cannot be ignored in the practical application of machine learning of cell microscopic images.
- Open Access
- 20 October 2023
- Published by Fuji Technology Press Ltd. in Journal of Robotics and Mechatronics
- Vol. 35 (5) , 1158-1164
Deformation and Trapping of Cell Nucleus Using Micropillar Substrates Possibly Affect UV Radiation Resistance of DNA
DNA damage induced by the ultraviolet (UV) light, which affects adversely on genome stability, causes many kinds of diseases. Thus, a biochemical or biomechanical method in DNA damage protection is well required. In the present study, we investigated the effects of mechanical factors, such as deformation of cell nucleus using polydimethylsiloxane (PDMS)-based microfabricated array of micropillars, on UV radiation resistance of DNA in cultured cells. The epithelial-like cells spread normally in the spaces between micropillars and their nuclei showed remarkable deformation and appeared to be “trapped” mechanically on the array of pillars. We found that the UV radiation-induced DNA damage estimated by the fluorescent intensity of the phospho-histone γ-H2AX, was significantly inhibited with the nucleus deformation on the pillars. The result indicates that the inhibition of UV radiation-induced DNA damages might be resulted from structural change of DNA caused by the mechanical stress of the cell nucleus on the micropillars.
- 20 October 2023
- Published by Fuji Technology Press Ltd. in Journal of Robotics and Mechatronics
- Vol. 35 (5) , 1158-1164
Open AccessDeformation and Trapping of Cell Nucleus Using Micropillar Substrates Possibly Affect UV Radiation Resistance of DNA
DNA damage induced by the ultraviolet (UV) light, which affects adversely on genome stability, causes many kinds of diseases. Thus, a biochemical or biomechanical method in DNA damage protection is well required. In the present study, we investigated the effects of mechanical factors, such as deformation of cell nucleus using polydimethylsiloxane (PDMS)-based microfabricated array of micropillars, on UV radiation resistance of DNA in cultured cells. The epithelial-like cells spread normally in the spaces between micropillars and their nuclei showed remarkable deformation and appeared to be “trapped” mechanically on the array of pillars. We found that the UV radiation-induced DNA damage estimated by the fluorescent intensity of the phospho-histone γ-H2AX, was significantly inhibited with the nucleus deformation on the pillars. The result indicates that the inhibition of UV radiation-induced DNA damages might be resulted from structural change of DNA caused by the mechanical stress of the cell nucleus on the micropillars.
- Open Access
- 1 January 2023
- Published by Japan Society of Mechanical Engineers in Journal of Biomechanical Science and Engineering
- Vol. 18 (3) , 22-00474
Superficial groove structure in the size of focal adhesion can clarify cell-type-specific differences in force-dependent substrate mechanosensing
Mechanosensing-based cell orientation and migration in microenvironments, such as microgrooved surfaces, are essential in biological tissue growth and repair. These responses might be cell type-dependent as they are deeply involved in cellular functions. Despite their orientation and migration responses are depended on cell-substrate adhesion, which is deeply involved with focal adhesions (FAs) of cells, we have limited information on the cell behavior on FA-sized microgrooved surfaces. Here, we systematically investigated the cell orientation and migration behavior of primary porcine aortic smooth muscle cells (PASMs), embryonic rat aortic smooth muscle cells with fibroblast-like phenotype (A7r5), and human cervical cancer cells (HeLa) on a substrate comprised of superficial grooves with three widths (1 μm, 5 μm, and 10 μm) and 150-nm depth, which are the same order of magnitude of the three-dimensional size of FAs. PASM and A7r5 cells including thick bundles of actin fibers with elongated FAs showed pronounced cell polarization and directional migration on the 1 and 5 μm wide grooves. PASMs were more sensitive to the superficial grooves than A7r5 cells. HeLa cells adhering to the grooves had non-oriented actin fibers with smaller FAs, and they did not show specific orientation nor directional migration in any groove type. Atomic force microscopy elucidated that the mechanical tension of the actin fibers in live cells had a significant positive correlation with the length/width ratio of FAs, reflecting the cell alignment and directional migration on the grooves. The increase or decrease in the mechanical tension of the actin fibers improved or diminished the mechanosensing for the grooves, respectively. The results strongly suggested that the differences in cell type-specific alignment and migration become much more pronounced on the microgrooves which are similar in three-dimensional size of FA, and that is useful for clarifying slight differences in force-dependent cellular mechanosensing.
- 1 January 2023
- Published by Japan Society of Mechanical Engineers in Journal of Biomechanical Science and Engineering
- Vol. 18 (3) , 22-00474
Open AccessSuperficial groove structure in the size of focal adhesion can clarify cell-type-specific differences in force-dependent substrate mechanosensing
Mechanosensing-based cell orientation and migration in microenvironments, such as microgrooved surfaces, are essential in biological tissue growth and repair. These responses might be cell type-dependent as they are deeply involved in cellular functions. Despite their orientation and migration responses are depended on cell-substrate adhesion, which is deeply involved with focal adhesions (FAs) of cells, we have limited information on the cell behavior on FA-sized microgrooved surfaces. Here, we systematically investigated the cell orientation and migration behavior of primary porcine aortic smooth muscle cells (PASMs), embryonic rat aortic smooth muscle cells with fibroblast-like phenotype (A7r5), and human cervical cancer cells (HeLa) on a substrate comprised of superficial grooves with three widths (1 μm, 5 μm, and 10 μm) and 150-nm depth, which are the same order of magnitude of the three-dimensional size of FAs. PASM and A7r5 cells including thick bundles of actin fibers with elongated FAs showed pronounced cell polarization and directional migration on the 1 and 5 μm wide grooves. PASMs were more sensitive to the superficial grooves than A7r5 cells. HeLa cells adhering to the grooves had non-oriented actin fibers with smaller FAs, and they did not show specific orientation nor directional migration in any groove type. Atomic force microscopy elucidated that the mechanical tension of the actin fibers in live cells had a significant positive correlation with the length/width ratio of FAs, reflecting the cell alignment and directional migration on the grooves. The increase or decrease in the mechanical tension of the actin fibers improved or diminished the mechanosensing for the grooves, respectively. The results strongly suggested that the differences in cell type-specific alignment and migration become much more pronounced on the microgrooves which are similar in three-dimensional size of FA, and that is useful for clarifying slight differences in force-dependent cellular mechanosensing.
- 20 December 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 138, 105630
Changes in the intra- and extra-mechanical environment of the nucleus in Saos-2 osteoblastic cells during bone differentiation process: Nuclear shrinkage and stiffening in cell differentiation
- 20 December 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 138, 105630
Changes in the intra- and extra-mechanical environment of the nucleus in Saos-2 osteoblastic cells during bone differentiation process: Nuclear shrinkage and stiffening in cell differentiation