Thierry L. Lefebvre
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Thierry L. Lefebvre has a total of 110 co-authors. Here are the top co-authors by number of shared publications:
- An Tang
Department of Radiology, Centre Hospitalier de l’Université de Montréal (CHUM), Montreal, Canada
4 shared publications Giada Sebastiani
Department of Medicine, Division of Gastroenterology and Hepatology, McGill University Health Centre (MUHC) , Montréal, Québec, H4A 0B1
4 shared publicationsGuillaume Gilbert
Department of Radiology, Radiation Oncology and Nuclear Medicine, Université de Montréal , Montréal, Québec, H3T 1J4
4 shared publicationsGuy Cloutier
Department of Radiology, Radiation Oncology and Nuclear Medicine, Université de Montréal , Montréal, Québec, H3T 1J4
4 shared publications- Sarah Elizabeth Bohndiek
Cancer Research UK Cambridge Institute (United Kingdom)
4 shared publications Bich N. Nguyen
Service of Pathology, Centre hospitalier de l’Université de Montréal (CHUM), Montréal, Canada
3 shared publications
Latest Publications
- Open Access
- 9 March 2026
- Published by Wiley in Advanced Science
- Vol. 13 (26) , e09268
Early Radiation Therapy Response Assessment Using Multi‐Scale Photoacoustic Imaging
There is a critical unmet clinical need to identify biomarkers that predict and detect radiation therapy (RT) response in cancer. Using the unique capabilities of multi‐scale photoacoustic imaging (PAI) to depict tumor oxygenation and vasculature in vivo, we identified surrogate biomarkers of RT response in two human breast cancer xenograft models (MCF7 and MDA‐MB‐231), comparing hypofractionated delivery with an ablative single‐dose scheme. Mesoscopic and multispectral tomographic PAI were performed 24h pre‐RT, 24h post‐RT and at endpoint and were supported by ex vivo immunohistochemistry. MCF7 xenografts, which exhibited a denser and more mature vasculature, showed improved response to both RT schemes than MDA‐MB‐231, in terms of oxygenation, volume control and proliferation. Higher pre‐RT oxygenation and oxygen‐diffusion capacity were associated with improved outcome, consistent with the oxygen‐enhancement effect. PAI further revealed regimen‐specific vascular effects: ablative RT produced early pruning of looping vessels and superficial blood volume, while only hypofractionated RT led to a rise in intratumoral oxygenation at the endpoint in radiosensitive MCF7, indicative of reduced oxygen consumption in damaged tumor cells. We showed that PAI could capture early RT response and inform on radioresistance, thus demonstrating PAI as a promising tool to monitor the tumor vascular response to RT.
- 9 March 2026
- Published by Wiley in Advanced Science
- Vol. 13 (26) , e09268
Open AccessEarly Radiation Therapy Response Assessment Using Multi‐Scale Photoacoustic Imaging
There is a critical unmet clinical need to identify biomarkers that predict and detect radiation therapy (RT) response in cancer. Using the unique capabilities of multi‐scale photoacoustic imaging (PAI) to depict tumor oxygenation and vasculature in vivo, we identified surrogate biomarkers of RT response in two human breast cancer xenograft models (MCF7 and MDA‐MB‐231), comparing hypofractionated delivery with an ablative single‐dose scheme. Mesoscopic and multispectral tomographic PAI were performed 24h pre‐RT, 24h post‐RT and at endpoint and were supported by ex vivo immunohistochemistry. MCF7 xenografts, which exhibited a denser and more mature vasculature, showed improved response to both RT schemes than MDA‐MB‐231, in terms of oxygenation, volume control and proliferation. Higher pre‐RT oxygenation and oxygen‐diffusion capacity were associated with improved outcome, consistent with the oxygen‐enhancement effect. PAI further revealed regimen‐specific vascular effects: ablative RT produced early pruning of looping vessels and superficial blood volume, while only hypofractionated RT led to a rise in intratumoral oxygenation at the endpoint in radiosensitive MCF7, indicative of reduced oxygen consumption in damaged tumor cells. We showed that PAI could capture early RT response and inform on radioresistance, thus demonstrating PAI as a promising tool to monitor the tumor vascular response to RT.
- Open Access
- 13 October 2025
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 98 (1176) , 2066-2071
Harnessing intrinsic cardiac motion vs. external mechanical vibrations: a comparison of MRI cine-tagging and MR elastography for liver fibrosis assessment
Objective: This study aims to assess and compare the diagnostic accuracy of MRI cine-tagging and magnetic resonance elastography (MRE) for staging histologically confirmed liver fibrosis in patients with chronic liver disease. Methods: MRI cine-tagging evaluates liver strain as the deformation induced by intrinsic cardiac motion on the left liver lobe, whereas MRE captures liver stiffness in response to externally applied vibrations from a mechanical driver. A head-to-head comparison of MRI cine-tagging and MRE was performed in 76 participants with biopsy-proven chronic liver disease. Spearman’s rank correlation coefficients and areas under the receiver operating characteristic curve (AUC) were assessed. AUCs were compared using the Delong method. Results: MRE-derived shear modulus increased, while strain obtained from tagged cine MRI decreased with higher fibrosis stages (ρ = 0.73 and ρ = −0.67, respectively; P < .0001). Both shear modulus and strain values exhibited significant differences across fibrosis stages (P < .0001) and correlated with each other (ρ = −0.44, P < .0001). MRE provided higher AUCs than MRI cine-tagging only for distinguishing stages ≤F3 vs. F4 (0.91 vs. 0.87, P = .043). There were no significant differences in AUCs for differentiating other dichotomized fibrosis stages, including stages F0 vs. ≥F1 (0.87 vs. 0.81, P = .083), ≤F1 vs. ≥F2 (0.84 vs. 0.84, P = .889), and ≤F2 vs. ≥F3 (0.89 vs. 0.86, P = .116). Conclusion: MRI cine-tagging provided a similar diagnostic performance compared to MRE for staging liver fibrosis, except for the diagnosis of cirrhosis (F4). It is possible to assess liver strain as part of abdominal MRI screening, offering additional insight into the left lobe without the need for additional equipment. Advances in knowledge: A head-to-head comparison of magnetic resonance elastography (MRE), the most accurate technique for the noninvasive staging of liver fibrosis, and MRI cine-tagging has not been performed yet. We found that MRI cine-tagging, having the advantage of not requiring any additional hardware, provides a similar diagnostic performance compared to MRE for staging liver fibrosis, except for the diagnosis of cirrhosis in patients with chronic liver disease.
- 13 October 2025
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 98 (1176) , 2066-2071
Open AccessHarnessing intrinsic cardiac motion vs. external mechanical vibrations: a comparison of MRI cine-tagging and MR elastography for liver fibrosis assessment
Objective: This study aims to assess and compare the diagnostic accuracy of MRI cine-tagging and magnetic resonance elastography (MRE) for staging histologically confirmed liver fibrosis in patients with chronic liver disease. Methods: MRI cine-tagging evaluates liver strain as the deformation induced by intrinsic cardiac motion on the left liver lobe, whereas MRE captures liver stiffness in response to externally applied vibrations from a mechanical driver. A head-to-head comparison of MRI cine-tagging and MRE was performed in 76 participants with biopsy-proven chronic liver disease. Spearman’s rank correlation coefficients and areas under the receiver operating characteristic curve (AUC) were assessed. AUCs were compared using the Delong method. Results: MRE-derived shear modulus increased, while strain obtained from tagged cine MRI decreased with higher fibrosis stages (ρ = 0.73 and ρ = −0.67, respectively; P < .0001). Both shear modulus and strain values exhibited significant differences across fibrosis stages (P < .0001) and correlated with each other (ρ = −0.44, P < .0001). MRE provided higher AUCs than MRI cine-tagging only for distinguishing stages ≤F3 vs. F4 (0.91 vs. 0.87, P = .043). There were no significant differences in AUCs for differentiating other dichotomized fibrosis stages, including stages F0 vs. ≥F1 (0.87 vs. 0.81, P = .083), ≤F1 vs. ≥F2 (0.84 vs. 0.84, P = .889), and ≤F2 vs. ≥F3 (0.89 vs. 0.86, P = .116). Conclusion: MRI cine-tagging provided a similar diagnostic performance compared to MRE for staging liver fibrosis, except for the diagnosis of cirrhosis (F4). It is possible to assess liver strain as part of abdominal MRI screening, offering additional insight into the left lobe without the need for additional equipment. Advances in knowledge: A head-to-head comparison of magnetic resonance elastography (MRE), the most accurate technique for the noninvasive staging of liver fibrosis, and MRI cine-tagging has not been performed yet. We found that MRI cine-tagging, having the advantage of not requiring any additional hardware, provides a similar diagnostic performance compared to MRE for staging liver fibrosis, except for the diagnosis of cirrhosis in patients with chronic liver disease.
- Open Access
- 29 April 2025
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 11 (3) , 037004
A survey of dosimetry quality assurance practice at UK small animal radiation research platform (SARRP) facilities
Introduction: Improvements in preclinical radiation research have been made to better mimic the equipment and techniques implemented in the clinic. The development of dedicated small animal radiation units facilitates such advances by combining treatment planning, image guidance and conformal delivery. One area significantly behind its clinical equivalent are standardised dosimetry quality assurance (QA) protocols, hampering the translatability of results into the development of clinical interventions. Approach: The aim of the study described herein was to summarise the current QA procedures implemented at several institutions on Small Animal Radiation Research Platforms (SARRPs), the system used by the six institutions surveyed, and to determine the barriers to implementing a standard dosimetry protocol. Participants at UK research institutions were invited to complete a questionnaire to ascertain their current preclinical QA practice. Main results: All participants involved undertake regular dose output measurements and most perform image guidance QA measurements. Consistency in QA procedures differed when more complex plan verification or end-to-end testing was discussed. Significance: This survey demonstrates that, although improvements are being made in the awareness of the importance of regular dosimetry tests, there is still a way to go to standardise the procedures with regards to more complex verifications. Incorporating robust QA procedures and strict dose constraints would ensure the reliability and ethical integrity of experiments involving small animals. This approach not only protects the welfare of the animals but also enhances the quality and reproducibility of the preclinical results.
- 29 April 2025
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 11 (3) , 037004
Open AccessA survey of dosimetry quality assurance practice at UK small animal radiation research platform (SARRP) facilities
Introduction: Improvements in preclinical radiation research have been made to better mimic the equipment and techniques implemented in the clinic. The development of dedicated small animal radiation units facilitates such advances by combining treatment planning, image guidance and conformal delivery. One area significantly behind its clinical equivalent are standardised dosimetry quality assurance (QA) protocols, hampering the translatability of results into the development of clinical interventions. Approach: The aim of the study described herein was to summarise the current QA procedures implemented at several institutions on Small Animal Radiation Research Platforms (SARRPs), the system used by the six institutions surveyed, and to determine the barriers to implementing a standard dosimetry protocol. Participants at UK research institutions were invited to complete a questionnaire to ascertain their current preclinical QA practice. Main results: All participants involved undertake regular dose output measurements and most perform image guidance QA measurements. Consistency in QA procedures differed when more complex plan verification or end-to-end testing was discussed. Significance: This survey demonstrates that, although improvements are being made in the awareness of the importance of regular dosimetry tests, there is still a way to go to standardise the procedures with regards to more complex verifications. Incorporating robust QA procedures and strict dose constraints would ensure the reliability and ethical integrity of experiments involving small animals. This approach not only protects the welfare of the animals but also enhances the quality and reproducibility of the preclinical results.
- Open Access
- 17 October 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (21) , 215007
Performance evaluation of image co-registration methods in photoacoustic mesoscopy of the vasculature
Objective. The formation of functional vasculature in solid tumours enables delivery of oxygen and nutrients, and is vital for effective treatment with chemotherapeutic agents. Longitudinal characterisation of vascular networks can be enabled using mesoscopic photoacoustic imaging, but requires accurate image co-registration to precisely assess local changes across disease development or in response to therapy. Co-registration in photoacoustic imaging is challenging due to the complex nature of the generated signal, including the sparsity of data, artefacts related to the illumination/detection geometry, scan-to-scan technical variability, and biological variability, such as transient changes in perfusion. To better inform the choice of co-registration algorithms, we compared five open-source methods, in physiological and pathological tissues, with the aim of aligning evolving vascular networks in tumours imaged over growth at different time-points. Approach. Co-registration techniques were applied to 3D vascular images acquired with photoacoustic mesoscopy from murine ears and breast cancer patient-derived xenografts, at a fixed time-point and longitudinally. Images were pre-processed and segmented using an unsupervised generative adversarial network. To compare co-registration quality in different settings, pairs of fixed and moving intensity images and/or segmentations were fed into five methods split into the following categories: affine intensity-based using (1) mutual information (MI) or (2) normalised cross-correlation (NCC) as optimisation metrics, affine shape-based using (3) NCC applied to distance-transformed segmentations or (4) iterative closest point algorithm, and deformable weakly supervised deep learning-based using (5) LocalNet co-registration. Percent-changes in Dice coefficients, surface distances, MI, structural similarity index measure and target registration errors were evaluated. Main results. Co-registration using MI or NCC provided similar alignment performance, better than shape-based methods. LocalNet provided accurate co-registration of substructures by optimising subfield deformation throughout the volumes, outperforming other methods, especially in the longitudinal breast cancer xenograft dataset by minimising target registration errors. Significance. We showed the feasibility of co-registering repeatedly or longitudinally imaged vascular networks in photoacoustic mesoscopy, taking a step towards longitudinal quantitative characterisation of these complex structures. These tools open new outlooks for monitoring tumour angiogenesis at the meso-scale and for quantifying treatment-induced co-localised alterations in the vasculature.
- 17 October 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (21) , 215007
Open AccessPerformance evaluation of image co-registration methods in photoacoustic mesoscopy of the vasculature
Objective. The formation of functional vasculature in solid tumours enables delivery of oxygen and nutrients, and is vital for effective treatment with chemotherapeutic agents. Longitudinal characterisation of vascular networks can be enabled using mesoscopic photoacoustic imaging, but requires accurate image co-registration to precisely assess local changes across disease development or in response to therapy. Co-registration in photoacoustic imaging is challenging due to the complex nature of the generated signal, including the sparsity of data, artefacts related to the illumination/detection geometry, scan-to-scan technical variability, and biological variability, such as transient changes in perfusion. To better inform the choice of co-registration algorithms, we compared five open-source methods, in physiological and pathological tissues, with the aim of aligning evolving vascular networks in tumours imaged over growth at different time-points. Approach. Co-registration techniques were applied to 3D vascular images acquired with photoacoustic mesoscopy from murine ears and breast cancer patient-derived xenografts, at a fixed time-point and longitudinally. Images were pre-processed and segmented using an unsupervised generative adversarial network. To compare co-registration quality in different settings, pairs of fixed and moving intensity images and/or segmentations were fed into five methods split into the following categories: affine intensity-based using (1) mutual information (MI) or (2) normalised cross-correlation (NCC) as optimisation metrics, affine shape-based using (3) NCC applied to distance-transformed segmentations or (4) iterative closest point algorithm, and deformable weakly supervised deep learning-based using (5) LocalNet co-registration. Percent-changes in Dice coefficients, surface distances, MI, structural similarity index measure and target registration errors were evaluated. Main results. Co-registration using MI or NCC provided similar alignment performance, better than shape-based methods. LocalNet provided accurate co-registration of substructures by optimising subfield deformation throughout the volumes, outperforming other methods, especially in the longitudinal breast cancer xenograft dataset by minimising target registration errors. Significance. We showed the feasibility of co-registering repeatedly or longitudinally imaged vascular networks in photoacoustic mesoscopy, taking a step towards longitudinal quantitative characterisation of these complex structures. These tools open new outlooks for monitoring tumour angiogenesis at the meso-scale and for quantifying treatment-induced co-localised alterations in the vasculature.
- Open Access
- 23 June 2024
- Published by Wiley in Advanced Science
- Vol. 11 (32) , e2402195
Unsupervised Segmentation of 3D Microvascular Photoacoustic Images Using Deep Generative Learning
Mesoscopic photoacoustic imaging (PAI) enables label‐free visualization of vascular networks in tissues with high contrast and resolution. Segmenting these networks from 3D PAI data and interpreting their physiological and pathological significance is crucial yet challenging due to the time‐consuming and error‐prone nature of current methods. Deep learning offers a potential solution; however, supervised analysis frameworks typically require human‐annotated ground‐truth labels. To address this, an unsupervised image‐to‐image translation deep learning model is introduced, the Vessel Segmentation Generative Adversarial Network (VAN‐GAN). VAN‐GAN integrates synthetic blood vessel networks that closely resemble real‐life anatomy into its training process and learns to replicate the underlying physics of the PAI system in order to learn how to segment vasculature from 3D photoacoustic images. Applied to a diverse range of in silico, in vitro, and in vivo data, including patient‐derived breast cancer xenograft models and 3D clinical angiograms, VAN‐GAN demonstrates its capability to facilitate accurate and unbiased segmentation of 3D vascular networks. By leveraging synthetic data, VAN‐GAN reduces the reliance on manual labeling, thus lowering the barrier to entry for high‐quality blood vessel segmentation (F1 score: VAN‐GAN vs. U‐Net = 0.84 vs. 0.87) and enhancing preclinical and clinical research into vascular structure and function.
- 23 June 2024
- Published by Wiley in Advanced Science
- Vol. 11 (32) , e2402195
Open AccessUnsupervised Segmentation of 3D Microvascular Photoacoustic Images Using Deep Generative Learning
Mesoscopic photoacoustic imaging (PAI) enables label‐free visualization of vascular networks in tissues with high contrast and resolution. Segmenting these networks from 3D PAI data and interpreting their physiological and pathological significance is crucial yet challenging due to the time‐consuming and error‐prone nature of current methods. Deep learning offers a potential solution; however, supervised analysis frameworks typically require human‐annotated ground‐truth labels. To address this, an unsupervised image‐to‐image translation deep learning model is introduced, the Vessel Segmentation Generative Adversarial Network (VAN‐GAN). VAN‐GAN integrates synthetic blood vessel networks that closely resemble real‐life anatomy into its training process and learns to replicate the underlying physics of the PAI system in order to learn how to segment vasculature from 3D photoacoustic images. Applied to a diverse range of in silico, in vitro, and in vivo data, including patient‐derived breast cancer xenograft models and 3D clinical angiograms, VAN‐GAN demonstrates its capability to facilitate accurate and unbiased segmentation of 3D vascular networks. By leveraging synthetic data, VAN‐GAN reduces the reliance on manual labeling, thus lowering the barrier to entry for high‐quality blood vessel segmentation (F1 score: VAN‐GAN vs. U‐Net = 0.84 vs. 0.87) and enhancing preclinical and clinical research into vascular structure and function.
- Top Cited Papers
- 1 November 2022
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 305 (2) , 375-386
Development and Validation of Multiparametric MRI–based Radiomics Models for Preoperative Risk Stratification of Endometrial Cancer
Three-dimensional radiomics-based machine learning models can stratify women with endometrial carcinoma at preoperative multiparametric MRI based on high-risk histopathologic features and can ident... Background Stratifying high-risk histopathologic features in endometrial carcinoma is important for treatment planning. Radiomics analysis at preoperative MRI holds potential to identify high-risk ...
- 1 November 2022
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 305 (2) , 375-386
Top Cited PapersDevelopment and Validation of Multiparametric MRI–based Radiomics Models for Preoperative Risk Stratification of Endometrial Cancer
Three-dimensional radiomics-based machine learning models can stratify women with endometrial carcinoma at preoperative multiparametric MRI based on high-risk histopathologic features and can ident... Background Stratifying high-risk histopathologic features in endometrial carcinoma is important for treatment planning. Radiomics analysis at preoperative MRI holds potential to identify high-risk ...
- Open Access
- 31 October 2022
- Published by Elsevier in Diagnostic and Interventional Imaging
- Vol. 104 (3) , 142-152
Predicting histopathology markers of endometrial carcinoma with a quantitative image analysis approach based on spherical harmonics in multiparametric MRI
- 31 October 2022
- Published by Elsevier in Diagnostic and Interventional Imaging
- Vol. 104 (3) , 142-152
Open AccessPredicting histopathology markers of endometrial carcinoma with a quantitative image analysis approach based on spherical harmonics in multiparametric MRI
- Open Access
- 21 September 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (6) , 2592-2608
The future of MRI in radiation therapy: Challenges and opportunities for the MR community
Radiation therapy is a major component of cancer treatment pathways worldwide. The main aim of this treatment is to achieve tumor control through the delivery of ionizing radiation while preserving healthy tissues for minimal radiation toxicity. Because radiation therapy relies on accurate localization of the target and surrounding tissues, imaging plays a crucial role throughout the treatment chain. In the treatment planning phase, radiological images are essential for defining target volumes and organs‐at‐risk, as well as providing elemental composition (e.g., electron density) information for radiation dose calculations. At treatment, onboard imaging informs patient setup and could be used to guide radiation dose placement for sites affected by motion. Imaging is also an important tool for treatment response assessment and treatment plan adaptation. MRI, with its excellent soft tissue contrast and capacity to probe functional tissue properties, holds great untapped potential for transforming treatment paradigms in radiation therapy. The MR in Radiation Therapy ISMRM Study Group was established to provide a forum within the MR community to discuss the unmet needs and fuel opportunities for further advancement of MRI for radiation therapy applications. During the summer of 2021, the study group organized its first virtual workshop, attended by a diverse international group of clinicians, scientists, and clinical physicists, to explore our predictions for the future of MRI in radiation therapy for the next 25 years. This article reviews the main findings from the event and considers the opportunities and challenges of reaching our vision for the future in this expanding field.
- 21 September 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (6) , 2592-2608
Open AccessThe future of MRI in radiation therapy: Challenges and opportunities for the MR community
Radiation therapy is a major component of cancer treatment pathways worldwide. The main aim of this treatment is to achieve tumor control through the delivery of ionizing radiation while preserving healthy tissues for minimal radiation toxicity. Because radiation therapy relies on accurate localization of the target and surrounding tissues, imaging plays a crucial role throughout the treatment chain. In the treatment planning phase, radiological images are essential for defining target volumes and organs‐at‐risk, as well as providing elemental composition (e.g., electron density) information for radiation dose calculations. At treatment, onboard imaging informs patient setup and could be used to guide radiation dose placement for sites affected by motion. Imaging is also an important tool for treatment response assessment and treatment plan adaptation. MRI, with its excellent soft tissue contrast and capacity to probe functional tissue properties, holds great untapped potential for transforming treatment paradigms in radiation therapy. The MR in Radiation Therapy ISMRM Study Group was established to provide a forum within the MR community to discuss the unmet needs and fuel opportunities for further advancement of MRI for radiation therapy applications. During the summer of 2021, the study group organized its first virtual workshop, attended by a diverse international group of clinicians, scientists, and clinical physicists, to explore our predictions for the future of MRI in radiation therapy for the next 25 years. This article reviews the main findings from the event and considers the opportunities and challenges of reaching our vision for the future in this expanding field.
- 23 January 2022
- Published by Springer Nature in European Radiology
- Vol. 32 (6) , 4116-4127
Malignancy risk stratification of cystic renal lesions based on a contrast-enhanced CT-based machine learning model and a clinical decision algorithm
Objective To distinguish benign from malignant cystic renal lesions (CRL) using a contrast-enhanced CT-based radiomics model and a clinical decision algorithm. Methods This dual-center retrospective study included patients over 18 years old with CRL between 2005 and 2018. The reference standard was histopathology or 4-year imaging follow-up. Training and testing datasets were acquired from two institutions. Quantitative 3D radiomics analyses were performed on nephrographic phase CT images. Ten-fold cross-validated LASSO regression was applied to the training dataset to identify the most discriminative features. A logistic regression model was trained to classify malignancy and tested on the independent dataset. Reported metrics included areas under the receiver operating characteristic curves (AUC) and balanced accuracy. Decision curve analysis for stratifying patients for surgery was performed in the testing dataset. A decision algorithm was built by combining consensus radiological readings of Bosniak categories and radiomics-based risks. Results A total of 149 CRL (139 patients; 65 years [56–72]) were included in the training dataset—35 Bosniak(B)-IIF (8.6% malignancy), 23 B-III (43.5%), and 23 B-IV (87.0%)—and 50 CRL (46 patients; 61 years [51–68]) in the testing dataset—12 B-IIF (8.3%), 10 B-III (60.0%), and 9 B-IV (100%). The machine learning model achieved high diagnostic performance in predicting malignancy in the testing dataset (AUC = 0.96; balanced accuracy = 94%). There was a net benefit across threshold probabilities in using the clinical decision algorithm over management guidelines based on Bosniak categories. Conclusion CT-based radiomics modeling accurately distinguished benign from malignant CRL, outperforming the Bosniak classification. The decision algorithm best stratified lesions for surgery and active surveillance. Key Points • The radiomics model achieved excellent diagnostic performance in identifying malignant cystic renal lesions in an independent testing dataset (AUC = 0.96). • The machine learning–enhanced decision algorithm outperformed the management guidelines based on the Bosniak classification for stratifying patients to surgical ablation or active surveillance.
- 23 January 2022
- Published by Springer Nature in European Radiology
- Vol. 32 (6) , 4116-4127
Malignancy risk stratification of cystic renal lesions based on a contrast-enhanced CT-based machine learning model and a clinical decision algorithm
Objective To distinguish benign from malignant cystic renal lesions (CRL) using a contrast-enhanced CT-based radiomics model and a clinical decision algorithm. Methods This dual-center retrospective study included patients over 18 years old with CRL between 2005 and 2018. The reference standard was histopathology or 4-year imaging follow-up. Training and testing datasets were acquired from two institutions. Quantitative 3D radiomics analyses were performed on nephrographic phase CT images. Ten-fold cross-validated LASSO regression was applied to the training dataset to identify the most discriminative features. A logistic regression model was trained to classify malignancy and tested on the independent dataset. Reported metrics included areas under the receiver operating characteristic curves (AUC) and balanced accuracy. Decision curve analysis for stratifying patients for surgery was performed in the testing dataset. A decision algorithm was built by combining consensus radiological readings of Bosniak categories and radiomics-based risks. Results A total of 149 CRL (139 patients; 65 years [56–72]) were included in the training dataset—35 Bosniak(B)-IIF (8.6% malignancy), 23 B-III (43.5%), and 23 B-IV (87.0%)—and 50 CRL (46 patients; 61 years [51–68]) in the testing dataset—12 B-IIF (8.3%), 10 B-III (60.0%), and 9 B-IV (100%). The machine learning model achieved high diagnostic performance in predicting malignancy in the testing dataset (AUC = 0.96; balanced accuracy = 94%). There was a net benefit across threshold probabilities in using the clinical decision algorithm over management guidelines based on Bosniak categories. Conclusion CT-based radiomics modeling accurately distinguished benign from malignant CRL, outperforming the Bosniak classification. The decision algorithm best stratified lesions for surgery and active surveillance. Key Points • The radiomics model achieved excellent diagnostic performance in identifying malignant cystic renal lesions in an independent testing dataset (AUC = 0.96). • The machine learning–enhanced decision algorithm outperformed the management guidelines based on the Bosniak classification for stratifying patients to surgical ablation or active surveillance.
- Open Access
Quantification of vascular networks in photoacoustic mesoscopy
Mesoscopic photoacoustic imaging (PAI) enables non-invasive visualisation of tumour vasculature and has the potential to assess prognosis and therapeutic response. Currently, evaluating vasculature using mesoscopic PAI involves visual or semi-quantitative 2D measurements, which fail to capture 3D vessel network complexity, and lack robust ground truths for assessment of segmentation accuracy. Here, we developed an in silico , phantom, in vivo , and ex vivo -validated end-to-end framework to quantify 3D vascular networks captured using mesoscopic PAI. We applied our framework to evaluate the capacity of rule-based and machine learning-based segmentation methods, with or without vesselness image filtering, to preserve blood volume and network structure by employing topological data analysis. We first assessed segmentation performance against ground truth data of in silico synthetic vasculatures and a photoacoustic string phantom. Our results indicate that learning-based segmentation best preserves vessel diameter and blood volume at depth, while rule-based segmentation with vesselness image filtering accurately preserved network structure in superficial vessels. Next, we applied our framework to breast cancer patient-derived xenografts (PDXs), with corresponding ex vivo immunohistochemistry. We demonstrated that the above segmentation methods can reliably delineate the vasculature of 2 breast PDX models from mesoscopic PA images. Our results underscore the importance of evaluating the choice of segmentation method when applying mesoscopic PAI as a tool to evaluate vascular networks in vivo .
Open AccessQuantification of vascular networks in photoacoustic mesoscopy
Mesoscopic photoacoustic imaging (PAI) enables non-invasive visualisation of tumour vasculature and has the potential to assess prognosis and therapeutic response. Currently, evaluating vasculature using mesoscopic PAI involves visual or semi-quantitative 2D measurements, which fail to capture 3D vessel network complexity, and lack robust ground truths for assessment of segmentation accuracy. Here, we developed an in silico , phantom, in vivo , and ex vivo -validated end-to-end framework to quantify 3D vascular networks captured using mesoscopic PAI. We applied our framework to evaluate the capacity of rule-based and machine learning-based segmentation methods, with or without vesselness image filtering, to preserve blood volume and network structure by employing topological data analysis. We first assessed segmentation performance against ground truth data of in silico synthetic vasculatures and a photoacoustic string phantom. Our results indicate that learning-based segmentation best preserves vessel diameter and blood volume at depth, while rule-based segmentation with vesselness image filtering accurately preserved network structure in superficial vessels. Next, we applied our framework to breast cancer patient-derived xenografts (PDXs), with corresponding ex vivo immunohistochemistry. We demonstrated that the above segmentation methods can reliably delineate the vasculature of 2 breast PDX models from mesoscopic PA images. Our results underscore the importance of evaluating the choice of segmentation method when applying mesoscopic PAI as a tool to evaluate vascular networks in vivo .