WLWei Liu

Wei Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Wei Liu has a total of 15 co-authors. Here are the top co-authors by number of shared publications:

  • Wei Tang

    State Key Laboratory of Oral Diseases, National Center for Stomatology, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China

    2 shared publications
  • Boyan Liu

    Foshan Stomatological Hospital, School of Medicine, Foshan University, Foshan, People’s Republic of China

    1 shared publication
  • Chang Liu

    State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases & Department of Oral and Maxillofacial Surgery, West China Hospital of Stomatology, Sichuan University, Chengdu, People’s Republic of China

    1 shared publication
  • Chang Liu

    State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases & Department of Oral and Maxillofacial Surgery, West China Hospital of Stomatology, Sichuan University, Chengdu, China

    1 shared publication
  • Hailin Zhu

    Machine Intelligence Laboratory, College of Computer Science, Sichuan University, Chengdu, People’s Republic of China

    1 shared publication
  • Jinglong Chen

    State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases & Department of Oral and Maxillofacial Surgery, West China Hospital of Stomatology, Sichuan University, Chengdu, People’s Republic of China

    1 shared publication

Latest Publications

  • Open Access

    Accuracy and reliability of 3D cephalometric landmark detection with deep learning

    by Boyan Liu, Chang Liu, Yutao Xiong, Hailin Zhu, Wei Zeng, Jinglong Chen, Jixiang Guo, Wei Liu, Wei Tang

    Background: Three-dimensional (3D) landmark detection is essential for assessing craniofacial growth and planning surgeries, such as orthodontic, orthognathic, traumatic, and plastic procedures. This study aimed to develop an automatic 3D landmarking model for oral and maxillofacial regions and to validate its accuracy, robustness and generalizability in both spiral computed tomography (SCT, 41 landmarks) and cone-beam computed tomography (CBCT, 14 landmarks) scans. Methods: The model was implemented using an optimized lightweight 3D U -Net network architecture. Its accuracy, robustness and generalizability were thoroughly evaluated and validated through a multicenter retrospective diagnostic study. The model was trained and tested on a data set of 480 SCT and 240 CBCT cases. An additional inference on a different data set of 320 SCT and 150 CBCT cases was performed. Mean radial error (MRE) and success detection rate within 2-, 3-, and 4-mm error thresholds were measured as the primary evaluation metrics. Error analyses for landmark detection along each coordinate axis were performed. Consistency tests among observers were conducted. Results: The average MRE for both SCT and CBCT was consistently below 1.3 mm and, notably, below 1.4 mm in complex conditions, such as malocclusion, missing dental landmarks, and the presence of metal artifacts. No significant differences in MRE and SDR at 2–4 mm were observed between external and internal SCT and CBCT sets. SCT bone landmarks were more precise than dental ones, with no difference between bone/soft tissue and dental/soft tissue. CBCT dental landmarks exhibited greater precision compared to bone landmarks. A detailed error analysis across the coordinate axes showed that the coronal axis had the highest error rates. The implementation of this model significantly improved the landmarking proficiency of senior and junior specialists by 15.9% and 28.9%, respectively, while also achieving a 6–9.5-fold acceleration in GUI interaction time. Conclusions: This study shows that the AI-driven model delivers high-precision 3D localization of oral and maxillofacial landmarks, even in complex scenarios. The model demonstrates potential as a promising computer-aided tool to assist specialists in conducting accurate and efficient localization analyses; however, its robustness and generalizability require prospective clinical validation to ensure utility across varied experience levels.


  • Exploring GPT-4o’s multimodal reasoning capabilities with panoramic radiograph: the role of prompt engineering

    by Yu-Tao Xiong, Wen-Jun Lian, Ya-Nan Sun, Wei Liu, Ji-Xiang Guo, Wei Tang, Chang Liu

    Objectives The aim of this study was to evaluate GPT-4o’s multimodal reasoning ability to review panoramic radiograph (PR) and verify its radiologic findings, while exploring the role of prompt engineering in enhancing its performance. Methods The study included 230 PRs from West China Hospital of Stomatology in 2024, which were interpreted to generate the PR findings. A total of 300 instances of interpretation errors, were manually inserted into the PR findings. The ablation study was conducted to assess whether GPT-4o can perform reasoning on PR under a zero-shot prompt. Prompt engineering was employed to enhance the reasoning capabilities of GPT-4o in identifying interpretation errors with PRs. The prompt strategies included chain-of-thought, self-consistency, in-context learning, multimodal in-context learning, and their systematic integration into a meta-prompt. Recall, accuracy, and F1 score were employed to evaluate the outputs. Subsequently, the localization capability of GPT-4o and its influence on reasoning capability were evaluated. Results In the ablation study, GPT-4o’s recall increased significantly from 2.67 to 43.33% upon acquiring PRs (P < 0.001). GPT-4o with the meta prompt demonstrated improvements in recall (43.33% vs. 52.67%, P = 0.022), accuracy (39.95% vs. 68.75%, P < 0.001), and F1 score (0.42 vs. 0.60, P < 0.001) compared to the zero-shot prompt and other prompt strategies. The localization accuracy of GPT-4o was 45.67% (137 out of 300, 95% CI: 40.00 to 51.34). A significant correlation was observed between its localization accuracy and reasoning capability under the meta prompt (φ coefficient = 0.33, p < 0.001). The model’s recall increased by 5.49% (P = 0.031) by providing accurate localization cues within the meta prompt. Conclusions GPT-4o demonstrated a certain degree of multimodal capability for PR, with performance enhancement through prompt engineering. Nevertheless, its performance remains inadequate for clinical requirements. Future efforts will be necessary to identify additional factors influencing the model’s reasoning capability or to develop more advanced models. Clinical relevance Evaluating GPT-4o's capability to interpret and reason through PRs and exploring potential methods to enhance its performance before clinical application in assisting radiological assessments.