PGPeng Gao

Peng Gao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Peng Gao has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Channel ratio normalized calibration of the solar reflectance bands from FY-3D/MERSI lunar observations

    by Kang Chen, Zhongyi Han, Zhao Wang, Yujie Cui, Mingkun Wang, Hanbo Zhen, Peng Gao, Jingjing Ai, Chengli Qi, Dawei Zhang, et al.

    1. Fengyun 3D (FY-3D) is the fourth satellite of the second-generation polar-orbiting meteorological satellite series. It provides global all-weather, multispectral and three-dimensional observatio...

  • Open Access

    XCO2 distribution in China based on multi-source satellite data fusion

    by Xiaolin Wang, Jingjing Ai, Peng Gao, Yujie Cui, Mingkun Wang, Hanbo Zhen, Hongxia Wang, Tingting Fan

    The spatiotemporal distribution of the carbon dioxide column concentration (XCO 2 ) in China is generated by utilizing the high accuracy surface modeling (HASM) data fusion method, where the simulation output of the global earth observing system chemistry model (GEOS-Chem) is used as the driving field while the observation data from the greenhouse gases observing satellite (GOSAT) and orbiting carbon observatory-2 (OCO-2) as the optimal control constraints. The simulation results of the GEOS-Chem model with its grid resolutions of 2°×2.5° and 0.25°×0.3125° are compared with the total carbon column observing network (TCCON) station data, and the mean error (ME) together with the root mean square error (RMSE) at Hefei station decrease by 0.7248 ppm and 0.6901 ppm, respectively, while the ME and RMSE decreasing by 0.0371 ppm and 0.2426 ppm at Xianghe station. Besides, the sensitivity of the sampling weight \(\lambda\) of observation data and the sampling radius to the HASM data fusion accuracy is analyzed, and the optimal values \(\lambda =0.6\) and \(r=3\) corresponding to the highest fusion accuracy are obtained through the cross validation. The validation results show that the MAE and RMSE decrease from 1.6282 ppm and 2.3808 ppm to 1.1890 ppm and 1.9377 ppm before and after the HASM data fusion, respectively. The spatial distribution of the monthly XCO 2 after the HASM data fusion is similar to the simulation result from 2017 to 2018, indicating that the HASM data fusion method not only simulates the XCO 2 with high precision, but also ameliorates effectively the spatial distribution of the XCO 2 .

  • Open Access

    Error Analysis on the Thermal Emissive Band Calibration for the MERSI

    by Yue Huang, Peng Gao, Zhenlin Yang

    The remote sensor mounted on the Fengyun-3C (FY-3C) will decay naturally during the operation, causing a decrease in the accuracy of the satellite data. Therefore, an effective monitoring method must be adopted to study the performance changes of the instrument. The theoretical expressions of the absolute and relative errors for the earth field of view (FOV) radiance together with its equivalent brightness temperature are given by analyzing the response value offsets of the earth FOV along with the blackbody (BB) pixel. In order to further describe the influences of different parameters on the absolute and relative errors for the FOV radiance and equivalent brightness temperature, the computer simulations are performed, and the absolute errors for the FOV radiance and equivalent brightness temperature caused the response value offset of the BB pixel firstly decrease and then increase with the increasing of the earth FOV response value. The absolute and relative errors for the FOV radiance caused the response value offset of the earth FOV firstly decrease and then increase, and the absolute error for the equivalent brightness temperature increases while its relative error decreases with the increasing of the response value of the earth FOV. This research provides an important theoretical guidance for improving the on-orbit performance of the FY-3C/ MERSI.

  • Automatic acquisition method for evaluating the on-orbit modulation transfer function based on lunar targets

    by Jingjing Ai, Zhaoming Bai, Peng Gao, Zhongyi Han, Yue Huang, Lin Chen

    In view of the existing method having a great subjectivity for the lunar edge selection, we propose an automatic knife-edge detection method based on the Hough transform to evaluate the on-orbit modulation transfer function (MTF) of the satellite remote sensor. This novel method avoids the dependence of the on-orbit MTF measurement on the edge selection location, overcoming the limitation of the traditional method needing to identify the lunar shape and fix its edge area. On basis of two different edge detection algorithms (Sobel operator and Prewitt operator), the binary edge images of the moon are acquired, thus obtaining a series of edges satisfying the determination requirement by the Hough transform, and the MTFs corresponding to each knife-edge are calculated to obtain the optimal MTF. The automatic knife-edge detection method greatly improves the accuracy of the lunar edge selection, and the MTF obtained by the novel method is obviously better than that of the traditional method. In order to verify the effectiveness of the novel method, the long time series of the on-orbit MTFs for the FY-2G and FY-2E satellite measurements are given, indicating that the FY-2E observation has higher stability and better performance compared with that of the FY-2G satellite. This study has an important practical significance for evaluating the on-orbit stability of the satellite its optical imaging quality.


  • Image quality and spectral performance evaluations of a polarization imaging spectrometer based on a Savart polariscope

    by Jingjing Ai, Peng Gao, Qingying Chen, Shuaiyi Zhang

    The modulation transfer function (MTF) and signal-to-noise ratio (SNR) are the key parameters to evaluate quantitatively the image quality and spectral performance in a polarization imaging spectrometer based on a Savart polariscope. In order to evaluate the image quality and reflect the detecting ability of the imaging spectrometer, calibration experiments on the MTF, SNR, and spectral resolution were carried out and some important conclusions were obtained. For incident radiance values 4.464, 3.119, and 0.523 w/m2·sr, the average SNRs of the interferogram were 500, 400, and 200 dB, respectively, and the MTF is 0.24. During the spectral resolution calibration, the maximum optical path difference was set as 57.08 µm, and the measured value is greater than the theoretical value, which is mainly caused by the structural design of the polarization imaging spectrometer. For the wavelength range of [500 nm, 600 nm], the SNR of the spectrum is lower and about 50 dB, while the SNR is obviously higher in a range of λ∈[600 nm, 960 nm]. This study provides a theoretical and practical guidance for improving the image quality and judging the spectral performance of the polarization imaging spectrometer.


  • Radiometric calibration of tempospatially modulated polarization interference imaging spectrometer

    by Peng Gao, Jingjing Ai, Chunmin Zhang

    The tempospatially modulated polarization interference imaging spectrometer (TSMPIIS) nominated by the Ministry of Scence and Technology, takes part in the “Eleventh Five-Year National Science and Technology Exhibition.” In order to improve the detecting precision of the TSMPIIS, its radiometric calibration scheme is proposed on the basis of the solar simulator, integrating sphere, monochromator, and spectroradiometer. Under the conditions of changing the exposure time and radiant brightness, the CCD linear responses for the TSMPIIS were first tested to validate the reliability of the radiometric calibration performed with a linear response model, and the linear errors were less than 0.15% and 1.15%, respectively. A novel method is put forward to calibrate the nonuniformity of CCD pixels, and the least squares method can commendably correct the uneven effect in the spatial direction. Besides, the absolute radiometric calibration establishes a corresponding relation between the dimensionless intensity output from the TSMPIIS and the target radiant brightness. The study lays the foundation for the engineering application of the TSMPIIS, such as remote sensing detection, and has an important significance for the development of our instrument and equipment technology with independent intellectual property rights.


  • Realization of the ultrawideband negative index metamaterials by its multiple-band

    by Peng Gao, Jingjing Ai, Yongqiang Kang, Chunmin Zhang

    In this paper, a concept of multiple-band is proposed to broaden the bandwidth of the negative index metamaterials. The multiple-band, which is realized by a new metamaterial sample composed of the double-E-ring, has more than two negative refraction bands at comparable frequencies. When the metamaterial produces a multiple-band, the bandwidth can be greatly enhanced, yielding an increased numbers of negative bands. The experimental measurements and computer simulations for the multiple-negative-passband metamaterial at microwave frequencies are presented. The effective permittivity and permeability of several resonant frequencies are retrieved from the simulation scattering data, and the experimental measurements show good agreement with the simulative results.