Ganesh Kasinadhuni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ganesh Kasinadhuni has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Dinakar Bootla
Department of Cardiology, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, India
1 shared publication - Kewal Kanabar
Department of Cardiology, U.N. Mehta Institute of Cardiology and Research Centre, Ahmedabad, India
1 shared publication - Krishna Prasad
Cardiology, NRI Medical College, Vijayawada, IND
1 shared publication - Krishna Santosh Vemuri
Department of Cardiology, Postgraduate Institute of Medical Education and Research, Chandigarh, Chandigarh, India
1 shared publication - Nitin Parashar
Department of Cardiology, All India Institute of Medical Sciences, New Delhi, India
1 shared publication - Prashant Panda
Department of Cardiology, Post Graduate Institute of Medical Education and Research, Chandigarh, India
1 shared publication
Latest Publications
- Open Access
- 20 October 2020
- Published by Springer Nature in The Egyptian Heart Journal
- Vol. 72 (1) , 1-4
Refractory axillary venous spasm during permanent pacemaker implantation
Background: Vascular spasm is well known to occur in the arterial system. Central venous spasm during pacemaker implantation is uncommon with only a few cases reported from time to time. Sometimes, the venous spasms may not respond to nitroglycerine injections which requires a change of access site and undue discomfort for the patient. Case presentation: A 72-year-old female patient with no prior comorbidities presented to us with recurrent dizziness on exertion and at rest. The electrocardiogram showed complete heart block, likely to be of sclerodegenerative etiology as the patient did not have any ischemic symptoms, also the electrocardiogram and echocardiogram did not show any evidence of ischemia. As part of the hospital protocol, a venogram was performed by giving intravenous diluted contrast (iohexol) through the left brachial vein, which showed good-sized axillary and subclavian veins. We attempted to cannulate the left axillary vein with a 16G needle using Seldinger technique, but the axillary vein could not be cannulated despite multiple attempts. We gave incremental boluses of intravenous nitroglycerine, despite that the left axillary vein could not be cannulated. Repeat intravenous contrast injection showed severe spasm of axillary and subclavian veins. Finally, the axillary vein was cannulated from the right side using anatomical landmarks and a pacemaker was implanted. Conclusions: Venous spasm during device implantation although uncommon, it should be anticipated in patients with difficult cannulation to prevent inadvertent complications like pneumothorax and arterial injuries. Mild venous spasm may relieve with time but severe venous spasm may require a change of access site
- 20 October 2020
- Published by Springer Nature in The Egyptian Heart Journal
- Vol. 72 (1) , 1-4
Open AccessRefractory axillary venous spasm during permanent pacemaker implantation
Background: Vascular spasm is well known to occur in the arterial system. Central venous spasm during pacemaker implantation is uncommon with only a few cases reported from time to time. Sometimes, the venous spasms may not respond to nitroglycerine injections which requires a change of access site and undue discomfort for the patient. Case presentation: A 72-year-old female patient with no prior comorbidities presented to us with recurrent dizziness on exertion and at rest. The electrocardiogram showed complete heart block, likely to be of sclerodegenerative etiology as the patient did not have any ischemic symptoms, also the electrocardiogram and echocardiogram did not show any evidence of ischemia. As part of the hospital protocol, a venogram was performed by giving intravenous diluted contrast (iohexol) through the left brachial vein, which showed good-sized axillary and subclavian veins. We attempted to cannulate the left axillary vein with a 16G needle using Seldinger technique, but the axillary vein could not be cannulated despite multiple attempts. We gave incremental boluses of intravenous nitroglycerine, despite that the left axillary vein could not be cannulated. Repeat intravenous contrast injection showed severe spasm of axillary and subclavian veins. Finally, the axillary vein was cannulated from the right side using anatomical landmarks and a pacemaker was implanted. Conclusions: Venous spasm during device implantation although uncommon, it should be anticipated in patients with difficult cannulation to prevent inadvertent complications like pneumothorax and arterial injuries. Mild venous spasm may relieve with time but severe venous spasm may require a change of access site