Ali Taheri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ali Taheri has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
M. Askari
Radiation Applications Research School, Nuclear Science and Technology Research Institute, Tehran, Iran
5 shared publicationsMojtaba Askari
Nuclear Science and Technology Research Institute, Tehran, Iran
4 shared publicationsJavad Kochakpour
3 shared publicationsMohammad Taghan Sasanpour
Radiation Applications Research School, Nuclear Science and Technology Research Institute, Tehran, Iran
3 shared publications- Mojtaba Askari
Radiation Applications Research School, Nuclear Science and Technology Research Institute , P.O. Box 14395-836, Tehran, Iran
3 shared publications Abbas Farrokhizadeh
Iran Radiation Application Development Company (IRAD Co.), Atomic Energy Organization of Iran, Tehran, I.R. of Iran, PO Box:14395-836
1 shared publication
Latest Publications
- Open Access
- 30 April 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 58 (8)
Development of a compact and variable-resolution X-ray backscatter imaging scanner based on pencil-beam scanning
- 30 April 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 58 (8)
Open AccessDevelopment of a compact and variable-resolution X-ray backscatter imaging scanner based on pencil-beam scanning
- 11 November 2025
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 335 (2) , 1205-1213
Development of a gamma-ray multiphase flow monitoring system utilizing machine learning
- 11 November 2025
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 335 (2) , 1205-1213
Development of a gamma-ray multiphase flow monitoring system utilizing machine learning
- 12 September 2025
- Published by Springer Nature in Signal, Image and Video Processing
- Vol. 19 (13) , 1-8
Hybrid deep learning and wavelet decomposition approach for X-ray scatter artifact correction
- 12 September 2025
- Published by Springer Nature in Signal, Image and Video Processing
- Vol. 19 (13) , 1-8
Hybrid deep learning and wavelet decomposition approach for X-ray scatter artifact correction
- Open Access
- 29 April 2025
- Published by SCI AND TECH UNIVERSAL INC in Journal of Nuclear Research and Applications
- p. e1729
Improving X-ray Industrial Images: A Python-Based Approach
This article introduces an approach based on using Python in the processing of industrial X-ray radiographs. This approach utilizes three key image processing techniques including bilateral filtering, unsharp masking, and wavelet transformation to enhance the contrast, reduce noise, and improve structural detail of X-ray radiographs, especially in industrial applications. It targets and can help industry and nondestructive testing (NDT) specialists to further improve their analysis and decision-making accuracy. To perform the experimental tests, a laboratory test setup including an industrial x-ray generator and a flat panel detector were utilized. The obtained results show a good improvement in signal-to-noise ratio (SNR) while effectively preserving image structures. A detailed quantitative analysis using mean squared error (MSE), peak signal-to-noise ratio (PSNR), and structural similarity index (SSIM) approved the effectiveness of the mentioned techniques. The findings show the potential of the implemented method in industrial radiography, especially for improved defect detection and quality assurance.
- 29 April 2025
- Published by SCI AND TECH UNIVERSAL INC in Journal of Nuclear Research and Applications
- p. e1729
Open AccessImproving X-ray Industrial Images: A Python-Based Approach
This article introduces an approach based on using Python in the processing of industrial X-ray radiographs. This approach utilizes three key image processing techniques including bilateral filtering, unsharp masking, and wavelet transformation to enhance the contrast, reduce noise, and improve structural detail of X-ray radiographs, especially in industrial applications. It targets and can help industry and nondestructive testing (NDT) specialists to further improve their analysis and decision-making accuracy. To perform the experimental tests, a laboratory test setup including an industrial x-ray generator and a flat panel detector were utilized. The obtained results show a good improvement in signal-to-noise ratio (SNR) while effectively preserving image structures. A detailed quantitative analysis using mean squared error (MSE), peak signal-to-noise ratio (PSNR), and structural similarity index (SSIM) approved the effectiveness of the mentioned techniques. The findings show the potential of the implemented method in industrial radiography, especially for improved defect detection and quality assurance.
- Open Access
- 1 March 2025
- Published by Academic World Research in Iranian Journal of Physics Research
- Vol. 24 (4) , 295-312
Design and construction of a self-shielded radiation system for agricultural products
It is possible to extend the shelf life and reduce the waste of agricultural products due to removing bacteria, viruses, insects and pests by means of gamma irradiation with the absorbed dose amount determined by microbiology and food laboratories. For this purpose, the design and construction of a self-shielded gamma irradiation system for irradiation of grains and legumes with radioactive sources of cobalt-60 with activity of 50 kilocuries was performed. In this system, agricultural products are fed in bulk into the input funnel with a conveyor belt. The products move from the inlet funnel to the spiral due to gravitational force and after passing through it, they enter the cask (irradiation chamber) to be irradiated. The absorbed dose amount of agricultural products depends on the time duration that they stay in the irradiation cask, their density, and their type of products, etc. Irradiation time can be adjusted by changing the rotational speed of the screw conveyor considering the last amount of activity remained in the cask at the time of irradiation by means of a software product. The design and construction of type 1 radiation system is based on ANSI/HPSN43.7-2018 standard designed using Solidworks software and basic biological shielding standard ISIRI7751 modeled and calculated by MCNPX software. Other designs and constructions, including industrial and facility drawings, electrical drawings, structural analysis, welding and electrical and control systems were also carried out based on their respective standards. The built mechanical structure can withstand 140kN of loading. The unique design of the entrance chamber in a form of a step instead of a spiral reduces the volume of lead material required for shielding by 2 tons compared to a similar irradiation system made in Hungary. The output mass flow rate of irradiated products in this system is about 1 ton/hour for wheat with dose of 200 grays. The dose uniformity ratio of 2 was obtained, which is acceptable for industrial radiation works.
- 1 March 2025
- Published by Academic World Research in Iranian Journal of Physics Research
- Vol. 24 (4) , 295-312
Open AccessDesign and construction of a self-shielded radiation system for agricultural products
It is possible to extend the shelf life and reduce the waste of agricultural products due to removing bacteria, viruses, insects and pests by means of gamma irradiation with the absorbed dose amount determined by microbiology and food laboratories. For this purpose, the design and construction of a self-shielded gamma irradiation system for irradiation of grains and legumes with radioactive sources of cobalt-60 with activity of 50 kilocuries was performed. In this system, agricultural products are fed in bulk into the input funnel with a conveyor belt. The products move from the inlet funnel to the spiral due to gravitational force and after passing through it, they enter the cask (irradiation chamber) to be irradiated. The absorbed dose amount of agricultural products depends on the time duration that they stay in the irradiation cask, their density, and their type of products, etc. Irradiation time can be adjusted by changing the rotational speed of the screw conveyor considering the last amount of activity remained in the cask at the time of irradiation by means of a software product. The design and construction of type 1 radiation system is based on ANSI/HPSN43.7-2018 standard designed using Solidworks software and basic biological shielding standard ISIRI7751 modeled and calculated by MCNPX software. Other designs and constructions, including industrial and facility drawings, electrical drawings, structural analysis, welding and electrical and control systems were also carried out based on their respective standards. The built mechanical structure can withstand 140kN of loading. The unique design of the entrance chamber in a form of a step instead of a spiral reduces the volume of lead material required for shielding by 2 tons compared to a similar irradiation system made in Hungary. The output mass flow rate of irradiated products in this system is about 1 ton/hour for wheat with dose of 200 grays. The dose uniformity ratio of 2 was obtained, which is acceptable for industrial radiation works.
- Open Access
- 6 February 2025
- Published by Walter de Gruyter GmbH in Reviews in Chemical Engineering
- Vol. 41 (3) , 241-268
Applications of ionizing irradiation in oil industry: a review
Ionizing radiation offers unique opportunities for addressing critical challenges in the oil industry, including efficient hydrocarbon processing and environmental remediation. This review highlights the diverse applications of ionizing radiation in oil-related processes, such as cracking, polymerization, desulfurization, and the treatment of oilfield-produced wastewater. By synthesizing findings from recent studies, this paper emphasizes the advantages of radiation technologies in enhancing process efficiency, reducing environmental impact, and supporting sustainable energy production. The necessity of this review lies in bridging knowledge gaps, identifying emerging trends, and fostering the broader adoption of advanced radiation-based technologies in the oil sector.
- 6 February 2025
- Published by Walter de Gruyter GmbH in Reviews in Chemical Engineering
- Vol. 41 (3) , 241-268
Open AccessApplications of ionizing irradiation in oil industry: a review
Ionizing radiation offers unique opportunities for addressing critical challenges in the oil industry, including efficient hydrocarbon processing and environmental remediation. This review highlights the diverse applications of ionizing radiation in oil-related processes, such as cracking, polymerization, desulfurization, and the treatment of oilfield-produced wastewater. By synthesizing findings from recent studies, this paper emphasizes the advantages of radiation technologies in enhancing process efficiency, reducing environmental impact, and supporting sustainable energy production. The necessity of this review lies in bridging knowledge gaps, identifying emerging trends, and fostering the broader adoption of advanced radiation-based technologies in the oil sector.
- Open Access
- 28 November 2024
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 57 (4) , 103321
Developing a 2D position-sensitive detector utilizing the large plate plastic scintillator
- 28 November 2024
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 57 (4) , 103321
Open AccessDeveloping a 2D position-sensitive detector utilizing the large plate plastic scintillator
- 1 September 2023
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 18 (09) , P09044
Industrial gamma-ray computed tomography utilizing rod plastic scintillators
In this work, an industrial gamma-ray-based computed tomography system is constructed using a 50 cm rod plastic scintillator coupled to PMTs at both ends. The ability of the system is evaluated using two phantoms: one for contrast and one for spatial resolution. Different cross-sectional images are reconstructed for the phantoms using MLEM algorithm to extract evaluation parameters. Such a system is suitable for scanning large objects due to its spatial resolution limitation, which is about 1 cm.
- 1 September 2023
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 18 (09) , P09044
Industrial gamma-ray computed tomography utilizing rod plastic scintillators
In this work, an industrial gamma-ray-based computed tomography system is constructed using a 50 cm rod plastic scintillator coupled to PMTs at both ends. The ability of the system is evaluated using two phantoms: one for contrast and one for spatial resolution. Different cross-sectional images are reconstructed for the phantoms using MLEM algorithm to extract evaluation parameters. Such a system is suitable for scanning large objects due to its spatial resolution limitation, which is about 1 cm.
- 1 February 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (2) , 023308
Detection performance of pixelated lutetium–yttrium oxyorthosilicate (LYSO) scintillators for high-resolution photon-counting CT imaging
High-resolution photon-counting detector (PCD) computed tomography (CT) imaging is increasingly used for several applications. Recent technological advances in CT instrumentation have introduced various types of radiation detectors. Therefore, this work aims at evaluating the lutetium–yttrium oxyorthosilicate (LYSO) scintillator for use in PCD CT from a detector point of view. To do so, a mini-CT prototype was designed and constructed based on the pixelated LYSO blocks. The detector comprises four 10 × 10 linearly arranged LYSO blocks coupled with four position-sensitive photomultiplier tubes. The prototype utilizes a point gamma-ray source along with a cone-beam collimator. An in-home MATLAB-based data processing software package was also developed for storing the list-mode data, event positioning, and energy windowing. A set of experiments were conducted to assess the performance of the constructed energy-resolved LYSO:Ce detector for mini-CT imaging. The results show good crystal identification for all blocks with a maximum peak-to-valley ratio of 3.48. In addition, the findings confirm that the developed detector is position-sensitive. The 20% energy window provides an optimal performance by simultaneously providing good crystal identification and a scatter removal factor of 0.71. A 96% uniformity was also observed when the detector was irradiated with a uniform flood. The spatial resolution of the mini-CT prototype in the x- and y-directions was calculated to be 0.9 and 0.93 mm, respectively, corrected for a magnification factor of 2.5. It is concluded that the pixelated LYSO crystal is a promising alternative to the current detectors and would be the scintillator of choice for high-resolution PCD CT imaging tasks.
- 1 February 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (2) , 023308
Detection performance of pixelated lutetium–yttrium oxyorthosilicate (LYSO) scintillators for high-resolution photon-counting CT imaging
High-resolution photon-counting detector (PCD) computed tomography (CT) imaging is increasingly used for several applications. Recent technological advances in CT instrumentation have introduced various types of radiation detectors. Therefore, this work aims at evaluating the lutetium–yttrium oxyorthosilicate (LYSO) scintillator for use in PCD CT from a detector point of view. To do so, a mini-CT prototype was designed and constructed based on the pixelated LYSO blocks. The detector comprises four 10 × 10 linearly arranged LYSO blocks coupled with four position-sensitive photomultiplier tubes. The prototype utilizes a point gamma-ray source along with a cone-beam collimator. An in-home MATLAB-based data processing software package was also developed for storing the list-mode data, event positioning, and energy windowing. A set of experiments were conducted to assess the performance of the constructed energy-resolved LYSO:Ce detector for mini-CT imaging. The results show good crystal identification for all blocks with a maximum peak-to-valley ratio of 3.48. In addition, the findings confirm that the developed detector is position-sensitive. The 20% energy window provides an optimal performance by simultaneously providing good crystal identification and a scatter removal factor of 0.71. A 96% uniformity was also observed when the detector was irradiated with a uniform flood. The spatial resolution of the mini-CT prototype in the x- and y-directions was calculated to be 0.9 and 0.93 mm, respectively, corrected for a magnification factor of 2.5. It is concluded that the pixelated LYSO crystal is a promising alternative to the current detectors and would be the scintillator of choice for high-resolution PCD CT imaging tasks.
- 1 July 2022
- Published by Pleiades Publishing Ltd in Russian Journal of Nondestructive Testing
- Vol. 58 (7) , 598-606
Artificial Neural Networks Based Method for Measuring the Distance between Two Metal Plates Using Compton Scattering
One of the major problems for the determination of the distance between two metal plates based on Compton scattering is complicated calculations. This method needs to consider many parameters and relations between them. The accuracy of the method strongly depends on the thicknesses and materials of the plates. As a result, the device must be calibrated for all possible different plate thicknesses so that by knowing some input conditions and using complex interpolation methods, the count recorded in the detector can be converted to a distance between two plates. In this condition, employing artificial neural networks can be a powerful alternative for the difficult calibration and analytical interpolation procedure. In this paper, an artificial neural network consisting of a three-layer perceptron was developed and trained for identifying the distance between steel and aluminum plates with thicknesses ranging from 1 to 10 mm. In the proposed method, a Cs-137 gamma-ray source with an activity of 35 μCi was used.
- 1 July 2022
- Published by Pleiades Publishing Ltd in Russian Journal of Nondestructive Testing
- Vol. 58 (7) , 598-606
Artificial Neural Networks Based Method for Measuring the Distance between Two Metal Plates Using Compton Scattering
One of the major problems for the determination of the distance between two metal plates based on Compton scattering is complicated calculations. This method needs to consider many parameters and relations between them. The accuracy of the method strongly depends on the thicknesses and materials of the plates. As a result, the device must be calibrated for all possible different plate thicknesses so that by knowing some input conditions and using complex interpolation methods, the count recorded in the detector can be converted to a distance between two plates. In this condition, employing artificial neural networks can be a powerful alternative for the difficult calibration and analytical interpolation procedure. In this paper, an artificial neural network consisting of a three-layer perceptron was developed and trained for identifying the distance between steel and aluminum plates with thicknesses ranging from 1 to 10 mm. In the proposed method, a Cs-137 gamma-ray source with an activity of 35 μCi was used.