Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lei Wang has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of Orifice Layout on Low Frequency Oscillation Flow in Jet Condensation System

    by Chengfeng Zhu, Yanzhong Li, Lei Wang, Fushou Xie

    Low-frequency oscillatory flow is a long-standing instability in cryogenic jet condensation systems and is closely associated with abnormal pressure fluctuations in propulsion pipelines. While previous studies mainly focused on operating conditions, the role of injector orifice layout in triggering low-frequency oscillations remains unclear. In this work, a three-dimensional numerical investigation was conducted to examine the effect of orifice layout on condensation-induced oscillatory flow in an oxygen jet condensation system. A curvature-coupled mass transfer model is employed, in which the interfacial mass transfer rate is dynamically linked to local vapor–liquid interfacial curvature, enabling accurate representation of interfacial evolution. A series of numerical cases are designed by varying the number, arrangement, and diameter of orifices under different combinations of mass rate, mass flux, and total injection area. Two distinct condensation patterns are identified: suck-back chugging and weak pulsation. Pronounced low-frequency oscillations are observed only for specific orifice layouts. When the total injection area and gaseous oxygen mass rate are maintained, chugging persists under different layouts, producing dominant frequencies of approximately 10~11 Hz and pressure amplitudes of about 80~120 kPa. Once either the total area or mass rate is altered, the system transitions to weak pulsation with pressure fluctuations below 3 kPa. These results demonstrate that low-frequency oscillatory flow is a layout-enabled instability rather than a mass-flux-controlled phenomenon, highlighting the importance of injector geometric design in regulating condensation-induced oscillations.

  • Open Access

    Numerical investigation on unstable oscillation of oxygen jet condensation in cryogenic liquid rocket

    by Chengfeng Zhu, Yanzhong Li, Lei Wang, Fushou Xie, Yuan Ma

    Oxygen jet condensation always occurs with intense unstable oscillation in the cryogenic delivery pipe of a space launch vehicle. This phenomenon threatens the safety of the propulsion pipeline. It is essential to explore the transient physical features of oxygen jet condensation precisely, including the spectrum of pressure oscillation. Aiming at a deeper understanding of the thermal hydraulic characteristic of oxygen jet condensation, abundant simulations are carried out using a modified phase change method. In this model, the height function method is introduced to capture the interfacial curvature to reveal the mechanism of periodic fluctuation. The simulation proves that three typical flow patterns are found at variant operating conditions in oxygen jet condensation: chugging, oscillation, and swinging. The condensation regime diagram is summarized according to the flow pattern distribution. The chugging flow, along with the phenomenon of liquid oxygen sucked-back flow, shows the most intense pressure oscillation with a maximum amplitude of 133 kPa. In the oscillation flow, the oxygen vapor plume shrinks periodically with a low frequency of about 10 Hz. The swinging flow is a stable flow pattern with a slight pulsation of oxygen vapor plume wake. Its amplitude of pressure oscillation is approximately 1–3 kPa. The influence of liquid oxygen mass flow rate and subcooling on the unstable characteristic is also obtained. These findings offer ample theoretical direction for the development of the space launch vehicle.


  • Open Access

    Low-frequency oscillation flow in nitrogen jet condensation

    by Chengfeng Zhu, Yanzhong Li, Lei Wang, Jiahui Yang, Cui Li

    Jet condensation is a complicated two-phase flow phenomenon that occurs in pipe flow, especially in cryogenic fluids. In this study, the condensation flow dynamics of a stream of nitrogen (N2) injected into a subcooled liquid nitrogen (LN2) flow was photographically investigated using a high-speed camera. The pulsating pressure was measured at different observation points using dynamic pressure transducers. Three typical condensation flow patterns were observed and measured under different nitrogen volume fluxes: suck-back flow, transition flow, and oscillation flow. Suck-back flow occurs at a smaller N2 volume flux, where the LN2 is periodically sucked back into the gas chamber. Oscillation flow is encountered at larger N2 volume flux, along with intense pressure fluctuations. Using fast Fourier transform analysis, the frequency of these pressure oscillations was found to be in the range 16–18 Hz with a maximum amplitude of about 10 kPa. An image-processing method was developed to track the fluid motion in the dynamic photographs recorded by the high-speed camera according to the local changes of pixels. The results show the presence of a periodic shrinking of the vapor-plume trail with the same frequency as the pressure oscillation. The mechanism for the low-frequency oscillation flow is, therefore, identified as periodic interfacial condensation. The findings of this study provide strong evidence for the origin of the low-frequency pressure oscillations observed in cryogenic liquid rocket engines. This information can be used to improve the design and operation of such propulsion systems.

  • Open Access

    Investigation on the Electrostatics Saturation of Flow Electrification in the Liquid Hydrogen Transportation

    by Bowen Liu, Yanzhong Li, Lei Wang, Yuan Ma

    Research on the flow electrification characteristic is of paramount importance for ensuring the electrostatic safety of liquid hydrogen transportation systems. However, the discussion about electrostatic saturation in flow electrification has been lacking. To address this gap, a theoretical model governing the process of flow electrification is constructed which couples the charge conservation equation with the Navier-Stokes equations and applies the Neumann boundary conditions at the solid-liquid interface, and the application of this model is validated by existing experimental data with the simulation parameters of At and n being 9.08 × 1012 and 0.85 for liquid hydrogen. A comparison with benzene reveals that benzene almost reaches the electrostatic saturation state after flowing one meter, whereas the flow of liquid hydrogen remains in the linear growth stage. However, with an increase in pipe length, a gradual saturation trend emerges in the curves of streaming current versus flow distance when the flow distance exceeds 10 m. At the outlet, the corresponding streaming current and charge density are approximately 160 pA and 3 μC/m3, respectively, significantly higher than those observed at one-meter flow distance. Furthermore, the influences of pipe radius and flow velocity on the arrival of electrostatic saturation are analyzed, and the results show that increasing both the pipe radius and flow velocity leads to a delay in the arrival of electrostatic saturation and enhances the saturation value of the streaming current. In conclusion, this study thoroughly discusses the development of flow electrification along with the flow distance and the phenomenon of electrostatic saturation in the long-distance flow of liquid hydrogen, which is crucial for the safe transportation of liquid hydrogen over extended distances.


  • Open Access

    Feasibility Study on Space Reorientation for Liquid Hydrogen Tanks by Means of Evaporated Exhaust Gas

    by Jiajia Liang, Yuan Ma, Yanzhong Li, Lei Wang, Xiaozhong Luo

    A thermal equilibrium model is established to investigate the heat leak of a space liquid hydrogen tank under different thermal adiabatic structures. The feasibility of the common bulkhead tank in realizing thrust or rotation reorientation by evaporated exhaust gas has been systematically studied. The results indicate that the space radiation heat leak is the primary heat leak in spray-on foam insulation (SOFI) adiabatic tanks. However, the common bulkhead heat leak is dominant in the tank with multilayer insulation (MLI) or self-evaporation vapor cooled shield (VCS). For the continuous stable adiabatic exhaust, the tank with SOFI (over 114 W/m2) could realize reorientation with the acceleration of over 5.5 × 10−4 m/s2 generated by the exhaust. Meanwhile, the tank that adopted MLI or VCS (below 18 W/m2) struggled to achieve gas–liquid separation with the acceleration below 8.7 × 10−5 m/s2 generated by exhausting. The rotational angular velocity of the tank through exhausting increases with the fill level dropping and exhaust pressure rising. Reorientation by a TVS intermittent exhaust may be possible in some cases, with sufficient exhaust time. This study provides a theoretical basis for reorientation using the exhaust gas of liquid hydrogen.


  • Open Access

    The Mechanism Research of Low-Frequency Pressure Oscillation in the Feeding Pipe of Cryogenic Rocket Propulsion System

    by Chengfeng Zhu, Yanzhong Li, Fushou Xie, Lei Wang, Yuan Ma

    In the propulsion system of cryogenic liquid rockets, low-frequency pressure oscillation is a long-standing issue occurring in its feeding pipe, and is not conducive to the normal operation of the rocket. Its mechanism and excitation process are not very clear due to the limitation of the existing numerical method and the difficulty of the real dynamic experiment. Inspired by the periodic suck-back flow phenomenon of steam condensation, the fluctuation of the two-phase interface might be the crucial factor to initiate the low-frequency pressure oscillation. To simulate this interfacial characteristic of cryogenic propellant, a novel numerical model is proposed to predict the mass transfer rate weighted by the interfacial curvature. Aiming at the oxygen jet condensation simulation, the low-frequency pressure oscillation phenomenon is obtained successfully with the excitation frequency of 10.6 Hz, consistent with the natural frequency of the engine test run. It is conducted so the low-frequency pressure oscillation is caused by the periodic condensation of the continuous oxygen vapour plume, along with an oxygen suck-back flow phenomenon. In addition, the results indicate that both the oxygen and liquid oxygen mass flux promote the rise in the frequency of pressure oscillation. These conclusions provide theoretical instructions for the design and operation of the propulsion system of a cryogenic liquid rocket.


  • Open Access

    CFD Investigation on Movement Features of Hydrogen Bubble under Microgravity Environment

    by Lei Wang, Peijie Sun, Li Yan, Shi Shangguan, Miao Qu, Yanzhong Li

    A designed cryogenic upper stage adopted liquid hydrogen and liquid oxygen (LH2/LO2) as an aerospace propellant. During a zero-gravity coast period in space, the wall heat leakage into the delivery tube could induce liquid propellant evaporation and two-phase flow phenomenon, so that a bubble discharge operation must be employed prior to engine restart. In this study, a CFD approach was utilized to numerically study the bubble discharge behaviors inside the LH2 delivery tube of the upper stage. The bubble motion properties under two different schemes, including positive acceleration effect and circulation flow operation, were analyzed and discussed. The results showed that the boiled hydrogen bubbles could increase to the size of the tube inner diameter and distribute randomly within the entire tube volume, and that, in order for the bubble to spill upward under the acceleration effect, a higher acceleration level than the needed value of acquiring liquid–vapor separation inside the propellant tank should be provided. When creating an acceleration level of 10−3 g0, most of the bubbles could spill upward within 700 s. Significantly, the bubbles could not be completely expelled in the created acceleration condition since a number of small bubbles always stagnate in the bulk liquid region. In the circulation flow operation, the gas volume reduction was mainly attributed to two mechanisms: the vapor condensation effect; and bubble discharge effect. For the case with a circulation flow rate of 0.2 kg/s, a complete bubble discharge purpose was reached within 820 s, while a large bubble stagnation in the spherical distributor occupied a remarkable proportion of the total time. In addition, both the liquid flow rate and liquid subcooling exert important effects on bubble performance. When applying a high circulation flow, the gas volume reduction is mainly due to the inertial effect of liquid flow, but the bubble stagnation in the spherical distributor still affects the total discharge time. The liquid subcooling influence on the gas volume reduction is more significant in smaller circulation flow cases. Generally, the present study provides valuable conclusions on bubble motions inside a LH2 delivery tube in microgravity, and the results could be beneficial to the sequence design of engine restart for the cryogenic upper stage.