Otto J. Gregory
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Otto J. Gregory has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Matin Amani
University of Rhode Island
4 shared publicationsIan M. Tougas
Department of Chemical Engineering, University of Rhode Island, Kingston, RI, USA
3 shared publications- Kevin Rivera
Chemical engineering, University of Rhode Island, Kingston, Rhode Island United States 02881
3 shared publications Alvin J. Drehman
Air Force Research Laboratory Hanscom Air Force Base Bedford MA 01731
2 shared publications- Matin Amani
Department of Chemical Engineering, University of Rhode Island, 16 Greenhouse Road, Crawford Hall Room 205, Kingston, RI 02881, USA
2 shared publications - Peter P. Ricci
URI Sensors and Surface Technology Partnership and Department of Chemical Engineering, University of Rhode Island, Kingston, RI 02881, USA
2 shared publications
Latest Publications
- 9 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 20 (23) , 14058-14064
Continuous Monitoring of TATP Using Ultrasensitive, Low-Power Sensors
There is a growing need for a continuous monitoring system that can detect explosives such as triacetone triperoxide (TATP) in the vapor phase at trace levels. TATP is an energetic material commonly used by terrorists in improvised explosive devices both as the initiator and the energetic material itself. TATP is still going largely undetected in many densely populated venues such as train stations and airports. No electronic trace detection system currently exists that is capable of continuously monitoring TATP, or its precursors, in the vapor phase. Recently, we developed a thermodynamic sensor that can detect TATP and other nitrogen-based explosives in the vapor phase at the ppb level. These ultrathin sensors showed unparalleled sensitivity and could even be operated at low enough powers to enable them to be deployed on drones. The sensor relies on specific oxidation-reduction reactions between the energetic molecules and metal oxide catalysts. Here, catalyst coated microheaters measure the heat effects associated with redox reactions occurring on the surface of the metal oxide catalyst. Enhanced sensitivity and selectivity were achieved through implementation of ultrathin (8μm thick) yttria-stabilized-zirconia (YSZ) as the substrate for the sensor platform. This reduction in the thermal mass combined with the catalytic amplification associated with Pd microheaters and optimized catalyst porosity enabled us to detect TATP in the vapor phase at unprecedented levels.
- 9 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 20 (23) , 14058-14064
Continuous Monitoring of TATP Using Ultrasensitive, Low-Power Sensors
There is a growing need for a continuous monitoring system that can detect explosives such as triacetone triperoxide (TATP) in the vapor phase at trace levels. TATP is an energetic material commonly used by terrorists in improvised explosive devices both as the initiator and the energetic material itself. TATP is still going largely undetected in many densely populated venues such as train stations and airports. No electronic trace detection system currently exists that is capable of continuously monitoring TATP, or its precursors, in the vapor phase. Recently, we developed a thermodynamic sensor that can detect TATP and other nitrogen-based explosives in the vapor phase at the ppb level. These ultrathin sensors showed unparalleled sensitivity and could even be operated at low enough powers to enable them to be deployed on drones. The sensor relies on specific oxidation-reduction reactions between the energetic molecules and metal oxide catalysts. Here, catalyst coated microheaters measure the heat effects associated with redox reactions occurring on the surface of the metal oxide catalyst. Enhanced sensitivity and selectivity were achieved through implementation of ultrathin (8μm thick) yttria-stabilized-zirconia (YSZ) as the substrate for the sensor platform. This reduction in the thermal mass combined with the catalytic amplification associated with Pd microheaters and optimized catalyst porosity enabled us to detect TATP in the vapor phase at unprecedented levels.
- 7 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 4 (5) , 1-4
ITO:SiC Ceramic Matrix Composite Thermocouples for Engine Components
Surface temperature measurements of ceramic matrix composite (CMC) based engine components within the hot section of a gas turbine engines are needed to verify engine designs and cooling requirements. Traditional temperature sensors cannot be applied to SiC-based CMC's for this purpose, since they cannot be welded nor embedded in the material. For these reasons, a novel thermocouple was developed for surface temperature measurement of p-type SiC-SiC CMC's. This novel thermocouple uses the p-type SiC-SiC CMC itself as one of the thermoelements and indium-tin-oxide (ITO) as the other thermoelement. Since both thermoelements are wide bandgap semiconductors, this thermocouple has exceptional thermoelectric output. A thermoelectric power of 272μV/°K was observed for this ITO:SiC CMC thermocouple, which is an order of magnitude larger than type-K thermocouples. A drift rate of only 3.47°C/hr was measured for this ITO:SiC CMC thermocouple at 1000°C. In addition, ITON protective coatings enabled these thermocouples to operate at 1000°C. The ITON coatings served as oxygen diffusion barriers to prevent oxidation at the ITO:SiC junction. Nitrogen and air anneals at 550°C and 1000°C, respectively, were used to improve high temperature stability of the ITON protective coatings. Performance, fabrication details and challenges using these ITO:SiC CMC thermocouple are discussed within.
- 7 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 4 (5) , 1-4
ITO:SiC Ceramic Matrix Composite Thermocouples for Engine Components
Surface temperature measurements of ceramic matrix composite (CMC) based engine components within the hot section of a gas turbine engines are needed to verify engine designs and cooling requirements. Traditional temperature sensors cannot be applied to SiC-based CMC's for this purpose, since they cannot be welded nor embedded in the material. For these reasons, a novel thermocouple was developed for surface temperature measurement of p-type SiC-SiC CMC's. This novel thermocouple uses the p-type SiC-SiC CMC itself as one of the thermoelements and indium-tin-oxide (ITO) as the other thermoelement. Since both thermoelements are wide bandgap semiconductors, this thermocouple has exceptional thermoelectric output. A thermoelectric power of 272μV/°K was observed for this ITO:SiC CMC thermocouple, which is an order of magnitude larger than type-K thermocouples. A drift rate of only 3.47°C/hr was measured for this ITO:SiC CMC thermocouple at 1000°C. In addition, ITON protective coatings enabled these thermocouples to operate at 1000°C. The ITON coatings served as oxygen diffusion barriers to prevent oxidation at the ITO:SiC junction. Nitrogen and air anneals at 550°C and 1000°C, respectively, were used to improve high temperature stability of the ITON protective coatings. Performance, fabrication details and challenges using these ITO:SiC CMC thermocouple are discussed within.
- 2 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 3 (10) , 1-4
Orthogonal Sensors for the Trace Detection of Explosives
There is a growing need for an electronic trace detection (ETD) system that can continuously monitor explosives at trace levels in the vapor phase. Triacetone triperoxide (TATP) is a common explosive used by terrorists as the initiator or the energetic material in improvised explosive devices (IED's). TATP still goes largely undetected in many densely populated public venues. Currently, no detection system exists that is capable of continuously monitoring TATP as well as nitrogen-based explosives such as 2,4-dinitrotoluene. We have demonstrated a thermodynamic sensor platform employing thin film microheaters and metal oxide catalysts that can detect TATP and 2,4-DNT at the ppb level. The microheaters and catalysts were deposited onto ultrathin alumina ceramic substrates, which are responsible for extraordinary sensitivity. Recently, we have added a conductometric sensor platform to this thermodynamic platform to form an orthogonal sensor capable of interrogating the same catalyst using two different modalities. The orthogonal sensor probes the same catalyst using a thermodynamic protocol as well as a conductometric protocol where electrical resistivity changes in the catalyst are measured as a function of analyte exposure. The advantages of this added orthogonality in terms of mitigating false-positives and negatives are described within.
- 2 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 3 (10) , 1-4
Orthogonal Sensors for the Trace Detection of Explosives
There is a growing need for an electronic trace detection (ETD) system that can continuously monitor explosives at trace levels in the vapor phase. Triacetone triperoxide (TATP) is a common explosive used by terrorists as the initiator or the energetic material in improvised explosive devices (IED's). TATP still goes largely undetected in many densely populated public venues. Currently, no detection system exists that is capable of continuously monitoring TATP as well as nitrogen-based explosives such as 2,4-dinitrotoluene. We have demonstrated a thermodynamic sensor platform employing thin film microheaters and metal oxide catalysts that can detect TATP and 2,4-DNT at the ppb level. The microheaters and catalysts were deposited onto ultrathin alumina ceramic substrates, which are responsible for extraordinary sensitivity. Recently, we have added a conductometric sensor platform to this thermodynamic platform to form an orthogonal sensor capable of interrogating the same catalyst using two different modalities. The orthogonal sensor probes the same catalyst using a thermodynamic protocol as well as a conductometric protocol where electrical resistivity changes in the catalyst are measured as a function of analyte exposure. The advantages of this added orthogonality in terms of mitigating false-positives and negatives are described within.
- 10 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 2 (3) , 1-4
Strain Gages for SiC–SiC Ceramic Matrix Composite Engine Components
As more and more SiC-SiC ceramic matrix composites or CMC's are being used in the hot sections of gas turbine engines, there is a greater need for in-situ strain measurement in these harsh conditions. Thin film strain sensors are ideally suited for this task since they have minimal mass and are nonintrusive. However, if the bulk piezoresistive properties of SiC-SiC CMC's could be used instead of the thin film piezoresistive properties, superior resolution and stability could be realized. Toward this end, we have fabricated strain gages in which the active strain element is the SiC-SiC CMC itself. As a result of this approach, a Pt:SiC CMC strain gage capable of operating at 500C for prolonged periods was demonstrated. The large piezoresistive responses associated with the SiC fibers and SiC matrix resulted in gage factors larger than 100.Performance of the Pt:SiC CMC strain gages under both tension and compression are reported and the IV characteristics of the strain gages as well as the piezoresistive response as a function of temperature are presented. In addition, the potential for embedded strain gages in advanced CMC engine components will be discussed.
- 10 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 2 (3) , 1-4
Strain Gages for SiC–SiC Ceramic Matrix Composite Engine Components
As more and more SiC-SiC ceramic matrix composites or CMC's are being used in the hot sections of gas turbine engines, there is a greater need for in-situ strain measurement in these harsh conditions. Thin film strain sensors are ideally suited for this task since they have minimal mass and are nonintrusive. However, if the bulk piezoresistive properties of SiC-SiC CMC's could be used instead of the thin film piezoresistive properties, superior resolution and stability could be realized. Toward this end, we have fabricated strain gages in which the active strain element is the SiC-SiC CMC itself. As a result of this approach, a Pt:SiC CMC strain gage capable of operating at 500C for prolonged periods was demonstrated. The large piezoresistive responses associated with the SiC fibers and SiC matrix resulted in gage factors larger than 100.Performance of the Pt:SiC CMC strain gages under both tension and compression are reported and the IV characteristics of the strain gages as well as the piezoresistive response as a function of temperature are presented. In addition, the potential for embedded strain gages in advanced CMC engine components will be discussed.
- Open Access
A Review of Tunable Wavelength Selectivity of Metamaterials in Near-Field and Far-Field Radiative Thermal Transport
Radiative thermal transport of metamaterials has begun to play a significant role in thermal science and has great engineering applications. When the key features of structures become comparable to the thermal wavelength at a particular temperature, a narrowband or wideband of wavelengths can be created or shifted in both the emission and reflection spectrum of nanoscale metamaterials. Due to the near-field effect, the phenomena of radiative wavelength selectivity become significant. These effects show strong promise for applications in thermophotovoltaic energy harvesting, nanoscale biosensing, and increased energy efficiency through radiative cooling in the near future. This review paper summarizes the recent progress and outlook of both near-field and far-field radiative heat transfer, different design structures of metamaterials, applications of unique thermal and optical properties, and focuses especially on exploration of the tunable radiative wavelength selectivity of nano-metamaterials.
Open AccessA Review of Tunable Wavelength Selectivity of Metamaterials in Near-Field and Far-Field Radiative Thermal Transport
Radiative thermal transport of metamaterials has begun to play a significant role in thermal science and has great engineering applications. When the key features of structures become comparable to the thermal wavelength at a particular temperature, a narrowband or wideband of wavelengths can be created or shifted in both the emission and reflection spectrum of nanoscale metamaterials. Due to the near-field effect, the phenomena of radiative wavelength selectivity become significant. These effects show strong promise for applications in thermophotovoltaic energy harvesting, nanoscale biosensing, and increased energy efficiency through radiative cooling in the near future. This review paper summarizes the recent progress and outlook of both near-field and far-field radiative heat transfer, different design structures of metamaterials, applications of unique thermal and optical properties, and focuses especially on exploration of the tunable radiative wavelength selectivity of nano-metamaterials.
- 9 June 2017
- Published by Springer Nature in Journal of Materials Research
- Vol. 32 (17) , 3319-3325
Novel temperature sensors for SiC–SiC CMC engine components
- 9 June 2017
- Published by Springer Nature in Journal of Materials Research
- Vol. 32 (17) , 3319-3325
Novel temperature sensors for SiC–SiC CMC engine components
- Open Access
Metallic and Ceramic Thin Film Thermocouples for Gas Turbine Engines
Temperatures of hot section components in today’s gas turbine engines reach as high as 1,500 °C, making in situ monitoring of the severe temperature gradients within the engine rather difficult. Therefore, there is a need to develop instrumentation (i.e., thermocouples and strain gauges) for these turbine engines that can survive these harsh environments. Refractory metal and ceramic thin film thermocouples are well suited for this task since they have excellent chemical and electrical stability at high temperatures in oxidizing atmospheres, they are compatible with thermal barrier coatings commonly employed in today’s engines, they have greater sensitivity than conventional wire thermocouples, and they are non-invasive to combustion aerodynamics in the engine. Thin film thermocouples based on platinum:palladium and indium oxynitride:indium tin oxynitride as well as their oxide counterparts have been developed for this purpose and have proven to be more stable than conventional type-S and type-K thin film thermocouples. The metallic and ceramic thin film thermocouples described within this paper exhibited remarkable stability and drift rates similar to bulk (wire) thermocouples.
Open AccessMetallic and Ceramic Thin Film Thermocouples for Gas Turbine Engines
Temperatures of hot section components in today’s gas turbine engines reach as high as 1,500 °C, making in situ monitoring of the severe temperature gradients within the engine rather difficult. Therefore, there is a need to develop instrumentation (i.e., thermocouples and strain gauges) for these turbine engines that can survive these harsh environments. Refractory metal and ceramic thin film thermocouples are well suited for this task since they have excellent chemical and electrical stability at high temperatures in oxidizing atmospheres, they are compatible with thermal barrier coatings commonly employed in today’s engines, they have greater sensitivity than conventional wire thermocouples, and they are non-invasive to combustion aerodynamics in the engine. Thin film thermocouples based on platinum:palladium and indium oxynitride:indium tin oxynitride as well as their oxide counterparts have been developed for this purpose and have proven to be more stable than conventional type-S and type-K thin film thermocouples. The metallic and ceramic thin film thermocouples described within this paper exhibited remarkable stability and drift rates similar to bulk (wire) thermocouples.
- 1 November 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 65 (19300395) , 1-4
Metallic and ceramic thin film thermocouples for gas turbine engine applications
Hot section temperatures in gas turbine engines can reach 1500°C, an environment in which implementing sensors for in situ measurement is rather difficult. Therefore, there is a need to develop instrumentation for these turbine engines that can survive the harsh conditions. Thin film instrumentation is targeted for this purpose because it is non-invasive to the physical and thermodynamic properties of the engine components. Type-S and type-K thin film and wire thermocouples are currently being utilized for surface temperature measurement during the testing phase of gas turbine engines. These metallic thin film thermocouples suffer from drift and degradation due to microstructural changes and oxidation. Therefore, thin film thermocouples based alternatively on platinum:palladium and indium oxynitride:indium tin oxynitride, as well as their oxide counterparts, have been developed and proved to be more stable than conventional type-S and type-K thin film thermocouples operating in these high temperature (> 1000°C) oxidizing environments. Furthermore, the metallic and ceramic thin film thermocouples described within this paper exhibited remarkable stability and have drift rates similar to bulk (wire) thermocouples operating in the same temperature range.
- 1 November 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 65 (19300395) , 1-4
Metallic and ceramic thin film thermocouples for gas turbine engine applications
Hot section temperatures in gas turbine engines can reach 1500°C, an environment in which implementing sensors for in situ measurement is rather difficult. Therefore, there is a need to develop instrumentation for these turbine engines that can survive the harsh conditions. Thin film instrumentation is targeted for this purpose because it is non-invasive to the physical and thermodynamic properties of the engine components. Type-S and type-K thin film and wire thermocouples are currently being utilized for surface temperature measurement during the testing phase of gas turbine engines. These metallic thin film thermocouples suffer from drift and degradation due to microstructural changes and oxidation. Therefore, thin film thermocouples based alternatively on platinum:palladium and indium oxynitride:indium tin oxynitride, as well as their oxide counterparts, have been developed and proved to be more stable than conventional type-S and type-K thin film thermocouples operating in these high temperature (> 1000°C) oxidizing environments. Furthermore, the metallic and ceramic thin film thermocouples described within this paper exhibited remarkable stability and have drift rates similar to bulk (wire) thermocouples operating in the same temperature range.
- 1 September 2013
- Published by Elsevier in Thin Solid Films
- Vol. 542, 180-185
Grain growth and morphology of In2O3:Pd nanocomposite films
- 1 September 2013
- Published by Elsevier in Thin Solid Films
- Vol. 542, 180-185
Grain growth and morphology of In2O3:Pd nanocomposite films
- 27 October 2012
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 42 (1) , 114-120
High-Temperature Thermoelectric Properties of Compounds in the System Zn x In y O x+1.5y
- 27 October 2012
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 42 (1) , 114-120
High-Temperature Thermoelectric Properties of Compounds in the System Zn x In y O x+1.5y