TSTaku Suzuki

Taku Suzuki

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Taku Suzuki has a total of 116 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Occult Compression at the Pectoralis Minor-Second Rib Level After Cervical and First Rib Resection for Thoracic Outlet Syndrome

    by Kosuke Okina, Taku Suzuki, Yasuhiro Kiyota, Noboru Matsumura, Takuji Iwamoto, Masaya Nakamura

    Case: A 29-year-old woman with neurogenic thoracic outlet syndrome associated with a cervical rib underwent supraclavicular cervical and first rib resection; however, her symptoms persisted. Postoperative imaging revealed previously unrecognized compression at the pectoralis minor-second rib level that became apparent after initial decompression. Infraclavicular pectoralis minor release combined with second rib resection resulted in near-complete resolution of symptoms at 18 months after reoperation without complications. Conclusion: This case demonstrates that persistent symptoms after cervical rib surgery may reflect occult compression of the brachial plexus. Careful reassessment of the pectoralis minor-second rib region should be considered when outcomes after initial decompression are suboptimal.

  • Open Access

    Quantitative assessment of ulnohumeral instability after K-NOW unlinked total elbow arthroplasty using the helical axis: a pilot study

    by Yutaro Sugiura, Takuji Iwamoto, Yuka Matsumoto, Yasuhiro Kiyota, Taku Suzuki, Takeo Nagura, Naomichi Ogihara, Masaya Nakamura

  • Open Access

    Three‐Dimensional Magnetic Resonance Imaging of Median Nerve Volume for Assessing Carpal Tunnel Syndrome Severity

    by Kazuki Hayakawa, Taku Suzuki, Katsuhiko Hayakawa, Yusuke Kawano, Takuji Iwamoto, Nobuyuki Fujita

    Introduction/Aims: 3D magnetic resonance imaging (MRI) is a tool for visualizing and quantifying the volume of the median nerve; however, the diagnostic value of the volume of the median nerve for assessing CTS severity is unclear. This study aimed to evaluate the utility of 3T MRI combined with three‐dimensional (3D) imaging to assess the cross‐sectional volume (CSV) of the median nerve for diagnosing carpal tunnel syndrome (CTS) and determining its severity. Methods: We used MRI to measure the CSV of the median nerve in 95 patients with CTS and 26 healthy controls. CTS severity was graded according to the Padua classification, and differences in CSV according to severity were analyzed. Results: The mean CSVs for the severity groups were as follows: control, 22.4 mm 3 ; minimal, 28.8 mm 3 ; moderate, 34.4 mm 3 ; severe, 53.6 mm 3 ; and extreme, 48.3 mm 3 . CSV increased with CTS severity, with significantly higher values in the severe and extreme groups compared with the moderate, minimal, and control groups. Discussion: This study showed that the CSV of the median nerve increased with disease severity, both visually and in three dimensions. This helps to visually understand the severity of CTS, and the association between morphology and disease severity may contribute to a better understanding of the pathophysiology of CTS.


  • Anatomical Reconstruction of the Terminal Tendon and Lateral Band for Severe Chronic Tendon Mallet Injury

    by Taku Suzuki, Yasuhiro Kiyota, Noboru Matsumura, Kazuki Sato, Masaya Nakamura, Takuji Iwamoto


  • Open Access

    Improvement in Chest Pain Following Surgical Treatment for Thoracic Outlet Syndrome

    by Shutaro Makita, Taku Suzuki, Yasuhiro Kiyota, Noboru Matsumura, Takuji Iwamoto, Masaya Nakamura

    A 41-year-old woman with a 1-year history of right chest pain, with normal cardiology and pulmonology assessments. The chest pain was reproducible upon upper limb elevation. Computed tomography (CT) angiography in the arm-elevated position revealed subclavian artery and vein stenosis at the costoclavicular space, and the diagnosis was neurogenic thoracic outlet syndrome (TOS). Surgery involving endoscopic-assisted infraclavicular resection of the first rib and scalene muscles resulted in immediate postoperative symptom improvement. When chest pain persists after ruling out other conditions, neurogenic TOS should be considered in the differential diagnosis.

  • Open Access

    Prospective Study on Splinting for First Carpometacarpal Joint: A Comparison of Conventional and Three-Dimensional Printed Splint

    by Naoto Inaba, Takuji Iwamoto, Kazunori Ishii, Satoshi Oki, Taku Suzuki, Kazuki Sato, Takeo Nagura, Masaya Nakamura

    Background: Patient compliance is a major concern of hand orthosis in first carpometacarpal osteoarthritis. To address this issue, we established a method for creating a custom-made three-dimensional printed splint based on computed tomography. This prospective study evaluates the usefulness of the three-dimensional printed splint compared with the conventional splint. Methods: A total of 12 hands in nine patients were included. The mean age of the patients was 69 years (range: 58–84). Conventional orthoses were made by prosthetists using molds. Three-dimensional printed orthoses (long and short types) were digitally designed from computed tomography data and created using Fused Deposition Modeling. Subjects were instructed to use three types of orthoses for 2 weeks each. They completed questionnaires that indicated pain, function, percentage of daytime spent using the orthosis, satisfaction score, and discomfort caused by wearing orthoses. Results: The pain on motion showed an improvement of approximately 20% for all orthoses. There was no significant difference in pain scale, function, percentages of daytime spent using each orthosis, and satisfaction score among the three types of orthoses. Discomfort caused by wearing orthosis was more frequent in conventional orthosis than in 3D-printed orthosis, and there was a significant difference between the conventional type and the long-type 3D-printed orthosis. Conclusions: This study suggests that 3D-printed splints provide comparable pain relief to conventional splints with reduced discomfort. However, limitations such as small sample size, short follow-up, and reliance on CT imaging highlight the need for further research.


  • Endoscopic-Assisted Infraclavicular Approach for Hypoplastic First Rib Resection in Thoracic Outlet Syndrome

    by Masato Fumoto, Taku Suzuki, Yasuhiro Kiyota, Noboru Matsumura, Takuji Iwamoto, Masaya Nakamura

    Case: A 25-year-old man presented with neck and upper-limb pain. He underwent surgery for the resection of a left hypoplastic first rib, which was causing thoracic outlet syndrome. The subclavian vein was retracted through an infraclavicular incision, and an endoscope was inserted dorsally to the vein. With the assistance of endoscopy, the first rib was partially resected, and scalene muscles were released from the rib. The preoperative symptoms improved after surgery without any complications. Conclusion: The endoscopic-assisted infraclavicular approach enabled sufficient resection of the hypoplastic first rib, leading to satisfactory outcomes. This method can be considered as an option for resecting a hypoplastic first rib.


  • Open Access

    Three-dimensional Visualization of the Brachial Plexus

    by Taku Suzuki, Katsuhiko Hayakawa, Takuji Iwamoto

    Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.


  • Modified Intravascular Stent for Microvascular Suture in a Rat Superficial Femoral Artery

    by Kosuke Maeda, Taku Suzuki, Yohei Masugi, Osahiko Tsuji, Takuji Iwamoto, Masaya Nakamura

    Background: Intravascular stent (IVaS) is sometimes used for suturing small vessels, but removing the stent after suturing is difficult. To overcome this problem, we developed an IVaS that integrates a stent and a manipulating string. This study aimed to investigate the usefulness of the modified IVaS (M-IVaS) by comparing it with conventional sutures (CS) and conventional IVaS (C-IVaS). Methods: Forty-five superficial femoral arteries from rats were resected and sutured. The rats were randomly divided into the following 3 groups: CS, M-IVaS, and C-IVaS, with 15 rats per group. Patency rate, operating time, and ultrasonographic blood flow dynamics were examined immediately after suturing. Patency tests, ultrasonographic evaluations, and histological investigations were performed 1 week (n = 5), 2 weeks (n = 5), and 6 weeks (n = 5) after surgery. Results: The 3 groups showed vessel patency in all cases immediately after suturing and at 1 week, 2 weeks, and 6 weeks after surgery. The mean operative time was 22.6 minutes for the CS group, 21.5 minutes for the M-IVaS group, and 25.9 minutes for the C-IVaS group. There were no significant differences in peak flow velocity and stenosis rate among the 3 groups as evaluated by ultrasonography. Histopathological evaluation revealed a similar recovery process of endothelial cells and no damage to the vascular wall. Conclusion: The surgical time using M-IVaS was significantly shorter compared to that using C-IVaS. The M-IVaS reduced the inconvenience of C-IVaS removal. M-IVaS showed the same effectiveness as did the CS in terms of patency rate, operating time, ultrasonographic blood flow dynamics, and histological evaluation. M-IVaS can be used in the field of microsurgery.


  • Open Access

    A case of concomitant subclavian steal syndrome and thoracic outlet syndrome

    by Akihiro Kageyama, Taku Suzuki, Yasuhiro Kiyota, Noboru Matsumura, Takuji Iwamoto, Masaya Nakamura