Mahdi Bahadoran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mahdi Bahadoran has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Ahmad Fakhrurrazi Ahmad Noorden
Centre for Advanced Optoelectronics Research (CAPTOR), Kulliyah of Science, International Islamic University Malaysia, 25200 Kuantan, Pahang, Malaysia
4 shared publications - Preecha P. Yupapin
Department of Electrical Technology, Sakonnakhon Technical College, School of Industrial Technology, Institute of Vocational Education, Sakonnahkon, Thailand
4 shared publications Abbas Kalate Seyfari
Department of Physics, Shiraz University of Technology, Shiraz, Iran
3 shared publications- Iraj Sadegh Amiri
Ton Duc Thang University
3 shared publications - Amir Hadi Ziaie
Research Institute for Astronomy and Astrophysics of Maragha (RIAAM) University of Maragheh P. O. Box 55136 -553 Maragheh Iran
2 shared publications Faezeh Pakfetrat
Department of Physics, Shiraz University of Technology, Shiraz Iran
2 shared publications
Latest Publications
- 17 September 2025
- Published by Springer Nature in Iranian Journal of Science
- Vol. 50 (2) , 921-928
Designing of a Circular Photonic Crystal Fiber to Support Higher-Order Orbital Angular Momentum Modes for Telecommunication Applications
- 17 September 2025
- Published by Springer Nature in Iranian Journal of Science
- Vol. 50 (2) , 921-928
Designing of a Circular Photonic Crystal Fiber to Support Higher-Order Orbital Angular Momentum Modes for Telecommunication Applications
- Open Access
- 29 August 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-16
Design and modeling of eye-shaped double-slot GaAs microring resonator for CO2 sensing
Monitoring of CO2 is crucial because of its profound impact on both environmental and human health. A novel highly sensitive refractive index (RI) sensor, utilizing a double-slot microring resonating structure, has been designed and numerically assessed for the sensitive detection of gas media. The structure consisted of a circular microring resonator nested in a racetrack resonating configuration mimicking the structure of an eye-shaped microring resonator (ESMRR). This system was simulated and designed for a GaAs double-slot core waveguide deposited on a suitable Al0.5Ga0.5As substrate. Optical transfer function of ESMRR and related equations were derived using Mason rule, while the numerical analysis was performed using the variational finite difference time domain (var- FDTD) method. The free spectral range (FSR) was extended to 137.68 nm that led to a remarkable bulk sensitivity of 1217.39 nm/RIU and a resolution of 4.93 × 10−6 RIU. The proposed sensing structure was envisioned for CO2 sensing and demonstrated an impressive sensitivity of 24.4 pm/ppm for CO2 detection with an estimated detection limit of 0.82 ppm.
- 29 August 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-16
Open AccessDesign and modeling of eye-shaped double-slot GaAs microring resonator for CO2 sensing
Monitoring of CO2 is crucial because of its profound impact on both environmental and human health. A novel highly sensitive refractive index (RI) sensor, utilizing a double-slot microring resonating structure, has been designed and numerically assessed for the sensitive detection of gas media. The structure consisted of a circular microring resonator nested in a racetrack resonating configuration mimicking the structure of an eye-shaped microring resonator (ESMRR). This system was simulated and designed for a GaAs double-slot core waveguide deposited on a suitable Al0.5Ga0.5As substrate. Optical transfer function of ESMRR and related equations were derived using Mason rule, while the numerical analysis was performed using the variational finite difference time domain (var- FDTD) method. The free spectral range (FSR) was extended to 137.68 nm that led to a remarkable bulk sensitivity of 1217.39 nm/RIU and a resolution of 4.93 × 10−6 RIU. The proposed sensing structure was envisioned for CO2 sensing and demonstrated an impressive sensitivity of 24.4 pm/ppm for CO2 detection with an estimated detection limit of 0.82 ppm.
- 18 August 2025
- Published by Elsevier in Journal of Thermal Biology
- Vol. 132, 104247
Numerical analysis of microwave and radiofrequency ablations: A novel design for electrode-based radiofrequency ablation
- 18 August 2025
- Published by Elsevier in Journal of Thermal Biology
- Vol. 132, 104247
Numerical analysis of microwave and radiofrequency ablations: A novel design for electrode-based radiofrequency ablation
- 2 July 2025
- Published by Springer Nature
- p. 113-120
Label Free Optical Biosensor of Cancer Cells Using Two Single-Slot GaAs Microring Resonators
- 2 July 2025
- Published by Springer Nature
- p. 113-120
Label Free Optical Biosensor of Cancer Cells Using Two Single-Slot GaAs Microring Resonators
- 11 November 2024
- Published by Springer Nature in Sensing and Imaging
- Vol. 25 (1) , 1-15
Selective Detection of Avian Influenza Virus Subtypes in the Terahertz Region Using Array of Gold Cross-shaped Absorber
- 11 November 2024
- Published by Springer Nature in Sensing and Imaging
- Vol. 25 (1) , 1-15
Selective Detection of Avian Influenza Virus Subtypes in the Terahertz Region Using Array of Gold Cross-shaped Absorber
- Open Access
- 9 August 2024
- Published by Springer Nature in Research Square
Numerical analysis of microwave and radiofrequency ablations: A novel design for electrode-based radiofrequency ablation
Thermal ablation is atreatment modality for liver cancer that utilizes heat to destroy cancerous tissues. The numerical analysis of thermal ablation processes in liver tissue was studied using two different methods: microwave ablation (MWA) and radiofrequency ablation (RFA). The effectiveness of both methods and the thermal characteristics of tumor ablation, including temperature distribution, temporal variation intemperature, volume of ablation, and destruction of cancerous tissue, were investigated. MWA requires less time for complete ablation than RFA and can generate larger ablation zones. Additionally, a novel electrode-based design for RFA, we call it Norfolk pine electrode (NPE), which focuses on ablating large and spherical tumors, has been proposed and analyzed. To the best of our knowledge, the conventional RFA designs, which utilize the Christmas tree electrode and umbrella electrode, are effective in ablating tumors smaller than 3 cm . However, they fail to completely eradicatespherical tumors. Interestingly, our proposed NPE claims the ability to fully ablate spherical tumors, even those larger than 3 cm . This NPE could be a promising and practical advancement in the realm of tumor treatment.
- 9 August 2024
- Published by Springer Nature in Research Square
Open AccessNumerical analysis of microwave and radiofrequency ablations: A novel design for electrode-based radiofrequency ablation
Thermal ablation is atreatment modality for liver cancer that utilizes heat to destroy cancerous tissues. The numerical analysis of thermal ablation processes in liver tissue was studied using two different methods: microwave ablation (MWA) and radiofrequency ablation (RFA). The effectiveness of both methods and the thermal characteristics of tumor ablation, including temperature distribution, temporal variation intemperature, volume of ablation, and destruction of cancerous tissue, were investigated. MWA requires less time for complete ablation than RFA and can generate larger ablation zones. Additionally, a novel electrode-based design for RFA, we call it Norfolk pine electrode (NPE), which focuses on ablating large and spherical tumors, has been proposed and analyzed. To the best of our knowledge, the conventional RFA designs, which utilize the Christmas tree electrode and umbrella electrode, are effective in ablating tumors smaller than 3 cm . However, they fail to completely eradicatespherical tumors. Interestingly, our proposed NPE claims the ability to fully ablate spherical tumors, even those larger than 3 cm . This NPE could be a promising and practical advancement in the realm of tumor treatment.
- 20 June 2023
- Published by IOP Publishing in Physica Scripta
- Vol. 98 (7) , 079501
Corrigendum: high photoluminescence intensity of heterostructure AlGaN-based DUV-LED through uniform carrier distribution (2023 Phys. Scr. 98 015503)
- 20 June 2023
- Published by IOP Publishing in Physica Scripta
- Vol. 98 (7) , 079501
Corrigendum: high photoluminescence intensity of heterostructure AlGaN-based DUV-LED through uniform carrier distribution (2023 Phys. Scr. 98 015503)
- 1 December 2022
- Published by IOP Publishing in Physica Scripta
- Vol. 98 (1) , 015503
High photoluminescence intensity of heterostructure AlGaN-based DUV-LED through uniform carrier distribution
We report a numerical analysis of the variation of Aluminium (Al) composition in Al Gallium Nitride (AlGaN)-based Deep-Ultraviolet Light-Emitting Diode (DUV-LED) and its effects on the carrier concentration, radiative recombination, and photoluminescence (PL). Three different structures with different Al compositions are compared and analyzed. The radiative recombination of the DUV-LED is less efficient due to the imbalance of carrier distribution. The findings show that the uniform electrons and holes distribution significantly improve the radiative recombination for structure with a thin step-shaped quantum well (QW). The simulated structure emits a wavelength of 302.874 nm, categorized in the ultraviolet-B (UV-B) spectrum. Our results imply that carrier uniformity in QW is required to enhance the light intensity of DUV-LED. Remarkably, the uniformity enhances the PL intensity drastically, at least six times higher than the first structure and twice higher than the second structure.
- 1 December 2022
- Published by IOP Publishing in Physica Scripta
- Vol. 98 (1) , 015503
High photoluminescence intensity of heterostructure AlGaN-based DUV-LED through uniform carrier distribution
We report a numerical analysis of the variation of Aluminium (Al) composition in Al Gallium Nitride (AlGaN)-based Deep-Ultraviolet Light-Emitting Diode (DUV-LED) and its effects on the carrier concentration, radiative recombination, and photoluminescence (PL). Three different structures with different Al compositions are compared and analyzed. The radiative recombination of the DUV-LED is less efficient due to the imbalance of carrier distribution. The findings show that the uniform electrons and holes distribution significantly improve the radiative recombination for structure with a thin step-shaped quantum well (QW). The simulated structure emits a wavelength of 302.874 nm, categorized in the ultraviolet-B (UV-B) spectrum. Our results imply that carrier uniformity in QW is required to enhance the light intensity of DUV-LED. Remarkably, the uniformity enhances the PL intensity drastically, at least six times higher than the first structure and twice higher than the second structure.
- 25 November 2022
- Published by IOP Publishing in Physica Scripta
- Vol. 97 (12) , 125102
Tunable broad-band absorber consisted of crossed-oval shape of graphene
A three-dimensional broadband absorber structure was proposed based on the crossed-oval shape of graphene (COSG) on a wafer layout. This structure consisted of silicon/gold/silica wafer and a superstrate layer of graphene patterns in the form of crossed-oval placed on top of the wafer. The effect of geometrical parameters on the absorption was studied. Results show that this structure can absorb over 99% of the incoming light over a broad range of THz frequencies. The absorption peaks were fine-tuned by changing the geometrical and physical parameters. This property is vital and desirable in optical detectors, chemical sensors, and other optical devices.
- 25 November 2022
- Published by IOP Publishing in Physica Scripta
- Vol. 97 (12) , 125102
Tunable broad-band absorber consisted of crossed-oval shape of graphene
A three-dimensional broadband absorber structure was proposed based on the crossed-oval shape of graphene (COSG) on a wafer layout. This structure consisted of silicon/gold/silica wafer and a superstrate layer of graphene patterns in the form of crossed-oval placed on top of the wafer. The effect of geometrical parameters on the absorption was studied. Results show that this structure can absorb over 99% of the incoming light over a broad range of THz frequencies. The absorption peaks were fine-tuned by changing the geometrical and physical parameters. This property is vital and desirable in optical detectors, chemical sensors, and other optical devices.
- 7 April 2022
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 137 (4) , 1-10
Micro-opto-mechanical pressure sensor via ring resonator-based Mach–Zehnder interferometer
- 7 April 2022
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 137 (4) , 1-10
Micro-opto-mechanical pressure sensor via ring resonator-based Mach–Zehnder interferometer