Xuelin Dong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xuelin Dong has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
Deli Gao
Key Laboratory of Petroleum Engineering China University of Petroleum Beijing China
5 shared publications- Zhiyin Duan
Beijing Key Lab of Heating, Gas Supply, Ventilating and Air Conditioning Engineering, Beijing University of Civil Engineering and Architecture, Beijing 100044, China
5 shared publications Zhiyin Duan
4 shared publicationsJieli Wang
Key Laboratory of Petroleum Engineering China University of Petroleum Beijing China
3 shared publications- Yinji Ma
Laboratory of Flexible Electronics Technology, Tsinghua University, Beijing, China
3 shared publications - Deli Gao
China Univ Petr, Coll Petr Engn, Beijing 102249, Peoples R China
2 shared publications
Latest Publications
- Open Access
- 29 January 2025
- Published by Wiley in Energy Science & Engineering
- Vol. 13 (3) , 1425-1438
Sustained Casing Pressure Assessment Based on Gas Leakage Rate by the State of Equation for Real Gas
Gas leakage is one of the most concerning issues in wells for exploring conventional or unconventional oil and gas reservoirs, carbon sequestration, and geothermal energy. Wellbore barriers, such as tubing, casing, and cement, are the primary components that prevent the undesirable flow of subsurface fluids. However, due to the complexity of the operating condition in a harsh environment, the tubing integrity is prone to failure, causing gas leakage and forming a sustained casing pressure (SCP) at the wellhead. This work proposes a prediction model considering the real gas effect when evaluating SCP. The proposed model involves gas flow, leakage, and accumulation in the wellbore. With the pressure and temperature obtained by the flow equations as boundaries, the model estimates the gas flow rate at the leakage point and SCP. Subsequently, comparing the current leakage model with the conventional method demonstrates the model's performance. Finally, the current model is applied to an ultra‐deep well to determine the leakage location by inversion. Further sensitivity studies reveal the influences of wellbore conditions on SCP, including the production rate, depth of liquid level, and annular fluid density. The study indicates that the traditional method based on ideal gas underestimates the mass flow rate by approximately 22% compared to the current model. When the adiabatic index of the conventional method is approximated as the isentropic coefficient, the mass flow rate may agree well with the current model. It is acceptable to predict the leakage flow rate by assuming that the production gas is pure methane and ignoring the influence of gas composition. The leakage position is the most influential factor for SCP. These results would help engineers predict SCP and determine the leakage location in wells.
- 29 January 2025
- Published by Wiley in Energy Science & Engineering
- Vol. 13 (3) , 1425-1438
Open AccessSustained Casing Pressure Assessment Based on Gas Leakage Rate by the State of Equation for Real Gas
Gas leakage is one of the most concerning issues in wells for exploring conventional or unconventional oil and gas reservoirs, carbon sequestration, and geothermal energy. Wellbore barriers, such as tubing, casing, and cement, are the primary components that prevent the undesirable flow of subsurface fluids. However, due to the complexity of the operating condition in a harsh environment, the tubing integrity is prone to failure, causing gas leakage and forming a sustained casing pressure (SCP) at the wellhead. This work proposes a prediction model considering the real gas effect when evaluating SCP. The proposed model involves gas flow, leakage, and accumulation in the wellbore. With the pressure and temperature obtained by the flow equations as boundaries, the model estimates the gas flow rate at the leakage point and SCP. Subsequently, comparing the current leakage model with the conventional method demonstrates the model's performance. Finally, the current model is applied to an ultra‐deep well to determine the leakage location by inversion. Further sensitivity studies reveal the influences of wellbore conditions on SCP, including the production rate, depth of liquid level, and annular fluid density. The study indicates that the traditional method based on ideal gas underestimates the mass flow rate by approximately 22% compared to the current model. When the adiabatic index of the conventional method is approximated as the isentropic coefficient, the mass flow rate may agree well with the current model. It is acceptable to predict the leakage flow rate by assuming that the production gas is pure methane and ignoring the influence of gas composition. The leakage position is the most influential factor for SCP. These results would help engineers predict SCP and determine the leakage location in wells.
- 3 January 2025
- Published by Springer Nature
- p. 133-140
Collapse Failure of Tubular Elements in Ultra-Deep Wells Under Complex Conditions
- 3 January 2025
- Published by Springer Nature
- p. 133-140
Collapse Failure of Tubular Elements in Ultra-Deep Wells Under Complex Conditions
- 3 January 2025
- Published by Springer Nature
- p. 141-148
Temperature Evolution in Tar-Rich Coal Under Radiofrequency Heating
- 3 January 2025
- Published by Springer Nature
- p. 141-148
Temperature Evolution in Tar-Rich Coal Under Radiofrequency Heating
- 3 December 2024
- Published by Springer Nature
- p. 245-257
Experimental Study on the Effect of Moisture in Coal Seam for the Heating Rate Under RF Heating
- 3 December 2024
- Published by Springer Nature
- p. 245-257
Experimental Study on the Effect of Moisture in Coal Seam for the Heating Rate Under RF Heating
- Open Access
- 2 November 2024
- Published by MDPI AG in Sustainability
- Vol. 16 (21) , 9565
Energy-Saving Potential of Building-Integrated Photovoltaic Technology Applied to a Library in Changsha, China
With the increasing number of public buildings worldwide, their energy consumption has garnered significant attention. This study aims to promote building energy efficiency and emission reduction by exploring the application of Building-Integrated Photovoltaic technology in library retrofitting. Using a library in Changsha City as a case study, we conducted an energy consumption analysis of the building’s envelope and identified the window section as the highest energy consumer. We proposed a novel improvement scheme—the sun-shading photovoltaic panel (which shades the sun while generating electricity). Additionally, we utilized the roof space for the installation of conventional photovoltaic panels. Simultaneously, the primary objective of this paper was to derive a renovation strategy for public buildings in regions characterized by high summer temperatures and low winter temperatures based on the renovation case of this library. This paper comprehensively investigates the length and angle of sun-shading photovoltaic panels facing different directions, as well as the azimuth angle, tilt angle, and installation spacing of the conventional photovoltaic panels on the roof. Two retrofitting schemes were proposed. Through simulation and comparison, the second scheme was found to reduce the annual electricity consumption by 1,233,354 kWh, achieving a 35.4% decrease compared to the original building. Using the Changsha library as a template for public buildings, this study provided a retrofitting approach with Building-Integrated Photovoltaic technology via DesignBuilder, which could be extended to other geographic locations. The results demonstrated the significant energy-saving effects of the proposed retrofitting scheme.
- 2 November 2024
- Published by MDPI AG in Sustainability
- Vol. 16 (21) , 9565
Open AccessEnergy-Saving Potential of Building-Integrated Photovoltaic Technology Applied to a Library in Changsha, China
With the increasing number of public buildings worldwide, their energy consumption has garnered significant attention. This study aims to promote building energy efficiency and emission reduction by exploring the application of Building-Integrated Photovoltaic technology in library retrofitting. Using a library in Changsha City as a case study, we conducted an energy consumption analysis of the building’s envelope and identified the window section as the highest energy consumer. We proposed a novel improvement scheme—the sun-shading photovoltaic panel (which shades the sun while generating electricity). Additionally, we utilized the roof space for the installation of conventional photovoltaic panels. Simultaneously, the primary objective of this paper was to derive a renovation strategy for public buildings in regions characterized by high summer temperatures and low winter temperatures based on the renovation case of this library. This paper comprehensively investigates the length and angle of sun-shading photovoltaic panels facing different directions, as well as the azimuth angle, tilt angle, and installation spacing of the conventional photovoltaic panels on the roof. Two retrofitting schemes were proposed. Through simulation and comparison, the second scheme was found to reduce the annual electricity consumption by 1,233,354 kWh, achieving a 35.4% decrease compared to the original building. Using the Changsha library as a template for public buildings, this study provided a retrofitting approach with Building-Integrated Photovoltaic technology via DesignBuilder, which could be extended to other geographic locations. The results demonstrated the significant energy-saving effects of the proposed retrofitting scheme.
- 21 August 2024
- Published by Springer Nature
- p. 220-230
Trapped Annular Pressure Caused by Thermal Expansion Between Double Packers in Ultra-Deep Wells
- 21 August 2024
- Published by Springer Nature
- p. 220-230
Trapped Annular Pressure Caused by Thermal Expansion Between Double Packers in Ultra-Deep Wells
- 29 March 2024
- Published by Elsevier in Geoenergy Science and Engineering
- Vol. 237
Mechanical integrity of tubular elements based on strength and fracture criteria during transient CO2 injection
- 29 March 2024
- Published by Elsevier in Geoenergy Science and Engineering
- Vol. 237
Mechanical integrity of tubular elements based on strength and fracture criteria during transient CO2 injection
- 16 March 2023
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 145 (9)
A Numerical Analysis of Radio Frequency Heating of Coal With Different Ranks
Radio frequency (RF) heating is a novel thermal stimulation method in developing coalbed methane (CBM). Various research has been conducted on the effect of electromagnetic (EM) heating on the physical properties of coal. However, few studies considered the working conditions of underground coal seam heating. This paper calculates the coal seam temperature distribution based on the coupling between electromagnetic wave propagation and heat transfer in a vertical well to study the influence of coal seam metamorphism and thermoelectric characteristics on temperature distribution. The reservoir thermophysical parameters related to temperature are considered in the heat transfer and wave equations, respectively. Numerical simulations reveal the influence of coal ranks and thermo-electrical properties on heating efficacy. Results indicate that the temperature in the vicinity of the RF heater is relatively high, and the whole heated zone forms an elliptical shape. Low-metamorphism coal, such as lignite, is more functional for RF heating and has a broad heating range, leading to a uniform diffusion coefficient enhancement and good thermal homogeneity. Higher thermal conductivity, lower specific heat capacity, and water saturation can expand the heating area and reduce the temperature near the borehole, benefiting the maintenance of wellbore integrity. The coal seam relative permittivity has little effect on the reservoir temperature when its value is between 2.4 and 6.4.
- 16 March 2023
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 145 (9)
A Numerical Analysis of Radio Frequency Heating of Coal With Different Ranks
Radio frequency (RF) heating is a novel thermal stimulation method in developing coalbed methane (CBM). Various research has been conducted on the effect of electromagnetic (EM) heating on the physical properties of coal. However, few studies considered the working conditions of underground coal seam heating. This paper calculates the coal seam temperature distribution based on the coupling between electromagnetic wave propagation and heat transfer in a vertical well to study the influence of coal seam metamorphism and thermoelectric characteristics on temperature distribution. The reservoir thermophysical parameters related to temperature are considered in the heat transfer and wave equations, respectively. Numerical simulations reveal the influence of coal ranks and thermo-electrical properties on heating efficacy. Results indicate that the temperature in the vicinity of the RF heater is relatively high, and the whole heated zone forms an elliptical shape. Low-metamorphism coal, such as lignite, is more functional for RF heating and has a broad heating range, leading to a uniform diffusion coefficient enhancement and good thermal homogeneity. Higher thermal conductivity, lower specific heat capacity, and water saturation can expand the heating area and reduce the temperature near the borehole, benefiting the maintenance of wellbore integrity. The coal seam relative permittivity has little effect on the reservoir temperature when its value is between 2.4 and 6.4.
- 10 October 2022
- Published by Elsevier in Applied Thermal Engineering
- Vol. 219
An analytical model for reservoir temperature during electromagnetic heating based on power transmission
- 10 October 2022
- Published by Elsevier in Applied Thermal Engineering
- Vol. 219
An analytical model for reservoir temperature during electromagnetic heating based on power transmission